POINTAX 6000L2 Point Recorder

Similar documents
LINAX 4000L Continuous-line recorder

POINTAX 6000M Point recorder

LINAX 4000H Continuous line recorder

DIGEM f 96 x 48 EK. Applications. Description

TZIF 4. Current-to-Pulse Converter 10/ EN

Paperless Recorder PR20

U1601 ENERGY CONTROL SYSTEM

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Overcurrent Protection / 7SJ45

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Light-strip indicator

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

KINAX SR 719 Programmable Transmitter for Position Feedback

High precision measurement system for current and voltage IHC-A/B-RM01/03

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

JUMO Wtrans Receiver with Wireless Data Transmission

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

This data sheet is only valid in association with the IL SYS INST UM E user manual.

XUA1 - AC Voltage and phase balance relay

METRATESTER 5+ Tester for DIN VDE /6.15

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

VersaPoint I/O Module

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

MINI-PS AC/2X15DC/1

SINEAX B 811 Power Pack with additional Functions

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

SWT 3000 Teleprotection technical data siemens.com

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

v v PMA With numerous functions and robust construction, the KS 3930 A/B line recorders are ideal for universal industrial applications.

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Digital indicator for panel mounting With multi-function input Model DI25

Transformers, Power Supply Units and Socket Outlets

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

IB IL 24/230 DOR 4/W-PC IB IL 24/230 DOR 4/W-PC-PAC

QUINT-PS-24DC/24DC/10

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

For Immediate Delivery call KMParts.com at (866)

Electronic timer CT-TGD.22

MINI-PS AC/24DC/1.3

QUINT-PS/ 3AC/24DC/10

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

QUINT-PS AC/24DC/40

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

XF2 Frequency Relay. Manual XF2 (Revision A)

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Power supply CP-D 24/1.3

METRAClip87 and 88 Clamp Multimeters

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

IRI1-ER - Stabilized Earth Fault Current Relay. Manual IRI1-ER (Revision A)

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

Electronic timer CT-SDD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

IB ST (ZF) 24 PT 100 4/4

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

XIOC technology and networking modules

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Technical data. General specifications. Measurement range min max. 360

8V General information. 2 Order data 8V

Operating Instructions CAMILLE BAUER METRAWATT METRAOHM /9.97. Low impedance resistance meas. instrument

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Adjustable Digital Process Instrument MDK480

SVP CONTROL AND VISUALIZATION OF VOLTAGE, PHASE AND FREQUENCY IN THREE-PHASE LINES WITH NEUTRAL

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

PHOENIX CONTACT - 03/2007

Type CP-S, CP-C & CP-A Switch mode

AMIK 200 / 201 Technical Data Sheet

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Protection components

ISOMETER IRDH575. Approvals

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Rudder or propeller angular position transmitter KINAX WT720

Temperature transmitter itemp PCP DIN rail TMT 121

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Installation / Monitoring Technique

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

em4 em4 alert em4 alert 2G

62 Series - Power relays 16 A. Features / /

Transcription:

GOSSEN METRAWATT CAMILLE BAUER Special Features 6 measuring channels Last printed point visible from front Electrically isolated, earth-free measuring channels Process signals ranging from 0/4... 20 ma, 0... 1 V Front panel dimensions: 144 mm x 144 mm, installation depth: 250 mm Combination plotter for paper rolls (2 m) or continuous fan-fold paper (16 m) RS 485 interface Description The is a microprocessor controlled point recorder. The recorder measures process signals ranging from 0/4... 20 ma and 0... 1 V. Additional current and voltage signals can be measured by means of plug-on shunts or voltage dividers. Configuration of the recorder for specific measurement tasks is performed by means of software with the integrated keypad, or with a PC in combination with the parameters configuring program PARATOOL P6000L2 via the RS 485 interface. Limit contact outputs, remote advance selection and a stand-by function can be selected as options. GOSSEN-METRAWATT 1

