AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

Similar documents
LK Wireless Room Control Cq

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Smart Power Relay E I...

NRT 105: Electronic fan-coil controller, equiflex

Electronic Circuit Breaker ESS1 for System SVS1

JUMO Wtrans Receiver with Wireless Data Transmission

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

PHOENIX CONTACT - 09/2009

Electronic Circuit Breaker ESS20-0..

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Technical data. General specifications. Measurement range min max. 360

Instruction manual SMART 96-2 / WG-2 ph

Electronic Circuit Breaker ESS1 for System SVS1

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Fan Coil Actuator FCA 2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

INFO-PTr. PT-100 Measuring Card. PT-100 Temperature Measurement. Technical Data

Datasheet - PROTECT-IE-02

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Output of three-phase motors at 50 Hz and 400 V

Type CP-S, CP-C & CP-A Switch mode

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

QUINT-PS-24DC/24DC/10

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

Control solutions Biofloor

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

Electronic Circuit Protector ESX10

EIB/KNX Switch Actuators. User manual

Wireless multizone receiver RDE-MZ6

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

Electronic Circuit Protector ESX10-T

Short operating instructions

RMO500 M I C R O O H M M E T E R

DIGEM f 96 x 48 EK. Applications. Description

Sentry Digital Timers

IMPULSE SWITCH, REMOTE SWITCH

Micro-controller X Model: PXE4. Operation Manual. INP-TN5A1887a-E

DTH-14. High Accuracy Digital Temperature / Humidity Sensor. Summary. Applications. Data Sheet: DTH-14

Electronic Circuit Breaker with reset input ESS20-1..

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Technical Information itemp TMT180

Level Switch NRS 2-50 NRS Original Installation Instructions English

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

Room Temperature Controllers. for heating and cooling systems

AEROCONNECT 1B NA C Control manual

PHOENIX CONTACT

! "! # $ % & ' ( ) " * % +, # # -. / ( ! " ! # $ % &

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

US2, US4, US6 Electronic step controllers

Operating instructions Electronic level sensor LK / / 2008

Wireless Room Thermostat Installation and Operation Y6630D1007

EY-EM 527: Remote I/O module, ecolink527

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

CAMTO. Arc detecting relay. system. January Revised August D D1200

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Paperless Recorder PR20

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Operating Instructions

Microprocessor-based Temperature Controller

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Instruction manual SMART 96-2 / WG-2 LF

Electronic Step Controller

650 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Operating Instructions

Remote Switching Unit nivotester FTL 320

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Outside Temperature Sensors

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

RCMS460 and RCMS490 Series

Room Temperature Controllers. for heating and cooling systems

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

Technical Documentation

CONTROL MANUAL. Dry-Pic 09PE - 09VE

Functional data Factory settings Variable Settings

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

MODEL SS - DIN-RAIL SPEED SWITCH

Contents. English User Manual Regulators

PHOENIX CONTACT

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

EFC 3600 Frequency converter for higher energy efficiency and improved process control

Universal Controller

Owner's Manual Applications & Operating Instructions, Trouble-shooting, Specifications & Warranty

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

LED Driver Compact dimming

A new approach to static electricity countermeasures

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Datasheet. Electronic Circuit Protection ESX10-T

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Electronic circuit breaker ESS30-Sxxx-DC24V

Transcription:

Dewpoint-guided Power Controller for Glass and Handrail Heaters Front view Characteristics Dew point-guided power controller for cost-optimized operation of glass and handrail heaters Digital display of market temperature, relative humidity, dew point and duty cycle Four phase-delayed outputs for every two solid state relays ECA970 Equal distribution of current loads Eight different control characteristics per channel for all of the current refrigerator types Adjustable minimum duty cycle per channel Good temperature consistency through 7 switchings per hour Saving of extensive statistical functions for data evaluation Graphic representation of power consumption of the FRIGODATA XP Simple parameter changes via clear text menu and direct operation Outlet for CAN interface for remote data transmission Fast installation by snapping onto profile rail Plug-in connection terminals _00-0_EN Subject to technical revisions Page of 9

