IB IL AO 1/U/SF. Function. INTERBUS Inline Terminal With One Analog Voltage Output. Data Sheet 5736CC01

Similar documents
IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

PHOENIX CONTACT - 01/2007

VARIO RTD 2. Function. I/O Extension Module With Two Analog Input Channels for the Connection of Temperature Shunts (RTD) User Manual

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

IB IL AI 8/IS IB IL AI 8/IS-PAC

IB IL 24/230 DOR 4/W-PC IB IL 24/230 DOR 4/W-PC-PAC

IB ST (ZF) 24 PT 100 4/4

VersaPoint I/O Module

PHOENIX CONTACT - 03/2007

This data sheet is only valid in association with the IL SYS INST UM E user manual.

IB IL TEMP 2 RTD (-PAC)

VersaPoint I/O Module

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

OUTPUT 5/24 VDC PWM/PT 2 CHANNEL. 1 Description. GFK-2761 May 2012

onlinecomponents.com

IB IL 400 ELR 1-3A. Product Description. INTERBUS Inline Power-Level Terminal as a Direct Starter for a Motor With a Power of up to 1.

IB IL TEMP 4/8 RTD-EF-XC-PAC

IB IL TEMP 4/8 RTD/EF...

This data sheet is only valid in association with the UM EN AXL SYS INST user manual.

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

MACX MCR-UI-UI-UP(-SP)(-NC)

MINI-PS AC/2X15DC/1

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

QUINT-PS-24DC/24DC/10

DIGEM f 96 x 48 EK. Applications. Description

QUINT-PS AC/24DC/40

MINI-PS AC/24DC/1.3

MINI MCR-SL-UI-f(-SP)

POINTAX 6000L2 Point Recorder

The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement.

TIP551. Optically Isolated 4 Channel 16 Bit D/A. Version 1.1. User Manual. Issue December 2009

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/40

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Type CP-S, CP-C & CP-A Switch mode

ISOMETER IRDH575. Approvals

PLC INTERFACE With Leakage Current and Interference Voltage Suppression

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

on-board EEPROM, are incorporated for automatic zero point and full-scale alignment.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

MCR-C-UI-UI-DCI MCR 3-Way Isolation Amplifier, Configurable

ROTRONIC HygroClip Digital Input / Output

QUINT-PS/ 1AC/24DC/20

DA DA 26 Technical Specification. Page 1/27. Volz Servos GmbH & Co. KG servos.com

XIOC technology and networking modules

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

20 General technical data XI/ON

Overcurrent Protection / 7SJ45

7.2 DV1311.L08 and DV1311.L12

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Power supply CP-D 24/1.3

Dual 16-Bit DIGITAL-TO-ANALOG CONVERTER

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

VariTrans P V. Safe and Sound.

INFO-PTr. PT-100 Measuring Card. PT-100 Temperature Measurement. Technical Data

D3 04AD 4-Channel Analog Input

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

This Errata Sheet contains corrections or changes made after the publication of this manual.

Medium Converter FL MC 10BASE-T/FO G850

Signal conditioner - MACX MCR-UI-UI-NC

SIMPLY PRECISE PRELIMINARY. Preliminary product overview - LAK encoder. LAK 1 Absolute linear encoder with signal control

This Datasheet is for the IC693ALG220. Analog Voltage Input - 4 Channel.

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

IP-OPTODA16CH4. 4 Channels of Optically Isolated 16-Bit D/A Conversion. User Manual. SBS Technologies, Inc. Subject to change without notice.

