Certificate of Conformity

Similar documents
Certificate of Conformity

Certificate of Conformity

Certificate of Conformity

Certification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT

IECEx Certificate of Conformity

Certificate of Conformity

Power supply. Calibration. Surface finishing. Seal. Process connection

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

IECEx Certificate of Conformity

R88000 T (including ATEX)

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

CERTIFICATE OF COMPLIANCE

Emerson (Appleton Group ATX)

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

IECEx Certificate of Conformity Annexe

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

IECEx Certificate of Conformity

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Intrinsic Safety Control Drawing

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

IECEx Certificate of Conformity

Certificate of Compliance

Safety Instructions Nivotester FTC625, FTC325

A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

IP26 Series Current to Pneumatic Converter

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

Product manual wire programmable RTD transmitter

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

SELECTION GUIDE. Interfaces galvanic insulation.

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Temperature Input Module for Zone 1 Series 9482/32

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Temperature Transmitters TMT 136, TMT 137

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

CERTIFICATE OF COMPLIANCE

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

Isolators A3/1. Vibration Transducer Supply Unit Series

DPharp Differential Pressure and Pressure Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters

Loop Powered Indicator

Binary Output without Power Supply Series 9176

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

ATEX Installation Drawings and Instructions

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

Product Manual wire HART transmitter

General Specifications

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

SET Installation and Operating Instructions. Level switch for two sensors

Positioner with HART Communication Type 3780

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Operating Manual. isolate501

IECEx BVS X issue No. :3. Funkwerk Security Communications GmbH John-F. -Ken nedy-stral1e Salzgitter Germany

General Specifications

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Rosemount 148 Temperature Transmitter

Certificate of Compliance

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

IECEx Certificate of Conformity

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

Attachment to Certificate IECEx PTB X

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

PRetrans Table of contents

Binary Output Series 9175

Australian/New Zealand Standard

Inductive sensor slot-type SI2-K08-AP7

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Single-Channel Safety Barriers Series 9001

1-830 SERIES DISPLACEMENT TRANSMITTER

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SCS-400. Sealed Parcel Delivery System. Installation Manual

Universal Intelligent 2-wire DIN Rail Transmitters

SINEAX TI 807 Passive DC signal isolator

TIY Programmable, Isolated Thermocouple Transmitter combines

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Product Manual wire HART transmitter

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...

Universal Intelligent 2-wire In-head Transmitters

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

SELECTION GUIDE. Interfaces galvanic insulation.

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

User Manual mantracourt.com

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Transcription:

Applicant: Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A Electrical Apparatus: Fully Encapsulated PC-Programmable Temperature Transmitters (TRX: nonisolated; and TRY: isolated) Type of Protection: Ex ia Marking Code: Ex ia IIC T5 @ +85 ºC Manufacturer: Manufacturing Location(s): Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A As above. The EPEE certification database located at http://www.anzex.com.au shows the validity of this Certificate. Certificate issued by: TestSafe Australia 919 Londonderry Road, Londonderry NSW 2753 Australia Phone: +61 2 4724 4900 Fax: +61 2 4724 4999 http://www.testsafe.com.au www.jas-anz.com.au/register EPF019_15 Page 1 of 9

This certificate is granted subject to the conditions as set out in Standards Australia/Standards New Zealand Miscellaneous Publication MP87.1:2008. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: AS/NZS 60079.0:2005 AS/NZS 60079.11:2006 AS 60529:2004 Electrical equipment for explosive gas atmospheres Part 0: General requirements (Including Amendment 1) Explosive atmospheres Part 11: Equipment protection by Intrinsic safety i Degree of protection provided by enclosure (IP code) This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. ASSESSMENT & TEST REPORTS: The equipment listed has successfully met the assessment and test requirements as recorded in: Test Report No. and Issuing Body: 30577, TestSafe Quality Assessment Report No. and Issuing Body: 55A/7037,SIRA, Reviewed by TestSafe File Reference: 2007/025237 2 December 2009 Signed for and on behalf of issuing body Date of Issue Quality & Certification Manager Position This certificate is not transferable and remains the property of the issuing body and must be returned in the event of it being revoked or not renewed. EPF019_15 Page 2 of 9

EQUIPMENT: Schedule The PC- Programmable Temperature Transmitter TRX: non-isolated model is fully encapsulated within a plastic enclosure and the electrical connections are provided with screw terminals on top of the plastic enclosure. There are two PCBs in this model. The PC- Programmable Temperature Transmitter TRY: isolated model is fully encapsulated within a plastic enclosure and the electrical connections are provided with screw terminals on top of the plastic enclosure. There are three PCBs in this model. Each model of apparatus provides a proportional 4-20 ma signal output derived from input signal of an RTD probe or a thermocouple or a milli-volt source of maximum 1000 mv. The PCB assembly is identified as HPP-Style (Hockey-Puck Housing) in the instruction manual. The power supply is connected to the screw terminals marked +PS and PS. The temperature sensor is connected to the screw terminals marked 1, 2, 3 and 4 of the HPP model housing. The COM port is to be used only in the non-hazardous area and the parameters are given in the label drawing. The enclosures of both TRX and TRY Transmitters are plastic. The drawing number 204-284-01 and 204-284-02 provide details of the top and bottom part of this enclosure. EPF019_15 Page 3 of 9