Table of Contents Page Connection diagram with ECA970 Principle of function Operation Individual parameters per channel 5 Actual values 5 6 Interface for remote data transmission 5 7 Monitoring 6 8 Start-up 6 9 Menu format 7 0 Installation 9 Technical data 9 Connection diagram with ECA970 L N L N max. pc. max. pc. NT + - ECA970 ECA970 +A -A +A -A CAN-bus module 9 8 7 6 5 L characteristic AHC - XP alarm priority address - + +U 5 6 7 8 5 6 n.c. 7 8 9 5 CAN-H n.c. CAN-L GND others ECA970 N channel channel channel channel Do not wire! 0V ambient temperature rel. humidity % dew point duty cycle DC% menu -0mA 0-00%rF ambient temperature relativ air humidity Page of 9 Subject to technical revisions _00-0_EN

Principle of function The technical data for refrigerators must be determined in accordance with EN in climatic rooms, where the climate classes for a room temperature of 5 C and a relative air humidity of 60% must be adhered to. Climatic conditions, in which the air is very moist and warm, can only be found on a few days out of the year in Northern Europe, however. Despite this fact, the refrigerators and therefore the anti-condensation heaters of glass and handrails are designed for this unfavourable situation. For the few remaining days where the air is cooler or drier, the capacity of these heaters is then too high. The operating costs can be reduced by up to 70% by means of dew pointdependent capacity control. The possible level of capacity reduction (down to zero) is determined by the controller and relayed to solid state relays ECA970 by the respective control commands. The heaters thereby periodically switch off for several seconds without making contact and thus wear-free just as long as possible, so that the dew point on the refrigerator surfaces is not fallen short of. Operation The controller has a -digit digital display, two buttons for adjusting the set values and a menu display with menu button to change the menu position. After the unit is switched on, all LEDs are illuminated briefly as a function control. Then the standard menu Temperature Tu is indicated by the corresponding menu LED. The current temperature is displayed on the digital display. The menu button must be pressed briefly for each menu change. The menus are called up in order from top to bottom, first the left and then the right column. Each menu selected is indicated via a menu LED. In standard mode it is not possible to adjust the values shown in the display. Some parameters are on the so-called nd operating level. To change to this level, the menu button must be pressed and held down for 5 seconds. This can be done for each currently selected menu position. The nd operating level is indicated by slowly flashing menu LEDs (approx. Hz). Not all positions on the nd operating level contain information that can be requested. For this reason, menus without content are skipped when scrolling with the menu button. If no other button is pressed within two minutes of last actuating a button, the display will automatically revert to the standard menu on the first operating level. For the, the standard menu is the display of the temperature Tu. It is also possible to return to the st operating level by pressing the menu button again for 5 seconds. To adjust the set values, it is necessary to activate access. To do this regardless of the menu selected, the menu, plus and minus buttons must all three be pressed simultaneously for 5 seconds. Activated access is signalled by means of rapidly flashing menu LEDs (approx. 8 Hz). In the nd operating level, the rapid flashing is overridden by slow flashing. In this case the LED flashes briefly times followed by a longer pause. _00-0_EN Subject to technical revisions Page of 9

Individual parameters per channel The set values may be adjusted using the plus or minus button. Briefly pressing this button adjusts the value by just one step at a time. If one of the buttons is pressed for a longer period of time, the values are changed at increasingly short intervals (dynamic autorepeat function). This makes it possible to adjust the values more quickly. When the menu or menu levels are changed, access need not be cleared again to be able to adjust other set values. Actual values are displayed only and cannot be adjusted in this way, even when the corresponding menu LED is flashing. Automatic reversion to the standard menu after the time out period of minutes also blocks access again. The menu LED is again constantly illuminated. If other values are to be adjusted, access must again be activated as described above. Access can also be blocked again by again pressing the three buttons menu, plus and minus simultaneously for 5 seconds. When in the position Duty cycle DC% of the respective channel, manual operation is activated by pressing the Plus button for more than 5 seconds. In this way, the corresponding heater will be controlled for two hours with 00% DC. After these two hours have passed, the channel reverts back to normal control. The assigning of parameters to the menu positions is described in section 0. Characteristics curve The temperatures of the glass and metal surfaces of refrigerators must always be higher than the current dew point. Since the cooling of surfaces by the refrigerator itself has different levels of effect and depends on the temperature of the goods, the characteristics curve of the controller channel must be adjusted to the type of refrigerator. In order to significantly reduce the amount of time necessary for the refrigerator installer to spend on testing out the setting values Increase and Zero offset, we have investigated typical refrigerators and saved the characteristics curves in the controller. Cold location / Function 0 No control of outputs TK glass door cabinets for ice cream (-/- C) TK glass door cabinets normal (-8/-0 C) Glass enclosed TK islands for ice cream (-/- C) Glass enclosed TK islands - normal (-8/-0 C) 5 TK islands, not glass enclosed, for ice cream (-/- C) 6 TK islands, not glass enclosed, normal (-8/-0 C) 7 Wall shelves and service counters (+0 /+ C) 8 Wall shelves and service counters (+ /+6 C) 9 Continuous operation 00% duty cycle Page of 9 Subject to technical revisions _00-0_EN

