Explanation of options and accessories for the GP102 and GP102 -PAV

Similar documents
Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication

Standalone High Accuracy Transformer Analysis. Basic 0.02dB with class leading high frequency performance. RS232, USB and LAN as standard

Bench LCR Meter Model 891

Digital Sampling Power Meter. Digital Power Meter and Power Analyzer WT210/WT230 WT1600 WT2010/WT2030 PZ4000

Fluke Norma 4000/5000

Green LED (right of 'D' type connector)

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

Fluke Norma 4000/5000

Measurement of the equivalent circuit of quartz crystals

Programmable AC Power Source Model 9801

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

Agilent 34405A Multimeter

DECLARATION OF CONFORMITY

AC/DC Power Sources ACS Series

Multifunction Calibrator - Model 8080

LCR METER Series. A New Series of LCR Meters to Meet Your Applications. From Production Lines to Research and Development

Current Clamp. 210

Npaq Series Drive Racks

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

True RMS Bench Multimeter 5492B

AC/DC Power Sources ACS Series

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

IMPEDANCE ANALYZER IM3570

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

INSTRUCTIONS FOR USE

Single Device Solution for High Speed Testing and Frequency Sweeping IMPEDANCE ANALYZER IM3570

Network Analyzer for Low-, Medium- and High-Voltage Networks

Keysight 34401A Multimeter

Multiple Instrument Station Module

Model 7000 Low Noise Differential Preamplifier

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet

N. TEST TEST DESCRIPTION

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Primary-standard resistance thermometry bridge Model CTR9000

USB250: 3 Channel Portable Instrument connected to USB 2.0 or USB 1.1

Model LIA100. Lock-in Amplifier

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CATALOG including...

Fluke 1750 Three-Phase Power Recorder

MEASURING INSTRUMENT. Capacitance Leakage Current / IR Meter Model IR Features.

True RMS Bench Multimeter 5492B

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

FREQUENCY RESPONSE ANALYZERS

Schlöder GmbH - EMC Test and Measurement Systems Model #

Automotive Scope/GMM/OBD II Code Reader

A New Series of LCR Meters to Meet Your Applications

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

19998-WK 8pp 3255/3260 6/9/00 11:57 am Page B Precision Magnetics Analyzer 3255B Inductance Analyzer 3265B 25A Bias Unit

Experiment 1: Instrument Familiarization (8/28/06)

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

OPERATING AND MAINTENANCE MANUAL

Solutions In Calibration TRANSMILLE PRODUCT GUIDE 2015/16 PROVIDING SOLUTIONS IN CALIBRATION WORLDWIDE. www. transmillecalibration.

Table of Contents. Table of Contents Instrumentation Multimeter. Lucas Nülle GmbH Page 1/14

Experiment 1: Instrument Familiarization

PM6000. Voltech. Power Analyzer

Model 4402B. Ultra-Pure Sinewave Oscillator 1Hz to 110kHz Typical Distortion of % Serial No. Operating Manual

Agilent 4072A Advanced Parametric Test System with Agilent SPECS

PSM3750 START UP GUIDE

Migrating 4195A to E5061B LF-RF Network Analyzer. April 2010 Agilent Technologies

MEASURING INSTRUMENTS AND TESTERS

Application Note. Applying DC Bias to Inductors with the 1910 Inductance Analyzer

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Wide-band Models from DC to 100 MHz

LCR Meter. Product Specification

Voltech PM3000ACE UNIVERSAL POWER ANALYZER

Electricity. Coil in the AC circuit /11. Electrodynamics. What you need:

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

2026Q CDMA/GSM Interferer MultiSource Generator

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

HANDYSCOPE MODEL HS4 4 Channel Portable Instrument Connected to USB 2.0 and USB 1.1

DIGITAL HiTESTER 3237, 3238, 3239

APPLICATIONS. Oscilloscope Display. Harmonic Measurement. High Precision Measurement up to 0.1% Power Supplies Tests Motor Tests

PPA500 Series PPA1500 Series


Magnetic-Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

PPA500 Series PPA1500 Series

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

N. TEST TEST DESCRIPTION

Testing Power Factor Correction Circuits For Stability

Component Test. All Test Equipment in this category can be linked to PC. Comparison Function. Graphic Scan Function Bin Sorting Function

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

ECE 2274 Lab 2 (Network Theorems)

PQube 3 Specifications

Network Analyzer for Low-, Medium- and High-Voltage Networks

Agilent Technologies 3000 Series Oscilloscopes

Opamp stability using non-invasive methods

Manage Electrode Reaction Resistance, Electrolyte Resistance, and Welding Resistance

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

3B SERIES AC & DC LOADS

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

V1.3. TBLC08 50mH AC-LISN TBLC08

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

DS1000B Series Digital Oscilloscopes

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Transcription:

Powertek Power Instrumentation, LCR analysis Gain-Phase / waveform analysis / PAV Shunts, current transformers 148 Beecham Road Reading Berkshire RG30 2RE England Tel: 0118 950 2468 Fax: (+44) 0118 958 8360 Info@powertekuk.com VAT Reg: GB 724 3670 40 18 May 2004 Explanation of options and accessories for the GP102 and GP102 -PAV GP102 Standard upright free standing GP102. See GP102 brochure for picture. Includes 2 x input probes, 1 x BNC-crocodile output cable, RS232 cable, power cord, user manual, certificate of conformance and test certificates. GP102 - PAV Phase Angle Voltmeter variant of the GP102 for testing avionic and positional control systems. Phase and amplitude accuracy is optimized in the 10Hz-100kHz range. See GP102 brochure for picture. Includes 2 x input probes, 1 x BNC-crocodile output cable, RS232 cable, power cord, user manual, certificate of conformance and test certificates. GP102-IO Upright free standing GP102, RS232 interface only, no front panel keys and display. Includes software, 2 x input probes, 1 x BNC-crocodile output cable, RS232 cable, power cord, user manual, certificate of conformance and test certificates. GP102R-IO System GP102 in 19 rack, 2U format. RS232 Interface only, no front panel keys and display. Includes software, 2 x input probes, 1 x BNC-crocodile output cable, RS232 cable, power cord, user manual, certificate of conformance and test certificates. GP102R System GP102 in 19 rack, 2U format. Includes RS232 interface, front panel controls and display. Includes 2 x input probes, 1 x BNC-crocodile output cable, RS232 cable, power cord, user manual, certificate of conformance and test certificates. Option IEEE The IEEE-488 is a parallel, bi-directional (talk and listen) interface, using the same ASCII command set as the GP102 RS232 interface. IEEE-488 can be fitted to any of the GP102 models; order codes are GP102/IEEE, GP102-IO/IEEE, GP102R-IO/IEEE or GP102R/IEEE. 1

Option-01P Passive LCR head Allows convenient measurement of complex impedance parameters like L, C, R, Z, Resr, Rdc, Q, D, Tan delta and phase angle. Measurement range is 10Hz to 500kHz, Maximum R = 100kohm, Minimum C = 50pF and Minimum L=500nH. Supplied with Generator, CH1 and CH2 BNC connections along with black and red Kelvin test clips. Connects direct to the GP102 front panel BNC connectors. Option-01A Active LCR head Allows GP102 to measure complex impedance parameters like L, C, R, Z, Resr, Rdc, Q, D, Tan delta and phase angle. Measurement range is 10Hz to 2MHz, Maximum R = 100Mohm, Minimum C = 10pF and Minimum L=100nH. Supplied with Generator, CH1, CH2 and extension port connections along with black and red Kelvin test clips. This option connects direct to the GP102 front panel BNC connectors, a control cable connects to the GP102 rear panel extension port. Option-02A UK power meter adaptor The option 02A allows the GP102 to measure ±watts, VA, true power factor, amps rms, amps pk, crest factors, dc component, frequency Hz, Phase angle (cos phi), fundamentals and harmonics. The option 02A adaptor is external to the GP102 containing an internal shunt, power socket, line cord and 2 isolated BNC output connections. Available in 15A and 5A versions e.g. option 02A-15A or option 02A-5A. Option-02B Schuko power meter adaptor German, Danish, French, Spanish version of the above Option-02C USA power meter adaptor United States version of the above Option-02E 30A clamp current probe Calibrated wideband 30Arms Hall Effect clamp probe, frequency range DC-100kHz. This option allows the GP102 to measure power to 15kW. The option 02E probe also allows the GP102 to measure VA, power factor, amps rms, crest factors, dc component, frequency Hz, Phase angle (cos phi), fundamentals and current harmonics. Clamp design allows fast installation. Option-02F wideband precision current shunt. 0.1% accuracy, rated 5 watts - Available in 0.02R, 0.05R, 0.1R and 1.0R ohmic values. These precision wideband current shunts allow current measurement over the frequency range DC- 500KHz. Using this option the GP102 can measure real power and complex impedance parameters like Z, Inductance, XL, Capacitance, Xc, tan delta, Q and phase angle. This option also allows the GP102 to measure VA, power factor, amps rms, current crest factors, dc current component, frequency Hz, phase angle (cos phi), fundamentals and current harmonics. Example part number:- Option-02F-0.02 = 0.02R wideband shunt. 2

