Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

Similar documents
Miniature Synchronous Multipoint Modems

Interface converter G kbit/sec

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

FOM-5A, 6A Asynchronous Fiber Optic Modems

Modem E1. Modem-converter E1-L. Features. Contents

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

FOM-4SF Sync/Async Single Fiber Modem

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

USER'S MANUAL. Model : K

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Multiplexer - Voice Transcoder E1-XLC

Atrie WireSpan 600/610 MODEM User's Manual

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Chapter 12: Digital Modulation and Modems

Concept of Serial Communication

ROM/UDF CPU I/O I/O I/O RAM

NETWORK. TE = Terminal Equipment (DTE - Data Terminal Equipment) NT = Network - Terminating Equipment (DCE - Data Circuit - Terminating Equipment)

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

TTU01/V35 TTU01/X21 TTU01/449 TTU01/530

Appendix A. Datum Systems PSM-2100/512 Satellite Modem. Technical Specification

M9606. FSK Modem. 5C Communications Inc.

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

This FAQ covers Single Direction use of current loop with transmitting devices.

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

Myriad MD9612FP Flash Poll Rack-Mount Modem User s Guide MD9612FP USER S GUIDE XXX Page i REV. A

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

This FAQ covers the common questions from technicians installing these converters.

CP485-4 User s Manual

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

Stat-4 Stat-8 Stat-24

ANALOG AND DIGITAL PHYSICAL INTERFACES

9600 bps, Dual Modem 170 Card Private Wire Only

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

MODEL FLD-496SA 9600 Baud FIBER OPTIC/FSK MODEM

Interface Description Peak MTT

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

)454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

2W UHF MHz Radio Transceiver

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

ZCS485 User s Manual. Version ZYPEX, Inc.

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

Lecture #3 RS232 & 485 protocols

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

USER'S MANUAL. Models : 5000N/5000NV/7000N/7000NV

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

DDS-PLL SYNTHESIZER DPL-2.5GF USER S MANUAL DIGITAL SIGNAL TECHNOLOGY, INC.

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

LDM85. Fiber Optic Modem. Description. Features. Specifications

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

OPERATION MANUAL INSTALLATION AND KHS.1. 2-Channel High-Speed Data Module. Kilomux I/O Module. The Access Company

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

ECE 4510/5530 Microcontroller Applications Week 6 Lab 5

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

APPLICATION NOTE ANI6. Connecting the SP504 Multiprotocol Transceiver to the 85C30 Universal Enhanced Serial Communications Controller (ESCC)

MODEL 800. GDI Communications, LLC. Dual 1200 BAUD Modem. Verdi, Nevada. rzidnanga-arnnt= Pnnc1 rsf 17

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Installation Manual Console Integration System

King Fahd University of Petroleum & Minerals Computer Engineering Dept

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

Model RTX-12 Radio Modem

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

MDW-45 Converter RS RS-422/485

TCSS 372 Laboratory Project 2 RS 232 Serial I/O Interface

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

Guardian and DL3282 Modem Interface Technical Service Application Note

LBI Installation & Operation

1.0 Introduction. Related Products and Documentation

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

MGE TM Galaxy TM , 60 Hz kva

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

The wireless alternative to expensive cabling...

USER MANUAL G703FTEC. T1/E1 Cross Rate Converter

HR1200. Version 1.00 ATIM RADIOCOMMUNICATION 1/11

EC Declaration of Conformity

MODEL: DLS. Telemetering System

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION OVER THE TELEPHONE NETWORK

SNV-12 Voter Quick Reference Help Sheets

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

TS4000 Radio Modem. User s Manual

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

USER MANUAL MODEL 1186 Multi-Mode Fiber Modem with Fixed G.703/G.704 Interface

TTC INTERCEPTO R 147. Artisan Technology Group - Quality Instrumentation... Guaranteed (888) 88-SOURCE

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-19. Korthållsmodem Short Haul Modem Kurzstreckenmodem

Transcription:

BLACK BOX PWR RTS TD-1 RD-1 TD-2 DCD RD-2 TEST DIG ANA REM LDM-MR 19.2 REM ANA DIG AGC 2/4 WIRE ABLE / ABLE SWITCHES 2 W 4 W 1 2 3 4 CARRIER LEVEL 0 dbm -3 dbm -6 dbm -9 dbm PIN 21 (RLB) RPF PIN 18 AN. LP TEST ASY LGTH TIMING INT. CLK EXT. CLK. CLK ASYNC DB25 CNECTOR 0 msec 8 msec 64 msec IMPD DCD RD CTS DELAY ME760AE TD 2 RTS DATA RATE SELECTI PWR IMPD HIGH Cable Required: Between ME760A units: Unloaded twisted pair, 19 to 26 gauge; 4-wires for full duplex, at least 2 wires for half-duplex; DC continuity not required; Between ME760A unit and DTE: EIA RS-232 cable with DB25 male connector on ME760A end. Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable). Protocol: Synchronous or Asynchronous Clock Source: Either internal, external from local DTE, or recovered from remote DTE. Data Format: 5, 6, 7 or 8 data bits; 1, 1.5, or 2 stop bits; even, odd, or no parity. Operation: 2- or 4-wire half-duplex or 4-wire full-duplex; point-to-point or multipoint. Data Rate: Sync: 1.2, 2.4, 3.6, 4.8, 7.2, 9.6, 14.4, or 19.2 Kbps; Async: Up to 19.2 Kbps. Modulation: Differential diphase Eurocom Standard D1 Transmit Level: 0, -3, -6, or -9 dbm (user-selectable). Transmit Impedance:,, or "" ohms (user-selectable). Receive Impedance:,, or "HIGH" ohms (user-selectable). Return Loss: Greater than 15 db. Carrier: Controlled by RTS or constantly (user-selectable). SPECIFICATIS: User Controls: (21) Total: (3) Front-mounted pushbuttons: DIG (local digital loopback) ANA (local analog loopback) REM (remote digital loopback) (18) Internal: (1) Dial: Data Rate; (5) Single-position DIP switches: (1) Enable/Disable front-panel pushbuttons; (1) Async character length; (1) Not used: (12) Jumpers: Transmit Timing; 2- or 4-wire operation; CTS Delay; Carrier Control; Transmit Level; Transmit-line Impedance; Receive-line Impedance; Enable/Disable analog-loopback command on Pin 18; Enable/Disable remoteloopback command on Pin 21; Connect/ Disconnect signal ground and chassis ground AGC control; Activate/Deactivate V.54 delay. Diagnostics: Comply with V.54 standard: Local analog loopback, mechanically or electrical user-controllable; Local digital loopback, mechanically user-controllable; Remote digital loopback, mechanically or electrically user-controllable. Indicators: (6) Front-mounted LED's: PWR, RTS, TD, RD, DCD, TEST. Connectors: (2) Rear-mounted: (1) DB25 for cable to DTE, (1) 4-wire terminal block for modem-to-modem line. Power: Directly from outlet through attached 5-ft. (1.5m) line cord: ME760A: 230 VAC, 47 to 63 Hz, 3 watts.

