Kongsberg Mesotech Ltd.

Similar documents
Serial Communications RS232, RS485, RS422

ROM/UDF CPU I/O I/O I/O RAM

Summary of Well Known Interface Standards

RS-232 Electrical Specifications and a Typical Connection

Dual Protocol Transceivers Ease the Design of Industrial Interfaces

SMARTALPHA RF TRANSCEIVER

Transmission Line Drivers and Receivers for TIA/EIA Standards RS-422 and RS-423

The Practical Limits of RS-485

FAILSAFE Biasing of Differential Buses

Proper Termination of Digital Incremental Encoder Signals

SV613 USB Interface Wireless Module SV613

Appendix C RS-485 Network

Introduction. Protocol Definitions. The RS-485 Standard. APPLICATION NOTE 3884 How Far and How Fast Can You Go with RS-485?

3 Definitions, symbols, abbreviations, and conventions

Transmission Line Drivers and Receivers for TIA EIA Standards RS-422 and RS-423

Product Specification for model TT Transducer Tester Rev. B

RS-422/485 Application Note

Low Power with Long Range RF Module DATASHEET Description

4 x 10 bit Free Run A/D 4 x Hi Comparator 4 x Low Comparator IRQ on Compare MX839. C-BUS Interface & Control Logic

USB Port Medium Power Wireless Module SV653

EECE494: Computer Bus and SoC Interfacing. Serial Communication: RS-232. Dr. Charles Kim Electrical and Computer Engineering Howard University

Embedded Radio Data Transceiver SV611

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

Modbus communication module for TCX2: AEX-MOD

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

Catalog

RECOMMENDATION ITU-R BT *

RF RECEIVER DECODER RDF1. Features Complete FM Receiver and Decoder. Applications

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

G3P-R232. User Manual. Release. 2.06

AT-XTR-7020A-4. Multi-Channel Micro Embedded Transceiver Module. Features. Typical Applications

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

ROTRONIC HygroClip Digital Input / Output

Concept of Serial Communication

EE 314 Spring 2003 Microprocessor Systems

RECOMMENDATION ITU-R BT.1302 *

INTEGRATED CIRCUITS. AN109 Microprocessor-compatible DACs Dec

Quad 12-Bit Digital-to-Analog Converter (Serial Interface)

2320 cousteau court

Catalog

745 Transformer Protection System Communications Guide

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

Basic Communications Theory Chapter 2

Technical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

Programmable RS-232/RS-485 Transceiver

Local Asynchronous Communication. By S.Senthilmurugan Asst.Professor/ICE SRM University. Chennai.

Installation procedure Ground loop reader: LBS type R12 / RS232 type 5C

C191HM POWERMETER AND HARMONIC MANAGER COMMUNICATIONS REFERENCE GUIDE

CS601 Data Communication Solved Objective For Midterm Exam Preparation

Design Implementation Description for the Digital Frequency Oscillator

Industrial Interface Standards Overview: RS-485/422, PROFIBUS, RS-232, CAN, LIN, I2C, IO-Link. October 2018 Transceiver Interface Products

6. has units of bits/second. a. Throughput b. Propagation speed c. Propagation time d. (b)or(c)

S O P H I S T I C A T E D A U T O M A T I O N

Appendix C. LW400-09A Digital Output Option

COMMUNICATION MODBUS PROTOCOL MFD44 NEMO-D4Le

The ST7588T is a driver & controller LSI for graphic dot-matrix liquid crystal display systems. It contains 132 segment and 80

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

ICS3.5 Software Manual Command Refarence

Chapter 12: Digital Modulation and Modems

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Back to. Communication Products Group. Technical Notes. Local/Remote Control, 9300 Series

Stensat Transmitter Module

Industrial Interface Standards Overview:

RF1212 RF1212 Ultra-low Power ISM Transceiver Module V2.0

M7 Series Modems for SCADA Applications

DRF4463D20 Medium Power ISM RF Transceiver Module V1.21

Ultrasonic Multiplexer OPMUX v12.0

Product Information Using the SENT Communications Output Protocol with A1341 and A1343 Devices

SP483E. Enhanced Low EMI Half-Duplex RS-485 Transceiver

This is by far the most ideal method, but poses some logistical problems:

SmartRadio Transmitter / Receiver

Complete information on monitor and control software is contained in the following sections.

