ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER TRANSFORMER

Similar documents
ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 04, 2014 ISSN (online):

Chapter 7 Conclusion 7.1 General

New Method for Transformer Winding Fault Detection

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

Importance of Transformer Demagnetization

Field Experience with Sweep Frequency Response Analysis for Power Transformer Diagnosis

Picture perfect. Electromagnetic simulations of transformers

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

NUMERICAL MODEL OF THE 10 KVA TRANSFORMER WITH COPPER WINDINGS

Fault Detection in Transformer Using Frequency (Sweep) Response Analysis

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Research Article A Simplified High Frequency Model of Interleaved Transformer Winding

Regional Technical Seminar SHORT CIRCUIT FORCES

Analysis of Frequency Response measurement results with end-to-end/interwinding test setup correlation

Regional Technical Seminar SHORT CIRCUIT FORCES

Transformer Winding Deformation Analysis using SFRA Technique

Transformers handling and transport

Vallabh Vidyanagar, Anand, INDIA

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

Department of Measurement and Applied Electrical Engineering RESEARCH ACTIVITIES

Transformer Engineering

Matz Ohlen Director Transformer Test Systems. Megger Sweden

Research Article Transformer Winding Deformation Profile using Modified Electrical Equivalent Circuit

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Power Transformer Condition Assessment Based on Standard Diagnosis

Ferroresonance Experience in UK: Simulations and Measurements

Investigation of PD Detection on XLPE Cables

Demagnetization of Power Transformers Following a DC Resistance Testing

NON-DESTRUCTIVE TESTING OF ARTIFICIAL JOINTS WITH DEFECTS BY EDDY CURRENT METHOD

ANALYSIS OF OPERATION MODE AND PERFORMANCE INDICATORS OF A TRANSFORMER WHEN CONTROLLING ITS VOLTAGE WITH AN ALTERNATING MAGNETIC FLUX

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

Benefits of SFRA - Case Studies

متلب سایت MatlabSite.com

(2) New Standard IEEE P (3) Core : (4) Windings :

TesTIng of Power. Transformers are the largest, most. feature. By brandon dupuis

Loss prophet. Predicting stray losses in power transformers and optimization of tank shielding using FEM

Lumped Network Model of a Resistive Type High T c fault current limiter for transient investigations

Magnetics Design. Specification, Performance and Economics

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Transformer Technology Seminar What to consider at Design Reviews

Contents. About the Authors. Abbreviations and Symbols

Variation in SFRA plot due to design and external parameter

Diagnostic testing of cast resin transformers

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Assessment of Winding Deformation in Power Transformer using SFRA and Numerical Techniques Ashwini Bhujangrao Gaikwad

Earthing of Electrical Devices and Safety

Transformer Shunt Fault Detection using Two Techniques

AGN 034 Alternator Reactance

Understanding and Extracting Valuable Information from Basic and Advanced Power Transformer Testing Techniques

Specialists in HV and MV test and diagnostics. Testing in Substations

TRANSFORMER TECHNOLOGY GPT

INTERPRETATION METHODOLOGY TO IDENTIFY FAULT LOCATION IN A POWER TRANSFORMER

FRAX Series Sweep Frequency Response Analyzers

ABB September Slide 1

TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING

Transformer Technology Seminar Winding Selection

Resonant Mode of Inductors with Reactive Power Self-compensation

TECHNICAL BULLETIN 004a Ferroresonance

AGN 005 Fault Currents and Short Circuit Decrement Curves

NEW DEVELOPMENTS IN FLUX MONITORING FOR TURBINE GENERATORS. M. Sasic, B. A. Lloyd and S.R. Campbell Iris Power LP, Mississauga, Ontario, Canada

HOW TO SAFE GUARD THE TRANSFORMER..???

