S5 (PMR-446) Model Programming software for S5 (PMR-446) Model

Similar documents
AT-D868UV CodePlug Programming Guide

DJ-MD5 PC Software Guidance

Welcome to the KNG-P150S

AT-D868UV CodePlug Programming Guide

AT-5888UV Programming Software for the AnyTone AT-5888UV

YCE13. Dealer PC Programming Software Reference Manual. Attention!

RPS-9000 Programming Software for the TYT TH-9000

TABLE OF CONTENTS. Keypad Programming Manual 1

AT-D868UV CodePlug Programming Guide

FM HANDHELD TRANCEIVER. Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA Version 1.00

ATP-5189 Programming Software for the Anytone AT-5189

AT-D868UV CodePlug Programming Guide

ATP-588 Programming Software for the Anytone AT-588

TECHNICAL INFORMATION BULLETIN

MIDLAND PROGRAMING G14

BTech DMR-6X2 CodePlug Programming Guide

AT-D868UV CodePlug Programming Guide

AT-D868UV CodePlug Programming Guide

AT-D868UV CodePlug Programming Guide

Content. Maintenance. Features ENGLISH. 1 transceiver 1 antenna 1 battery pack 1 belt clip 1 fast desktop charger User manual

_ Programming Manual RE729 Including Classic and New VoX Interfaces Version 3.0 May 2011

Field Software Notice

AT-D868UV CodePlug Programming Guide

Reference for UV-5R Menus by Jim Unroe - KC9HI 2-April-2014

instruction manual for Open LRS New Generation

WCS-D5100 Programming Software for the Icom ID-5100 Data

AT-D868UV CodePlug Programming Guide

Logical Trunked. Radio (LTR) Theory of Operation

CHIPSWITCH DOC S RADIO REPAIR OWNERS MANUAL. HR2510 / HR2600 / LINCOLN 10 Meter Amateur Transceiver.

HD1 CPS Brief Introduction

Programming Parameter Guide

YAESU MUSEN CO., LTD.

ADMS-847 Programming Software for the Yaesu FT-847

Programming Parameters - Feature Comparison : Rev 1

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

Downloading a ROBOTC Sample Program

DuraFon UHF Quick Ref. / FAQ Sheet

RADITEK INC. code -g11

Programming Instructions for: Kenwood TK-780, 880, 980, 981 (Version 2) W/ KCT-19 Option Connector For use with: Pyramid Communications Model

FM HANDHELD TRANCEIVER. Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA Version 1.00

DC Instruction Manual. Professional FM Transceiver

DC-1122 Compact 5W UHF CB Radio

LC-10 Chipless TagReader v 2.0 August 2006

CS2010 AND CS2011 ALIGNMENT REFERENCE MANUAL FM HANDHELD TRANCEIVER. Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA 93003

RL /430MHZ DUAL BAND FM TRANSCEIVER OPERATION INSTRUCTION

RMV25 / RMV50 RMU25 / RMU45

INDEX...2 INTRODUCTION...3 IMPORTANT NOTES...3 INSTALLING THE SOFTWARE...3 ST-965 PROGRAMMING SOFTWARE...6

Version SmartPTT Enterprise. Web Client User Guide

OPERATING GUIDE VHF DIGITAL TRANSCEIVERS. if1000d. series UHF DIGITAL TRANSCEIVERS. if2000d series. The photo shows the VHF transceiver.

UV-5R Manual. pofung UV-5R

Kenwood TH-G71 Protocol Specification

USER S MANUAL. VHF-UHF Mobile transceiver for radioamateur

M2M i-link POINT-TO-MULTIPOINT INSTALLATION INSTRUCTIONS

Version 8.8 Linked Capacity Plus. Configuration Guide

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

REV DCA DATE DRAWN CHECKED APPROVED PUBLISHED A W /13/2014 Ken Marshall Heath Flor Jay Jensen Linda Andujo

Lava LP-4011-E P1 P2 USER MANUAL

Release 0.3. Rolling Thunder Technical Reference Manual

JEM Radio II Operation Guide. Manual P/N M Victor Place Colorado Springs, Colorado

IC-400pro - RADIOAFICION.COM

NOVA technical note #8 1. Case study: how to use cutoff conditions in a FRA frequency scan?