Programmable RS-232/RS-485 Transceiver

Data transmission - Transmission modes

SRT PAGING & DATA RECEIVER MANUAL

CS601-Data Communication Latest Solved Mcqs from Midterm Papers

CPSC Network Programming. How do computers really communicate?

Low Power Half-Duplex RS-485 Transceivers

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

DS1867 Dual Digital Potentiometer with EEPROM

TSA 6000 System Features Summary

Catalog

DS1803 Addressable Dual Digital Potentiometer

Arduino Arduino RF Shield. Zulu 2km Radio Link.

KAPPA M. Radio Modem Module. Features. Applications

RF ISM Transparent Transceiver Module V4.0

10.9. Serial communication parameters Motor parameters Paramters handling Status monitor

The Practical Limits of RS-485

Orbis true absolute rotary encoder

LCC-10 Product manual

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Roland Kammerer. 13. October 2010

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

E31-TTL-500 Datasheet V Feature E31-TTL-500

Application Note ANI-22 Enhanced Receiver Failsafe Implementation In Dual Protocol SP339 and XR34350 Serial Transceivers

WWVB Receiver/Decoder With Serial BCD or ASCII Interface DESCRIPTION FEATURES APPLICATIONS

Analog I/O. ECE 153B Sensor & Peripheral Interface Design Winter 2016

Home Automation, Inc. Omnistat2. RC-1000 and RC-2000 Communicating Thermostat. Serial Protocol Description

isma-b-w0202 Modbus User Manual GC5 Sp. z o.o. Poland, Warsaw

Transcription:

Kongsberg Mesotech Ltd. Doc. No. : 974-00007904 Title : Digital Telemetry Notes elease : Version 1.4 Date : 2010-04-30 1. PUPOSE This document briefly describes the digital telemetry standards, formats and protocols implemented in our MS1000-compatible line of digital telemetry single beam sonar system products. 2. ACONYMS AND ABBEVIATIONS The following abbreviations and acronyms are freely used in this document: KML Kongsberg Mesotech Ltd. TIA Telecommunications Industry Association EIA Electronics Industry Association ADC Analog to Digital Converter bps bits per second (baud rate) lsb least significant BIT msb most significant BIT. H suffix indicating a Hexadecimal value 2008 Kongsberg Mesotech Ltd. Page 1 of 12

3. SEIAL COMMUNICATION CONCEPTS 3.1 Downlink and Uplink The terms downlink and uplink are used to indicate the direction of data flow on the communications link. The perspective is normally from the viewpoint of a processor or controller. Downlink refers to the data flow away from the processor to a peripheral, and uplink refers to the data flow towards the processor from a peripheral. 3.2 Full-Duplex and Half-Duplex A Full-Duplex serial communications link implements separate, unidirectional, signal paths for the uplink and downlink data flows. This allows for simultaneous uplink and downlink data flows without collision. A Half-Duplex serial communications link implements a single, bi-directional, signal path that is shared between the uplink and downlink data flows. To prevent collisions, a communications protocol is required to determine the data flow direction and the active sender. A communications protocol can also be used to operate a Full-Duplex link in Half- Duplex mode for reasons other than collision control. 4. ASYNCHONOUS SEIAL COMMUNICATION STANDADS Synchronous communication schemes use a clock line between the sender and receiver to identify the individual data bits of the transmission. Asynchronous communication omits this clock line and instead both sender and receiver operate at the same (known) clock rate, and the sender inserts start and stop bits in the transmission to help the receiver detect the individual data bits. KML digital telemetry systems implement two common asynchronous serial data transmission standards: S-232, S-485. S-422 is also available as an option (contact KML for further information). All three of these standards were written by the EIA to allow asynchronous serial communications between peripherals and computers. Note that none of these standards specify the message format of the data bits or the software protocols used between the sender and receiver, rather they specify the Transmit and eceive voltage levels representing the binary states 0 and 1 on the transmission medium. 2008 Kongsberg Mesotech Ltd. Page 2 of 12