Applicable Regulations and Standards A) International Standards IEC 68-2-6 IEC 68-2-27 IEC 225-4 IEC 529 IEC 721-- IEC 742 IEC 880 IEC 1000-4 IEC 1010-1 IEC 114-1 EN 50081-1 EN 50081-2 EN 50082-1 EN 50082-2 EN 55011 EN 6087 EN 12400 B) German Standards DIN 1624 DIN 24420 DIN 4802 DIN 484 Technical Data Mechanical stress, vibration Mechanical stress, shock 1 MHz pulse to mains cable IP protection DIN VDE 0100 Part 410 DIN VDE 0106 Part 101 Climatic stress Safety isolating transformers Software development Electromagnetic immunity (measuring process) Safety for measuring and control equipment Accuracy class rating Electromagnetic interference, residential Electromagnetic interference, industrial Electromagnetic immunity, residential Electromagnetic immunity, industrial Radio interference, industrial, scientific and medical devices Process recorders Fixed capacitors (Y capacitors) Recorder chart paper Analog Inputs, Nominal Ranges Replacement parts lists for attachments Scales Device mounting Protection against dangerous shock currents Basic requirements for reliable isolation Direct Current 0...20 ma; Ri = 50 Ω 4...20 ma; Ri = 50 Ω with plug-on shunt: 0... 0.5 ma to 0... 500 ma (voltage drop: 1 V) Direct Voltage 0... 1 V with plug-on voltage divider: > 0... 1 V to 0... 50 V Accuracy Measurement error per IEC 114-1 Additional error for shifted start of scale and/or end of scale Influence Error Temperature Reference Temperature Options (code G01) 25 C ± 1K Class 0.5 relative to nominal range nominal range ± 0.1% ----------------------------- 0.1 overall range ± nominal range 0.2 0.05 ----------------------------- 0.05 + overall range %/10 K Atmospheric Humidity observe influence on recorder chart paper per DIN 1624. Supply Voltage 0.1% at 24 V DC/AC ± 20% 0.1% at 24 V AC +10% / 15% 0.1% at 115 V AC +10% / 15% 0.1% at 20 V AC +10% / 15% Interference Voltage 0.5% of measuring span External Magnetic Field, 1 mt 0.5% of measuring span Mechanical Stress during and after exposure to ± 0.5% of per DIN IEC 68-2-6/27 measuring span Transport shock: 0 G/18 ms vibration: 2 G/5... 150 Hz In Operation vibration: 0.5 G/± 0.04 mm/ 5...150 Hz/ 2cycles Binary Inputs Quantity 2 (DI 1, DI 2) Auxiliary Voltage DC 20... 24...0 V Input Current 6 ma H Signal 20... 0 V L Signal 0... 1. V Remote Advance Selection Advance 1 or 2 can be chosen by means of a freely selectable binary input, or advance can be deactivated. Stand-By Function The stand-by function is activated with a freely selectable binary input. Internal deactivation via limit value monitoring is possible. Limit Value Monitoring 2 limit values per channel for monitoring of absolute values. 2 internal relays can be assigned to the limit values. Connected to common potential. Output: normally open contact Contact rating: 0 V / 100 ma 14 additional relays available via external I/O converter. Analog Inputs, Measuring Ranges Measuring Range Lower Limit adjustable from 0... 80% of the respective nominal range Overall Measuring Range adjustable from 20... 100% of the respective nominal range Dead Zone 0.25% of overall measuring range Meas. Value Attenuation with low-pass: 1 st order Time Constant 0... 60 s per channel, programmable Meas. Point Start-Time 2.5... 20 s, selectable 2 GOSSEN-METRAWATT

Recorder Component / Measurement Value Display Scale 1 to 6 graduations Character size per number of graduations: Graduations 1 2 4 5 6 Char. Size (mm) 6 5 2 2 2 2 Channel Display Via measuring point number on the color printing head Scale to Channel Assignments With colored adhesive labels on the scale Control Panel (behind the plotting surface) Power Supply UC-Adapter 24 V AC/DC ± 20% Power consumption with all auxiliary components approx. 15 W / 21 VA AC-Adapter 24/110/20 V AC +10%, 15% Frequency range: 47.5... 6 Hz Power consumption with all auxiliary components approx. 15 W / 21 VA RS 485 Interface For setting parameters Display (only for setting parameters) 5 digit 7-segment display Character size: 4 7 mm Operation With keys Recording Colors violet, red, black, green, blue, brown Color sequence per DIN 488 Channel 1 violet Channel 2 red Channel black Channel 4 green Channel 5 blue Channel 6 brown or can be assigned to channels as desired. Last printed point visible from front Ink reservoir sufficient for 5 10 5 points per color Trends Recording Measurement values are recorded as dotted lines with equidistant spacing between points (for measuring point start-times < 2.5 s). Measuring Point Start-Time 2.5, 5, 10 and 20 s Paper Advance Advance can be configured in mm/hr. as follows: Papertapes Visible Chart Length Printing Width Papertape Feed (for rolls) 0/2.5/5/10/20/0/40/60/120/240/00/ 600 remote selection and deactivation (optional limit value monitoring and binary inputs required) 2 m papertape rolls or 16 m fan-fold paper 60 mm 100 mm (papertape width of 120 mm, DIN 1620) papertape end fed automatically to reel (charts can be cut off daily or entire 2 m can be rolled up) GOSSEN-METRAWATT

