SGDV- E5 (For Linear Servomotors)

Similar documents
(For Linear Servomotors) S G D V - R70 A 21 A th digit. 7th digit. 5th6th digits

4th digit. 7th digit. digits. Specifications. Interface. MECHATROLINK-2 communications Reference Type (for rotary servomotors)

4th digit. 5th+6th digits. 7th digit. Specifications. 8th+9th+10th digits Options (hardware)* 4. Interface

(For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B Voltage Interface 100 VAC 200 VAC 400 VAC V (Three Phase)

SGDV- 01 SGDV- 05. Analog Voltage/Pulse Train Reference Type SERVOPACKs. (For Rotary Servomotors) (For Linear Servomotors)

Analog Voltage/Pulse Train Reference Type SERVOPACKs. (For Rotary Servomotors) (For Linear Servomotors) SGDV - R70 A 01 B

SERIES PRODUCT CATALOG

(For Rotary Servomotors)

AC SERVO DRIVES SERIES. Servopacks. Certified for ISO9001 and ISO14001

Analog Voltage Reference SERVOPACKs Pulse Train Reference SERVOPACKs. (Analog Voltage Reference) SGDV- EP1. (Pulse Train Reference)

Σ-V Series. USER'S MANUAL Design and Maintenance Rotational Motor Command Option Attachable Type. AC Servo Drives

Sigma-5 servo drive System configuration

Σ-V Series. USER'S MANUAL Design and Maintenance. AC Servodrive

LARGE-CAPACITY SERIES

Analog monitor cable. Filter Motion control unit. General purpose cable. (Refer to chapter Sigma-II rotary motors) Cables SGMGH, SGMUH, SGMSH, SGMBH

Σ-V Series. USER'S MANUAL Design and Maintenance Rotational Motor Command Option Attachable Type. AC Servo Drives

SigmaLogic7 Compact Hardware Manual

New Servo Concept: Junma

Σ-V Series. USER'S MANUAL Design and Maintenance. AC Servodrive

Troubleshooting Alarm Displays Warning Displays

USER S MANUAL Design and Maintenance

USER S MANUAL Design and Maintenance

SGDH Amplifier. Part Number Guide. Quick Reference Guide. Amplifier: SGDH - 15 A E- Motor: SGMGH - 09 A C A 6 C $10

DS2 series servo drive

Indexer unit JUSP-NS600. System configuration. Smart and simple positioning solution.

AC SERVO DRIVES JUNMA SERIES D E F I JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA

Troubleshooting Alarm Displays Warning Displays

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

USER'S MANUAL Design and Maintenance

Build the machine you ve dreamed of, today!

SGMMV. Rotary Servomotors SGMMV - A1 A 2 A 2 1. Model Designations. 6th. 5th digit. 1st+2nd digits. 7th digit. 4th digit. 3rd digit.

6th digit. 5th digit. 4th digit. Code Specifications 3 20-bit absolute (standard) D 20-bit incremental (standard) Design Revision Order

Σ-V Series USER'S MANUAL Setup Rotational Motor

Σ-V Series USER'S MANUAL Setup Rotational Motor

USER S MANUAL Design and Maintenance

Troubleshooting Alarm Displays Warning Displays

2Encoder Cable Extension from 30 to 50 m. (Example) SGDV SERVOPACK. Servomotor. Main Circuit Cable SGMJV. Servomotor End CAUTION

EDB series AC servo system

JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA JUNMA AC SERVO DRIVES JUNMA SERIES. Goodwin Electronics: Tel: Web:

BLuAC5 Brushless Universal Servo Amplifier

BLuAC5 Brushless Universal Servo Amplifier

USER S MANUAL For Use with Large-Capacity Models Design and Maintenance

Series SGDH Indexer Application Module USER'S MANUAL

Series SGDH Indexer Application Module USER'S MANUAL

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver.

5th digit. 4th digit. 6th digit. Design Revision Order. Shaft End. Code Specifications

Σ-V Series. USER'S MANUAL Operation of Digital Operator Model: JUSP-OP05A-1-E. AC Servo Drives. Introduction. Parameter/Monitor Modes

SGMJV. Rotary Servomotors SGMJV - 01 A D A 2 1. Model Designations. 2Without Gears. 1st+2nd digits. 3rd digit. 5th digit. 6th digit.

