Medium Voltage Products. KECA 80 C85 Indoor current sensor

Similar documents
KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor

KEVA B Indoor voltage sensor

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors for Cellpack separable connectors

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

Sensor Technology. Applications for medium voltage

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

AT Current Instrument Transformer Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

1/23/2003. Sensor presentation

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

ROG4K. EM210 energy analyzer current sensor ( A) Benefits. Description

Measuring current transformers of the W, W series

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

ABB CUSTOMER WORLD, MARCH 13-16, 2017 Sensors in Critical Applications Ron Pate, Product Manager, Instrument Transformers and Sensors

I Pr I P I OUT R L. Applications. Standards

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER

T-Line, current transformers

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

3. COMBINED TRANSFORMERS Oil-paper insulation

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Enhanced Quality with a Touch of Style

DATA SHEET. Switchboard instruments,

Network Analyzer for Low-, Medium- and High-Voltage Networks

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

Solutions to Consider in Current Transformer Selection for APR1400 Nuclear Power Plant Medium Voltage Switchgears

World-Class Accuracy & Measurement Range (40 Conventional Models)

Back to the Basics Current Transformer (CT) Testing

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

CP CU1. Coupling unit for line and ground testing

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

Accurate Current Measurement Transducer for Relaying Purpose

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

Flexible AC current probes

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Summation current transformers, type KSU/SUSK

I -limiter The world s fastest switching device

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Three-Phase Transformer Demagnetizer DEM60

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

N. TEST TEST DESCRIPTION

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

50-SDMS-01 SPECIFICATIONS FOR

Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

e 2 TANGO-50 Short-Circuit Detector K Data Sheet

Measuring current transformers of the W B series

SPECIFICATION Item no.: T60404-N4646-X400

LOPO. Low Power Instrument Transformers. For Medium Voltage Switchgear

Alternative Testing Techniques for Current Transformers. Dinesh Chhajer, PE Technical Support Group MEGGER

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

CT Analyzer. Revolution in current transformer testing and calibration

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

Differential Protection with REF 542plus Feeder Terminal

Accessories. Accessories

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

INSTRUMENT TRANSFORMERS. Product Spectrum

Capacitor Switching Contactors

LENORD. +BAUER... automates motion. GEL 2037 with heavy duty flange or tooth wheel adapter. Technical information Version General.

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

W DATA SHEET Current Transformer 40 x 10, A

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

METRAClip87 and 88 Clamp Multimeters

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Medium-voltage transfomers

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

K Factor Power Transformers

Stabilized Differential Relay SPAD 346. Product Guide

Protection and safety SQZ3 phase and sequence relay

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Transcription:

Medium Voltage Products KECA 80 C85 Indoor current sensor

Parameters for Application Value Rated primary current of application up to 2 500 A Sensor Parameters Value Highest voltage for equipment, U m 0.72 kv Rated power frequency withstand voltage 3 kv Rated primary current, I pr 80 A Rated continuous thermal current, I cth 2 500 A Rated transformation ratio, K ra 80 A/ 150 mv at 50 Hz 180 mv at 60 Hz Current accuracy class 0.5/5P630 Length of cable 2.2; 3.4; 3.6; 5 m With KECA 80 C85 sensors measuring class 0.5 is reached for continuous current measurement in the extended accuracy range from 5% of the rated primary current I pr not only up to 120% of I pr (as being common for conventional current transformers), but even up to the rated continuous thermal current I cth. For dynamic current measurement (protection purposes) the ABB sensors KECA 80 C85 fulfill requirements of protection class 5P up to an impressive value reaching the rated short-time thermal current I th. That provides the possibility to designate the corresponding accuracy class as 5P630, proving excellent linearity and accuracy measurements. Current sensor Current measurement in KECA 80 C85 sensors is based on the Rogowski coil principle. A Rogowski coil is a toroidal coil, without an iron core, placed around the primary conductor in the same way as the secondary winding in a current transformer. However, the output signal from a Rogowski coil is not a current, but a voltage Sensor principles Electronic Instrument Transformers (Sensors) offer an alternative way of making the current measurements needed for the protection and monitoring of medium voltage power systems. Sensors based on alternative principles have been introduced as successors to conventional instrument transformers in order to significantly reduce size, increase safety, and to provide greater rating standardization and a wider functionality range. These well known principles can only be fully utilized in combination with versatile electronic relays. Sensor characteristics Construction of ABB s current sensors is done without the use of a ferromagnetic core. This fact results in several important benefits for the user and the application. The main benefit is that the behavior of the sensor is not influenced by non-linearity and width of hysteresis curve, which results in a highly accurate and linear response over a wide dynamic range of measured quantities. A linear and highly accurate sensor characteristic in the full operating range enables the combination of metering and protection classes in one winding. Fig. 2. Rogowski coil principle u s (t) = M di p (t) Protection and control IEDs (Intelligent Electronic Devices) Protection and control IEDs incorporate the functions of a traditional relay, as well as allow new additional functions. The information transmitted from the sensors to the IED is very accurate, providing the possibility of versatile relay functionality. However, the IED must be able to operate with sufficient accuracy at a sensor s low input signal level, and the signal from the Rogowski coil must be integrated. Modern IEDs (such as ABB s 601series relays) are designed for such sensor use, and they are also equipped with built-in integrators for Rogowski coil sensor inputs. dt Fig. 1. Sensor characteristics 2 KECA 80 C85 Indoor current sensor