Resistance to Climatic Conditions Ambient Temperature 0... 25... 50 C Transport and Storage Temperature 40... +70 C Relative Humidity (with device in operation) 75% (average annual), max. 85%, avoid condensation Climatic Category K per IEC 721-- Electrical Safety Testing per DIN EN 61010-1 or IEC 1010-1 Protection Class I Overvoltage Category III at mains input II at inputs and outputs Fouling Factor 2 in device and at terminal connectors Test Voltage.75 kv, measuring channels to power supply 2.20 kv, protective conductor to power supply Functional extra-low voltage with reliable isolation (PELV) between mains input measuring channels, control cables, interface cables per VDE 0100 Part 410 and VDE 0106 Part 101 Electromagnetic Compatibility Objectives set forth in EMC guideline 89/6/EWG regarding interference suppression in accordance with EN 55011 and regarding interference immunity in accordance with EN 50082-2 have been fulfilled. Factory Default Settings Scale with graduation of 0... 100 is supplied if no scale graduation is specified when the recorder is ordered. Default Parameters If no specific parameter settings are requested when the recorder is ordered, the is supplied with the following default parameters: All measuring channels with a measuring range of 0... 20 ma Advance 1: 20 mm/hr. Advance 2: 120 mm/hr. Measurement value attenuation and zoom function are deactivated. No password required. This parameter setting can be activated at any time in the service mode. Standard Equipment 1 operating instructions 2 device mounts 1 roll of papertape or package of fan-fold paper, installed 1 color printing head Optional equipment: Locating bracket for grid system installation, reference reading rule(s) Interference Suppression per EN 55011 Interference voltages at mains cables: 0.15... 0 MHz Class B Interference field strength: 0 MHz... 1 GHz Class B Interference Immunity: Testing per EN 60801 Test Type Test Level Influence Severity ESD (1/0 ns) 6 kv HF Field emitted 80 MHz... 1 GHz mains-borne 0.15... 80 MHz Burst (5/50 ns) to mains cable measurement cable Surge (1.2/50 µs) to mains cable common differential 1 MHz pulse to mains cable common differential 10 V/m 10 V 2kV 2kV 2kV 1kV 2kV 1kV The NAMUR industry standard for EMC has been fulfilled (shielded interface cables). Allowable Interference Voltages Allowable Interference Voltages Series-mode interference voltage, 0. measuring span, maximum V peak to peak Normal-mode rejection Common-mode interference voltage Common-mode rejection 75 db 60 V DC / 250 V AC 8 db for DC 96 DB for AC 2 4 GOSSEN-METRAWATT

Terminal Connections, Housing and Mounting Electrical Connections IP 20 protection Plug and screw terminals for measurement and control inputs Max. wire cross section: 2 1mm 2 Screw terminals for mains connection Max. wire cross section 1 4mm 2 or 2 1.5 mm 2 RS 485 interface via 9-pole SUB-D plug Housing Molded housing for mounting to control panel or grid system installation (see drawing for dimensions) Housing Protection per IEC 529 Front panel (including door) IP 54 Rear panel IP 20 Housing Color Pebble gray per RAL 702 Housing Door Molded Option: metal door frame with mineral glass Housing Mounts 2 mounting elements (for either control panel or grid system mounting) for a maximum grid width of 40 mm. Locating brackets required for grid system installation (order no. A416A) Position of Normal Use side to side: 0... 0... +0, backward slope: 20, forward slope: 20 Mounting Clearances Horizontal or vertical: 0 mm, housing door must open out to 100 Weight: approx..5 kg Network Diagram LINAX 4000H LINAX 4000M POINTAX 6000M POINTAX 6000M RS 485 / RS 22 Adapter Set PARATOOL P6000M Parameters Configuration Software or Superordinate Systems GOSSEN-METRAWATT 5

