[APP NOTE TITLE] Application Profile. Challenges

Similar documents
PLANAR R54. Vector Reflectometer KEY FEATURES

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

PLANAR 814/1. Vector Network Analyzer

Reflectometer Series:

Technologies Vector Reflectometers

Impedance 50 (75 connectors via adapters)

PLANAR S5048 and TR5048

Waveguide Calibration with Copper Mountain Technologies VNA

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

ME1000 RF Circuit Design. Lab 4. Filter Characterization using Vector Network Analyzer (VNA)

1-Port VNA Series (Reflectometers)

1-Port VNA Series (Reflectometers)

RF Characterization Report

PLANAR 804/1. Vector Network Analyzer

Essentials of Fiber to the Antenna: Cable and Antenna Testing

WI-FI/BLUETOOTH & PCB TUNING AND ANTENNA TESTING

You will need the following pieces of equipment to complete this experiment: Wilkinson power divider (3-port board with oval-shaped trace on it)

FieldFox Handheld Education Series Part 3: Calibration Techniques for Precise Field Measurements

Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

Quick Site Testing with the 8800SX

LA Techniques Ltd

expanding the possibilities

EXTEND YOUR REACH GHz 60-90GHz GHz

Keysight Technologies Techniques for Precise Cable and Antenna Measurements in the Field

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Base Station Installation and Maintenance

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Amplifier Characterization in the millimeter wave range. Tera Hertz : New opportunities for industry 3-5 February 2015

Keysight Technologies PXI Vector Network Analyzer Series

Cable and Antenna Analyzer

EXTEND YOUR REACH. Copper Mountain Technologies USB VNAs. S-parameter measurement solutions from 9 khz to 110 GHz Measured parameters from S 11

54100A Series. Distance-To-Fault

Cable and Antenna Measurements Using Tektronix USB Spectrum

Keysight MOI for USB Type-C Connectors & Cable Assemblies Compliance Tests (Type-C to Legacy Cable Assemblies)

Abstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense

Basics of Using the NetTek YBA250

Keysight MOI for USB Type-C Connectors & Cable Assemblies Compliance Tests (Type-C to Legacy Cable Assemblies)

Planar Series EXTEND YOUR REACH TM

WE-525T Antenna Analyzer Manual and Specification

Ultra Wideband Indoor Radio Channel Measurements

Managing Complex Land Mobile Radio Systems

ME1000 RF Circuit Design. Lab 1. Calibration with Spectrum Analyzer

Agilent AN Applying Error Correction to Network Analyzer Measurements

Vector Network Analysis

Welcome to the Hirose MS-162A product training module. This tutorial will introduce the MS-162A series and explain its features and benefits.

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Lightning D Vector Network Analyzers. Network Analysis Solutions for Design and Manufacturing. 40 MHz to 65 GHz

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Agilent 4-Port PNA-L Network Analyzers

High-end vector signal generator creates complex multichannel scenarios

RF Components Product Catalogue

Millimeter Signal Measurements: Techniques, Solutions and Best Practices

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

Vector Network Analyzers (VERY) Basics. Tom Powers USPAS SRF Testing Course 19 Jan. 2014

Keysight Technologies PXI Vector Network Analyzer Series. Drive down the size of test

International Journal of Engineering & Computer Science IJECS-IJENS Vol:13 No:03 1

RF and Microwave Design Solutions. Bob Alman (707)

Introduction to VNA Basics PRIMER

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

Measuring the output impedance for a live PA stage

Compact VNA - TR1300/1

(a) The insertion loss is the average value of the transmission coefficient, S12 (db), in the passband (Figure 1 Label A)

JD723A/JD724B/JD726A Cable and Antenna Analyzers

S2 series. Network Analyzer Operating Manual

Pulsed VNA Measurements:

Circuit Characterization with the Agilent 8714 VNA

On site RF troubleshooting for installation and maintenance

Project Description and Guidelines

Configuration of PNA-X, NVNA and X parameters

AirScope Spectrum Analyzer User s Manual

A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER

Compact VNA - TR7530. Extended Specifications EXTEND YOUR REACH TM

Bird Model 7022 Statistical Power Sensor Applications and Benefits

Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar

Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement

Qosmotec. Software Solutions GmbH. Technical Overview. Qosmotec Propagation Effect Replicator QPER. Page 1

Radio ETI031 Laboratory Experiments 2: VECTOR NETWORK ANALYSER, ANTENNA and RECEIVER MEASUREMENTS

Analysis of RF transceivers used in automotive

PXA Configuration. Frequency range

Keysight Technologies Gustaaf Sutorius

Hot S 22 and Hot K-factor Measurements

CALIBRATION TYPES & CONSIDERATIONS

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Occupied Bandwidth Measurements (FCC Rule ) KGHP, Gig Harbor, Washington. September 26, 2012

DSI-600 EMI Test & Measurement Receiver

VSWR MEASUREMENT APPLICATION NOTE ANV004.