DS2 series 220V servo driver

Σ-V Series. USER'S MANUAL Design and Maintenance. AC Servo Drives. Linear Motor MECHATROLINK-II Communications Reference

G5 Series Servo System

Copyright 2009 YASKAWA ELECTRIC CORPORATION

XtraDrive (XD-) SERIES AC SERVO DRIVER

1S servo drive System configuration

USER S MANUAL Design and Maintenance

1S servo drive System configuration

8V General information. 2 Order data 8V

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

SD Series. AC Spindle Motor Drives with Power Regeneration, AC Servo Drives. Speed Reference with Analog Voltage Expanded Functions

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 JUSP-NS500 NS500 SERVOPACK. 200V Ver.

Integrated servo motor

Installation Servo Drive Dimensions

CL86T. 24~80VDC, 8.2A Peak, Closed-loop, No Tuning. Descriptions. Closed-loop. Stepper. Applications. Datasheet of the Closed-loop Stepper CL86T

AC SERVO DRIVES SERIES. Rotary Servomotors. Certified for ISO9001 and ISO14001

Sigma FSP Amplifier User s Manual

USER S MANUAL. AC Servo Drives -V Series / -V Series for Large-Capacity Models / -7 Series. Safety Module. Model: SGDV-OSA01A.

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Σ-V Series. USER'S MANUAL Operation of Digital Operator. AC Servo Drives. Introduction. Parameter/Monitor Modes. Utility Function Mode

AC Servo Motor Driver. LECYM Series

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

Design Characteristics. FlexDrive II. Series

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

PRODUCT NOTE MOTION PRODUCT ENGINEERING GROUP

AC Servo Drives -V Series/ -V Series for Large-Capacity Models USER S MANUAL. EtherCAT (CoE) Network Module

Series SGMBH/SGDH USER S MANUAL AC Servodrive (400 V, 22 to 55 kw) SGMBH Servomotor SGDH SERVOPACK

Inverter Drive /Vector Drive Motors & Controls

PKG-EML10-EDB10-CBLS System Diagram and Specifications

Sigma-5 Series DE ES FR. -V Series

USER S MANUAL. OMNUC U SERIES MODELS R88M-U (AC Servo Motors) MODELS R88D-UT (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kw)

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

PAM & SAM System User s Manual

Proposing control by a hydraulic servo and V/F inverters

30-80V, 8.2A Peak, No Tuning, Nulls loss of Synchronization

SX (400 V) System configuration

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

AC Servo Motor Driver (MECHATROLINK-II type)

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

Specifications of ASDA A2-E_220V Series

Fan and Pump AC Inverter

Drive Safety integrated AC servo amplifier <MR-J3- S 0.1kW to 55kW> Safety logic unit <MR-J3-D05>

Cat. No. I806-E1-02. Replacement Set for S, R, and H Series

AD Series. AC Servo Drive. For the highest requirements in performance and precision

Sigma II Series Servo System User s Manual

4th digit. 5th digit. 6th digit. Code Specifications. Design Revision Order. Code Specifications. Standard. Code Specifications

SX (690 V) System configuration

Yaskawa Electric Engineering Corporation AC SERVOPACK. EGSV3 Series. User s Manual EGSV3- Document No. ESI-M-005E <1>

AC SERVo DRiVES -V SerieS EN DE ES FR it -V SerieS -V Serie -V SerieS S -V SerieS -V SerieS

SX (400V) System configuration

Transcription:

PACKs with Additional Options SGDV- E (For Rotary Servomotors) SGDV- E5 (For Linear Servomotors) Model Designations SGDV- R70 A E A 000 00 0 v Series SGDV PACK Current Voltage 00 V 400 V Code Applicable Servomotor Max. Capacity kw R70 * 0.05 R90 * 0. R6 * 0. R8 * 0.4 R8 0.5 5R5 * 0.75 7R6.0 0 *.5 80.0 00.0 0 5.0 470 6.0 550 7.5 590 780 5 R9 0.5 R5.0 5R4.5 8R4.0 0.0 70 5.0 0 6.0 60 7.5 80 70 5 Voltage Interface Code A D Code E E5 Design Revision Order A, B 00 VAC 400 VAC Code Options (parameter) Options (software) Options (hardware) 000 Base-mounted (standard) 00 Rack-mounted 00 Varnished 00 Rack-mounted and Varnished 008 Single-phase 00 VAC input (model: SGDV0AEA0080000 ) 00 Dynamic brake (DB) * Command Option Attachable Type (for rotary servomotors) Command Option Attachable Type (for linear servomotors) * These amplifiers can be powered with single or three-phase. * SGDV-0A A008000, a special version of the.5 kw amplifier can be used for single-phase operation. * : The specifications differ in accordance with the power supply voltage of the PACK to be used. - For 00-V and 00-V PACKs : The DB function will be disabled when the PACK stops or the power supply is turned OFF. - For 400-V PACK : The DB resistor can be mounted onto the outside of the PACK. If the DB resistor is not mounted, the DB function will be enabled. 6 YASKAWA