Dimensional Drawing (dimensions in mm) Control Panel Opening Wiring Diagram CH1 01 012 011 CH2 02 022 021 CH 0 02 01 CH4 04 042 041 CH5 05 052 051 CH6 06 062 061 U I 901 912 + 922 + DI1 DI2 801 812 822 D01 D02 RS 485 Interface Pin 1: shield Pin : RXD (+) Pin 4: I/O converter (+) Pin 5: GND (reference potential) Pin 6: +5 V Pin 8: RXD (-) Pin 9: I/O converter ( ) For Bus Operation: +5 V is required at pin 6, when the is installed as a bus user. 5 5 5 The shield is connected to a knife contact at the recorder housing. 6 6 6 Binary Inputs for advance selection and activation of the stand-by function Measuring Inputs Limit Contacts DI1 DI2 6 GOSSEN-METRAWATT

Order Information (continued) Description ID Number point recorder with identical DC measuring ranges for all 6 channels Front panel dimensions: 144 x 144 mm A490 Measuring ranges for all channels DC 0... 20 ma, 0... 10 V or external adjustment D001 Use accessory resistors for external adjustment. 4... 20 ma D002 Parameter Settings standard DP000 DP900 Scale Channel 1 same as measuring range EA001 without graduation EA002 0... 100 EA00 EA900 Channel 2 same as measuring range EB001 without graduation EB002 0... 100 EB00 EB900 Channel same as measuring range EC001 without graduation EC002 0... 100 EC00 EC900 Channel 4 same as measuring range ED001 without graduation ED002 0... 100 ED00 ED900 Channel 5 same as measuring range EE001 without graduation EE002 0... 100 EE00 EE900 Channel 6 same as measuring range EF001 without graduation EF002 0... 100 EF00 EF900 Continued on next page. GOSSEN-METRAWATT 7

Order Information (continued) Description ID Number Reference Reading Rule Channel 1 without reference reading rule FA000 same as scale FA001 Channel 2 without reference reading rule FB000 same as scale FB001 Channel without reference reading rule FC000 same as scale FC001 Channel 4 without reference reading rule FD000 same as scale FD001 Channel 5 without reference reading rule FE000 same as scale FE001 Channel 6 without reference reading rule FF000 same as scale FF001 Limit Value Monitoring and Binary Inputs without limit value monitoring and without binary inputs G000 with limit value monitoring and binary inputs G001 Auxiliary Voltage 24 V DC/AC H004 24 V AC H001 115 V AC H002 20 V AC H00 Recording with papertape rolls, 2 m K001 with continuous fan-fold paper, 16 m K002 Housing Door plastic M001 metal M002 Measuring Point Identification Label no entries and with GMC logo N000 no entries and without logo N001 with customer specified entries, max. 1 characters per line / measuring point N900 Test Report none P000 with factory certificate per DIN 50049 P001 Operating Instructions German W000 none W001 English W002 French W00 8 GOSSEN-METRAWATT

Order Example point recorder with identical DC measuring ranges for all 6 channels A490 Front panel dimensions: 144 x 144 mm Measuring Ranges DC 0... 20 ma, 0... 10 V or external adjustment D001 Parameter Settings standard DP000 Scale, Channel 1 0... 100 EA00 Scale, Channel 2 0... 50 l/s EB900 Scale, Channel 0... 100% EC900 Scale, Channel 4 0... 50 ED900 Scale, Channel 5 0... 100 EE00 Scale, Channel 6 same as measuring range EF001 Reference Reading Rule, Channel 1 same as scale FA001 Reference Reading Rule, Channel 2 same as scale FB001 Reference Reading Rule, Channels... 6 without reference reading rule FC000... FF000 Limit Value Monitoring and Binary Inputs with limit value monitoring and binary inputs G001 Auxiliary Voltage 20 V AC H00 Recording with papertape rolls, 2 m K001 Housing Door metal M002 Measuring Point Identification Labels no entries and with GMC logo N000 Test Report none P000 Operating Instructions German W000 GOSSEN-METRAWATT 9