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Power supply CP-D 12/2.1

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

X20(c)AI General information. 2 Coated modules. 3 Order data. X20(c)AI4622

Pulse Scaler for DIN Rail Attachment

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Analog amplifier RA. RE Edition: Replaces:

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

Power supply CP-D 24/4.2 Primary switch mode power supply

16-Bit ANALOG-TO-DIGITAL CONVERTER

VariTrans P D1 TRMS

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

TIP500. Optically Isolated 16 Channel 12 Bit ADC. Version 1.1. User Manual. Issue January 2010

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

LINAX 4000L Continuous-line recorder

LED Driver Compact dimming

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

Electronic timer CT-TGD.22

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Transcription:

INTERBUS Inline Terminal With One Analog Voltage Output Data Sheet 5736CC01 05/2001 # %! $ ) This data sheet is intended to be used in conjunction with the Configuring and Installing the INTERBUS Inline Product Range user manual IB IL SYS PRO UM E. Function This terminal is used to output analog voltage signals. The signals are available with 16 bit resolution. Features One analog signal output to connect voltage outputs Actuator connection (using 2-wire technology and shield connection) Voltage range: 0 V to 10 V Process data update including conversion time of the digital/analog converter < 1 ms Figure 1 # %! $ ) % terminal with the connector plugged in Please note that the connector is not supplied with the terminal. Refer to the Ordering Data Table at the end of this data sheet to choose the appropriate connector for your application. 5736CC01 1

Local Diagnostic and Status Indicators, Des. Color Meaning D Green Bus diagnostics ) Terminal Assignment Terminal Point Signal Assignment 1.1 U Voltage output 0 V to 10 V 2.1 Not used 1.2, 2.2 Not used 1.3, 2.3 GND Ground 1.4, 2.4 Shield Shield connection!!!! " " " " # %! $ ) Figure 2 terminal with the appropriate connector Installation Instruction High current flowing through the voltage jumpers U M and U S leads to a temperature rise of the voltage jumpers and the inside of the terminal. Note the following instruction to keep the current flowing through the voltage jumpers of the analog terminals as low as possible: All of the analog terminals need a separate main circuit! If this is not possible in your application and if you are using analog terminals in a main circuit together with other terminals, make sure you are placing the analog terminals behind all the other terminals at the end of the main circuit. Please note the derating curve on page 12. 2 5736CC01

Internal Circuit Diagram Key: OPC INTERBUS protocol chip 1 6-4 * 7 5 7 7 ) ) 7 2 + N N N : : : Optocoupler DC/DC converter with electrical isolation " 8 % # 8 # 8 4 -. Reference voltage Amplifier 4 -. Digital/analog converter Analog output " 8 7 5 Analog ground, electrically isolated from ground of the voltage jumper " 8 7 Other symbols are explained in the IB IL SYS PRO UM E user manual. # %! $ )! Figure 3 Internal wiring of the terminal points 5736CC01 3

Electrical Isolation 1 6-4 * 7 5? = > K I 1 7 % # 8, + * K I E JA H B=? A 2 + 1 6-4 * 7 5? = > K I 7 6 7 % # 8, + 7 ) ) " 8, + 7 ) ) " 8, + " 8 % # 8 # 8 % # 8 # 8 1 E JA H B=? A ) * - A? JHE? = EI = JE > A JM A A = HA = ) = @ = HA = * Figure 4 ) = C K JF K J # %! $ ) &. - F JA JE= Electrical isolation of the function areas Connection Always connect the analog actuator using shielded, twisted-pair cables. Connect one end of the shielding to protective earth ground (PE). At the module, fold the outer cable sheath back and connect the shield to the terminal via the shield connector clamp. The clamp connects the shield directly to FE (functional earth ground) on the module side. When using cables longer than 10 m (32.8 ft.) in environments with heavy noise, we recommend connecting the shield through an RC element to the FE potential of the actuator. Typically, the capacitor C should be rated between 1 and 15 nf. The resistor R should be at least 10 MW. 4 5736CC01

Connection Example Use a connector with shield connection when installing the actuator. Figure 5 shows the connection schematically (without shield connector)., )!! " " # %! $ ) " 7 6 Figure 5 Typical actuator connection (using 2-wire technology and shield connection) 5736CC01 5

Programming Data ID code 7D hex (125 dec ) Length code 01 hex Input address area 0 bytes Output address area 2 bytes Parameter channel 0 bytes (PCP) Register length (bus) 2 bytes INTERBUS Process Data Words The process data input word is not used. Assignment of the Terminal Points to the Process Data Output Word INTERBUS reference Byte-bit view Terminal points Word Word x Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Byte Byte 0 Byte 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Signal Terminal point 1.1: Voltage output Signal reference Terminal point 1.3 Shield (FE) Terminal point 1.4 6 5736CC01