INTRODUCTI: The LDM-MR19.2 is a short-range modem which operates at full- or half-duplex with synchronous or asynchronous transmission over unconditioned telephone lines. With an extended range of up to 34 miles (55 km), the LDM-MR19.2 operates at any of eight selectable data rates, up to 19,200 bps. By using conditioned differential diphase modulation (Eurocom Std. D1), the LDM-MR19.2 provides immunity from background noise, eliminates normal line distortion, and enables efficient transmission and reception of serial data over twisted-pair cable. The LDM-MR19.2 is coupled to the telephone line through isolation transformers. The transformers and electronic circuitry protect against AC or DC overvoltages. The protection circuitry allows operation even when DC is connected to the line because of the following: Transmit Level and Transmit Receive impedance's are independently selectable. Transmit timing is provided internally, derived externally from the data terminal, or regenerated from the Receive signal. Receive timing is regenerated from the Receive signal. Line communication is always synchronous. when you set the modem to asynchronous mode, it performs as async-to-sync conversion in compliance with the CCITT V.22 bis standard. The LDM-MR19.2 also features V.54 diagnostic capabilities for performing local analog loopback and local and remote digital loopback. In the digital loopback mode, the operator at either end of the line may test both of the modems and the line. The operator can control the loopback with either the front-panel pushbuttons or Pins 18 and 21 of the V.24/RS-232 interface. FUNCTIAL DESCRIPTI: CODER: The encoder modulates the input data from the DTE using the "conditional diphase modulation" technique. You can configure the encoder to operate in one of five modes: 1. 4-wire full-duplex 2. 4-wire half-duplex 3. 2-wire half-duplex 4. 4-wire multipoint 5. 2-wire multipoint MODULATI TIMING: The modulation-timing circuit supplies the Transmit clock to the encoder. Four clock sources are available: 1. INT. CLK.= internal clock--from the modem's internal crystal oscillator. 2. EXT. CLK. = external clock--from DTE, Pin 24. 3.. CLK = receive clock recovered from Receive signal. 4. ASYNC = asynchronous timing for working with the async-to-sync converter in an async application. Setting the TIMING jumpers determines the timing option. ASYNC-TO-SYNC CVERTER: The LDM-MR19.2 provides internal conversion from async to sync in compliance with CCITT V.2 bis. According to this standard, frequency deviation between the modem and the DTE is compensated for by shortening or lengthening the stop bit of the async character. When the modem's frequency is higher than the DTE's, the local converter extends the stop bit. When the modem's frequency is lower than the DTE's the local converter may delete one stop bit every four or eight characters. The remote converter adds a shorter stop bit before sending the data to the remote DTE. For frequency deviations of up to 1.1%, the stop bits should be shortened every eight characters (12.5%). For frequency deviations of 1.2 % to 2.3%, the stop bits should be shortened every four characters (25%). User Switch position 2 (S2) of the "ASYNC LGTH" DIP switch to select 25% or 12.5% frequency deviation. For proper operation of the async-to-sync converter, set the async character length by adjusting switch positions 3 and 4 (S3 and S4) of the "ASYNC LGTH" DIP switch. LEVEL: Four options are available for the level (signal level): 0, -3, -6, or -9 dbm. level is controlled by the LEVEL jumper. RECEIVER: The receiver contains several circuits. 1. The RECEIVE FILTER removes all the out-of-band frequencies. 2. The AUTOMATIC EQUALIZER is made up of several equalizers activated according to data rate. 3. The digital AGC (automatic gain control) automatically compensates for the attenuation of the line. You may choose between the two modes of AGC operations by setting the AGC jumper: : The AGC operates continuously. CNTR: The AGC is active only when DCD is. When DCD is, the AGC will remain in the state to which it was most recently set. In full-duplex point-to-point applications, there is no difference between the two AGC modes of operation. However, there is a difference in multipoint applications, where the master modem communicates with modems at different distances. When the master modem is set to AGC-, the master can communicate across long distances (up to its maximum range) to the slave modems. However, this setting increases the RTS-to-CTS delay. For example, under AGC-, the CTS delay of all slaves must be set to 64 ms when the data rate is less than 9.6 Kbps. When the master modem is set to AGC-CNTR, it can't transmit or receive across as much distance. However, the polling goes faster. For example, under AGC-CNTR, the CTS delay of all units can be set to 8 ms when the data rate is greater than or equal to 4.8 Kbps. V.54 DIAGNOSTICS: You can activate V.54 loops with either the front-panel pushbuttons or Pins 18 and 21 can be enabled or disabled separately by the SWITCH, PIN 18 and PIN 21 jumpers, respectively. When you use the LDM-MR19.2 as a tail end to a DDS network, set the V.54 DELAYjumpers of the modems located close to the DDS network to to prevent multiple loopbacks. The DELAY switch prevents the last modem from receiving the complete V.54 data sequence and being induced into a loop. V.54 is required only for operation in synchronous mode. NOTE: The V.54 DELAY jumper must be set to when you operate in asynchronous mode.