4.1 S-232 (TIA/EIA-232-F) The S-232 standard is a complete communications interface standard that specifies the mechanical, electrical and functional requirements for the interface. Electrically it specifies an unbalanced (single-ended), uni-directional, point-to-point interface. Maximum S-232 data rate = 20kbps on a 50ft cable. Higher rates are possible over shorter cables. S-232 driver S-232 receiver TTL in D S-232 telemetry TTL out binary data char 'A' = 41 hex +10V start data stop 0 1 0 0 0 0 0 1 0 1 0V -10V Figure 1: Typical S-232 Application TIA/EIA-232-F Major Electrical Specifications: Driver loaded output voltage (3kΩ) 5.0V Driver open circuit output voltage 25V Driver short circuit current 100mA Driver maximum slew rate 30V/µs Driver output resistance (power off) 300Ω Maximum capacitive load seen by driver 2500pF eceiver maximum input voltage ± 25V eceiver thresholds ± 3V eceiver input resistance 3kΩ to 7kΩ 2008 Kongsberg Mesotech Ltd. Page 3 of 12

4.2 S-422 (TIA/EIA-422-B) The S-422 standard is an electrical standard that specifies a unidirectional single driver, multiple receivers, and a balanced, terminated interface. Termination is located at the receiver end of the cable, and the stub length should be minimized to limit reflections. Maximum data rate = 10Mbps for cable lengths up to 40ft. Maximum cable length = 4000ft for data rates up to 100kbps. S-422 driver S-422 receivers TTL in D T TTL out S-422 telemetry T = Termination 100 ohm binary data char 'A' = 41 hex start data stop 0 1 0 0 0 0 0 1 0 1 4V Figure 2: Typical S-422 Application Major S-422 specifications: Driver loaded output voltage 2.0V Driver open circuit output voltage 10V Driver short circuit current 150mA Driver output impedance 100Ω eceiver common mode range ± 7V (± 10V) eceiver maximum differential input voltage ± 12V eceiver operating differential range ± 200mV to ± 6V eceiver thresholds ± 200mV eceiver input resistance 4kΩ 2008 Kongsberg Mesotech Ltd. Page 4 of 12

4.3 S-485 (TIA/EIA-485-A) The S-485 standard is an electrical standard that specifies multiple balanced drivers, multiple balanced receivers, and a balanced terminated interface. TIA/EIA-485 allows multiple driver/receiver operation in multipoint, party-line configurations and specifies a bidirectional, half-duplex, multipoint interface. Maximum transceiver loads = 32. Maximum data rate = 10Mbps for cable lengths up to 40ft. Maximum cable length = 4000ft for data rates up to 100kbps. Vcm TTL in TTL out TTL in TTL out TTL in TTL out D D D S-485 transceiver S-485 transceiver S-485 transceiver T T T = Termination 120 ohm S-485 telemetry T = Termination 120 ohm binary data char 'A' = 41 hex start data stop 0 1 0 0 0 0 0 1 0 1 5V Figure 3: Typical S-485 Application Major S-485 specifications: Driver loaded output voltage 1.5V Driver open circuit output voltage 6.0V Driver short circuit current (-7V to +12V) 250mA Common mode range (V cm) -7V to +12V eceiver thresholds ± 200mV 2008 Kongsberg Mesotech Ltd. Page 5 of 12