Modern digital apparatuses (microprocessor based relays) allow protection and measurement functions to be combined. They fully support current sensing realized by the single sensor with double the accuracy class designation (e.g. current sensing with combined accuracy class 0.5/5P630). The accuracy limits are described on the graph below. Fig. 3. IED and sensor Fig. 4. Combined accuracy class Sensor applications The current sensors type KECA 80 C85 are intended for use in current measurement in low voltage or medium voltage switchgear. In case of medium voltage switchgear the current sensor shall be installed over a bushing insulator, insulated cable, insulated & shielded cable connectors or any other type of insulated conductor. The current sensor is equipped with a clamping system which provides easy and fast installation and therefore makes the sensor suitable for retrofit purposes. Linearity Due to the absence of a ferromagnetic core the sensor has a linear response over a very wide primary current range, far exceeding the typical CT range. Thus, current sensing for both measurement and protection purposes could be realized with single secondary winding with a double rating. In addition, one standard sensor can be used for a broad range of rated currents and is also capable of precisely transferring signals containing frequencies different from rated ones. For this type of sensor, the variation of amplitude and phase error or composite error in a current range from 5% of rated primary current Ipr up to the rated short-time thermal current Ith is within the limits specified by IEC 60044-8. Example of current measurement range with rated current 80 A and accuracy class 0.5/5P630 Metering accuracy class 0.5 is, according to the IEC 60044-8 standard, guaranteed from 5% of I pr up to K pcr where K pcr is rated extended primary current factor and I pr is rated primary current. Factor K pcr is in the case of conventional CTs usually just 1.2, but in the case of the KECA 80 C85 sensor the K pcr factor is several times higher and equals 31.25. Protection accuracy 5P630 is guaranteed, for the advanced KECA 80 C85 sensor, from the current equal to K pcr up to the current corresponding to K alf value, where K alf is, according to IEC 60044-8, the accuracy limit factor. For this type of sensor the value of K pcr is equal to the rated continuous thermal current I cth (2 500 A) and the value of K alf is equal to the rated short-time thermal current I th (50 ka). Compactness Since the sensing elements are particularly small, and the same elements are used for both measurement and protection, the current sensors can be easily integrated into other equipment. Rated parameters Because the sensors are highly linear within a very wide range of currents, the same single sensor can be used for the various rated currents associated with each specific application up to the specified maximum voltage for equipment. There is no need to specify other parameters such as burden, safety factor, etc. since they are standard over the defined range. To achieve the correct function of the protection and control IED, the selected rated current, as well as the rated transformation ratio, must be properly set into the IED. Energy savings concept As there is no iron core, no necessity for high burden values and thus a possibility for low current losses and only one secondary winding needed, KECA 80 C85 sensors exhibit extremely low energy consumption that is just a fraction of that transferred to heat in conventional CTs. This fact contributes to huge energy savings during its entire operating life, supporting the world-wide effort to reduce energy consumption. Correction factors The amplitude and phase error of a current sensor is, in practice, constant and independent of the primary current. Due to this fact it is an inherent and constant property of each sensor and it is not considered as unpredictable and influenced error. Hence, it can be easily corrected in the IED by using appropriate correction factors, stated separately for every sensor. Values of the correction factors for the amplitude and phase error of a current sensor are mentioned on the sensor label (for more information please refer to Instructions for installation, use and maintenance) and should be uploaded without any modification into the IED before the sensors are put into operation (please check available correction in the IED manual). To achieve required accuracy classes it is recommended to use all correction factors (Cfs) amplitude correction factor (ai) and phase error correction factor (pi) of a current sensor. Indoor current sensor KECA 80 C85 3