Features Unprecedented ease-of-use through cutting-edge technology New tuning-less function means no adjustment needed. Impressive load regulation with strengthened vibration suppression function. Slashed setup time Setup wizard function and wiring conformation function of engineering tool SigmaWin+ allows easy setup just by watching the monitor. High response characteristics at khz min. New advanced autotuning. uced positioning time through model following control, and smooth machine control enabled by vibration suppression function. Connectivity to INDEXER Option Module for single-axis positioning, EtherCAT (CoE) Network Option Module, CANopen Network Module, Powerlink Network Module and MP600iec Single Axis Controller Option Module. Product Labeling The three digit option module code allows for expandability of the servo amplifier's functionality. Each digit of the code defines a different type of option First Digit (Control Architecture): compatible with various communication interfaces or single-axis control architectures. Second Digit (Safety): compatible with EN6004- stop category and (stop category 0 is standard) Third Digit (Feedback): compatible with fully-closed loop control NOTE: Amplifiers with Interface Option E and E5 can accommodate option modules that utilize all digits of the Option Module Code. Combination Example: Nameplate for PACK Model : SGDV- E A (Refer to Model Designations provided in the PACK pages for details.) Nameplate for INDEXER Option Module EtherCAT (CoE) Network Module CANopen Network Module POWERLINK Network Module Model : SGDV-OCA0A Model : SGDV-OCA0A Model : SGDV-OCB0A Model : SGDV-OCB0A Nameplate for Safety Option Module (SS, SS, SLS and STO) Model : SGDV-OSA0A Nameplate for Option Module for Fully-closed Loop Control Model : SGDV-OFA0A NOTE: Mounting of Option Modules on Amplifiers with Interface Option E and E5 requires mounting kit SGDV-OZA0A (metal bar, mounting screws and cover). 64