5. DIGITAL TELEMETY Digital telemetry, as used in this document, is a loose term used to describe the serial communications link between the KML Digital Surface Processors and the KML Digital Sonar Heads, as well as KML Digital Altimeters. KML Digital Heads sample the analog sonar return signal to convert it to digital data samples, which are sent to the Surface Processor over the digital telemetry link. The Surface Processor may either be: A sub-system consisting of a PC running host software (e.g. MS1000) that communicates to the Sonar Head either directly by S-232C or S-485 serial link. The KML MS1000 Head Interface Box is available to provide head power and S-485 telemetry interface; the PC interfaces to this box via S-232C or USB (depending on model) serial connection. A KML Surface Processor (e.g. MS900D, MS1000) that integrates host PC and Head Interface Box functions into a single turnkey unit. The telemetry link from the Surface to the Head(s) is referred to as the downlink data flow, and the link from the Head(s) to the Surface is referred to as the uplink data flow. Digital telemetry data is generated as a serial bitstream in the format described in section 5.1. This serial bitstream is send to the telemetry driver which converts the data bits into S-232/S-422/S-485 voltage levels and drives the telemetry link. KML Digital Heads provide built-in power-up auto-detect selection between S-232 and S-485 serial interface. Consequently, the interface type selection is driven by that used at the surface. For KML turnkey Surface Processors, this is user-configurable. For KML Head Interface Boxes, S-485 is normally implemented. 5.1 Telemetry Data Format All telemetry information is sent in serial bitstreams, one bit at a time, in the following 10-bit packet format: Start = 1 bit Data = 8 bits Stop = 1 bit Parity = None The 8-bit data is sent with the lsb (least significant bit) first, and the msb (most significant bit) last. Although the term actually only applies to the data portion, the whole telemetry packet is usually referred to as a telemetry character. Figure 4 shows the data format and binary levels to send the ASCII character A (binary value = 41H). 2008 Kongsberg Mesotech Ltd. Page 6 of 12

BITS = STAT 0 1 2 3 4 5 6 7 STOP lsb msb BINAY = 0 1 0 0 0 0 0 1 0 1 STAT DATA = character 'A' (41H) STOP Figure 4: Telemetry Data Format 5.2 Telemetry Data ates The uplink baud rate is variable in increments of 300bps, but for compatibility reasons only de-facto standard rates of 9600, 19200, 38400, 57600, 76800, 115200, 230400, 460800, and 921600bps are implemented (maximum rate may be limited by head and surface processor capabilities). The uplink rate initially is set to the default bit rate ("DB"), normally 9600bps. The downlink baud rate may either be fixed to DB or variable, depending on the capabilities available in the head and surface processor. If variable is supported, the downlink rate will be set to the uplink rate. Variable downlink capability is useful in systems and applications where different up and downlink rates cannot be tolerated. The variable downlink baud rate mechanism, supported in more recent software revisions, is backward-compatible with older, fixed-downlink rate systems. This allows, for example, heads with variable downlink baud rate capability to operate at DB when connected to a surface processor requiring fixed downlink rate operation. On power-up, DB is assumed for both downlink and uplink. Subsequently, after system self-test and initialization sequences are complete, the uplink rate is normally auto-optimized by a Surface-Head negotiation process to select the fastest supported baud rate that passes all telemetry tests. If variable downlink rate is supported in the surface processor and the head, the downlink rate is also adjusted accordingly (to equal the uplink rate) during the negotiation sequence. DB is normally 9600bps, but can be changed if such capability is available in the head and surface processor. This feature is useful to support applications requiring up & downlink be fixed to a specific bit rate on power-up. Changing DB involves remote changing of a setting stored in the head's internal non-volatile configuration memory. 5.3 Telemetry Protocol KML digital telemetry implements a Master-Slave relationship between the Surface Processor and Digital Heads, and uses a Half-Duplex telemetry protocol. All communications take place in the form of predefined, formatted messages. These messages contain commands, responses, requests, parameters, data, etc. and are identified by unique message types. 2008 Kongsberg Mesotech Ltd. Page 7 of 12