Keysight Technologies FieldFox Handheld Analyzers

RF Tools. Supports most 8920A, 8920B, 8921A, 8924C units

Attenuators, Couplers and Filters

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

Characterization of SPDT RF Switch (Mini-circuits MSP2TA )

RF Path Characterization

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

High Speed Competitive Comparison Report. Samtec MMCX-J-P-H-ST-TH1 Mated With MMCX-P-P-H-ST-TH1 Competitor A (Mated Set) Competitor B (Mated Set)

WIDEBAND MICROWAVE SIGNAL GENERATOR. SG24000H Compact, Low Phase-Noise, Wideband. Signal Generator Control

Vector Network Analyzers T - Series

Experiment 10 - Power Amplier Measurements Using Vector Network Analyzer

A COMPACT HIGH POWER UHF COMBINER FOR MULTIPLE CHANNELS OVER A WIDE FREQUENCY SPAN

GC723A / GC724B Cable and Antenna Analyzer

Transcription:

[APP NOTE TITLE] 03/23/2018 Application Profile Wireless infrastructure encompasses a broad range of radio technologies, antennas, towers, and frequencies. Radio networks are built from this infrastructure and from mobile radios the radios used by municipal and commercial customers to communicate over licensed frequency bands. Typical end user applications of such systems include local and regional law enforcement, highway and local maintenance dispatch, ambulance and fi re service dispatch, and federal law enforcement communications. Wireless infrastructure is often remotely located and difficult to access or may be completely inaccessible due to adverse weather conditions. It is critical to perform regular maintenance like visual inspection and RF testing of exterior cabling and antennas, and testing and adjustment of radios and combining networks. Maintenance is performed on two types of links: the RF radio networks and the microwave links that provide backhaul. Challenges Traditional network analyzers are large, heavy, and intended for use in indoor engineering laboratories or production environments. For field use, a network analyzer must overcome several limitations of traditional instruments. The VNA should be compact and lightweight, as space is limited. The instrument must also be quick to start up and begin taking accurate measurements and, ideally, recall preset test configurations to save time. Customers typically require detailed documentation following each preventative maintenance (PM) cycle, so extracting measurement results from the VNA is vital for reporting. Finally, the VNA must be programmable, so a predefined set of test results can be automatically collected and consistently saved. 1

Application: Feeder and Antenna System Return Loss Following visual inspection of exterior cabling and antennas for signs of damage or wear, testing of the RF integrity of the system signal chain is typically performed. This testing involves measurement of S11 Return Loss (RL) from the point of connection at the microwave radio up to and including its antenna. Depending on the frequency of the microwave link, the radio interface may be a waveguide, so measurement using an RF instrument with coaxial connectors requires a waveguide adaptor and use of a corresponding calibration to remove the adaptor s effects. S11 is typically measured over a much wider frequency span than the operating bandwidth of the system itself. For example, a 1 GHz or 2 GHz span may be used. Use of a wider span can help identify frequency-selective impairments which over time might impact the frequencies of interest. After S11 of the feeder system and antennas is measured, the measurement is saved and the process repeated with the instrument in a Distance To Fault, or DTF display format. The DTF measurement is based upon the same underlying RF measurements, but as the measurement result is processed through an Inverse Fast Fourier Transform (IFFT), the display shows reflection versus distance rather than versus frequency. This is helpful for troubleshooting poor return loss or for measuring the quality of specific connections and interfaces individually, all the way up to the antenna itself. The DTF measurement is also saved for later analysis and reporting. Similarly, S11 is measured from the radio transmitter interface out through the feeder network to the antenna or antennas. The result is measured and saved in both frequency and time domains, again to be later used for reporting and analysis. RF Duplexer Testing and Adjustment Another key test performed during PM is characterization and adjustment of any frequency-tuned components in the transmitter chain. Tuned devices are prone to drifting slightly over time and temperature, but even more critically, as radio networks evolve channels may be added or removed, or changed in frequency, necessitating adjustments. For these reason, it is highly advisable to confirm proper adjustment of any tuned combiners when performing PM. Specifically, in the case of RF combiners such as those shown at right, the passband frequency of each combiner input can be adjusted independently. In the example shown, two 4-way combiners combine 5 channels to two antenna feeders; three channels are combined by one combiner and 2 channels are combined by another device. Unused combiner inputs should always be terminated as a best practice. 2