-V -V SER -V SERI - Ratings Single-phase 00 V PACK Model SGDV R70A R90A R6A R8A 5R5A 0A * Applicable Servomotor Max. Capacity kw 0.05 0. 0. 0.4 0.75.5 Continuous Output Current A rms 0.66 0.9.6.8 5.5.6 Max. Output Current A rms..9 5.8 9. 6.9 8 Regenerative Resistor None/External Built-in/External Main Circuit (Single Phase) 0 to 0 VAC +0% to -5% 50/60 Hz Control Circuit (Single Phase) 0 to 0 VAC +0% to -5% 50/60 Hz Three-phase 00 V *: Single-phase 00 VAC PACKs are also available (base-mounted PACK model: SGDV-0A A008000, rack-mounted PACK model: SGDV-0A A009000). PACK Model SGDV R70A R90A R6A R8A R8A 5R5A 7R6A 0A 80A 00A 0A 470A 550A 590A 780A Applicable Servomotor Max. Capacity kw 0.05 0. 0. 0.4 0.5 0.75.0.5.0.0 5.0 6 7.5 5 Continuous Output Current A rms 0.66 0.9.6.8.8 5.5 7.6.6 8.5 9.6.9 46.9 54.7 58.6 78 Max. Output Current A rms..9 5.8 9. 6.9 7 8 4 56 84 0 0 40 70 Regenerative Resistor None/External Built-in/External External Main Circuit (Three-phase 00 VAC) Three-phase 00 to 00 VAC +0% to -5% 50/60 Hz Control Circuit (Three-phase 00 VAC) Single-phase 00 to 00 VAC +0% to -5% 50/60 Hz Three-phase 400 V PACK Model SGDV R9D R5D 5R4D 8R4D 0D 70D 0D 60D 80D 70D Applicable Servomotor Max. Capacity kw 0.5.0.5.0.0 5.0 6 7.5 5 Continuous Output Current A rms.9.5 5.4 8.4.9 6.5 0.8 5.4 8. 7. Max. Output Current A rms 5.5 8.5 4 0 8 4 55 65 70 85 Regenerative Resistor Built-in/External External Main Circuit (Three-phase 400 VAC) Three-phase 80 to 480 VAC +0% to -5% 50/60 Hz Control Circuit (4 VDC) 4 VDC ±5% Note: The entire over voltage category is. PACK Overload Characteristics Detecting time (s) 0000 000 00 0 SGMJV 00 00 00 50 Torque reference (percent of rated torque) Detecting time (s) 0000 000 00 SGMAV-0, 04, 06, 08 0 0 0 SGMAV-A5, 0, C 00 00 00 Torque reference (percent of rated torque) Rated torque Approx. Note: Overload characteristics shown above do not guarantee continuous duty of 00% or more output. Use a servomotor with effective torque within the continuous duty zone of Torque-Speed Characteristics. Detecting time (s) 0000 000 00 SGMGV-44A, -55A, -75A SGMGV-0A, -05A, -09A, -A -0A, -0A, -AA, -EA SGMGV- D SGMSV- Rated torque + Max. torque Max. torque Items Control Method Feedback Operating Conditions Rotary Servomotors Linear Servomotors IGBT PWM control, sine-wave driven Serial encoder: -bit (incremental encoder) : 0-bit (incremental/absolute encoder) Absolute linear scale (The signal resolution varies depending on the absolute linear scale.) Incremental linear scale ( The signal resolution varies depending on the incremental linear scale or serial converter unit.) Surrounding/Storage Temperature Surrounding temperature: 0 to +55 C, storage temperature: - 0 to +85 C Ambient/Storage Humidity 90% RH or less (no freezing or condensation) Vibration/Shock Resistance Vibration resistance: 4.9 m/s, Shock resistance: 9.6 m/s Protection class: IP 0, pollution degree: Do not use PACKs in the following locations: Protection class/pollution degree Locations subject to corrosive or flammable gases Locations subject to exposure to water, oil, or chemicals Locations subject to dust, including iron dust, and salts Do not use PACKs in the following locations: Others Locations subject to static electricity noise, strong electromagnetic/magnetic fields, radioactivity Altitude 000 m or less 65 YASKAWA

IES ES V SERIES Items Compliant Standards Configuration Performance UL508C EN5078, EN550/A group class A, EN6000-6-, EN6800-, EN6800-5-, EN954-, IEC6508- to 4 Standard: Base-mounted; Optional: Rack-mounted, Duct-ventilated Speed Control Range :5000 (The lowest speed of the speed control range is the speed at which the servomotor will not stop with a rated torque load.) Load Fluctuation 0% to 00% load: ±0.0% max. (at rated speed) Speed Voltage Fluctuation Rated voltage : ± 0% : 0% (at rated speed) Regulation * Temperature Fluctuation 5±5 C : ±0.% max. (at rated speed) Torque Control Tolerance (Repeatability) ± % Encoder Output Pulses Phase A, phase B, phase C: line driver output The number of dividing pulse: Any setting ratio is available. No. of Channels 7 channels I/O Signals Sequence Input Input Signals which can be allocated Fixed Output Functions Servo alarm (ALM) Forward run prohibited (P-OT), Forward external torque limit (/P-CL), Reverse run prohibited (N-OT) reverse external torque limit (/N-CL) General-purpose input signal (/SI0 to /SI6) * Signal allocations can be performed, and positive and negative logic can be changed. Communications Sequence Output RS-4A Communications USB Communications No. of Channels channels Positioning completion (/COIN) Speed limit detection (/VLT) Output Signals which Speed coincidence detection (/V-CMP) Brake (/BK) can be allocated Servomotor rotation detection (/TGON) Warning (/WRAN) Functions Servo ready (/S-RDY) Near (/NEAR) Torque limit detection (/CLT) Signal allocations can be performed, and positive and negative logic can be changed. Interface Digital operator (JUSP-OP05A--E), personal computer (can be connected with SigmaWin+) :N communications RS-4A port: N= 5 max. available Axis address setting Set by parameters Interface Personal computers (can be connected with SigmaWin+) Communications Standard Compliant with USB. standard ( Mbps) Display Analog Monitor Dynamic Brake (DB) Regenerative Processing Overtravel (OT) Prevention Protective Functions Utility Functions Safety Functions Option Modules Input Output CHARGE and POWER (seven-segment display) Number of points: Output voltage: ±0 VDC (linearity effective range ±8 V) Resolution: 6 bit Accuracy: ±0 mv (Typ) Max. output current: ±0 ma Settling time (±%):. ms (Typ) Activated when the power supply for the main circuit or the PACK is OFF, when overtravel (OT) or a servo alarm occurs, or during a hardwired base block. 00 VAC SGDV-R70A, -R90A, -R6A, -R8A: External regenerative resistor (optional) 00 VAC SGDV-470A, -550A, -590A, -780A: External regenerative resistor unit (optional) 00 VAC models other than shown above: Built-in regenerative resistor 400 VAC SGDV-0D, -60D, -80D, -70D: External regenerative resistor unit (optional) 400 VAC models other than shown above: Built-in regenerative resistor Dynamic brake stop at P-OT or N-OT, deceleration to a stop, or free run to a stop Overcurrent, Overvoltage, low voltage, overload, regeneration error Gain adjustment, alarm history, JOG operation, origin search, etc. /HWBB, /HWBB: Baseblock signal for power module EDM: Status monitor (fixed output) of built-in safety circuit Fully-closed option module, EtherCAT (CoE), INDEXER module, CANopen Network Module, Powerlink Option Module, MP600iec.5 axis controller *: Speed regulation is defined as follows: Speed regulation= No-load motor speed-total load motor speed 00% Rated motor speed The motor speed may change due to voltage variations or temperature variation. The ratio of speed changes to the rated speed represent speed regulation due to voltage and temperature fluctuations. *: For details on the functions of the general-purpose input signals /SI0 to /SI6, refer to the manual of the Command Option Module being used. 66