BeeLine TX User s Guide V1.1c 4/25/2005

WPE 48N USER MANUAL Version1.1

High Point Communications Authorized dealer for USA Fleet Services

DUAL BAND MOBILE RADIO USER S MANUAL

FCC ID: AXI IC: 10239A Alignment

MOTOTRBO R1.8 Training Overview

Code Plug Basics for the MD-380 David Hull, KC6N July 27, 2017

Section 4 RADIO PROGRAMMING

Micro Fox PicCon Manual

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Sodium Thiosulphate and hydrochloric acid

Will only send Status Text until GPS Lock! Format of Status Text: Status Text Altitude Volts Temp X AVRT5 (version)

OPERATING GUIDE OPERATING GUIDE FOR IC-F3160/F4160 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION

Exercise 2-2. Four-Wire Transmitter (Optional) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Ultrasonic level transmitter DISCUSSION

MOTOBRIDGE Dispatch Application Overview

Changing settings in the BlueSolar MPPT Charge Controllers

THANK YOU FOR YOUR PURCHASE OF THE UV THIS DUAL BAND RADIO WILL DELIVER TO YOU SECURE INSTANT RELIABLE COMMUNICATION.

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS NXDN OPERATION

Guardian and DL3282 Modem Interface Technical Service Application Note

Disable Windows Sounds

Model: TP380 User Manual

FTM-3100R/E. Advance Manual VHF FM TRANSCEIVER DIAL VOL

PMR446 Radio Instruction Manual

LH Series Sensor Configurator Software User Manual rev. D 1/11/2012

Introduction Mechanical radio operation... 12

FOD Transmitter User s Guide

ALAN 777 PMR 446 Radio Set User manual

CS3000 ALIGNMENT REFERENCE MANUAL FM HANDHELD TRANCEIVER. Connect Systems Incorporated 1802 Eastman Ave., Suite 116 Ventura CA Version 1.

CONTENTS. Operation File name (TH-D72_) CONTENTS 1 OPERATING THROUGH REPEATERS... REPEATER. 01_REPEATER_E.pdf MEMORY CHANNELS...

Cat. No OWNER S MANUAL. HTX-212 Two-Meter Mobile Transceiver. Please read before using this transceiver.

VX-4100/4200SERIES. VHF/UHF Mobile Radios

THANK YOU FOR YOUR PURCHASE OF THE UV THIS DUAL BAND RADIO WILL DELIVER TO YOU SECURE INSTANT RELIABLE COMMUNICATION.

How to set up Teamspeak 3 on your Windows PC

CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA FLEX SERIES UNIVERSAL CONTROLLER

Introduction to Lab Instruments

OPERATING INSTRUCTIONS. Til Document: 08RE399 Rev. N/C OCT Technisonic Industries Limited.

OPERATING GUIDE OPERATING GUIDE FOR IC-F5060/F6060 SERIES BIIS 1200/MDC 1200 SYSTEM/ LTR /IDAS OPERATION

B & D Enterprises 1P repeater controller pg 1 INTRODUCTION:

Manual Intelligent Motion Controller

Transcription:

S5 (PMR-446) Model Programming software for S5 (PMR-446) Model PC Program S5 (PMR-446) Model Software Guide Version 1.3 issued on December 15 th 2007 Version 1.3 Page 1

CONTENTS 1. Basic Programming...3 1.1 Channel Frequency Setting..........3 1.2 Rx frequency, Rx tone, Tx frequency and Tx tone setting.... 4 1.3 Rx and Tx option setting.......6 1.4 System Option setting...........8 1.5 2-Tone setting........10 2. Tool Bar........12 2.1 Tool Bar mode....... 12 2.2 New.....12 2.3 Open......12 2.4 Save.......12 2.5 Print.........12 2.6 Program.........13 2.7Exit....13 3. Menu......15 3.1 File Menu.......15 3.2 Help Menu..........15 Version 1.3 Page 2

1. Basic Programming 1.1 Channel Frequency Setting Channel frequency cans use only 8 channels. 1 2 3 [1] Rx frequency, Rx tone, Tx frequency and Tx tone Setting. Double click in table (see1.2). [2] Rx and Tx Option setting. Double click in table (see 1.3) [3] S5 Pc programming Detail. It ll show about information of the model name, maximum of channel pc program and firmware version and when you ve clicked in column on table (Rx Freq. LB column) it ll show the detail of data setting. Version 1.3 Page 3