INTERBUS OUT Process Data Output Words The process data output word specifies the output value in each cycle. 2 H? A I I @ = J= M H@ 5 * 5 * # "! ' & % $ # "! ) 8 # # $ $ Figure 6 Process data output word AV MSB LSB Analog value Most Significant Bit Least Significant Bit All output values are displayed with 16 bit resolution. 5736CC01 7

Significant Values in the Process Data Word INTERBUS OUT Process Data Word for the Voltage Output 0 V to 10 V (Example) Voltage output Analog value Process data word 0 V to 10 V (V) Hex. Binary (two s complement) MSB LSB 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 10 V minus 1 QS 9.99985 FFFF 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10 V minus 2 QS 9.99969 FFFE 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 Half FVOR 5.0000 8000 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 QS 0.153 mv 0001 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Zero 0.0000 0000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Abbreviations used: QS Quantization Step(s) MSB Most Significant Bit FVOR Final Value of the Output Range LSB Least Significant Bit 8 5736CC01

Output Behavior of the Voltage Output Take output behavior (in the event of an error) into account when planning your system! Switching Operation/ State of the Supply Voltage Marginal Conditions INTERBUS OUT Process Data Word (hexadecimal) Behavior/Status of the Analog Output U ANA from 0 V to 24 V U L = 0 V xxxx 0 V U ANA from 24 V to 0 V U L = 7.5 V xxxx 0 V Bus in stop state U ANA = 0 V xxxx 0 V Bus in stop state U ANA = 24 V xxxx 0 V or keep last value U ANA U L Analog supply voltage of the terminal Supply voltage of the module electronics (logic supply) xxxx Any value ranging from 0000 hex to FFFF hex. 5736CC01 9

Response of the Control System or Computer to a Hardware Signal for Different Control or Computer Systems Signal Control or Computer System Status After the Switching Operation INTERBUS OUT Analog Output Process Data Word U out NORM* Schneider Automation 0000 0 V BASP Siemens S5 0000 0 V CLAB Bosch 0000 0 V SYSFAIL VME 0000 0 V SYSFAIL PC 0000 0 V CLEAR OUT Moeller IPC 0000 0 V * On controller boards for Schneider Automation control systems it is possible to set the NORM signal in such a way that the INTERBUS OUT process data word and the analog output keep the last value. Response of the Voltage Output to a Control Command of the INTERBUS Controller Board Command Status After the Switching Operation INTERBUS OUT Process Data Word Analog Output U out STOP Keep last value Keep last value ALARM STOP (reset) Keep last value Keep last value 10 5736CC01

Technical Data General Housing dimensions (width x height x depth) Weight Operating mode Connection type of the actuators Permissible temperature (operation) Permissible temperature (storage/transport) Permissible humidity (operation) 12.2 mm x 120 mm x 71.5 mm (0.480 in. x 4.724 in. x 2.795 in.) 46 g (without connector) Process data operation with 1 word 2-wire technology -25 C to +55 C (-13 F to +131 F) -25 C to +85 C (-13 F to +185 F) 75% on average, 85% occasionally Ranging from -25 C to +55 C (-13 F to +131 F). Appropriate measures against increased humidity (> 85%) must be taken. Permissible humidity (storage/transport) 75% on average, 85% occasionally For a short period, slight condensation may appear on the housing if, for example, the terminal is brought into a closed room from a vehicle. Permissible air pressure (operation) 80 kpa to 106 kpa (up to 2000 m [6562 ft.] above sea level) Permissible air pressure (storage/transport) 70 kpa to 106 kpa (up to 3000 m [9843 ft.] above sea level) Degree of protection IP 20 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Deviations From Common Technical Data That Is Indicated in the IB IL SYS PRO UM E User Manual Mechanical Demands Shock test according to IEC 60068-2-27 15g load for 11 ms, half sinusoidal wave, three shocks in each space direction and orientation. 25g load for 6 ms, half sinusoidal wave, three shocks in each space direction and orientation. Interface INTERBUS interface Data routing 5736CC01 11

