T-BAR LED Minimalist Look and maximised Utility

Similar documents
Tentec LED Lighting Solutions for Handrails and more

Mini Continuum II - Direct/Indirect

MARS Wall Wash Light where it s meant to be

CANOLUX 65 INTERIOR LIGHTING MODEL NUMBER Y117 - CANOLUX 65 SPECIFICATIONS

MARS INVISIBLY BRIGHT!

Laser Blade Line to Circle

Premium lighting environment for sustainable offices

LED Recessed Lighting

WhitePaper LED LED Basics

Lighting Depth: Physical Therapy Suite Franklin Care Center, Franklin Lakes, NJ

Sharp LED Lighting. Introduction. April 2015

ENR# Enlighted remote (5) WC# wireless control dimming. Specify quantity. Requires 8" blank See integrated controls guide for more details.

MacAdam Steps Colour consistency within 3 MacAdam steps (SDCM).

Light is impressive Siteco Vega

Gravity. High Power 4, 6 & 8-Inch Downlighting

LdG-2 Lighting design Guide for Vertical Surfaces

LEDTOUCH TM Skyline Datasheet

Purelite D LED. Maximum freedom of design. Because it s super flat.

Bridgelux V13 Array. Product Data Sheet DS44. BXRE-27x2000

ARCHITECTURAL MAGIQ INVADER BIONIQ MECHANIQ IMAGINE CENTRIQ

INPLANAI ONPLANA RADIANCE TO GET EXCITED ABOUT

RECESSED LUMINAIRE SERIES

Winter 2012 Winter 2012 LE 2D L 20 i-g 2 h 4 tin 0 g V Ca LE t Dalo Li g ghting Catalog

PENDANT MOUNT - DIRECT

Bridgelux Vesta Series Tunable White 9mm Array. Product Data Sheet DS152

Lightment. Lightment is emotional, visible innovation, underlining modern, architectural quality by clarity in design and electronic intelligence.

Commercial. Lighting.

INSPIRATION: SHOOTING STAR CARBON DIAMOND

2" LED Downlights and Adjustables. Energy-efficient, discreet aperture, high performance LED lighting

Catalogue R 03 R05 R 08 R10 R15 R18

Product Data Sheet DS45 BXEM-27E000 30x x x x4000

Product Data Sheet DS42 BXRE-27x x x x x1000

Purelite LED. Maximum freedom of design. Because it s super flat.

Light calculation example

RAIL / GRANDE RM2 & RM4 Series. by Metalumen

Product Data Sheet DS43 BXRE-27x x x x x3001

XOOMINAIRE For general and task lighting

Bridgelux Gen 7 V8 Array. Product Data Sheet DS104

Three optic options: 1. Advanced Hexaprism PMMA centre optic with prisms facing down for optimum glare control and diffusion

Technical Information

The Soft Celiling Luminaire.

Light is new defined Scriptus The innovative luminaire range for offices and public buildings.

Technical Application Guide for UP-SHINE LED Downlight UP-DL98A-8-25W-C3/UP-DL98B-8-25W-C3 UP-DL98A-8-25W-P3/UP-DL98B-8-25W-P3

PRODUCT CODE FIXTURE COLOR OPTIC BEAM WATTAGE COLOR TEMP + HOUSING DRIVER VOLTAGE. DB Deep Black FL Flood 30º K I 1 IC/Air Tight Housing MF

Bridgelux Gen. 7 V9 HD Array. Product Data Sheet DS402

Bridgelux Gen. 7 V4 HD LED Array. Product Data Sheet DS400

M36 for millimetre-precise profile lengths and structures

PRODUCT FAMILY DATASHEET LEDVANCE HIGH BAY LED

Avenue Metro Suspended

Light is easy to upgrade Siteco DUS LED.

SELECTION

CalcExpress lighting calculation programme

Recessed LED Portfolio

Bridgelux Gen. 7 V6 HD LED Array. Product Data Sheet DS401

Designed to... LED light line system

Indoor Lighting Product Catalogue. We brighten up your life

LUNA OUTSTANDING HIGH MODULARITY

Bridgelux Gen. 7 V6 HD LED Array. Product Data Sheet DS401

XACARA TM A REVOLUTION IN ARCHITECTURAL LIGHTING

[mm] B cout. [mm] [kg] Polar Curve 600x Polar Curve 1200x Polar Curve 1500x

LED LINE FIX LUGA 2016

GUIDE FOR OFFICE LIGHTING OPTICS

16w 16w 15.5 w. Fast Payback: Five Year Guarantee. 1 yr 1mth. 3 yrs 2 mths. 2 yrs

BA- Lighting AS FDV BA412-DL98B-CCT-8-18WD

LuxSpace Accent CrispWhite Experience intense whites and rich colors

Omnidirectional Miniature Lamp Specifications

Luminaire. CANOPY: Spun aluminum canopy with silver finish. Available in flat or round.