Accessories (continued) ID numbers which end with a letter are complete and do not require any additional information. The following characteristics should be entered for ID numbers which end with a number. Description ID Number PARATOOL P6000L2 parameter configuration software for A402E RS485/RS22 adapter set, including AC-adapter and m connector cable, with plugs at both ends and 9/25 pole adapter plug Scale without graduation, markings for minimum and maximum scale values Scale, max. 6 graduations character size with 1 graduation: 6 mm character size with 2 graduations: 5 mm character size with to 6 graduations: 2 mm Characters size determined according to specified number of graduations If no graduations are specified, scale is supplied without graduation Graduation 1: without graduation Graduation 1: 0... 100 Graduation 1: Graduation 2: without graduation Graduation 2: 0... 100 Graduation 2: Graduation : without graduation Graduation : 0... 100 Graduation : Graduation 4: without graduation Graduation 4: 0... 100 Graduation 4: Graduation 5: without graduation Graduation 5: 0... 100 Graduation 5: Graduation 6: without graduation Graduation 6: 0... 100 Graduation 6: Reference reading rule, 1 graduation Graduation Measuring point identification label with GMC logo without GMC logo Channel 1 (violet) no entries Channel 1 (violet) with entries (max. 1 characters, mm characters) Channel 2 (red) no entries Channel 2 (red) with entries (max. 1 characters, mm characters) Channel (black) no entries Channel (black) with entries (max. 1 characters, mm characters) Channel 4 (green)no entries Channel 4 (green) with entries (max. 1 characters, mm characters) Channel 5 (blue) no entries Channel 5 (blue) with entries (max. 1 characters, mm characters) Channel 6 (brown) no entries Channel 6 (brown) with entries (max. 1 characters, mm characters) Plug-on shunt resistors for external measuring range expansion for the following ranges: 0... 0.1 ma to 0... 0.5 ma 0... 0.5 ma to 0... 2.5 ma 0... 1 ma to 0... 5 ma 0... 20 ma to 0... 100 ma 0... 100 ma to 0... 500 ma Plug-on voltage dividers for measuring range expansion for the following ranges: > 0... 1 V to 0... 5 V 0... 5 V to 0... 25 V 0... 10 V to 0... 50 V Continued on next page. 10 GOSSEN-METRAWATT A40A A44A A450 EA002 EA00 EA900 EB002 EB00 EB900 EC002 EC00 EC900 ED002 ED00 ED900 EE002 EE00 EE900 EF002 EF00 EF900 A460 AA900 A470 AA000 AA001 BA001 BA900 BB001 BB900 BC001 BC900 BD001 BD900 BE001 BE900 BF001 BF900 A480 BR001 BR002 BR00 BR004 BR005 BR010 BR011 BR012

Accessories (continued) ID numbers which end with a letter are complete and do not require any additional information. The following characteristics should be entered for ID numbers which end with a number. Description Screw terminals with connectors Screw terminals with 4 connectors Locating bracket, 4 ea. (for grid system installation) Bus matching resistors Package of 2 ea. 90 Ω and 1 ea. 150 Ω ID Number A404A A419A A416A A409A Consumable Materials (continued) ID numbers which end with a letter are complete and do not require any additional information. The following characteristics should be entered for ID numbers which end with a number. Description Recording paper, paper width: 120 mm, recording width: 100 mm Papertape roll, 2 m, graduation: 0... 100, minimum order: 25 rolls time graduation / advance none 10 mm/hr. 20 mm/hr. 60 mm/hr. 120 mm/hr. ID Number A401A A401B A401C A401D A401E Papertape roll, 2 m, graduation: 0... 100, minimum order: 25 rolls A4070 time graduation / advance CA900 Papertape roll, 2 m, with calibration graduation, minimum order: 25 roll calibration graduation entries time graduation / advance A4071 AA900 BA900 CA900 Continuous fan-fold paper, 16 m, graduation: 0... 100, minimum order: 25 packages time graduation / advance none 10 mm/hr. 20 mm/hr. 60 mm/hr. 120 mm/hr. A401L A401M A401N A401P A401Q Continuous fan-fold paper, 16 m, graduation: 0... 100, minimum order: 25 packages A4075 time graduation / advance CA900 Continuous fan-fold paper, 16 m, with calibration graduation, minimum order: 25 packages calibration graduation entries time graduation / advance Printing head A4074 AA900 BA900 CA900 A405A GOSSEN-METRAWATT 11

Printed in Germany Subject to change without notice 1/.98 order no. -48-865-0 GOSSEN-METRAWATT GMBH 9027 Nuremberg, Germany Company address: Thomas-Mann-Strasse 16-20 90471 Nuremberg, Germany Telephone +49 911 8602 0 Telefax +49 911 8602 669 GOSSEN METRAWATT CAMILLE BAUER