Franco Rusnati Responsabile tecnico
Flicker (IEC/TR 61547-1) ed effetto stroboscopico (IEC/TR 63158) Modalità non attiva dei prodotti e misura della potenza (standby) - (pr. IEC 63103), Corrente di inserzione (pr. IEC 63129)
Nuovo regolamento ecodesign (Draft 2018/10/08):
P st LM = indictore di flicker (per il breve periodo) IEC/TR 61547-1: 2017 SVM = Stroboscopic Visibility Measure IEC/TR 63158: 2018
flicker perception of visual unsteadiness induced by a light stimulus the luminance or spectral distribution of which fluctuates with time, for a static observer in a static environment (CIE TN 006:2016 )
Nuovo regolamento ecodesign (Draft 2018/10/08): Annex I (46) flicker means the perception of visual unsteadiness induced by a light stimulus, the luminance or spectral distribution of which fluctuates with time, for a static observer in a static environment. The fluctuations can be periodic and non-periodic and may be induced by the light source itself, the power source or other influencing factors. The metric for flicker used in this Regulation is the parameter P st LM, where st stands for short term and LM for light flickermeter method, as defined in standards. A value P st LM =1 means that the average observer has a 50 % probability of detecting flicker;
stroboscopic effect change in motion perception induced by a light stimulus the luminance or spectral distribution of which fluctuates with time, for a static observer in a non-static environment (CIE TN 006:2016 )
phantom array effect ghosting change in perceived shape or spatial positions of objects, induced by a light stimulus the luminance or spectral distribution of which fluctuates with time, for a non-static observer in a static environment (CIE TN 006:2016 )
temporal light artefact TLA change in visual perception, induced by a light stimulus the luminance or spectral distribution of which fluctuates with time, for a human observer in a specified environment TLA Flicker Stoboscopic effect Ghosting
Flicker index: FI Percent Flicker (PF) PF =100 x (y max -y min )/(y max +y min )
P st LM = indictore di flicker (per il breve periodo) IEC/TR 61547-1: 2017 SVM = Stroboscopic Visibility Measure IEC/TR 63158: 2018
IEC TR 61547-1 (Full EMC Approach) 1 step
IEC TR 61547-1 (Full EMC Approach) 2 step
ma, Il metodo di prova descritto in questa norma per determinare il valore P st LM può essere utilizzato per valutare il flicker di una sorgente anche in condizioni stabili di tensione
IEC TR 61547-1 (Full EMC Approach)
IEC TR 61547-1 (flicker) struttura del flickermeter: IEC 61000-4-15
Risultati e valutazioni: se P st LM >1 = flicker visibile se P st LM <1 = flicker non visibile
Esempi di risultati:
Esempi di risultati:
P st LM = indictore di flicker (per il breve periodo) IEC/TR 61547-1: 2017 SVM = Stroboscopic Visibility Measure IEC/TR 63158: 2018
Campo di applicazione:
Soglia di visibilità
Soglia di visibilità
Calcolo di SVM
Visibilità se SVM >1: effetto stroboscopico visibile se SVM <1: effetto stroboscopico non visibile
Compatibilità con riprese video e fotografiche (25 10kHz) Compatibilità con scanner e lettori ottici (fino a 100kHz) Compatibilità e valutazione impatto con presenza di animali.
Flicker (IEC/TR 61547-1) ed effetto stroboscopico (IEC/TR 63158) Modalità non attiva dei prodotti e misura della potenza (standby) - (pr. IEC 63103), Corrente di inserzione (pr. IEC 63129)
Nuovo regolamento ecodesign (Draft 2018/10/08): Annex II 1(a) light source Annex II 1(b) separate controlgear
Nuovo regolamento ecodesign (Draft 2018/10/08): DEFINIZIONI: (24) standby power (Psb), expressed in Watt, is the electric power consumption of a light source or of a separate control gear in standby mode; (25) networked standby power (Pnet), expressed in Watt, is the electric power consumption of a connected light source (CLS) or of a connected separate control gear (CSCG) in networked standby mode;
Nuovo regolamento ecodesign (Draft 2018/10/08): DEFINIZIONI: (16) standby mode means the condition of a light source or of a separate control gear, where it is connected to the power supply but the light sources are intentionally not emitting light, and the light source or control gear is awaiting a control signal (from a source different from a network) to return to a state with light emission. Lighting control parts enabling the standby function shall be in their control mode. Non-lighting parts shall be disconnected or switched off or their power consumption shall be minimised following manufacturer s instructions; (17) networked standby mode means the condition of a connected light source (CLS) or a connected separate control gear (CSCG) where it is connected to the power supply but the light source is intentionally not emitting light or the control gear does not supply the electric power that enables light source(s) to emit light, and is awaiting a remotely initiated trigger to return to a state with light emission. Lighting control parts shall be in their control mode. Non-lighting parts shall be disconnected or switched off or their power consumption shall be minimised following manufacturer s instructions;
Metodo misura: Pr. IEC 63103 ED1 Lighting equipment - Non-active mode power measurement (in preparazione)
Standby power Esempio di misura per controlgear Power boundary Esempio di misura per sorgente luminosa con alimentatore incorporato
Network standby power Esempio di misura per controlgear Power boundary Esempio di misura per sorgente luminosa con alimentatore incorporato
Measuring setup (example)
Flicker (IEC/TR 61547-1) ed effetto stroboscopico (IEC/TR 63158) Modalità non attiva dei prodotti e misura della potenza (standby) - (pr. IEC 63103), Corrente di inserzione (pr. IEC 63129)
Fenomeno:
Fenomeno:
Fenomeno: R+L linea EUT 1 R+L linea R+L linea EUT 2 R+L linea EUT 3 R+L linea EUT n
Metodi di misura: Misura in DC Misura in AC
Sequenza di misura: Taratura del circuito per ottenere 400A modificando R adj k Misura della inrush current per 1 DUT (n=1) Misura della inrush current per 2 DUT (n=2) Misura della inrush current per n DUT (n)
Metodo alternativo: Per simulare K alimentatori è possibile modificare L k e R adj k in modo da ottenere I adj k : I adj k = 400 / K E inoltre possibile combinare il numero di alimentatori collegati col settaggio per K DUT ed ottenere il dato per n DUT. Es. circuito per K = 3; DUT collegati m = 2 Il circuito simula n = 3x2 = 6 DUT
Valutazione della misura:
Metodi di misura: Misura in DC Misura in AC
Misura in AC Il metodo di misura in AC deve essere utilizzato solo quando il metodo DC non è utilizzabile ad esempio quando il DUT è provvisto di rilevatore del passaggio per lo 0 (zero crossing detection) o DUT con trasformatore in ingresso.
Calcolo del numero di DUT installabili a valle di un interruttore magnetotermico MCB (allo studio)
SI RINGRAZIA PER L ATTENZIONE per eventuali approfondimenti: Area Tecnica ASSIL tecnico@assil.it