Vert-X 27E - 24V / SPI. Applications Harvesting machine Fork lift Hydraulic pump

Similar documents
Vert-X 27E - 24V / 4-20mA. Applications Harvesting machine Fork lift Hydraulic pump

Vert-X 27E - 5V / % Ub. Applications Harvesting machine Fork lift Hydraulic pump

Vert-X 22E - 5V / PWM. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Vert-X 22E - 24V / 4-20mA. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Vert-X 37E - 5V / % Ub. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles

Vert-X 22E - 5V / % Ub. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Vert-X 31E - 24V / SPI. Applications Concrete pump Access control system Fork lift

Vert-X 31E - 5V / % Ub. Applications Concrete pump Access control system Fork lift

Vert-X 28HD - 24V / V. Applications Harvester Public transport Construction machines

Vert-X 31E 24V. Applications Concrete pump Access control system Fork lift

Vert-X 37-5V. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles

Vert-X 16. Applications Servodrives Dancer arm Operating table

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

high grade, temperature resistant plastic, Thermoplast with brass inserts

high grade, temperature resistant plastic, Thermoplast with brass inserts

Rotational Position Sensor, Kit Type, Hall Effect Technology

NPN PNP NPN PNP NPN PNP

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

Wimesure 54, rue de Versailles CHEVREUSE Tél Fax

Type CP-S, CP-C & CP-A Switch mode

Connection to the sensor is with simple flying leads for customer termination. 1 Page NRH300DP Rev B 09/15

Data Sheet for Angle Sensors

38 Series - Relay interface modules A

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

38 Series - Relay interface modules A

Multiturn Sensor non-contacting. Series RSM2800 analogue. Preliminary data sheet

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Single Turn Servo Mount Hall Effect Sensor in Size 05 (12.7 mm)

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

SAMSUNG ELECTRO-MECHANICS CO., LTD

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Technical data. General specifications. Measurement range min max. 360

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Multi-voltage Multi-function. Wiring diagram (without control signal)

DTM.OCS.S/N - Modbus Level Transmitter

2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals

Throttle Position Sensor in Hall Effect Technology Hollow and D-Shaft Versions

C B. Models. Models 2MOPP

M5800 Pressure Transducer with Rotatable Display

CP-T range Product group picture

Electronic timer CT-TGD.22

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

Throttle Position Sensor in Hall Effect Technology Hollow and D-Shaft Versions

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

38 Series - Relay interface modules A. Features /

Zelio Control Measurement Relays

08/07/2015

Power supply CP-E 24/0.75

Ten Turns Servo or Bushing Mount Hall Effect Sensor in Size 09 (22.2 mm)

CP-T range Benefits and advantages

Switching Power Supply Type SPP1 60W Enclosed type

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Power supply CP-E 24/2.5

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

83 Series - Modular timers 16 A. Features

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

MI2000ERW. Series. Miniature 1 x 1 20W, Ultra-Wide 2:1 Input DC/DC Con vert ers. Key Features:

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

CP-E range Benefits and advantages

Power supply CP-D 24/1.3

48 Series - Relay interface modules A. Features

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Power supply CP-E 24/2.5

SAMSUNG ELECTRO-MECHANICS CO., LTD

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

Pressure transmitter AKS 32 and AKS 33

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

Power supply CP-E 24/20.0

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

08/07/2015

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Rotary Measurement Technology Absolute Encoders, Multiturn

Packaging. nom. Output Voltage

Incremental Encoder Model: FOI58

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Solid-state Timer H3DS

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Online data sheet ACM36-L1K0-K01 ACS/ACM36 ABSOLUTE ENCODERS

83 SERIES. 83 Series - Modular timers A. Features

Transcription:

Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearitiy (without misalignment) % of meas. range ±0.3 - Indep. linearitiy (with allowed misalignment @ 360 ) % of meas. range ±0.5 - Max. hysteresis 0.1 - Resolution bit 14 - Max. repeatability 0.1 - Sample rate fast mode khz 2.2 - Sample rate slow mode khz (0.55) - System propagation delay fast mode µs 400 - System propagation delay slow mode µs (600) - Max. temperature coefficient of the output signal ppm/ K 25 - MTTFd / MTBF years 240 / 240 - Power supply voltage VDC 8... 35 - Current consumption without load (typ.) fast mode ma 19 - Current consumption without load (typ.) slow mode ma (14) - Min. ohmic load at output kohm - - Max. capacitive load at output nf - - Reverse polarity protection of power supply yes - Electrical connection axial Wires (5x) - Cross section of single wires mm 2 0.56 (AWG20) - Electrical connection radial Cable 6pole - Cross section of single wires mm 2 0.25 (AWG24) - Redundancy feasible yes - Electrical connection redundant axial Wires (10x) - Cross section of single wires redundant mm 2 0.25 (AWG24) - Electrical connection redundant radial Cable 10pole - Cross section of single wires redundant mm 2 0.09 (AWG28) - Vert-X 27E - 24V / SPI Applications Harvesting machine Fork lift Hydraulic pump Features High protection class IP68 Compact dimensions Non-contacting measuring method Very long life High accuracy of measurement Applications under adverse ambient conditions possible (humidity, dampness, dust, vibrations etc.) Full resolution and accuracy at programmed electrical angle Mechanical data Mechanical range 360 (continuous) - Protection class IP68 - Min. life movements no limitation - Operating & storage temperature C -40... +85 - IEC 68-2-6 Vibration (Amax = 0.75mm, f = 5 2000 Hz) g 50 - IEC 68-2-27 Shock g 200 - Standards EN 55022 class B, Emission radiated (30... 230 MHz) db(µv/m) max. 30 - EN 55022 class B, Emission radiated (230...1000MHz) db(µv/m) max. 37 - EN 61000-4-2, ESD (contact discharge / air discharge) kv ±4 / ±8 - EN 61000-4-3, Immission HF radiated (80... 1000 MHz) V/m 30 - EN 61000-4-4, Burst (on all lines) kv ±1 - EN 61000-4-5, Surge (lines to ground) kv ±1 - EN 61000-4-6, Immission HF conducted (0.15...80MHz) Vemk 10 - EN 61000-4-8, Immission magnetic field (50Hz) A/m 30 - IEC 60393-1 Insulation resistance (500VDC, 1bar, 2s) GOhm 20 - IEC 60393-1 Dielectric strength (VAC, 50Hz, 1min, 1bar) kv 1 -

Vert-X 27E - 24V / SPI Ordering code Electrical connection / axial 2 Optional Wires 10pole 7 Standard Wires 5pole / 6pole 9 Optional Special cable ; special wires Output characteristics Positive gradient CW Standard 1 Positive gradient CCW Optional 2 Redundant, positive gradient CW Optional 3 Redundant, positive gradient CCW Optional 4 Redundant, crossed signal curves Optional 5 Output signal SPI Standard 8 Power supply voltage 24VDC Standard 1 Electrical connection / radial 1 Optional Round cable 10pole 6 Standard Round cable 6pole 9 Optional Special cable ; special wires Length of wires 01 Optional 10cm 03 Optional 30cm 05 Standard 50cm 99 Optional Special length Length of cable 02 Standard 1.0m 06 Optional 3.0m 10 Optional 5.0m 99 Optional Special length Vert-X 2 7 E 2 7 3 6 1 8 1 7 0 5 Electrical angle 36 Standard Electrical angle 360 xx Optional 03 to 35; Declaration in 10 steps 99 Optional Special angle Sensor principle 7 MH-C Mechanical version 27E1 Optional Servo mount size 11 ; magnetic type 1 27E2 Standard Servo mount size 11 ; magnetic type 2 27E9 Optional Special housing ; special magnetic acutator MH-C MH-C2 Custom magnetic X - Custom modification of the housing X - Custom cable / wires X - Sample rate in slow mode X - Switch functions TTL (max. 2) X - Special characteristic curve - - Special electrical angle within 30 to 360 (ex factory) X - Electrical angle programmable (Software) - - Start & end point settable (Additional wires) - - Sense of rotation CW/CCW settable / programmable (Additional wires or Software) - - Index point settable / programmable (Additional wires or Software) - - Options (on request)

Vert-X 27E2 xxx xxx 2xx Vert-X 27E2 xxx xxx 7xx Vert-X 27E2 xxx xxx 1xx Vert-X 27E2 xxx xxx 6xx

Vert-X 27E1 xxx xxx 2xx Vert-X 27E1 xxx xxx 7xx Vert-X 27E1 xxx xxx 1xx Vert-X 27E1 xxx xxx 6xx

Vert-X 27E2 Mounting information Working position (Z) MH-C 12.80mm MH-C redundant 12.30mm Max. permitted misalignment dx dy dz ±0.5mm Vert-X 27E1 Mounting information Working position (Z) MH-C 1.40mm MH-C redundant 0.90mm Max. permitted misalignment dx dy dz ±0.5mm

Vert-X 27E Accessoires Fixation clip