1.2 Rx frequency, Rx tone, Tx frequency and Tx tone Setting When you had double clicked on the line related to the radio channel you need to program it ll show you in this window. 2 1 3 4 1.2.1 Rx / Tx Channel Freq >>?? <<. is the number of the channel frequency setting. 1.2.2 Rx / Tx Freq. is the Frequency setting which have range between 446.00625-446.09375 MHz (in the table). Model S5 (PMR-446) Frequency Range 446.00625 446.09375 MHz Auto channel step is set to 446.00625, 446.01875, 446.03125, 446.04375, 446.05625, 446.06875, 446.08125 and 446.09375.When select in Rx / Tx Frequency list box. And Auto Frequency when none frequency selected is set to the Low frequency of S5 (PMR-446) model s range (446.00625 MHz). 1.2.3 Rx / Tx Tone select. 1.2.3.1 None tone is Rx and Tx not use sub tone frequency modulation. 1.2.3.2 Ctcss tone has use 49 tone in analog modulation, the range is between 67.0-254.1 Hz. No Ctcss No Ctcss No Ctcss No Ctcss No Ctcss 01 67.0 11 94.8 21 131.8 31 173.8 41 206.5 02 69.3 12 97.4 22 136.5 32 177.3 42 210.7 03 71.9 13 100.0 23 141.3 33 179.9 43 218.1 04 74.4 14 103.5 24 146.2 34 183.5 44 225.7 05 77.0 15 107.2 25 151.4 35 186.2 45 229.1 06 79.7 16 110.9 26 156.7 36 189.9 46 233.6 07 82.5 17 114.8 27 159.8 37 192.8 47 241.8 08 85.4 18 118.8 28 162.2 38 196.6 48 250.3 09 88.5 19 123.0 29 167.9 39 199.5 49 254.1 10 91.5 20 127.3 30 171.3 40 203.5 Version 1.3 Page 4

1.2.3.3 DCS and IDCS (Invert DCS) Tone has use 104 tone in digital modulation. No DCS No DCS No DCS No DCS No DCS No DCS 1 023 21 125 41 245 61 356 81 506 101 732 2 025 22 131 42 246 62 364 82 516 102 734 3 026 23 132 43 251 63 365 83 523 103 743 4 031 24 134 44 252 64 371 84 526 104 754 5 032 25 143 45 255 65 411 85 532 6 036 26 145 46 261 66 412 86 546 7 043 27 152 47 263 67 413 87 565 8 047 28 155 48 265 68 423 88 606 9 051 29 156 49 266 69 431 89 612 10 053 30 162 50 271 70 432 90 624 11 054 31 165 51 274 71 445 91 627 12 065 32 172 52 306 72 446 92 631 13 071 33 174 53 311 73 452 93 632 14 072 34 205 54 315 74 454 94 654 15 073 35 212 55 325 75 455 95 662 16 074 36 223 56 331 76 462 96 664 17 114 37 225 57 332 77 464 97 703 18 115 38 226 58 343 78 465 98 712 19 116 39 243 59 346 79 466 99 723 20 122 40 244 60 351 80 503 100 731 1.2.3.4 None Standard Ctcss#1 and None Standard Ctcss#2 tone frequency. None Standard Ctcss tone s range is 55.0 260.0 Hz, it can change tone frequency by System option setting mode in None standard Ctcss#1-#2 case. 1.2.4 Button Active 1.2.4.1 Clear Channel Frequency button. Use to clear the frequency data which was setted or the wrong data setting. 1.2.4.2 Back Channel Frequency button. Use to call the frequency that you setting before or show the frequency in the lower channel that you were setted into the table. 1.2.4.3 Next Channel Frequency button. Use to show the frequency in the upper channel that you were setted into the table. 1.2.4.4 Setting button. This button use for setting data into the table.if there aren t Rx or Tx Frequency in text box, program will auto setting to the lowest frequency of S5 Model s band which you d selected in the first time. 1.2.4.5 Exit button. Exit button is use for exit from channel setting form. Version 1.3 Page 5

