IntesisBox PA-AC-ENO-1i (868 MHz) PA-AC-ENO-1iC (315 MHz)

Similar documents
IntesisBox PA-AC-ENO-1i (868 MHz) PA-AC-ENO-1iC (315 MHz)

IntesisBox ME-AC-ENO-1 / 1C v.1.0.9

IntesisBox ME-AC-ENO-1C

IntesisBox DK-AC-ENO-1C

IntesisBox ME-AC-BAC-1

IntesisBox USB-ENO-ASCII-C

Allure ECW-Sensor Series

Wireless Zone Sensor

EnOcean Wireless Systems RANGE PLANNING GUIDE

EnOcean Wireless Systems RANGE PLANNING GUIDE

Range Planning Guide for Systmes usind EnOcean Radio Standard

Wireless Relay Station, BS370 - NTM/KRCNB /1PD104R

Technical data lumina MS4/RC

EPM 300(C) Installation Test Tool User Manual Template for OEM Manufacturers/First Marketer

PDAM500 Series 500W Power Supply

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

R&S RSC Step Attenuator Specifications

Emergency PHM Series. Emergency PowerHUBB Node - Master/Control/Tunable White. Dimensional Data. Ordering Information (Example: PHM4PC EM)

em4 em4 alert em4 alert 2G

STC65 RS485 Modbus. EnOcean Receiver/Transmitter with RS485 Modbus Interface. Data Sheet. Application. Security Advice Caution.

PowPak CCO Module. PowPak CCO Module Energi TriPak Series Wireless Lighting Control

WIRELESS MODBUS GATEWAY WGW410

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

6.2 dbi , MHz IP C to +70 C

Instruction manual ADN-W AM. Antenna Module

ERM-DA. Installation Guide

Link Mobile Gateway User Guide A ProVIEW System Component

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

JUMO Wtrans Receiver with Wireless Data Transmission

Packaging. nom. Output Voltage

HARDWARE GUIDE. FlexIO Controller M2000 Series. Specifications and Operational Guide

Accutech BR10. Wireless base radio

Notes: Note3: without suffix, standard isolation voltage (1kVDC/1 second) with suffix /H, high isolation voltage (3kVDC/1 second)

Wireless multizone receiver RDE-MZ6

TOP VIEW. 6.75" (171.5mm) Network ID Selector. Input Voltage Selection Jumper 7.285" (185mm) Battery Positive Terminal SIDE VIEW. 6.12" (155.

Vive PowPak CCO Module

HyperLink Wireless Low PIM DAS Ceiling Antenna Model: HG75805CUPR-NF

Cooling Fans G-17. Cooling Fans G-17. AC Input/Low-Power Consumption EMU Series. AC Input/Compact Size MU Series


Features. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter

Operating Manual LITEMASTER PRO L-478DR-PX L-478DR-A-PX L-478DR-U-PX. Light Meter

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Accutech BR20. DIN rail mounted base radio

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Doodle Labs WiFi Frequency Shifter xm-915

WLS-5500 Receiver (KSF & W26)

Winding Ohmmeter & Tap Changer Test Set RMO10TW

Features. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter

Vector Network Analyzers ZVB

Voltage Adjustment. Load Regulation

ARUBA AS-100 WIRELESS SENSOR

Operating Manual LITEMASTER PRO L-478DR L-478DR-A L-478DR-U. Light Meter

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

Battery-Free Wireless Pushbutton Useful Tips for Reliable Range Planning

NI PXI-2521 Specifications 40-Channel DPST Relay Module

2-channel models. 4-channel models

5 - IN - 1 MIMO/GPS/WIFI ANTENNA

RE17LLBM asymmetrical flashing relay s V AC - solid state output

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Output Full Load

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

HyperLink Wireless Low PIM DAS 2x2 MIMO Ceiling Antenna Model: HG72706DPCUPR-NF

Agilent U2000 Series USB Power Sensors. Data Sheet

A new approach to static electricity countermeasures

HyperLink Wireless Low PIM MHz Omni-Directional Ceiling Antenna Model: HG35805CUPR-NF

Industrial Serie +600S

Accutech GP10. Wireless gauge pressure field unit

NI SCXI Specifications

NI PXI-2555 Specifications

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

NI PXI-2520 Specifications 80-Channel SPST Relay Module

N432A Thermistor Power Meter DATA SHEET

Sorensen HPD Series 300 W 5 20 A. 300 Watt DC Power Supply with Near-Linear Performance V. with automatic crossover and mode indication

LRF2DCRBWH Wireless RF Daylight Sensor White

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

Accutech AP10. Wireless absolute pressure field unit

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Efficiency higher than 85% Power Factor >95% Case TC* Protec on