Master-Slave relationship: The Surface processor is always the Master, and the Heads are always Slaves. All communications are initiated by the Master. Slaves can never initiate any communications, but can only respond to messages from the Master, using matching response messages. Telemetry message transactions: All telemetry communications are conducted as individual transactions. A transaction starts when the Master sends a message to a Slave, and terminates when the Master receives a response from that Slave. Half-Duplex operation: Operating in Half-Duplex mode, there can not be more than one active telemetry driver on the telemetry link, and all other telemetry agents must be in receive mode. When there is no telemetry activity, the Master and all Slaves are in receive mode. To maintain a "mark" signal level on the telemetry link when all agents are in receive mode, the Master side telemetry drivers and receivers implement failsafe termination resistors to force a differential voltage of more than 200mV on the telemetry link. Third party telemetry systems between a digital head and the surface processor are expected to also implement this failsafe resistor termination on the Master side. A typical S-485 failsafe termination resistor network is shown in Figure 5. 5V DIVE 750 CV 750 130 > 200mV Figure 5 : S485 Failsafe Termination 5.4 Telemetry Timing The telemetry protocol mandates link turnaround times between send and receive, and between receive and send. This is required to eliminate data collisions in half-duplex operation and also allows telemetry subsystems to implement auto-sensing techniques to correctly switch between uplink and downlink telemetry in half-duplex operation. 2008 Kongsberg Mesotech Ltd. Page 8 of 12

The telemetry protocol also mandates certain inter-character timeouts to prevent the telemetry agents from waiting forever for a transaction to complete. This is required in the event of data loss due to very noisy telemetry lines. Half-Duplex Turnaround Timing: All telemetry turnaround times are fixed and not related to the actual baud rates in effect. After the stop-bit of the last character of a message has been shifted out of the sender s output shift register, the telemetry driver shall be in high-impedance state within 3ms. After receiving the last complete telemetry character of a transmission in its receive buffer, a telemetry agent shall wait at least 3ms before enabling its telemetry driver. Note that this timing protocol produces a receive only period of at least 1ms between transmissions during which all telemetry agents are in receive mode. This 1ms roughly equals the transmission time of 1 character at 9600bps. Inter-Character Timing: The time delay between 2 successive valid telemetry characters on the telemetry link shall not exceed 500ms. This allows the receiver to timeout if a transaction takes too long to complete, and prevents the telemetry system from lock-up. 2008 Kongsberg Mesotech Ltd. Page 9 of 12

6. ANALYSIS OF MEASUED S-485 AND S-232 SIGNALS Figure 6 and Figure 7 show the S-485 and S-232 telemetry signals for sending the character A (41H) at a baud rate of 9600bps. Observe the following characteristics of the data bits of both S-485 and S-232 signals: Data bit 0 (lsb) is send first, and data bit 8 (msb) is sent last. The data bits are framed by 1 start bit and 1 stop bit. Observe the following differences between the S-485 and S-232 telemetry signals: The S-485 signal is differential, as a pair, with one signal of the pair the inverted replica of the other, while the S-232 is a single signal with the data inverted from the binary values of the data bits. The S-485 signal pair are both unipolar, with a switching range of about 4V, while the S-232 signal is bipolar, switching from -10V to +10V. S-485 drivers are enabled before sending data and disabled after sending data, while the S-232 drivers are always enabled. Figure 6 : S-485 Telemetry format and timing at 9600bps 2008 Kongsberg Mesotech Ltd. Page 10 of 12

Figure 7: S-232 Telemetry format and timing at 9600bps Figure 8 shows a typical step-and-ping command/response transaction between a KML Surface Processor and a KML Digital Head in an example where the downlink rate is fixed at 9600bps. The figure includes time-zoomed views of portions of the telemetry sequence. In response to the STEP-PING command, the Digital Head activates the acoustic transmit pulse and samples (digitizes) the analog sonar return. These digitized sonar data samples are not uplinked to the surface in real-time, but are captured in a local buffer before the Head uplinks them. Surface controlled gain is applied to the digital sonar samples numerically in the Head software. The Surface Processor receives the uplinked sonar data samples and converts them to colored pixels and sends them to a CT display as a visual representation of the sonar return. 2008 Kongsberg Mesotech Ltd. Page 11 of 12

Figure 8: S-485 STEP-PING command/response transaction 2008 Kongsberg Mesotech Ltd. Page 12 of 12