Minimum duty cycle (Min %DC) Since the heating powers of glass and/or handrail heaters have recently been reduced somewhat by the refrigerator manufacturers, an adjustable minimum duty cycle for each channel is provided here. By changing the minimum duty cycle (range: 0 90%), the refrigerator installer can adjust the steepness of the set dew point characteristics curves to the changed conditions. Relative duty cycle as a function of the dew point temperature (Parameter: minimum duty cycle) 5 Actual values The assigning of parameters to the menu positions is described in section 9. Temperature Tamb. Provides the current reading of the temperature probe. Rel. humidity The current reading of the relative air humidity in %. Dew point The dew point temperature calculated from the temperature and humidity. This value is the reference value for determining the channel-specific duty cycle. Duty cycle %DC The current duty cycle of each channel is shown in positions -8 of the operating level. The display is in % of DC. 6 Interface for remote data transmission The controller can as an option be equipped with a CAN BUS interface. To do so, a BUS CAN plug is plugged into the outlet for the interface. To communicate and record values with a master system then requires a gateway and FRIGODATA-XP software. The device records the market temperature, the relative humidity, the calculated dew point and the duty cycle of each channel. Using the FRIGODATA XP software package, this data can be read and displayed. _00-0_EN Subject to technical revisions Page 5 of 9

All operating parameters can be displayed and remotely adjusted. Two green light-emitting diodes on the bus connection signal the data transfer of the device. To participate in the data transfer on the CAN Bus, a unique address between and 0 must be assigned to the device. If the address assignment is 0, bus communication is switched off. 7 Monitoring 8 Start-up If there is a fault, the display flashes, showing the code given in the following table and the value of the menu to be displayed. Error F F C0LL Uhr bus EE Monitoring function Probe faults Short circuit/break of temperature probe. The controller is in emergency operation. Probe faults Short circuit/break of moisture probe. The controller is in emergency operation. Collision Address collision on the bus, Another device with the same device address has been found. Clock fault The internal software clock has not yet been reset after the re-start of the device. Communication to the Gateway is defective. Bus fault, general communication fault Data loss, A power surge may destroy the set values. Remedy: Enter all storage locations again; switch controller without current The entire wiring must be checked before start-up. First, the displayed values for room temperature and humidity must be checked and if needed, the installation location and wiring of the sensors must be checked. Following this, the respective characteristics curve (see section ) must be selected for each control channel. If nothing is known about this at the time of the control cabinet inspection, characteristics curve should be entered for all channels. Using a control lamp (not a glow lamp or multimeter!), the cycling of the glass and handrail heaters can subsequently be checked. To do so, the control lamp is connected parallel to the consumer load. To test the heaters, while still in the position Duty cycle %DC of the respective channel, manual operation can be activated by pressing the plus button for more than 5 seconds. In this way, the corresponding heater will be controlled for two hours with 00% DC. After these two hours have passed, the channel reverts back to normal control. Data communication should still be checked following this by means of remote data transfer. Page 6 of 9 Subject to technical revisions _00-0_EN