FAULT IDENTIFICATION IN TRANSFORMER WINDING

Corona noise on the 400 kv overhead power line - measurements and computer modeling

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

APPENDIX 4 TYPICAL LAYOUT, VALUES AND CONSTANTS

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

AN ANN BASED FAULT DETECTION ON ALTERNATOR

EXPERIENCE WITH DETECTION AND IDENTIFICATION OF WINDING BUCKLING IN POWER TRANSFORMERS. Victor V. Sokolov and Boris V. Vanin ZTZ-Service Company

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

Fault Indicators of Partial Discharges in Medium-Voltage Systems

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

Effective Maintenance Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

Analysis of metallic ropes magnetisation during magneto-inductive testing

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser - OMICRON

A Practical Guide to Free Energy Devices

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT

Power Transformer Failures Evaluation Using Failure Mode Effect and Criticality Analysis (FMECA) Method

3Ø Short-Circuit Calculations

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Transformer Protection

Electromagnetic Force Modification in Fault Current Limiters under Short-Circuit Condition Using Distributed Winding Configuration

BASIC PROBLEMS AND SOLUTION OF THE ENCAPSULATION OF A LOW VOLTAGE SPARK GAP WITH ARC SPLITTER CHAMBER

Lifetime Consumption and Degradation Analysis of the Winding Insulation of Electrical Machines

High-frequency Transformer Modeling for Transient Overvoltage Studies

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

B3-102 THE ROMANIAN EXPERIENCE REGARDING THE RISK OF MANAGEMENT IN THE OPERATION AND MAINTENANCE OF LARGE POWER TRANSFORMERS IN HV SUBSTATIONS

TIGHTENING TORQUE ON WOODEN CORE CLAMP (Nm) (STEEL FASTENER) 1 M M M M M

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

7. INSPECTION AND TEST PROCEDURES

Life Prediction of Mold Transformer for Urban Rail

Electrical Design Process

Transcription:

ANALYSIS OF TRANSIENT ACTIONS INFLUENCE IN POWER TRANSFORMER Jozef JURCIK 1, Miroslav GUTTEN 1, Daniel KORENCIAK 1 1 Department of Measurement and Applied Electrical Engineering, Faculty of Electrical Engineering, University of Zilina, Univerzitna 1, 010 26 Zilina, Slovakia jurcik@fel.uniza.sk, gutten@fel.uniza.sk, korenc@fel.uniza.sk Abstract. This article is focused on the theory of unacceptable effect on transformer winding, mainly the overvoltages and the mechanical forces. In the next part of the article is described the measurement of selfdischarging voltage frequency dependence on transformer. The second measurement shows one of the possible type of SFRA method. The measurement results lead us only to the conclusion that some changes of the winding condition have occurred. Keywords Short-circuit, coil, transformer, winding, axial forces, radial forces, SFRA method. 1. Introduction During the operation of transformer, different states, with dependences on their function can be created. The transient actions (short-circuits and overvoltages) had main dependence on transformer insulation (coil varnish, paper and oil). Forces, which have mechanical effect on winding occur. In this case, the paper nuzzles and coil varnish are destroyed. Discharges changing the structure of oil appear in overvoltages. The transient actions in transformer are created by each operation state change, connection the transformer on electrical power network, at fast load change, in shortcircuit in network and the like. The electromagnetic effects have the influence on a transformer winding in transient actions, which need to analyses with special analyze, because they had serious importance for design and operation of transformer. 2. Short-Circuits Currents Effect on Transformer Winding The short-circuits in operation are commonly created by different line faults, etc. in mechanical damage of insulation, electric insulation, electric insulation breakdown on over voltage, wrong operation and in a next case row. Meaning of the short-circuit is serious disrepair for the transformer, because there are high currents in it which are awfully rising winding temperature which can damage their insulation in affect. Much more dangerous are the high electro-magnetic forces, which might occur due to the devastation of transformer. Figure 1 presents a transformer with winding damaged by short-circuiting forces. In such case the transformer winding and its coils must be structural and stable so it can tolerate high mechanical forces without the damage, which is created by short-circuits. In the transformers with self-cooling with aluminum, winding is necessary to prevent the unavoidable breakdown in operation time. In such case the choice of correct diagnostics is crucial to foresee the state. Fig. 1: View for defective transformer windings affected by shortcircuits currents. The measure is based on two methods of monitoring and analyzing as well as their association for better identifies the most reliable image of the effects of short-circuit currents on transformer winding in operating time: 2011 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING 65