CONDITIONS OF CERTIFICATION: 1. When used in Zone 0 a warning on potential electrostatic charging hazard is required. 2. The following input and output parameters must be taken into account when installed: Input parameters at + PS, PS terminals: TRY (isolated) and TRX (non-isolated) Ui = 30V Ii = 110 ma Pi = 825 mw Ci = 5.2 nf Li = 0 µh Output parameters at terminals where temperature sensor is connected: TRY Model, Terminals 1, 2, 3, 4. Uo = 6.51 V Io = 205 ma Po = 675 mw Lo = 0.410 mh Co = 5.1 µf EPF019_15 Page 4 of 9

TRX Model, Terminals 1, 2, 3, 4. Uo = 6.51 V Io = 110 ma Po = 532 mw Lo = 1.4 mh Co = 2.262 µf DOCUMENTS: PC Programmable Temperature Transmitter TRX: non-isolated 235-866-00 2 sheets PC1 Bom Description B ----/--/-- 235-882-00 TRX PC2 Bom Description D ----/--/-- 506-551-02 TRX-HPP PC1 B 2002/09/06 Primary Side Circuitry (PCB Art Work) 506-551-02 TRX-HPP PC1 B 2002/09/06 Secondary Side Circuitry (PCB Art Work) 506-551-02 TRX-HPP PC1 B 2002/09/06 Inner Layer 1 Circuitry (PCB Art Work) 506-551-02 TRX-HPP PC1 B 2002/09/06 Inner Layer 2 Circuitry (PCB Art Work) 235-582-00 PC2, T2X [HPP] TRX- R [HPP], P2X [HPP] D 2002/03/-- EPF019_15 Page 5 of 9

506-571-02 T2X [HPP] &TRX [HPP] R PC2 D 2006/01/15 Primary Side Circuitry (PCB art work) 506-571-02 T2X [HPP] &TRX [HPP] R PC2 D 2006/01/15 Secondary Side Circuitry (PCB art work) 235-466-00 TRX [HPP] R Option D 2004/08/-- (Schematic) 235-566-00 PC1, TRX [HPP] R Option B 2002/09/-- 235-568-00 3 sheets Top Assembly, TRX [HPP] R Option A 2000/03/-- ( PC Assembly) 506-551-01 2 sheets PC1, TRX [HPP] R Option B 2002/09/-- 506-571-01 2 sheets PC2, T2X [HPP] & TRX [HPP] R D 2006/01/-- 200-251-1712 Label, ANZEx TRX-ISA [HPP], Intrinsically Safe B 2009/10/- PC Programmable Temperature Transmitter TRY: isolated 235-876-00 2 sheets PC1 Bom Description C ----/--/-- 235-877-00 PC2 Bom Description B ----/--/-- 235-878-00 2 sheets List of materials PC3 F1 ----/--/-- EPF019_15 Page 6 of 9

506-556-02 TRY [HPP] R PC1 D 2002/11/22 Primary Side 506-556-02 TRY [HPP] R PC1 D 2002/11/22 Secondary Side 506-556-02 TRY [HPP] R PC1 D 2002/11/22 Inner Layer 1 506-556-02 TRY [HPP] R PC1 D 2002/11/22 Inner Layer 2 506-557-02 TRY-HPP PC2 B 2002/11/22 Primary Side 506-557-02 TRY-HPP PC2 B 2002/11/22 Secondary Side 506-558-02 PC3, TRY-R HPP G 2008/09/30 Primary Side 506-558-02 PC3, TRY-R HPP G 2008/09/30 Secondary Side 506-558-02 PC3, TRY-R HPP G 2008/09/30 Innaer Layer 1 235-476-00 PC1, TRY [HPP] R Option J 2006/08/-- (Schematic) 235-476-00 PC2, TRY [HPP] R Option J 2006/08/-- (Schematic) 235-476-00 PC3, TRY [HPP] R Option (Schematic) J 2006/08/-- EPF019_15 Page 7 of 9

235-576-00 PC1, TRY [HPP] R Option C 2002/11/-- 235-577-00 PC2, TRY [HPP] R Option B 2002/11/-- 235-578-00 PC3, TRY [HPP] R Option F 2007/02/-- 235-579-00 3 sheets Top Assembly, TRY-HPP R Option A 2000/03/-- 506-556-01 2 sheets PC1, TRY [HPP] R Option D2 2008/07/-- 506-557-01 2 sheets PC2, TRY [HPP] R Option B 2002/11/-- 506-558-01 2 sheets PC3, TRY [HPP] R Option G 2008/09/-- 235-569-00 Front Panel Sub-Assembly TRX / TRY R Option A 2000/03/-- (Mech Assembly) 200-251-1721 Label, ANZEx TRY-ISA [HPP], Intrinsically Safe B 2009/10/- 205-248-00 TRY Case Assembly R Option B 2004/09 Mech Assy) 204-284-01 TRX / TRY Case Top B 1995/06/- (Fabrication) 204-284-02 TRX / TRY Case Bottom (Fabrication) A 1995/06/- EPF019_15 Page 8 of 9

235-710-01 TRY & TRX PC-Programmable Temperature Transmitters (Service manual) N 2005/04/- EPF019_15 Page 9 of 9