Accutech AM20. Wireless acoustic monitor field unit

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

Wireless Temperature Sensor with Probe

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

ēko Pro Series System

Wireless Temperature Sensor

1000BASE-T Copper SFP Transceiver

User Manual EnOcean V 0.1

Signal conditioner - MACX MCR-UI-UI-NC

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

NI PXI/PXIe-2529 Specifications

Three-Phase Winding Ohmmeter TWA25K

NI PXI-2557 Specifications

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Product Specification sheet

Accutech RT10. Wireless RTD temperature field unit

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Transcription:

IntesisBox PA-AC-ENO-1i (868 MHz) PA-AC-ENO-1iC (315 MHz) Interface EnOcean for PANASONIC Air Conditioners (Etherea Line) Air Conditioner Indoor unit (split) PA-AC-ENO-1i PA-AC-ENO-1iC 4 x potential-free binary inputs, USB IntesisBox PA-AC-ENO-1i allows monitoring and control, fully bi-directionally, all the functioning parameters of PANASONIC Air Conditioners from EnOcean installations. Small dimensions. Quick installation and possibility of hidden installation. External power not required. Direct connection to the AC indoor unit (split unit). Fully EnOcean interoperable. Control and monitoring, from sensors or gateways, of the internal variables of the indoor unit and error codes and indication. Use the air conditioner ambient temperature or the one measured by an EnOcean temperature sensor or Thermostat. AC unit can be controlled simultaneously by the remote control of the AC unit and by EnOcean devices. Advanced control functions: use it as a room controller. 4 binary inputs. They work as standard EnOcean binary inputs as well as being used to control the AC directly. 1 / 6

1. EnOcean Interface PA-AC-ENO-1i: working at 868 MHz (Europe) PA-AC-ENO-1iC: Working at 315 MHz (USA and Asia) Coverage Conditions < 300 m Open areas < 30 m Under ideal conditions: Broad room, no obstacles and good antenna position. < 20 m The room is filled with furniture and people And penetration through up to 5 dry walls or up to 2 brick walls or up to 2 aero concrete walls. < 10 m Identical to the previous case but the receiver is placed to a room corner or range along a narrow floor. < 1 m Metal-reinforced ceilings at upright penetration angle (in strong dependence of reinforcement density and antenna positions). Table 1.1 Device coverage distance 1.1 Reception Channels Reception channels where up to 5 devices can be linked. The links can be achieved using the manual teach-in learning procedures or using Intesis Configuration Software. Figure 1.1 Reception channels with their associated signals and devices 2 / 6

1.2 Transmission Channels Transmission channels to be used to teach the Air conditioner interface into other devices. As in the reception channels the procedure can be done manually as well as using Intesis Configuration Software. Figure 1.2 Transmission channels with their EEPs and unique ID s 1.3 Configuration Configure the behavior of the AC interface, its advanced functionalities as well as the binary inputs using Intesis Configuration Software. Figure 1.3 Device parameter configuration 3 / 6

2. Connections Connection with the Air conditioner indoor unit Connection of the interface to the AC indoor unit is by means of the cable supplied with the interface which must be connected to the interface in one side (K1 connector), and to the internal electronic board of the Air Conditioner in the other side (connector CN-CNT in Etherea line units). AC indoor unit (split) Internal control board CN-CNT Connection cable supplied with the interface. PA-AC-ENO-1i Connection to the binary inputs: The binary inputs are connected to the interface (K2 connector) and to the contacts on the other side. 4 / 6

3. Technical Specifications Envelope Dimensions Weight Color Power supply Mounting LED indicators (internal) ABS (UL 94 HB). 2,5 mm thickness 70 x 100 x 28 mm 80g White 12V, 55mA typical Doesn t require external power supply (supplied by the AC Unit) Wall. 1 x AC unit state 1 x EnOcean state 4 x Potential-free binary inputs. Signal cable length: 5m unshielded, may be extended up to 20m with twisted. Binary inputs Compliant with the following standards: IEC61000-4-2 : level 4-15kV (air discharge) - 8kV (contact discharge) MIL STD 883E-Method 3015-7 : class3b Configuration Operating Temperature Operating humidity Stock humidity RoHS conformity Manual procedures: Teach-in and Learning Remote wireless Configuration from PC 1 From -25ºC to 85ºC <93% HR, no condensation <93% HR, no condensation Compliant with RoHS directive (2002/95/CE). PA-AC-ENO-1i: CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) o EN 61000-6-2 Certifications o EN 61000-6-3 o EN 60950-1 PA-AC-ENO-1iC: o EN 50491-3 FCC (ID: SZV-STM300C) IC (ID: 5713A-STM300C) 1 Details can be found in the User Manual 5 / 6

4. AC Unit Types compatibility. A list of Panasonic indoor unit model references compatible with PA-AC-ENO-1i and their available features can be found in: http://intesis.com/pdf/intesisbox_pa-ac-xxx-1_ac_compatibility.pdf 5. Dimensions (mm) 6 / 6