Automation and Programming Markers positioned at specified frequencies during combiner testing A two port VNA, the Planar 304/1, is used to adjust and measure each combiner. VNA Port 2 is connected to the combiner output in place of the antenna feeder and VNA Port 1 is connected to one of the combiner inputs in place of the radio output. Markers are moved to the operating frequencies of all channels on the combiner, to facilitate measurement of the parameters values at a glance. All four S-parameters are measured with markers in place. S11 return loss magnitude the amount of power reflected back into the radio should be below some threshold maximum to ensure a good match from the radio output to the combiner. A pass/fail value for return loss might be -18 db RL, with values of -21 db or even -22 db being quite attainable. Similarly, S22 return loss is compared against some threshold at the nominal operating frequency of each transmitter, perhaps with a -15 db goal. Because the markers have been pre-positioned at the frequencies of interest, the return loss values can be readily determined from the marker table, as shown at left. With the VNA Ports 1 and 2 connected to combiner Input 1 and Output, respectively, S11 return loss at the transmit frequency of radio 1 can be readily found to be -20.921 db. S22 return loss is -17.430 db in this case. With respect to Thru parameters, S21 represents the loss through the combiner from Input to Output, and should be less than 3.0 db loss as a goal; in this example, there is a 2.36 db loss. And finally, S12 is measured for operating frequencies other than that of the input being tested, to ensure that power reflected 3

back into the combiner is attenuated sufficiently. Here the values are found to be -72.1, -66.7, -72.0, and - 82.3 db respectively, all acceptably low values. In this particular scenario, there are no necessary adjustments to the combiner, so the test result can be saved for later reporting and analysis. Common adjustments include minor changes in the tune frequencies of each channel s path to compensate for drift over time and temperature, as well as moving the tune frequencies of each unused combiner input away from the frequencies of the active channels, to prevent it interfering with the desired response. Test Result Saving and Reporting Saving these various test results and integrating those results into test extensive reports is a critical and frequently time-consuming aspect of the overall PM process. Copper Mountain Technologies VNAs incorporate numerous options for saving and exporting of results. These options can be divided into two types of saving: formats which include the actual test data underlying the display, and those which do not. The appropriate saving method can be chosen according to the specific process followed in a given scenario. For example, in cases where the raw test data is required for post-processing, data can be saved in State, CSV or Touchstone formats. Saving as a CSV file allows the data to be readily opened in Excel or any spreadsheet or data processing application. Additional information like the axis data, marker locations, or limit lines are available in the State format. State saving utilizes a proprietary file format, but allows the measurement to be recalled by the VNA application for display, either to the active trace or to the memory trace; the latter enables comparison in the VNA program between past results and live results. Finally, the Touchstone format saves all four S-parameters (S11, S12, S21, and S22) in an industry-standard file format (extension S2P ) which can be opened and manipulated by the VNA application or by any number of third party analysis and reporting applications. In other cases, the displayed results at the exact time they are saved may be needed in the report. In this case, saving the underlying data and re-plotting it for reporting is unnecessary; the user can use the Print function to save results. CMT VNA software supports three Print methods: Windows, System, and Word. The Windows print method opens a standard Windows Print dialogue box allowing for selection of a printer, paper orientation, and so forth; it is ideal when a hard copy or PDF of the result is needed directly from the application. The Print System method saves the current measurement result as a.png image file, which can be attached to an email, copied into a report, or organized and archived by filename. Word printing creates a Microsoft Word document and inserts the current test result as an image, which can be dropped into a customizable template that will automatically incorporate the date and time of the test, serial number of the analyzer, a company logo, and more. 4

Programmability CMT VNAs are fully programmable using industry-standard SCPI commands over a COM interface. The PC-based user interface program acts as a COM server, to which clients can connect to send commands and retrieve measurement results. The software installer includes examples of automation routines in VBA (Excel macro), MATLAB, C++, and LabView. Users can use these examples to incorporate their own commands to customize the automation routines. For wireless infrastructure testing, automation can be very useful when the instrument is shared among newer personnel who may not have extensive RF background training. If there are standardized tests performed at each location, the instrument setup and saving of test result can be automated to reduce test times and minimize opportunities for operator error. Summary: Advantages of CMT Planar 304/1 Performing regular preventative maintenance of wireless infrastructure is a critical step in ensuring yearround, reliable operation of these stations. PC-driven VNAs are ideally suited for such applications because of their compact, lightweight form factors, ease of reporting and result saving, measurement accuracy, and programmability. 5