SubstiTUBE Basic. Product family datasheet. LED tubes for electromagnetic control gears

Technical Application Guide for UP-SHINE LED Downlight

1x lm/ft - Maximum K

Technical Information

LED LINE FIX SMD GEN. 2

PENDANT INDIRECT. Project. Type. Notes. Lumen/ft up: 1535 lm/ft Total Lumens: 6000 lm (for 4ft) Input Watts: 50.3 W (12.6W/ft) Efficacy: 119 lm/w

Installation Easy Quick Cost-effective. 2 3L-Click

highlights 2017 lighting solutions

14 XAL NEW PROFILES NEW PROFILES. Architectural lighting profile system

WALL HI-OUTPUT. Project. Type. Notes

StyliD Fresh Food Bring your food produce to life

LuxSpace. retail lighting. Product guide. Hidden beauty. with style

PRODUCT FAMILY DATASHEET OSRAM DULUX D LED EM

PRODUCT FAMILY DATASHEET LEDVANCE HIGH BAY LED

WHY CHOOSE SUPACELL LED LIGHTING? * See website for details

Light is impressive Siteco Vega The designer range of LED luminaires for professional office lighting.

HIGH PERFORMANCE RECESSED Collection

PRODUCT GUIDE A portfolio of industry leading solutions that are changing the way we look at light.

PENDANT MOUNT - INDIRECT

Electrical Illumination and Design

Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV

CEILING HI-OUTPUT. Project. Type. Notes

Bridgelux Vesta Series Dim-To-Warm 9mm Array. Product Data Sheet DS150

Cree XLamp LED Wall Sconce Reference Design

Bring the Long Life Light Source to the Real Life: LED Lamp. Welcome. OSRAM Prosperity Co., Ltd. Tel : Tel :

ID LUMINAIRE SERIES. Ontero Intara Pendiro.

LightPro User Guide <Virtual Environment> 6.0

LED LINEAR LIGHTING SHOWROOM BLUEVIEW ELEC-OPTIC TECH CO.,LTD

Sculpt Accent. Adjustable Mini Accents

Operating ambient temperature (Performance + & Performance) Power factor (Performance + & Performance) >0.9 SYSTEM PERFORMANCE LEVELS

Line Lite International BV 7W Dimmable Downlight Sharp

PENDANT INDIRECT. Project. Type. Notes

SubstiTUBE Basic. Product family datasheet. Tubular LED lamps

Transcription:

Z10 Zoom

Minimalist Look and maximised Utility The art of omission continues to play an increasingly important role in today s architecture. Products that can be seamlessly integrated into existing elements will facilitate this type of minimalism in the future. offers lighting designers more freedom to design since the LED module from WILA can follow the ceiling elements in many different ways both across as well as lengthways. Considering different dimensions and functions of a room, the luminaire will at any point provide the desired lighting level (740-2260 Llm). 15 x 15 mm 15 x 24 mm 1 WILA

Light Technique can be integrated into ceilings by replacing selected cross bars in such a way that interiors are optimally illuminated according to their function and form. The combination of individual light modules provides perfect orientation in passageways. In large spaces serving as day/recreation rooms in different lengths provide pleasant general illumination. Here Micro Prisms provide glare-free and uniform distribution of light. 300 300 3.6 m Planning Example Room height: 2.80 m Maintenance factor: 0.80 Reflectances: 70/50/20% Em: 312lx u0: 0.75 Spec. connected load: 7,9W/m² 0.5 0.0 0.0 0.5 5.4 m Railway Station Letmathe, Cafe Bahnsteig 42 Architecture: Manfred Kissing, Iserlohn Lighting Design: WILA Lichttechnik GmbH Nassau University Medical Center - East Meadow, New York - Specifiers: Fletcher-Thompson, Inc. Project solution in rectangular and square shapes on request 3 WILA

Installation Technique Easy Installation in Ceiling Systems For individual solutions tuned to the purpose of the room can be inserted in the ceiling grid either individually, as a continuous line-up or arranged in a cross design. As a rule, not all one-piece mounting bars can be replaced by linear light modules. This means opens up new, unobtrusive design perspectives. Project solution for rectangular and square forms Examples for array of Possible Positions for One-piece main runner bar - cannot be replaced by One-piece main runner bar, not replaceable Replaceable cross bar 600/625 mm Replaceable cross bar 1200/1250 mm 4 5 WILA