9 Menu format Setting parameters of the st operating level ambient temperature rel. humidity % dew point characteristic AHC - XP duty cycle DC% menu alarm priority address - + Activating the adjustment LED flashes fast (approx. 8Hz) Setting the parameters M => 5 sec. - After all buttons are pressed simultaneously for 5 seconds, set values can be set in the st operating level. M Select the parameter + - + Change value The controller automatically reverts back into the initial position Temperature Tamb. after minutes if no adjustment is made.. Operating level (standard) Menu Description Min Max Ex Factory left column Temperature Tamb. Ambient temperature Rel. humidity % relative air humidity Dew point calculated dew point - - Duty cycle DC% Current duty cycle channel Duty cycle DC% Current duty cycle channel Duty cycle DC% Current duty cycle channel Duty cycle DC% Current duty cycle channel Manual operation: Select channel <+> Press 5 sec. => -hours continuous operation right column Characteristics curve Refrigerator characteristics curve channel 0 9 Characteristics curve Refrigerator characteristics curve channel 0 9 Characteristics curve Refrigerator characteristics curve channel 0 9 Characteristics curve Refrigerator characteristics curve channel 0 9 - - Time System time Alarm priority Alarm priority of device 0 Address Device address on the CAN-Bus 0 0 0 _00-0_EN Subject to technical revisions Page 7 of 9

Setting parameters of the nd operating level ambient temperature rel. humidity % dew point characteristic AHC - XP duty cycle DC% menu alarm priority address - + Switchover to the nd operating level LED flashes slowly (approx. Hz) Activating the adjustment LED flashes slowly and overrides fast (approx. Hz + 8 Hz) Setting the parameters. Operating level => 5 sec. M M => 5 sec. - After all buttons are pressed simultaneously for 5 seconds, set values can be set in the nd operating level. Select the parameter Change value The controller automatically reverts back into the initial position Temperature Tamb. after minutes if no adjustment is made. Imprint on front plate Menu Description Min Max Ex Factory left column Temperature Tamb. Plot cycle Time slot pattern for storing the 5 5 measured values in minutes Rel. humidity % - Dew point - - - Duty cycle DC% Min. DC % Minimum duty cycle channel 0 90 0 Duty cycle DC% Min. DC % Minimum duty cycle channel 0 90 0 Duty cycle DC% Min. DC % Minimum duty cycle channel 0 90 0 Duty cycle DC% Min. DC % Minimum duty cycle channel 0 90 0 right column Characteristics curve - Characteristics curve - Characteristics curve - Characteristics curve - - - Time - Alarm priority Outputs Status of control outputs Address Version installed software version The setting values have another function in the nd operating level than the texts printed on the front plate! + M - + Page 8 of 9 Subject to technical revisions _00-0_EN

0 Installation The device is designed for profile rail mounting. The housing is a standard size and is also suitable for installation in fuse boxes. It can be positioned immediately next to another without gaps. Standard xx0.8ø telephone cable is recommended for wiring data lines up to 00 m in length. The protective shield must be grounded in the control cabinet. For cable runs between 00 m and 00 m, sheathed cable with braided sheathing should be used. For probe extensions, it is recommended that the following sheathed cable be laid. 90 06 Cable run up to 00m up to 00 m Diameter 0.75 mm².5 mm² 5 58 dimensions Technical data Supply voltage 0VAC +0% / -0% Power draw approx. 5 VA Fusing max. 6A Temperature probe Type TRK77PLUS Moisture probe Type RHS950 Switch outputs Optocoupler output for controlling every two solid state relays ECA970 Low-voltage protection The device is not suitable for low-voltage protection. Central processing unit Single-chip microcomputer, data memory Monitoring system Monitoring of connected probes Self-monitoring of data memory and microcomputer Communication Optional CAN-bus interface Internal time Measuring system time from the Gateway (only for application in the BUS system) Without power reserve in case of power failure. Dimensions (WxHxD) 06 x 90 x 58 mm³, DIN 880 Mounting Mounting rail DIN EN 500 5x5 Ambient temperature 0...+5 C Weight approx. 50 g Low-voltage protection The device and the outputs are not suitable for low-voltage protection (SELV). EC Conformity Declaration As defined by EC Directive on Electromagnetic Compatibility 89/6/EEC This document will automatically become invalid when superseded by a new technical description of the device. _00-0_EN Subject to technical revisions Page 9 of 9