Highest voltage for equipment and test voltages Highest voltage for equipment, U m Power frequency voltage withstand test on primary terminals 0.72 kv 3 kv Fig. 5. Example of a sensor label Secondary cables The sensor is equipped with a cable for connection with the IED. The cable connector is type RJ-45. The sensor accuracy classes are verified up to the RJ-45 connector, i.e. considering also its secondary cable. These cables are intended to be connected directly to the IED, and subsequently neither burden calculation nor secondary wiring is needed. Every sensor is therefore accuracy tested when equipped with its own cable and connector. For applications where standard lengths of secondary cables are not sufficient and longer secondary cable would be needed were designed extension cables. Two variants are available, extension cable CE 1.15 with the length 1.15 m and extension cable CE 8.00 with the length 8.0 m. Please note that use of extension cables is possible only for sensor product variant equipped with secondary cable with length 2.2 m. Current sensor, rated values Rated primary current, I pr 80 A Rated transformation ratio, K ra 80 A/0.150 V at 50 Hz 80 A/0.180 V at 60 Hz Rated secondary output, U sr 3 mv/hz i.e. 150 mv at 50 Hz or 180 mv at 60 Hz Rated continuous thermal current, I cth 2 500 A Rated short-time thermal current, I th 50 ka/3s Rated dynamic current, I dyn 125 ka Rated frequency, f r 50/60 Hz Rated extended primary current factor, K pcr 31.25 Accuracy limit factor, K alf 630 Accuracy class 0.5/5P630 Rated burden, R br 10 MΩ Temperature category Operation Transport and storage - 25 C/+80 C - 40 C/+80 C For more information about extension cables refer to Doc. No. 1VLC000710 - Sensor accessories. Cable Length Connector Grounding wire length 2.2; 3.4; 3.6; 5 m RJ-45 (CAT-6) 0.25 m Ordering data KECA 80 C85 (cable length 2.2 m) KECA 80 C85 (cable length 3.6 m) KECA 80 C85 (cable length 3.4 m) KECA 80 C85 (cable length 5 m) 1VL5400056V0101 1VL5400056V0102 1VL5400056V0103 1VL5400056V0104 Fig. 6. Connector RJ-45 Standards Current sensors IEC 60044-8 (2002-07) Instrument transformers Part 8 Electronic current transformers Accessories Clamping system 1VL5300808R0101 (rotary clamps 4 pcs, cable tie 1 pc) Note Use only in case that original rotary clamps have been damaged. Dimensions and weight Outline drawing number Weight 2RKA015224 0.25 kg 4 KECA 80 C85 Indoor current sensor

Dimensional Drawing KECA 80 C85 KECA 80 C85 Indoor current sensor KECA 80 C85 5

Contact us ABB s.r.o. EPMV Brno Videnska 117, 619 00 Brno, Czech Republic Tel. +420 547 152 082 +420 547 152 614 Fax +420 547 152 626 E-mail info.ejf@cz.abb.com 1VLC000715 Rev.4 en 2017.05.16 www.abb.com The data and illustrations are not binding. We reserve the right to make changes without notice in the course of technical development of the product. Copyright 2017 ABB. All rights reserved.