Project ON OFF Nassau University Medical Center - East Meadow, New York Specifiers: Fletcher-Thompson, Inc. Perfect Integration Functional passageways such as waiting rooms, corridors or conference rooms are often fitted with grid ceilings. This is precisely the standard that uses as a basis for an entirely integral lighting solution: Both mounting bar and lighting element at the same time. 6 7 WILA

Project Bank of the West - San Francisco, CA Specifiers: Gensler / Birkenstock Lighting Design offers a minimalist, high-performing solution for our retail design needs. The seamless integration into the ceiling system creates a clean and modern aesthetic that enhances the overall design, creating a balance between light and space. Prasert Wiwatykhan, Designer at Gensler 8 9 WILA

Project AARP Renovation Project - Washington, D.C. Specifiers: OPX Design Cunsultancy There were many reasons why we chose to use, and probably none more than acoustics. This client was very sensitive to sound transfer between enclosed spaces, and the was a big part of our solution. Having the fixture integrated into the ceiling grid system allows additional ceiling tiles to be installed to absorb sound, and also to limit sound transfer through the light fixture, which is not the case with a traditional 2x2 fixture. Erik Wyche, OPX Design Consultancy 10 11 WILA

Heat Management Heat management is the key to more efficiency. is designed to dissipate the heat it generates in no time. A benefit of becomes evident when looking at the data centre. Here ceiling elements can simply be removed for maintenance jobs in the ceiling void since there are no luminaires attached to them. Top Heat Sink Convection Ceiling Panel Bottom Heat Sink LED Mid Atlantic Region - Data Center Facility Specifiers: Facility Management & Illuminations Inc. Patent No. 8,177,385. Additional patents are pending. 12 13 WILA

LED Recessed Products Luminaire LED Recessed Luminaire TB3102002-30-40 TB3102012-30-40 RD W L IP44 wila471-40 Micro Prism, 4000 K, Light distribution direct, for ceiling grid 600 mm, 15 mm visual T-grids W Llm Llm/W γ 65 UGR RD mm Luminaire Driver cd/m 2 standard-dv DALI-DV CRI 80 LxWxH 1200x15x15 mm 34 W 1486 44 --- 26 51 TB3102012-30-40 83751 83751-DD-DV LxWxH 600x15x15 mm 17 W 743 44 --- 26 51 TB3102002-30-40 83751 83751-DD-DV Use index -40 (4000 K) or -30 (3000 K), photometric data in the products on www.wila.com LED Recessed Luminaire TB3102001-30-40 TB3102011-30-40 RD W L IP44 wila472-40 Micro Prism, 4000 K, Light distribution direct, for ceiling grid 600 mm, 24 mm visual T-grids W Llm Llm/W γ 65 UGR RD mm Luminaire Driver cd/m 2 standard-dv DALI-DV CRI 80 LxWxH 1200x24x15 mm 34 W 1978 58 --- 25 51 TB3102011-30-40 83751 83751-DD-DV LxWxH 600x24x15 mm 17 W 989 58 --- 25 51 TB3102001-30-40 83751 83751-DD-DV Use index -40 (4000 K) or -30 (3000 K), photometric data in the products on www.wila.com LED Deckeneinbauleuchte Recessed Luminaire TB3102101-30-40 TB3102111-30-40 RD W L IP44 wila474-40 Micro Prism, 4000 K, Light distribution direct, for ceiling grid 625 mm, 24 mm visual T-grids W Llm Llm/W γ 65 UGR RD mm Luminaire Driver cd/m 2 standard-dv DALI-DV CRI 80 LxWxH 1250x15x15 mm 34 W 1486 44 --- 26 51 TB3102112-30-40 83751 83751-DD-DV LxWxH 625x15x15 mm 17 W 743 44 --- 26 51 TB3102102-30-40 83751 83751-DD-DV Use index -40 (4000 K) or -30 (3000 K), photometric data in the products on www.wila.com LED Deckeneinbauleuchte Recessed Luminaire TB3102102-30-40 TB3102112-30-40 RD W L IP44 wila473-40 Micro Prism, 4000 K, Light distribution direct, for ceiling grid 625 mm, 15 mm visual T-grids W Llm Llm/W γ 65 UGR RD mm Luminaire Driver cd/m 2 standard-dv DALI-DV CRI 80 LxWxH 1200x24x15 mm 34 W 1978 58 --- 25 51 TB3102011-30-40 83751 83751-DD-DV LxWxH 600x24x15 mm 17 W 989 58 --- 25 51 TB3102001-30-40 83751 83751-DD-DV Equity Use index Office -40 (4000 - Boston, K) or -30 MA (3000 K), photometric data in the products on www.wila.com Specifiers: Dyer Brown Architects Equity Office - Boston, MA Specifiers: Dyer Brown Architects 14 15 WILA

