INSTALLATION INSTRUCTIONS

Similar documents
BFS / BFSM SERIES Installation & Maintenance Manual

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

AGASTAT GP/ML/TR Series, 10 Amp Control Relay, Non-latching, Latching & Timing Versions

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Series R48 Single Zone Load Sequenced Economizer System: Installation & Troubleshooting

INSTALLATION AND OPERATING INSTRUCTIONS

VENTI-LIGHT VLD. Ventilatie Indicator G e b r u i k e r s h a n d l e i d i n g. Ampèrestraat NL-1446 TR PURMEREND

W7100A-E Discharge Air Controller

Smartzone LCD TOUCHPAD USER GUIDE.

Spring Return DuraDrive Proportional Actuator

SmartZone-2 & SmartZone-4

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Measurement Board Product Number:

Digital Room Sensor Technical Guide

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

INTAC Microprocessor Humidifier Controller

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

HT-1A Dual Band CW QRP Transceiver. Kit Building Instructions

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

Service Information System

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

DP2500 DP0100 DP0250 Differential Pressure Transmitter

RK PPM Hexane Transmitter Operator s Manual

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

MODEL 671C CONDUCTIVITY ANALYZER

UNIVERSAL INPUT RESISTANCE OUTPUT

AMC mA Positioner

HLC-1000 High-limit Humidity Control

Ultimate Actuator Drivebox 30A Quick start guide

Toyota Sienna IPod Interface

LM Series Direct Coupled Actuator

ELECTRONIC THERMOSTAT: T920

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

Installation, Operation and Maintenance Manual

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Installation, Operation and Maintenance Manual

Courtesy of:discountcarstereo.com BT-BKRNP. Bluetooth Harness Installation Guide for Becker Aux Ready Radios Created March1, 2017

1073 & 1084 Channel Amplifier

Installation Instructions

RK Hydrogen Transmitter Operator s Manual

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

Technical Instructions Document No EA GQD June 23, OpenAir

TMC3 SERVO CARD For WEM/XEM Series Actuators Installation & Maintenance Manual

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

DP2500 DP0100 DP0250 Differential Pressure Transmitter

PART # mA Positioner

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

Non-Spring Return DuraDrive Modulating Actuator

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Non-Spring Return EconoDrive Proportional Actuator

* * APPLICABLE MODELS: 2014 > MAZDA 3

TA2. series. Industrial Motion. Product Segments

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

User s Manuals. 4-20mA current loop module MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS

Temperature Controller Replacement

LBI-4938C. Mobile Communications MASTR II POWER AMPLIFIER MODELS 4EF4A1,2,3. Printed in U.S.A. Maintenance Manual

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

CIC ENGINEERING 345 CENTER STREET EAST PEORIA, IL PH FAX

Quantum LX Temperature Input Signal Testing

with Light Level, Isolated Relay and Manual On features

QPM Series Indoor Air Quality Duct Sensors

SRC-110 Series Zone Controllers with Modbus RTU

FEATURES OPTIONAL FEATURES

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

EO Modulator Driver and Source Models 3363-A, 3363-B, and 3363-C

CA SERIES PRECISION REGULATED, LOW RIPPLE HIGH VOLTAGE DC TO DC CONVERTERS

DR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION

Series 48 Water Cooled Laser & UC-2000 Quick Start Guide

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A.

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

OVEN INDUSTRIES, INC. Model 5C7-362

E-BUS Digital Room Sensor Technical Guide

Guide to Operation. Sat-Ex 4-20mA Versions Sat-Ex mA Sat-Ex mA/R Sat-Ex mA/C Sat-Ex mA/C/R

Change 4 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR VOLTAGE STANDARAD, JOHN FLUKE, MODELS 332A, 332B, AND 332B/AF

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

Mod-E Pro Electric L-Shaped Standing Desk

Technical Data Sheet. Sensoric 4-20 ma Transmitter Board

MULTI-PURPOSE SCOREBOARD

BULLETIN # B

The CO2 Sensor Calibration Kit

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

TD-1 Tone Decoder / Trigger Version 1.0

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

CA SERIES PRECISION REGULATED, LOW RIPPLE HIGH VOLTAGE DC TO DC CONVERTERS

Modbus VAV Controller Configuration Properties

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

M211748EN-F. User Guide. Vaisala CARBOCAP Carbon Dioxide, Humidity and Temperature Transmitters. GMW80 Series