-V -V SER -V SERI - Power Supply Capacities and Power Losses The following table shows PACK's power supply capacities and power losses at the rated output. Main Circuit Power Supply Applicable Servomotor Max. Capacity kw PACK Model SGDV Power Supply Capacity kva Output Current A Main Circuit Power Loss W Regenerative Resistor Power Loss W Control Circuit Power Loss W Total Power Loss W Single-phase 00 V Three-phase 00 V Three-phase 400 V 0.05 R70A 0. 0.66 5.. 0. R90A 0. 0.9 7.4 4.4 0. R6A 0.7.6.7 7 0.7 0.4 R8A..8 4.9 4.9 0.75 5R5A.9 5.5 5.7 8 77.7.5 0A 4.6 68. 0 00. 0.05 R70A 0. 0.66 5.. 0. R90A 0. 0.9 7. 4. 0. R6A 0.6.6.5 0.5 0.4 R8A.8 4.0 7 4.0 0.5 R8A.4.8 0. 45. 0.75 5R5A.6 5.5 4.8 8 68.8.0 7R6A. 7.6 5.6 78.6.5 0A..6 65.8 0 97.8.0 80A 4 8.5.9 49.9 6.0 00A 5.9 9.6.8 6.4 5.0 0A 7.5.9 6.7 6 7 6.7 6.0 470A 0.7 46.9 79.4 (80) *.4 7.5 550A 4.6 54.7 57.8 90.8 590A.7 58.6 4.7 (50) * 479.7 48 5 780A 9.6 78 599.0 647.0 0.5 R9D..9 4.6 59.6.0 R5D..5 46. 4 8..5 5R4D.5 5.4 7. 06..0 8R4D 4.5 8.4 77.9 0.9 8 5.0 0D 7..9 08.7 6.7 5.0 70D.7 6.5 6. 6 4. 6.0 0D.4 0.8 7.7 99.7 (80) * 7 7.5 60D 4.4 5.7 8.6 45.6 80D.9 8. 94.6 4.6 (50) *4 0 5 70D 0.6 7. 40.8 4.8 *: For the optional JUSP-RA04-E regenerative resistor unit. *: For the optional JUSP-RA05-E regenerative resistor unit. *: For the optional JUSP-RA8-E regenerative resistor unit. *4: For the optional JUSP-RA9-E regenerative resistor unit. Notes: SGDVR70A, R90A, R6A, and R8A PACKs do not have built-in regenerative resistors. If the regenerative energy exceeds the specified value, connect an external regenerative resistor (optional). SGDV470A, 550A, 590A, 780A, 0D, 60D, 80D, 70D PACKs do not have built-in regenerative resistors. Be sure to connect a regenerative resistor unit (optional) or an external regenerative resistor (optional). For selection details, refer to page 64. Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded. Remove the lead or short bar that is short-circuiting the PACK main circuit terminal B and B. (SGDVR8A, 5R5A, 7R6A, 0A, 80A, 00A, 0A, or 400 V class PACKs.) Install an external regenerative resistor (optional). For selection details, refer to page 64. 67 YASKAWA