monitoring of change of short-circuit voltage (impedance), monitoring of impedance or winding attenuation depending on the frequency by SFRA method, analysis of a winding state of winding phases and their correlative equation, e.g. by means of selfdischarging voltage method. The state of the percentage changes in shortcircuits voltage or impedance depending up frequency is the geometrical winding movement reflexing and their construction in transformer. The change of this state depends on thermal and mechanical effects of short circuit currents. For a better comprehension of the relation between transformer damage and short-circuits currents effects, one must focus on the effect of mechanical forces on transformer windings during short circuit. 3. The Theory of Mechanical Forces Effect on Transformer Winding During Short-Circuit The primary cause of the appearance of forces, which affect the winding is the magnetic field influence on current flowing conductors. As to the transformer it is the field of stray flux. 3.1 Action of Radial Forces in Winding Radial forces F q are a result of lengthwise fields, which are paralleled to axis of transformer winding. These forces are dilating external windings and compressing internal windings, as a consequence air spaces are bigger. The lines of force of magnetic stray flux are parallel with axis of winding and similar to the effect of radial force on the each coil. The summaries of radial forces, which are signed as F, lead to the increase of the space between windings (Fig. 3). Infinite small change of magnetic field energy adequate to the infinite small rising space. w F, from Magnetic fields energy: F w. (1) 1 w i 2 1 X z, (2) 2 2 f where: i current momentary value in windings, X z leakage reactance in short of the windings, f frequency, so, force formula is: w 2 lstr 7 F = 2 ( it) 10, (3) L where: (it) coil ampere-turn, l str average winding length in, L u is height of winding. u Fig. 3: Radial forces Fq (F ) effect on transformer windings. Fig. 2: Mechanical forces effect on transformer winding: a axial forces affect, b radial forces affect, c normal winding (without force affect). Under the state of normal operation, when the currents in transformer do not exceed rating value, the forces effecting on winding are generally of low level. But in short-circuits, when the currents reach the multiple of rating values, these forces can become dangerous for the windings or the confirmative construction. We can divide forces affecting the windings into two groups (Fig. 2): radial (cross), axial (longitude). 3.2 Action of Axial Forces in Winding The axial forces rise from the center to border of winding, where the magnetic field has the biggest cross component. In short-circuits axial forces can reach dangerous, so they can deform outer coil. As to asymmetric windings axial forces are dangerous. The forces which are created by a small displacement of both coils, try to make this displacement bigger. This displacement can be created by coils which are not totally similar. The asymmetry can be also created by insulation of high voltage coil due to the fact that there are more insulators than in the lower voltage coil winding. But there is a possibility of the retraction of any side of insulation in adequate coils. This retraction can by caused by drying-out. 2011 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING 66

According to [2] one needs to pay more attention to catching outer coil. In case of released coil, the axial forces F d (Fig. 4) can cause displacement of outer coils to the vertical sides (Fig. 4 shows the origination of empty spaces). The redundant pressure of spacers can press insulation and move winding, which can cause serious damages of transformer. Fig. 4: The pressurize the coil conductors by excessive effect of axial forces pressing. (influence on the deformation of insulation). 4. Experimental Analyses 4.1 Self-Discharging Voltage Method Senses self-discharging voltage is highly sensitive method which is based on assessment of the quality changes of material aftermath operational aging [5]. After closed defined time of the inter-coil capacitance charge the transformer is unplugged from DC supply and we measure discharging process of winding insulation through leakage resistance. Faster decreasing of self-discharging voltage is caused by smaller value of insulating resistance. Discharging process is affected by irreversible degree of degradation of material too. The graph of voltage on inter-coil capacitance of transformer after unplugging is showed on Fig. 5. Discharging time is grows with rising quality of insulation of windings. We can observe differences between each phases of transformer in t 2 time in this measuring. This difference between transformer phases is an important sign of degradation of state of winding insulation by short-circuits currents effect in main. We checkup 9 randomly selected transformer, which was used in distribution network with power in range from 30 kva to 1 MVA and we acquire discharging time for each phase (Tab. 1). The results of measurements were partial image of short-circuits stresses of transformer in operating time. Coils were not changed before test. In Tab. 1 are values obtained by measuring the self-discharging voltages on primary HV coils. Comparison of the different phases shows asymmetry of quality of insulation on transformers 1 and 4. Tab.1: Results of discharging time measurement. No. Type S A-B A-C B-C IΔt v.100i Note 1 2 3 4 5 6 7 8 9 kto 253/22 334/22 334/22 374/22 374/22 kto 350/22 kva t v (s) (%) 30 48 34 48 21,54 *a 100 98 82 96 10,87 100 114 98 103 8,57 100 103 131 156 20,77 *a 250 152 131 159 11,09 400 68 71 69 2,40 630 135 107 123 12,05 1000 76 60 63 14,57 400 165 165 171 2,40 *a huge inter-coil difference Fig. 5: The discharge process of transformer after disconnection from DC supply. 4.2 SFRA Method SFRA (Sweep Frequency Response Analyzer) method belongs to current most effective analyses and allows detection the influences of short-circuit currents, overcurrents and other effects damaging either winding or magnetic circuit of the transformer. This all can be performed without the necessity of decomposition of device and subsequent winding damage determination, which is very time-consuming. SFRA as a one of the most predictable methods, can be based on passive parameters measurement method 2011 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING 67