Knowledge Definitions / Details Luminaire Luminous Flux Llm The luminaire luminous flux (Llm) defines the usable light of the luminaire and is the decisive value in lighting design. As opposed to the lamp luminous flux (lm), the luminaire luminous flux (Llm) accounts for losses due to the design of the luminaire and thermal losses associated with LED systems. WILA defines only the Llm value for all LED lamps at operating temperature. This value can be found both in data sheets and in the relevant EULUMDAT file. System Efficiency Llm/W System efficiency defines the ratio of luminaire luminous flux (Llm) to power input (W). Efficiency losses due to gear boxes have already been taken into account by WILA in the Llm/W value. System Photometric Data For a qualified comparison between LED luminaires and luminaires with compact fluorescent lamps, it is important to ensure first that the products to be compared share approximately the same photometric data. Sample calculation: LED luminous flux 2000 lm (100%) - system losses (light output ratio) = luminaire luminous flux 1720 Llm LED efficiency 2000 lm : 20 W = 100 lm/w System efficiency 1720 Llm : 22 W (20 W LED module + 2 W driver) = 78 Llm/W Heat sink LED module 2000 lm / 100 lm/w Light directing system alphabet spectra Luminaire luminous flux 1720 Llm System efficiency 78 Llm/W Cut-off Angle The cut-off angle of luminaires is defined as the angle between the horizontal plane and the point from which the light source is not yet directly visible. The increased visual comfort offered by shielded light sources is clearly perceivable. The Downlights of the αbet zono family of products, for example, is due to their very good cut-off angle of 30. Half-peak Divergence Angle α For accent lighting, the half-peak divergence angle α is given rather than the beam spread angle. The half-peak divergence angle is defined as the angle of the rotationally symmetrical luminous intensity distribution at which the luminous intensity equals half of its maximum value. The half-peak divergence angle is given as a full angle: super spot < 10, spot 10-20, flood 21-45, wide flood 46-55 and very wide flood > 55 Beam Spread Angle ɣ The beam spread angle ɣ is defined as the angle at which the luminous intensity drops to 1% of the maximum value lmax. It is measured from the vertical (see luminous intensity distribution curve) and is an important measurement for glare reduction. Limits of the average luminance of screens with a beam angle of > 65 Screen high Screen average illuminance 200 cd/m 2 illuminance 200 cd/m 2 Positive polarity and usual requirements 1) 3000 cd/m 2 1500 cd/m 2 Negative polarity and high requirements 2) 1500 cd/m 2 1000 cd/m 2 1) Example Office programme, dark text on bright background 2) Example CAD programme, bright lines on dark background Light Output Ratio of a luminaire ƞlb The light output ratio of a luminaire is the ratio of the luminous flux of the luminaire to the luminous flux of the light source. It includes the optical, light directing properties of the luminaire and the thermal properties of the light source. A special feature of office luminaires with T16 lamps is that the maximum light flux of the T16 lamp is achieved at 33-37 C. The value measured and stated in the catalogues is much lower at 25 C. For example, OSRAM gives a correction factor (F) for this of 0.9 and, with FQ, of 0.88. You can use the formula φmax =φ/f to calculate the maximum light flux. Important: with our luminaires, you can use the list light flux at 25 C because we have already included the additional benefit in ƞlb. UGR The UGR method takes into account the layout of the luminaires in the room and evaluates the glare produced by the entire lighting system for a specific observer s position. WILA provides UGR values where the observer s position is parallel to the longitudinal axis of the luminaire and the lamp/luminaire axis is parallel to the longer side of the room. The UGR method is implemented on the basis of simple tables. A low UGR value indicates that glare is negligible or non-existent. Suitability examples of maximum UGR values: 16 for drafting rooms, 19 for offices and control rooms, 22 for precision industrial tasks, 25 for light industrial tasks and 28 for heavy industrial tasks. Luminous Intensity Distribution In order to give a clearer overview, the luminous intensity distribution curves have been divided into groups. Shown are the planes from 0 to 180 (red line) and from 90 to 270 (blue line). The 0 plane is on the right. Beam Chart For accent luminaires beam charts are shown. The angle of the spread out beam corresponds to the half-peak divergence angle of the luminous intensity. Diameter and average illuminance Em [lx] can be read from the chart for each corresponding height. Planning Grid Room The chart is