1.3 Rx and Tx Option setting 1.3.1 Rx-IND It s Individual Tone setting in Rx mode receive only, Step set is OFF Tone1 Tone2 OFF And then use Tone1 and Tone 2 frequency by 2-Tone Setting. OFF : Rx Individual tone disable Tone1 : Rx use Individual tone1 Tone2 : Rx use Individual tone2 1.3.2 Rx-Grp It s Group tone setting in Rx mode receive only, Step set is ON OFF. ON: Rx Group tone enables OFF: Rx Group tone disable 1.3.3 Rx-SGrp. It s Super Group tone setting in Rx mode receive only, Step set is ON OFF. ON: Rx Super Group tone enables OFF: Rx Super Group tone disable User 10 Individual Tone 1 User 8 Individual Tone 2 User 9 User 2 User 3 User 1 Group tone Super group User 6 User 4 User 5 User 7 User 11 Version 1.3 Page 6

1.3.4 Power It s Only Tx Power Low (L) transmits. L: Tx power Low transmit 1.3.5 Band It s Only Narrow (N) bandwidth N: Narrow band 1.3.6 Scan It s Channel scan option enable / disable, Double click to change ON OFF and OFF ON. ON: Channel scan enable OFF: Channel scan disable 1.3.7 Pri It s Channel Priority enable/disable, Double click to change ON OFF and OFF ON. It s can only one channel setting. If channel priority disable, all priority channel scan look back (1.3.8) will disable. ON: Channel Priority enables OFF: Channel Priority disables 1.3.8 LB It s Priority Channel Scan Look Back enable/disable; Double click to change ON OFF and OFF ON. It s can t set as same as channel priority (1.3.7) setting when channel priority set to enable. If channel priority disable, all of them can t setting, but if channel priority is set to enable, the Priority Channel Scan Look Back can set to enable and disable. ON: Priority Channel Scan enables. OFF: Priority Channel Scan disables Version 1.3 Page 7

1.4 System Option setting 1 2 3 4 5 6 7 8 9 [1] Options setting 1.1 Busy Ch. Lock is busy channel lock. When busy channel lock use enable, can Marked Idle setting. 1.2 Tx delay is use Tx delay time when transmit. 1.3 Priority look back time. When Priority channel use enable (see 1.3.7), can setting. 1.4 Emergency Key is the function to set Enable/Disable Emergency Key. 1.5 Monitor Key is the function to set Enable/Disable Monitor Key. [2] TOT Time 2.1 TOT time use enable, can tx time out time and tot penalty setting. If TOT time use disable, tx time out time, tot penalty and tot penalty time can t setting. 2.2 TOT penalty use enable, can tot penalty time setting. [3] Power save 3.1 Power save use enable power on time, power off time and power delay time, can setting. But can t setting use disable. [4] Scan 4.1 Scan use enable scan Ch no, scan speed and scan delay, can setting. But can t setting use disable. 4.2 Operation mode is use 2 case 4.2.1 Priority channel disable, can use normal scan tx and rx only no tx select. 4.2.2 Priority channel enable, can use priority scan tx and priority only tx select. [5] Password It s radio password key. 5.1 Password use enables. 1st password key 4th can setting. But can t setting disable. And can set 1st 4th in same password key. [6] 2-Tone 6.1. 2-Tone receive OK alert use disable or enable. 6.2. 2-Tone receive remind display use enable. Can 2-Tone interval tone setting. [7] Option key assign It is option key can use one key only select. Version 1.3 Page 8

[8] Emergency call tx channel 8.1 Emergency call tx channel can use 2 case 8.1.1 Emergency call tx channel form current channel tx or 8.1.2 Emergency call tx channel form assigned channel tx. Assigned channel tx can select channel in tx channel frequency. [9] None stand ctcss#1-#2 9.1 None standard ctcss#1 and ctcss#2 ranges is 55.0 260.0 Hz. Use for Rx and Tx modulation for none standard ctcss. 9.2 If over range. Auto ctcss 67.0 Hz setting Version 1.3 Page 9