JZSP-CVS06-0-E REF YASKAWA DIGITAL OPERATOR REF ALARM SVON READ YASKAWA WRITE DIGITAL OPERATOR IES ES V SERIES Selecting Cables Cables for CN CN CN5 CN7 CN8 CN for Option Module Type PACKs CN5 Cable for Analog Monitor CN Digital Operator Converter Cable Digital Operator CN7 CN Connection Cable for Personal Computer Cable for I/O Signals ALARM SVON READ WRITE LED Indicator for External Device CN8 Safety Cable Connection Cable Between Fully Closed Loop Option Module and Serial Converter Unit (see page 6). Name Length Order No. Details Soldered Connector Kit JZSP-CSI9--E () CN Cables for I/O Signals Connector Terminal Converter Unit Cable with Loose wire at One End JUSP-TA6P-E () m JZSP-CSI0--E m JZSP-CSI0--E m JZSP-CSI0--E Terminal Block and 0.5 m Connection Cable () With Connection Cable ( m) Digital Operator JUSP-OP05A--E (4) CN CN7 Connection Cables for Personal Computer CN5 Cables for Analog Monitor CN8 Cables for Safety Functions JZSP-CVS05-A-E Cable with Connectors at Both Ends Digital Operator Converter Cable * 0. m JZSP-CVS05-A-E (5) Cables with Connector * Connector kit * Cable with Connectors at Both Ends.5 m JZSP-CVS06-0-E (6) m JZSP-CA0-E PACK End (7) m JZSP-CVH0-0-E JZSP-CVH0-0-E-G Contact Tyco Electronics AMP K.K. Product name : Industrial Mini I/O D-shape Type Plug Connector Kit Model : 0595- * : A converter cable is required to use series digital operators (model: JUSP-OP05A) for series PACKs. * : When using the safety function, connect this cable to the safety devices. Even when not using the safety function, use PACKs with the Safe Jumper Connector (model: JZSP-CVH05-E) connected. * : Use the connector kit when you make cables yourself. 04 (8) 68

-V -V SER -V SERI - Selecting Cables () Connector Kit for CN Use the following connector and cable to assemble the cable. The CN connector kit includes one case and one connector. Connector Kit Model JZSP-CSI9--E 06-5A0-008* set Case Connector Model Qty Model Qty 06-000PE* (Soldered) External Dimensions of Case (Units: mm).0 5.8 4.0. 0.0 * : Manufactured by Sumitomo M Ltd. Cable Size Item Cable Use twisted-pair or twisted-pair shielded wire. Applicable Wires AWG4, 6, 8, 0 Cable Finished Diameter 6 dia. max. 9.0.8 5. 7..7 External Dimensions of Connector (Units: mm).54.7 Pin No.5 Pin No.4 Pin No.5 Pin No.6 5.. Pin No. Pin No. Pin No. Pin No. 5.8 Pin No. 9. 7.5.7.9 6.8 9.5 Pin No.4.7 5.4.5 5 () Connector Terminal Converter Unit for CN Configurations PACK External Dimensions of Terminal Block (Units: mm) Terminal Block (40P) M.5 Screw Connector Plug (40P) FCN-64P040-AU +50 CN Cable Length: 500-0 mm B A Model: JUSP- TA6 P B0 A0 9 40 9.5 7 7 B B0 A A0 9 40 Can be fixed on DIN rail 0.5 5.5.5 0.5.5 4 45 External Dimensions of Cable (Units: mm) PACK End Connector (6P) 06-6000EL(Sumitomo M Ltd.) Shell 06-5A0-008(Sumitomo M Ltd.) Cable () AWG#8, 8P SSRFPVV-SB Terminal Converter Unit-end Connector (40P) FCN-6J040-AU(Fujitsu Ltd.) Cover FCN-60C040-B(Fujitsu Ltd.) Model Cable Length (L) Approx. Mass JUSP-TA6P-E 0.5 m 00 g JUSP-TA6P--E m 00 g JUSP-TA6P--E m 400 g 7. 7 9 L 47 Note: The pin number in the PACK connector and the pin number in the terminal block are the same. Pin numbers to 6 are used in the terminal block. Do not use a pin number of 7 or higher. If assembling cables, refer to Cable with Loose Wires at One End for CN Connection Diagram of JZSP-CSI0- -E Cable on the next page. 69 YASKAWA