500mA Laser Diode Controller

Actuating Terminal Equipment Controller (ATEC) Base VAV - Cooling or Heating, Application Application Note

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Courtesy of:discountcarstereo.com USB-BKR. Quick Start Installation Guide for Becker AUX Ready Radios. Works on Becker radios with AUX menu option

Service case with test unit for servo and proportional valves with integral electronics (OBE)

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS. ITEM QTY DESCRIPTION Usage Chart

LESLIE CONSOLE CONNECTOR KIT 7043 INSTALLATION INSTRUCTIONS

Technical Data Sensor Input Input voltage measuring range (FSO) V 0 ±10 Max. input voltage V <±15 Resolution mv 5 with oversampling 14 Bit mv

Transcription:

INSTALLATION INSTRUCTIONS CO2 SENSOR, WALL MOUNT MODEL# 2AQ04700324B WARNING: BEFORE INSTALLING READ ALL OF THE MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS Ship ping and Pack ing List 1 ea. CO 2 Sensor 1 ea. CO 2 Sensor Base 1 ea. 0-10 VDC Potentiometer Signal Converter (Honeywell Q769C) 1 ea. CO 2 Sensor Splice Wiring Harness (W7212 Economizer Control) 1 ea. 4" Violet Wire 1 ea. 4" Red Wire Ap pli ca tion for W7212 Economizer Con trol Mount CO2 Sensor base on wall. Route wires (raw end) through square hole in base and connect per wiring diagrams. Attach CO2 Sensor. Use supplied "Splice" harness to obtain power; See Diagram # 80CO202. Program the CO 2 sensor per the specifications, provided with the accessory, to suit the application. Q769C BOX Ap pli ca tion for W7459 Economizer Con trol Install the Honeywell Q769C potentiometer signal converter. Disconnect the (P-P1) jumper from the economizer control located on the actuator and connect the Q769C per wiring Diagram # 80CO201. Make sure to secure the Q769C device using the included wire ties. Power the CO 2 device via a properly protected, field supplied, non-grounded transformer of the appropriate primary and secondary voltage per the attached Diagram # 80CO201. Program the CO 2 sensor per the specifications, provided with the accessory, to suit the application. CO2 SENSOR For recommended settings for adjustments of economizer and programming of CO2 sensor refer to next few pages. NOVEMBER 29, 2010 661421-UAI-A-1010 YKICO203B

M7415 W7459A WIRE Q769C TO ECONOMIZER CALIBRATION POTENTIOMETER SET MINIMUM POSITION POTENTIOMETER TO Calibration chart. 8-Pin and 2-Pin Terminal Block Pin Designations on the Ventostat Mounting Bracket 2-10 Vdc CONTROLLER Q769C Adapter connected to M7415 Actuator and W7459A Economizer for 0-2 to 10 Vdc control. ADJUSTMENT Minimum Position Adjustment NOTE: When using the Q769 with the M7415, separate transformer must be used to power the M7415 and the controller. TR1, P1 and (+) on the Q769 are all internally connected. The Q769C Adapter sets the minimum position of an M7405 or M7415 Actuator, based on a 0 to 10 Vdc or 2 to 10 Vdc signal. In an economizer system, the actuator adjusts outdoor air for cooling. The Q769C is used to set the minimum position so that a specified amount of fresh air is admitted. To adjust the Q769C on an M7405 or M7415 Actuator, proceed as follows: 1. Run the actuator to the fully closed position and disconnect 24 Vac from terminals TR and TR1. 2. Connect the Q769C 0-2 to 10 Vdc Adapter to terminals P and P1. 3. Reconnect 24 Vac to terminals TR and TR1 and adjust the input signal (0 to 10 Vdc or 2 to 10 Vdc) for the desired minimum position. The Q769C calibration potentiometer is factory adjusted so that the actuator begins to modulate open from the closed position at 2.4 Vdc for the 2 to 10 Vdc controller (0.4 Vdc for the 0 to 10 Vdc controller) with the calibration potentiometer set at the midrange position. As shipped from the factory, an M7405/M7415 Actuator begins to modulate closed from the fully open position at 9.8 Vdc. The exact voltage values depend primarily on the regulated dc voltage of the actuator. Calibration points are shown in calibration chart. With the calibration potentiometer turned fully ccw or fully cw, the actuator leaves the closed or open positions at lower or higher voltages, respectively, than at the calibration points. With the calibration potentiometer in the fully counterclockwise position, the actuator leaves the closed position even without an input signal. + Signal from Q769C adapter is to connect to #8 - Signal connects to #7 NOTE: 24V- Do not use HVAC unit transformer. Provide 24V by non-grounding transformer. Honeywell Damper Actuator M7415 and W7459 Logic Module Optional High and/or Low Temp Switch Honeywell Q769 0-10 Vdc Adaptor Honeywell Damper Actuator M7415 and W7459 Logic Module Set minimum POSITION potentiometer to twice the design load. For example, if the space is designed for 30 people at 15 cfm/person, adjust the minimum position potentiometer at the economizer logic to 900 cfm. This will allow the economizer to introduce 450 cfm (1000 ppm CO2 level) at the design load.