Option 03A Injection Transformer Injection transformer, ratio 6.3:1 pri-sec, intended to isolate the GP102 signal generator when checking switch mode power supply control loops. Bandwidth is 25Hz to 500kHz, isolation is >1kV. Incorporates BNC input cable and small size crocodile output connections. Option 04A LPA01 Amplifier Intended to boost the GP102 generator output for a variety of applications. Operates over the frequency range Dc-1MHz with a 20Vpk-pk 1A continuous output. The input impedance is 10k ohm with isolated BNC input and output connectors. Has switchable gain settings of x1, x4 or x 10. Option 04C Isolation amplifier The option 04C isolates the GP102 signal generator from the device under test and is used where the required test frequency is low, preventing the use of transformer based isolation. Typical applications include feedback control loops used in SMPS power factor correction circuits, where voltages are at power line potential. Here the required injection signal is likely at low frequencies from 0.1Hz to 20Hz. The unit has a working isolation of 850V from input to output and is supplied with its own ac power adapter, BNC input connection and crocodile clip output connections. Option-05A impedance adaptor Converts the GP102 generator 50 ohm output impedance to 75 ohm (BNC terminals) and 600 ohm (using 4mm output terminals) Option 06A software utility This simple Windows based RS232 utility, allows GP102 sweep measurements to be saved to a text file. This text file can be easily opened using Excel. An Excel macro is provided to allow easy importation and conversion to a Bode Plot graph. When using the option 06A, the GP102 would be operated manually to capture a set of sweep data, the 06A software is then used to transfer measurement from the GP102 to PC. Option 06B/RS232 LabView Driver This software option is a LabView driver allowing owners of the NI LabView software to use and edit the option 06B driver. The driver allows GP102 measurements to be saved to a text file, single shot and continuous acquisition of measurement data, transmission of set up commands along with a display window to monitor measurements. Data files created can be opened using Excel, data can then be imported into a spreadsheet. Option 06B/IEEE-488 LabView Driver This software option is a LabView driver allowing owners of the NI LabView software to use and edit the option 06B driver. The driver allows GP102 measurements to be saved to a text file, single shot and continuous acquisition of measurement data, transmission of set up commands along with a display window to monitor measurements. Data files created can be opened using Excel, data can then be imported into a spreadsheet. 3

Option 06C/RS232 software This software option is a LabView based program (.exe) allowing control of the GP102. The user is not required to have the NI LabView software but is required to have the LabView runtime Engine Installed. The program allows GP102 measurements to be saved to a text file, single shot and continuous acquisition of measurement data, transmission of set up commands along with a measurement display window. Data files created can be opened using Excel, data can then be imported into a spreadsheet. Option 06C/EL/RS232 software This software option allows control of the GP102 / LPA400 for Electro Luminescent Lamp (EL Lamp) testing applications. The program allows GP102 LCRZ / electrical power measurements to be saved in a text file using single shot or timed acquisition of measurement data. Control of an external lightmeter is possible (specify when ordering), allowing simultaneous measurement of LCRZ / electrical power / light meter measurement data. Transmission of GP102 set up commands is automatic, front panel control of the GP102/LPA400 output voltage and frequency is possible. Incoming measurements can be monitored in a display window. Data files created can be opened using any spreadsheet. Option 06D EL Amplitude step software Perform amplitude sweep over 15 steps user defined steps Option 06E EL Amplitude step software including light meter control Perform amplitude sweep over 15 steps user defined steps including lightmeter data Option 06F Bode plotting software for power supply loop testing This software option allows the user to easily plot the gain phase data available from the GP102, used typically in power supply control loop testing. A colour plot of Gain and Phase is easily achieved, GP102 settings can be saved. Bode plots and sweep data can be stored. The user has control of input coupling, amplitude, sweep start, sweep stop along with the number of sweep points Option-10A Soft carry bag for GP102 & standard cable set Option-10B Hard carry case for GP102 upright & standard cable set Option-10B-R Hard carry case for GP102R & standard cable set Option TAF01-U The TAF01-U switching matrix allows automated or semi-automated testing of LVDTs and resolvers, used with the Powertek GP102 Phase Angle Voltmeter (GPAV). The TAF01-U allows the user to make a one time connection to the LVDT / Resolver windings, all measurement connections to the LVDT are routed through the TAF01-U to the GP102 measuring inputs, meaning reconnection is not necessary for each LVDT tests. 4

The TAF01-U is the unbuffered version of the TAF01, meaning it can operate to 50Vrms. It is a switching matrix, external to the GP102 PAV, allowing the GP102 PAV generator, CH1 reference and CH2 signal inputs to be routed to any of the three LVDT windings. Control of the TAF01-U is possible from the GP102 front panel or using the IEEE-488 or RS232 ports. The TAF01-U is connected via 3 bnc cables to GP102, a control cable connects from the TAF01-U to the GP102 extension port. The TAF01-U also allows standard transformer tests, typically turns ratio, Z, Lp, Ls, Q, Cp, Cs, Tandelta, Rdc, Resr. Up to 3 transformer windings may be connected and tested. Option-LVDT Fx The LVDT test fixture allows easy connection from the LVDT to the TAF01-U matrix. Consisting of a PCB, fitted with quick release terminals, allowing the LVDT transformer to be conveniently connected to the TAF01 connection nodes. This plug-in fixture PCB allows user configurable connection from the relevant transformer windings to the TAF01 connection nodes. Other accessories and spares for the GP102 Gain Phase Analyser GP102 user manual with programming guide GP102 laminated quick reference sheets Application notes for Power supply control loop testing Isoprobe - 500V cat II isolated BNC to safety probe with ground clip 4mm (banana) to 4mm (banana) safety test lead set comprising of 2 red and 2 black cables Large jaw, safety type crocodile clip. Available in red and black Isolated BNC to isolated BNC cable GP102 BNC to crocodile generator output cable Null modem RS232 cable 9 pin D type to 9 pin D type Non-isolated BNC - 4mm adapter (banana). Has screw pillars Isolated BNC - 4mm safety socket (banana) adapter Software utilities CD 5