Power Consumption Communications Power U L Current consumption from UL (local bus) I/O supply voltage U ANA Current consumption of U ANA Total power consumption 7.5 V Approx. 30 ma, typical; 40 ma, maximum 24 V DC 15 ma, typical; 20 ma, maximum Approx. 585 mw, typical Supply of the Module Electronics and I/O Through Bus Terminal/Power Terminal Connection method Potential routing Derating: Permissible ambient temperature depending on the current of the voltage jumpers U M and U S (total current) 6 7 + $ # # # " # "! #! # # # " $ & 1 ) # %! $ ) ' T U [ C] I [A] Ambient temperature ( C) Current flowing through the voltage jumpers U M and U S (A) 12 5736CC01

Analog Output Number 1 Signals/resolution in the process data word (quantization) Voltage 0 to 10 V 0 to 9.99985 V 0.153 mv/lsb Measuring value representation 16 bits straight binary Basic error limit ±0.05%, typical Output load 2 kω, minimum Process data update including the conversion time of the digital/analog converter Slew rate (> 99% of the final value) < 10 µs 1 INTERBUS cycle (depending on the bus configuration); < 1 ms Tolerance and Temperature Response of the Voltage Output (The error indications refer to the output range final value of 10 V.) Typical Maximum Error at 23 C (73.4 F) Total offset voltage ±0.03% ±0.05% Gain error ±0.10% ±0.15% Differential non-linearity ±0.0012% ±0.003% Total error at 23 C (73.4 F) ±0.15% ±0.25% Temperature response at -25 C to 55 C (-13 F to 131 F) Offset voltage drift T KVO ±10 ppm/k ±65 ppm/k Gain drift T KG ±30 ppm/k ±35 ppm/k Total voltage drift T Ktot = T KVO + T KG ±40 ppm/k ±100 ppm/k Total error of the voltage output (-25 C to 55 C [-13 F to 131 F]) Offset error + gain error + linearity error + drift error ±0.30% ±0.60% 5736CC01 13

Additional tolerances influenced by electromagnetic fields Type of electromagnetic interference Criterion Typical, relative deviation of the measuring range final value Electromagnetic fields Field strength 10 V/m acc. to IEC 61000-4-3 A < 1% Fast transients Supply 2 kv, output 1 kv acc. to IEC 61000-4-4 Conducted interference Class 3 (test voltage 10 V) acc. to IEC 61000-4-6 Safety Devices None B < 1% A < 6% Electrical Isolation The DC/DC converter ensures electrical isolation between the logic level and the I/O area. Common potentials 24 V I/O voltage, 24 V segment voltage, and GND have the same potential. FE (functional earth ground) is a separate potential area. Separate system potentials consisting of bus terminal/power terminal and I/O terminal - Test distance - Test voltage 7.5 V supply (bus logic) / 24 V supply U ANA / I/O 500 V AC, 50 Hz, 1 min. 7.5 V supply (bus logic) / 24 V supply U ANA / functional earth ground 500 V AC, 50 Hz, 1 min. 24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min. Error Messages to the Higher-Level Control or Computer System Breakdown or dropping of communications Yes, I/O error message to the bus terminal power U L 14 5736CC01

Ordering Data Description Order Designation Order No. Terminal with one analog voltage output 27 27 77 6 You need 1 connector (total) for the AO 1/U/SF terminal. I/O connector with six terminals using springcage method and shield connection (green, w/o color print), pack of 5 Configuring and Installing the INTERBUS Inline Product Range user manual IB IL SCN-6 SHIELD 27 26 35 3 IB IL SYS PRO UM E 27 43 04 8 5736CC01 15

Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany + 49 - (0) 52 35-3-00 + 49 - (0) 52 35-3-4 12 00 www.phoenixcontact.com Phoenix Contact 05/2001 Technical modifications reserved TNR 94 24 47 0 16 5736CC01