intended as a means of calculating the approximate illuminance required for ceiling grids in rooms and corridors. For the 600 grid, the illuminances should be multiplied by a factor of 0.9. Colour Rendering Index CRI The colour rendering index CRI documents the quality of the colour rendering of light sources on the basis of eight defined test colours (R1-R8). Colour temperature K 2700K super warm white 3000K warm white 4000K neutral white MacAdams ellipses The deviation from the target chromaticity coordinate, is given in the SDCM (Standard Deviation of Colour Matching). Deviations of < 2 SDCM are classified as being imperceptible to the eye. Index -DV = loop-in/loop-out function -DD = dimmable, DALI -DD-DV = DALI dimmable with loop-in/loop-out function -PT = integrated luminaire controller with Daylight control and Presence detector Abbreviations/Dimensions OH = overhang, max. length of luminaire from the centre of reflector W, W1 = width information D = diameter CO = ceiling, wall or floor cut-out for recessed luminaires CO W = width of ceiling or wall cut-out for recessed luminaires CO L = length of ceiling or wall cut-out for recessed luminaires RD = required installation depth for recessed luminaires under consideration of F conditions H, H1= height information K = colour temperature in Kelvin L, L1 = length information Q = reflector size, square R = reflector size, round CRI = colour rendering index W = electrical power α = half-peak divergence angle ɣ = beam spread angle Reflector sizes With the reflector size Q or R results the following ceiling cut-out CO (in mm) of the luminaire: Q 01 03 05 08 10 15 18 21 CO 32x32 51x51 68x68 95x95 120x120 170x170 200x200 235x235 R 01 03 05 08 10 13 15 18 23 27 37 CO 32 51 68 95 120 140 165 195 240 280 380 Quick Code The Quick Link takes you from the printed catalogue to your desired project on the WILA website right away. Simply enter the black-highlighted code into the search box of the WILA homepage. You will then be directed to the same product group and just have to select the desired control gears, e.g. DALI at the end of the column. One click will then take you to the product data sheet. Needless to say, you can also enter the complete article number in the search box on the WILA website to access the desired product. 1. Find the code for this Quick Link above the product chart Planning Data This brochure gives a concise overview of the current WILA product ranges. All necessary data and specifications for planning and product ordering as well as article numbers can be found up to date on our homepage www.wila.com Information and Tolerance Many luminaires are protected by comprehensive design registrations, patents and trademark protections. We reserve the right to change material, design and programme without notice. Statements are not warranted characteristics. Photometric data is subject to a tolerance of +/- 10%. Optical attachments also impact IP values. Pictures and drawings are for illustrative purposes only. Our terms and conditions of sale and delivery apply. F Mark All WILA luminaires are suitable for use in or on ceilings of normal flammability and have so far been labelled with the F marking. With the publication of the EN 60598 standard, date of issue 09/2009, this marking is no longer applicable. After the end of the transitional phase on 12.04.2012, all luminaires without labelling are suitable for use in or on a ceiling of normal flammability. Luminaires that do not fulfil the thermal requirements are marked with a new pictogram. Information about Maintenance The illuminance for a room/property must satisfy the published values according to EN 12464-1 over the entire period of usage; this corresponds to the maintenance value. The electrical planner is responsible for determining the maintenance factor dependent upon the lighting system and the spatial conditions used and ensuring this with a maintenance schedule. Further details about maintenance can be found in the Knowledge section on our homepage www.wila.com 2. Enter the code. For alternative product versions replace the index in the footer line below the printed chart, e.g. wila583-40 by wila583-30 for 3000 K 3. Select control gear ( Details ) and you will be directed to the product data sheet 16

WILA Lichttechnik GmbH Postfach 26 11 D 58596 Iserlohn Vödeweg 9-11 D 58638 Iserlohn T +49 2371 823 0 F +49 2371 823 200 wila@wila.com www.wila.com Member of the Nordeon Group WILA Lighting Limited 8-10 The Quadrangle Grove Technology Park Wantage Oxfordshire OX12 9FA T +44 1235 773 500 F +44 1235 773 533 wila@wila.co.uk Distribution of system in the various countries is handled exclusively by WILA distribution partners or other local partners. Please contact WILA s export department for further details by calling 0049 2371 823 0. 0716