IES ES V SERIES Selecting Cables Selecting Cables 7. () Cable with Loose Wires at One End for CN External Dimensions of Cable (Units: mm) PACK End Connector 06-6000EL (by Sumitomo M Ltd.) Shell 06-5A0-008 Model JZSP-CSI0--E JZSP-CSI0--E JZSP-CSI0--E (4) Digital Operator (Model: JUSP-OP05A--E) 70 Cable (Ivory) SSRFPVV-SB AWG#8 P UL076 VW-SC 4 L 00 +0-0 (6. Dia.) Cable Length m m m Dia. Wire Markers -M Screws, Depth 5 (For mounting digital operator) Cable with Loose Wires at One End for CN Connection Diagram of JZSP-CSI0- -E Cable PACK End Pin No. Signal Wire Marking Color Color Dots 4 5 6 7 8 9 0 4 5 6 7 8 9 0 4 5 6 /BK+ /BK ALM+ ALM +4VIN P-OT N-OT /DEC /EXT /EXT /EXT /SI0 BAT (+) BAT ( ) SG PAO /PAO PBO /PBO PCO /PCO /SO+ /SO /SO+ /SO Orange Orange Gray Gray Orange Orange Gray Gray Host Controller End Lead Marker 4 5 6 7 8 9 0 4 5 6 7 8 9 0 4 5 6 : Represents twisted-pair wires. (5) Digital Operator Converter Cable for CN (Model: JZSP-CVS05-A-E) A converter cable is required to use series digital operators (model: JUSP-OP05A) for series PACKs. REF External Dimensions (Units: mm) ALARM SVON READ YASKAWA WRITE DIGITAL OPERATOR 0 +0 000 0 7.8 Connector: HDR-E4MAG+(Honda Tsushin Kogyo Co., Ltd.) Case: HDR-E4LPA5(Honda Tsushin Kogyo Co., Ltd.) Nameplate 57 (.7) (9.5) (9) Connector (4-pole): 04-60PL (Sumitomo M Ltd.) Cover: FA45806 (Yasco Components Co., Ltd.) 04 00 +0 0 (5) (4. Dia) JZSP-CVS05-A-E Connector (4-pole): HDR-E4MAG+ (Honda Tsushin Kogyo Co., Ltd.) Cover HDR-E4LPA5 (Honda Tsushin Kogyo Co., Ltd.) (8) () 70

-V -V SER -V SERI - Selecting Cables (6) Connection Cable for Personal Computer for CN7 (Model: JZSP-CVS06-0-E) External Dimensions (Units: mm),500 +00 0 0 to 0 JZSP-CVS06-0-E (00) (55) IMPORTANT Use a cable specified by Yaskawa. When using other cables, operation cannot be guaranteed. (7) Cable for Analog Monitor for CN5 (Model: JZSP-CA0-E) External Dimensions (Units: mm) Socket DF-4DS-C* Contact DF-48SCF* +0 000-0 * : Manufactured by Hirose Electric Corporation. 4 White View from Cable End Pin No. Cable Color Signal Standard Settings Analog Monitor Motor speed : V/000 min - White Analog Monitor Torque reference : V/00% rated torque, 4 ( cables) GND(0V) Note : The specifications above are factory settings. Monitor specifications can be changed by changing parameters Pn006 and Pn007. (8) Cable with Connector for CN8 (Model: JZSP-CVH0-0-E) External Dimensions (Units: mm) 000 +50 () Pin No. Signal Lead Color Marking Color (0) Connector Kit: 0595- (Tyco Electronics AMP K.K.) (Model: JZSP-CVH0-0-E-G) External Dimensions (Units: mm) (8) () Not used Not used /HWBB White 4 /HWBB+ White 5 /HWBB Gray 6 /HWBB+ Gray 7 EDM Orange 8 EDM+ Orange 000 +50 () Pin No. Signal Lead Color Marking Color (0) Connector Kit: 0595- (Tyco Electronics AMP K.K.) (8) () Not used Not used /HWBB White 4 /HWBB+ Brown 5 /HWBB 6 /HWBB+ Yellow 7 EDM Grey 8 EDM+ 7 YASKAWA

IES ES V SERIES 7