1.5 2-Tone setting 5 1 2 3 4 [1] 2-Tone Individual tone1 For Rx receive only in individual tone1.it can select tone1 or tone 2 for receive in individual tone1 only. And can Individual tone 1 receive data in Rx mode. 1.1 Tone Frequency range is 280 3000Hz, default 300.0Hz 1.2 Tone Duration range e is 100 10000ms, default 200 ms 1.3 Gap Time range e is 100 10000ms,default 200ms If Tone 2 Enable was selected, can set tone 2 in anywhere. [2] 2-Tone Individual tone2 For Rx receive only in individual tone2.it can select tone1 or tone 2 for receive in individual tone2 only. And can Individual tone 1 receive data in Rx mode 2.1 Tone Frequency range is 280 3000Hz, default 300.0Hz 2.2 Tone Duration range is 100 10000ms, default 200 ms 2.3 Gap Time range is 100 10000ms,default 200ms If Tone 2 Enable was selected, can set tone 2 in anywhere. [3] 2-Tone Group tone For Rx receive only in group tone. it can select tone1 or tone 2 for receive in group tone only. And can Individual tone1, Individual tone2 and Group tone receive data in Rx mode. 3.1 Tone Frequency range is 280 3000Hz, default 300.0Hz 3.2 Tone Duration range is 100 10000ms, default 200 ms 3.3 Gap Time range is 100 10000ms,default 200ms If Tone 2 Enable was selected, can set tone 2 in anywhere. Version 1.3 Page 10

[4] 2-Tone Super Group tone For Rx receive only in group tone. it can select tone1 or tone 2 for receive in group tone only. And can Individual tone1, Individual tone2, Group tone and Super Group tone receive data in Rx mode. 4.1 Tone Frequency range is 280 3000Hz, default 300.0Hz 4.2 Tone Duration range is 100 10000ms, default 200 ms 4.3 Gap Time range is 100 10000ms,default 200ms If Tone 2 Enable was selected, can set tone 2 in anywhere. [5] 2-Tone Tolerance Rx receive mode can select tolerance in range 1.0% - 5.0% step 0.5 for 2-tone mode. Version 1.3 Page 11

2. Tool Bar 2.1 Tool Bar mode 1 2 3 4 5 6 [1] New project (see 2.2) [2] Open project (see 2.3) [3] Save project (see 2.4) [4] Print data (see 2.5) [5] Read / Write program (see 2.6) [6] Exit program (see 2.7) 2.2 New It s new project on click. All data will set to default data setting. For model use S5 (PMR-446) the Maximum channel settings is only 8 channels for model setting. 2.3 Open Open project file will use to loading data to programming. For project file is use.bsp format only for S5 Pc Programming file 2.4 Save Save project file will use for save project file in.bsp format to save into the computer. 2.5 Print Print data will use to print Channel Frequency, System Option and 2-Tone data. The total page is 2 pages: Page 1 is Channel Frequency and Page 2 is System Option and 2-Tone data Version 1.3 Page 12

2.6 Program In this section have 2 operations: Read and Write. Read is the instruction to read data form radio for radio programming which setted in the first time. Write is the instruction to write data to radio for radio programming which setted in the first time. 1 [1] Comport setting. In the first time must click comport setting for refresh comport. 2 3 [2] Select comport to use in Read / Write program. Select the one port that the data cable was connected (auto comport if you don t had selected was COMPORT1). [3] Error comport setting. It will shown you when you have selected the comport which use in another person or program. If have some problem you can fix it yourself. * Check other program use? * Click refresh comport (see [1] Comport setting) 4 5 [4] Comport setting OK, Show comport select in status. [5] Select Read, Write and Stop button. Version 1.3 Page 13

6 11 7 8 9 10 [6] The information of Read and Write program use 1-3 steps. [7] Start Read data form radio button. [8] Start Write data to radio button. [9] Stop Read / Write program. [10] Exit Read / Write process. [11] Read / Write data process. 12 [12] Verify data. For read / write data it ll show message box. If the Read or Write data process is complete it ll show the message box in the two top picture (in red square) but if Read or Write data process isn t complete it ll shown you in message box in the two below pictures, please check you data cable and try to read or write new data radio again (follow in the information (6.)). *Note: While the processing, Read and Write buttons will be disable. 2.7. Exit Program It is the menu to exit when you click it; it ll end of process of the program and shutdown the program. Version 1.3 Page 14

3. Menu 3.1 File menu 3.1.1 New project (see 2.2) 3.1.2 Open project (see 2.3) 3.1.3 Save project (see 2.4) 3.1.4 Print data (see 2.5) 3.1.5 Exit program. 3.2 Help menu 3.2.1 Help is the section to open help file, the program use to open must be Adobe Acrobat 5.0 up. 3.2.2 About is the section is show about information of the software. 1 [1] S5 (PMR-446) PC software version. Version 1.3 Page 15