INSTALLATI: Data Cables: The LDM-MR19.2's data-communication connectors (a four-screw terminal block and a DB25 connector) are on its rear panel. The terminal block holds four screws for connecting the Transmit () and Receive () telephone lines. The Transmit and Receive pairs are polarity insensitive. Connect the Transmit pair to the terminals; for 2-wire operation, this is all you need. For 4-wire operation, connect the Receive pair to the terminals. A nut for optional ground connection is located on the right side of the rear panel. Setting the Internal Controls: After you install the cabling, you'll need to configure the LDM-MR19.2 for your application by setting its internal straps (jumpers) and switches as necessary. To set internal jumpers and switches, follow these steps below. 1. Loosen the screw holding the top cover in place (located at the top of the rear panel. 2. Remove the top cover. 3. Adjust the jumpers and switches for the configuration you want. 4. Replace the top cover and tighten the retaining screw. OPERATI: Controls and Indicators: All of the LDM-MR19.2's external controls and LED indicators are located on the LDM-MR19.2's front panel. A. DIG: Pressing the Digital Loopback button causes the local LDM-MR19.2 to loop received data and clock to its transmitter. Data Set Ready goes low. B. ANA: Pressing the Analog Loopback (V.54 Loop) button causes the local LDM-MR19.2 to loop its transmitter output back to its receiver. This loopback can also be activated from the terminal when the Pin 18 strap is set to. C. REM: Pressing The Remote Digital Loopback (V.54 Loop 2) button causes the remote LDM-MR19.2 to loop received data and clock to its transmitter. Data Set Ready goes low. This loopback can also be activated from the terminal when the Pin 21 strap is set to RLB. 1. PWR: Green LED is when power is present. 2. RTS: Yellow LED is when DTE activates Request to Send. 3. TD: Yellow LED is when steady SPACE is being transmitted. It flickers when data is transmitted. 4. RD: Yellow LED is when steady SPACE is being received. It flickers when data is received. 5. DCD: Yellow LED is when a valid Receive signal is present. 6. TEST: Red LED is when the LDM-MR19.2 is in any of the three loopback modes. Turning the Unit : If you haven't already, plug the LDM-MR19.2's AC power cord into a working AC outlet. The PWR LED should light to indicate that the unit is. If the local and remote units are both operating and passing data, the LED's should look like this: PWR: TD: Flashing or RD: Flashing or RTS: or Flashing DCD: or Flashing TEST: If the LED's don't look like this, make sure none of the three front-panel pushbuttons are pushed in. Operating Procedure: The LDM-MR19.2 can operate entirely unattended. However, you should check the unit's LED indicators once in a while to make sure that everything is OK. While the unit is, operating personnel are not exposed to voltages in excess of 30 volts on any card or accessible area of the unit's DC power supply. Regardless of this, DO NOT open the unit while it is. Reconfiguration: If at some point you need to reconfigure the unit to operate differently, with a new data rate or new clock source, for example--you can change the settings of the unit's internal controls. Unplug the unit, then follow the procedure for possible settings of the controls.

STRAP IDTITY FUNCTI POSSIBLE SETTINGS FACTORY SETTINGS Data Rate (Kbps) Determines the data rate. 0 = 19.2 Kbps 1 = 14.4 Kbps 2 = 9.6 Kbps 3 = 7.2 Kbps 4 = 4.8 Kbps 5 = 3.6 Kbps 6 = 2.4 Kbps 7 = 1.2 Kbps 2 = 9.6 Kbps TIMING 2W/4W Determines whether the transmit-timing signal comes from the internal clock, external clock, or receive clock, or whether the unit operates in async. Determines whether the unit uses 2 wires or 4 wires. INT EXT ASY 0 ms CTS DELAY Determines the RTS-to-CTS delay 8 ms 8 ms 64 ms CARRIER LEVEL IMPEDANCE Determines the transmit carrier mode. : Transmit carrier is constantly. : Transmit carrier is only when RTS is high. should be used in multipoint applications. Determines transmit-output level to the line. Determines transmit-line impedance. For Multi-point applicatoins, set the master modem to 2W 4W 0 dbm -3 dbm -6 dbm -9 dbm INT (Internal Clock) 4W (4 wires) 0 dbm [ohms] STRAP IDTITY SWITCH AGC V.54 Delay ASYNC LGTH FUNCTI Enables/Disables control of the DIG, ANA, and REM loopbacks with the front-panel pushbuttons. Connect: Connects Signal Ground to Chassis Ground. : Isolates grounds from each other. : AGC always. : AGC if DCD is, remains at last level of amplification if DCD goes. : Activates V.54 delay, preventing multiple loopback of tail-end circuits. : No delay S3 and S4 determine character lengths when unit is in async mode. S2 determines amount of stop-bit shortening for async mode. S1 is not used. POSSIBLE SETTINGS CNECT CN S3 S4 BITS 8 9 10 11 = 25% = 12.5% FACTORY SETTINGS CNECT 10 Bits 12.5% IMPEDANCE Determines receive-line impedance. For Multi-point applications, set the master modem and the last modem in line 10 ; set all others to HIGH. HIGH [ohms] PIN 18 Enables/Disables Analog loopback command from the DTE on Pin 18 PIN 21 Enables/Disables Remote loopback command from the DTE on Pin 21. RLB RLB RLB

Point-to-Point Application GROUND IS OPTIAL GROUND IS OPTIAL 4-Wire Twisted Pair up to 34 mi. (55 km) IMP - IMP - ohm GROUND IS OPTIAL Multipoint Application GROUND IS OPTIAL Slave 1 IMP - ohm IMP - HIGH Slave 2 IMP - ohm IMP - HIGH Slave 3 IMP - ohm IMP - ohm