Setting No Type of Equip ment Type of Output Ven ti la tion Rate (cfm/ Per son) Analog Output CO2 Con trol Range (ppm) Optional Re lay Setpoint (ppm) Re lay Hys ter esis (ppm) 1 In ter face w/stan dard Build ing Con trol Sys tem Proportional Any 0-10V, 4-20mA 0-2000 1000 50 2 In ter face w/stan dard Build ing Con trol Sys tem Proportional Any 2-10V, 7-20mA 0-2000 1000 50 3 In ter face w/stan dard Build ing Con trol Sys tem Exponential Any 0-10V, 4-20mA 0-2000 1100 50 4 Economizer (Hvac) Proportional 15 0-10V, 4-20mA 0-1100 1100 50 5 Economizer (Hvac) Proportional 20 0-10V, 4-20mA 0-900 900 50 6 Economizer (Hvac) Exponential 15 0-10V, 4-20mA 0-1100 1100 50 7 Economizer (Hvac) Exponential 20 0-10V, 4-20mA 0-900 900 50 8 Health & Safety Proportional NA 0-10V, 4-20mA 0-9999 5000 500 9 Park ing/air In takes/load ing Docks Proportional NA 0-10V, 4-20mA 0-2000 700 50 Standard Settings Adjustable via keypad Settings 4 to 7 are specifically designed for operation with economizer controls and actuators where a 0-10 VDC signal will provide 0-100% outside air modulation. These control settings provide different modulation ranges depending on the target cfm-per-person ventilation rate desired. As described below the exponential setting is best used in applications that have large volumes of air and people such as auditoriums, gyms and large conference areas. Se lect ing a Pre-Pro grammed Set ting: The pre-programmed settings shown in the Standard Settings Table are factory set and cannot be changed. These settings can be selected from the Standard Settings (STDSET) menu. 1. After 2 minute warm-up period, press CLEAR + MODE and hold (at least 5 seconds) until the sensor enters the edit mode. 2. Press MODE 2 times. You will enter the STDSET menu. 3. Use the UP/DOWN button to select the desired pre-programmed number. 4. Press ENTER to lock selection, press MODE to return to Normal Mode.

W7459 - Economizer Logic Module P# - Plug Connector S# - Socket Connector Transformer must not be grounded Note: The socket and plug numbers change per unit. Date: October 10, 2002 Supercedes: Diagram# 80CO201

SPLICE HARNESS Note: The socket and plug numbers change per unit. SDRA - Smoke Detector, Return Air W7212 - Economizer Logic Module P# - Plug Connector S# - Socket Connector Jumper Located on T-stat Interface Board Date: October 10, 2002 Supercedes: 09-11-02 Diagram# 80CO202