As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

Similar documents
PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

PML 711A-RO High impedance passive probe Features:

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

PKT 512A-RO High Impedance Passive Cable Divider

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

PHV RO High Voltage Passive Probe. Instruction Manual

400 MHz Passive High-Voltage Probe R&S RT-ZH

TK 100 Probe Calibrator. Instruction Manual

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

PDN Probes. P2100A/P2101A Data Sheet. 1-Port and 2-Port 50 ohm Passive Probes

TA MHz oscilloscope probe TA MHz oscilloscope probe

Operator s Manual. PP022 Passive Probe

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP017 and PP018 Passive Probes

Documentation. PerfectPulse Fast Edge Signal Generator

TT-SI MHz DIFFERENTIAL PROBE

Model /701913/ PBA1000/2500/1500 Active Probe

TT-SI MHz Active Differential Probe

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Oscilloscope Probes and Accessories

TT-SI MHz Active Differential Probe

N2792A and N2793A Differential Probes User s Guide

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

TT-SI 9001 / TT-SI MHz Active Differential Probes

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

20X Low Capacitance Probe P6158 Datasheet

Probing Techniques for Signal Performance Measurements in High Data Rate Testing

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

Passive Probe Ground Lead Effects

User s Manual. Model PBD2000 Differential Probe. IM E 1st Edition. Yokogawa Electric Corporation

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL


P331-2 set ESD generator (IEC )

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

AC/DC Current Probe TCP0150 Datasheet

IsoVu Optically Isolated DC - 1 GHz Measurement System Offers >120 db CMRR with 2kV Common Mode Range

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

Keysight Technologies InfiniiVision Oscilloscope Probes and Accessories

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

PBDH1000 Differential Probe

Keysight Technologies InfiniiMax III/III+ Probing System

TLP/VF-TLP/HMM Test System TLP-3010C/3011C Advanced TLP/HMM/HBM Solutions

PGB2 Series Halogen Free / Lead-Free

E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

ZS Series High Impedance Active Probes 2.5 GHz, 1.5 GHz and 1 GHz Probes

WaveLink High Bandwidth Differential Probing System (16 GHz 25 GHz)

P7600 Series TriMode Probes

Probing for oscilloscope

Instruction Manual CT-6 High Frequency AC Current Probe

AIM & THURLBY THANDAR INSTRUMENTS

The Inductance Loop Power Distribution in the Semiconductor Test Interface. Jason Mroczkowski Multitest

INSTRUCTIONS MODELS AVX-CA-SEMA TEST JIG FOR USE WITH AVTECH AVR-EB2A-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

SPLIT.CONVERTER. User's Manual. Version 2.0

Instruction Manual. P GHz Differential Probe

Passive Voltage Probes

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Accessories Selection Guide For Impedance Measurements. April 2005

AC Active Transmitter Combiner 8:1

Current Probe. Inspector Data Sheet. Low-noise, high quality measurement signal for side channel acquisition on embedded devices.

Agilent Accessories Selection Guide For Impedance Measurements. December 2008

Infiniium Series Oscilloscope Probes, Accessories, and Options

Demo Board LMH7220 High Speed LVDS Comparator

1.5 GHz Active Probe TAP1500 Datasheet

InfiniiVision Oscilloscope Probes and Accessories For 2000 X-, 3000 X-,

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

SCXI MHz Quad 8x1 50 Ω Multiplexer

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

13.56MHz Antennas APPLICATION-NOTE. OBID i-scan. Construction and tuning of 13.56MHz antennas for Reader power levels up to 1W

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Fluke 123/124 Industrial ScopeMeter

Technical Documentation

R&S FPC-Z10 Teaching Kit Getting Started

MD 200A High voltage differential probe

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

NI PXI/PXIe-2540 Specifications

Model Operating Manual

1157A 2.5 GHz Active Probe

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

Agilent IniniiVision Oscilloscope Probes and Accessories

User s Manual Current Probe IM E. 6th Edition

InfiniiMax III probing system

Transcription:

High impedance passive probe Features: 2.5 mm Diameter Tip Useable with any 50 Ω Instrument Interchangeable Spring Contact Tip IC Contacting System 0.5 to 1.27 mm pitch PMK introduces a new universal 10:1 miniature probe for oscilloscopes with up to 1.5 GHz bandwidth. As all PMK probes the features CeramCore TM technology. The entire probe core is made of a high quality ceramic hybrid. The probe is available with coaxial SMA, N and readout BNC connector to be automatically recognised as 10:1 divider by scopes that feature a sense ring to detect probe attenuation such as Agilent, LeCroy or Tektronix. Low Z-Miniature dividers are a low-cost alternative to active probes for high frequency measurements. They re built for use with instruments having 50 Ω inputs. Due to their low input impedance in the range up to 100 MHz the signal source must be able to accept some loading without difficulties. The compact design of this new probe with its 2.5 mm housing diameter at the tip provides better visibility to the DUT (device under test) in dense SMT circuits than conventional 5 mm housings. Due to the remarkably low input capacitance the signal source is only loaded by 1.8 pf. Less load to the measurement circuit can only be achieved with active probes. Especially when measuring signals with fast rise times often the probe s adaption to the source signal plays an important role. Long ground leads found on most conventional adaptions bring additional inductance and resonances into the setup which will result in false or inaccurate readings. The new IC contacting system consisting of five different IC adapters ranging from 1.27 to 0.5 mm pitch and the PCB adapter kit offer an ideal solution for short circuit-proof, reproducible measurements. As you would expect the probe is shipped with PMKs signature spring-loaded tips. In total there are 16 different accessories included in the scope of delivery with the new offering adaptive solutions for a variety of probing demands. 1

This datasheet supersedes all previously published material. Specifications that are not marked as guaranteed are published as general information to the user. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. Note that specifications are subject to change without notice. Electrical Specifications Attenuation Ratio (1) 10:1 ± 2 % at DC System Bandwidth 1.5 GHz (-3 db) System Risetime 240 ps (10% 90 %) Maximum Rated Input Voltage 12 V DC incl. AC peak Voltage Derating 15 Typical Voltage Derating PML 751 Amplitude DC incl. peak AC [V] Sinus 10 5 0 100k 1M 10M 100M 1G 10G Frequency [Hz] Note that the max. input voltage rating of the probe decreases as the frequency of the applied signal increases. (1) Connected to oscilloscope with an input impedance of 50 Ω ± 1 %. 2

Electrical Characteristics Input Resistance (system) 500 Ω ± 1 % Input Capacitance (system) 1.8 pf Input Coupling of the Measuring Instrument 50 Ω Input Impedance 1k Typical Typical input Input impedance Impedance PML PML751 Z Z [Ohm] 100 Note that the input impedance of the probe decreases as the frequency of the applied signal increases. 10 100k 1M 10M 100M 1G 10G Frequency Frequency [Hz] [Hz] Mechanical Characteristics Weight (probe only) Cable Length Probe Tip Diameter 48 g 1.3 m 2.5 mm 68,5 [ 2.697 ] O 3,5 [.140 ] O 18,85 [.742 ] O 2,5 [.098 ] 15 O [.591 ] 106,5 [ 4.193 ] 3

Environmental Specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature Range operating 0 C to +50 C non-operating -40 C to +71 C Maximum Relative Humidity operating 80% relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C WEEE/ RoHS Directives PMK electronic products are classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempt from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return any electronic product at the end of its life either to Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. * EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 4

Scope of Delivery Order No. 855-751-001 2 Footer Positioner 2x self adhesive Cu Pads Coding Rings (set) 3x4 colors Ground Blade 2.5 Ground Lead 11 cm Ground Spring 2.5 IC-Caps 0.5 to 1.27 mm pitch Instruction Manual Insulating Cap 2.5 PCB Adapter Kit 2.5 Probe Protection Cap 2.5 Solid Tip CuBe 0.5 mm Spring Tip 0.5 mm Sprung Hook 2.5 Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-Mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 Revision D Juli 2014 5