depending on frequency 20 Hz 200 khz (see Fig. 6 and 7 - measured values for distribution transformer 22/0,4 kv). Fig. 8: Dependence of tg on frequency which was measured for transformer 22/0,4 kv. Fig. 6: Dependence of impedance in frequency, which was measured for transformer 22/0,4 kv. During these measurements are detected a mechanical states of tested winding and ferromagnetic core. The obtained curves typical for this measurement provide the important information about changes in the core, which are visible in low frequencies, while higher frequencies are linked to problems such as winding movements or turn-to-turn fault. Fig. 7: Dependence of capacity on frequency which was measured for transformer 22/0,4 kv. The application of analysis of phase or tg (dissipation factor) attenuation depending on frequency (Fig. 8) is suitable for more complete evaluation of winding condition. This analysis enables to assess the processes of winding movements during the particular short-circuits influences. 5. Conclusion A relation between the response and the winding condition is definite, otherwise it is complicated. It is impossible to expect the assessment of concrete damage of winding from differences in response behaviors. The measurement results lead to the conclusion that some change of winding condition really occurred. Such test results are very helpful to decide, whether it is unavoidable to open and revise the transformer or not. The state of the response depending up frequency is the image of geometrical winding movement and their construction in transformer. The change of this state depends on thermal and mechanical effects of short circuit currents. Problem of the frequency analysis of transformers by SFRA method is very comprehensive and its application becomes interesting for many transformer manufacturers and operators. From the long-term point of view the SFRA method is supposed to be very useful and it provides enough information on tested transformers. These transformers have their reference data obtained by the manufacturers, suitable for the comparison with further data of particular transformer. SFRA testing method represents one of the most effective alternative diagnostic methods compared to visual check. This method allows to detect the effects of the short-circuit currents, whereas we are able to evaluate the mechanical strength action on the transformer winding during previous operation It is also possible to identify the specific winding phase, which has been mostly influenced by the short-circuit currents, without a necessity of transformer dividing, which would be very time consuming. 2011 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING 68

Acknowledgments This work was supported by the Grant Agency VEGA from the Ministry of Education of Slovak Republic under contract 1/0548/09. References [1] HUYNEN, I.; VANHOENACKER-JANVIER, D.; VANDER VORST, A. Spectral domain form of new variational expression for very fast calculation of multilayered lossy planar line parameters. IEEE Transactions on Microwave Theory and Techniques. 1994, vol. 42, no. 11, pp. 2099-2106. ISSN 0018-9480. [2] GUTTEN, M.; KUČERA, S.; KUČERA, M.; ŠEBÖK, M. Analysis of power transformers reliability with regard to the influences of short-circuit currents effects and overcurrents. Przegląd Elektrotechniczny. pp. 62-64, Vol. 85 No. 7/2009. ISSN 0033-2097. [3] JAROUŠEK, J.; PLENCNER, R. Transformátory. SVTL Bratislava, 1961. [4] JEZIERSKI, E. Transformátory : Teoretické základy. Academia Praha, 1973. [5] PETROV, G. N. Elektrické stroje 1. : II. Transformátory. Academia Praha, 1980. [6] GUTTEN, M.; MICHALÍK, J. Metodika overovania účinkov skratových prúdov na vinutiach výkonových transformátorov. ADVANCES in Electrical and Electronic Engineering. 2002, vol.1, no. 1, pp. 28 32. ISSN 1336-1376. [7] ŠEBÖK, M.; KUČERA, S.; KUČERA, M. Diagnostics of electrical equipment using radiance sensors. Proceedings of the 7th International Conference Elektro 2008. Žilina, ISBN 978-80- 8070-845-0. About Authors Jozef JURCIK was born in Povazska Bystrica. He graduated at University of Zilina as M.Sc. in Power electronic systems in 2010. He acts on Department of Miroslav GUTTEN was born in Zilina. He graduated at He acts on Department of Daniel KORENCIAK was born in Zilina. He graduated at He acts on Department of 2011 ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING 69