Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

Similar documents
FP-e Series Programmable Controllers. 48 mm

Panel Mounted Controller

Ultra-Slim PLC (FP Sigma)

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

PFXLM4B01 D * * (1) (2) (3) (4)

PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Safety Precautions. Copyright / Trademarks

PFXLM4201T A D * * (1) (2) (3) (4) (5) (6)

NX70/NX700 Series Pulse I/O Modules (4CH) (NX70-PULSE4 and NX-PULSE4 ) User Manual

Data Acquisition Modules/ Distributed IO Modules

Solid-state Timer H3DS

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

02/11/2015


APPENDIX APPENDIX A 1

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

Multi Function Timer with Free power, Compact size W38 H42mm

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

02/11/2015

ADAM 4000/4100 Series

PROCESS & TEMPERATURE CONTROLLERS

Solid-State Digital Counter H7AN

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

FA Wireless SS Terminals

DC1010/DC1020/DC1030/DC1040

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System


Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

Fuzzy Temperature Controllers E5AF

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Count/Time Totalizers

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Industrial Modbus I/O Modules

Digital Multimeters R6451A/6452A. R6451A/6452A Digital Multimeters. 5 1/2 Digit DMM Series Enabling Dual Input and Display

General Specifications

MICRO-CONTROLLER X (48 48 mm)

General Specifications

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

High-speed, wireless communication with easy installation and simple wiring!! *Antenna sold separately. 250 m range. Antenna with cable available

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

General Specifications

The wireless alternative to expensive cabling...

Solid-state Timer H3DE

General Specifications

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

CAN-IO Custom IO remote module

NA1-PK3 SERIES. Compact Size Picking Sensor. Boasts a compact, pocket lighter size enabling universal installation

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

MU110-16R(K) Digital output module 16 channel. User guide

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

EE-SPX303/403. Ordering Information. Large Slot Width (13 mm) Not Influenced by External Light. H Easy adjustment and optical axis monitoring

Model Number Structure

WHEN A PLC IS TOO MUCH, AND SPACE FOR

A new approach to static electricity countermeasures

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

MU110-8R(K) Digital output module 8 channel. User guide

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Maximum Value for OEMs SM. NX70 High-speed Counters (NX70-HSC1, NX70-HSC2) User Manual

Distance-setting Photoelectric Sensor

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

MICRO-CONTROLLER X (96 96 mm)

The wireless alternative to expensive cabling...

Zentralbaugruppen CPU 222

General Specifications

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

MICRO-CONTROLLER X (48 96 mm)

Specifications of PFXLM4301TADAC (Modular Type Analog / Source Output Type)

CQM1H-MAB42 Analog I/O Board Connector CN1: Analog inputs 1 to 4. Name Specifications Model number Slot 1 (left slot) High-speed Counter Board

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

Custom "Compact" range with display CD20 Custom Part number

MV110-8AS. Analog input module 8 channel. User guide

Copyright / Trademarks -This manual and its contents are copyrighted. -You may not copy this manual,in whole or part,without written consent of

High Performance Process & Temperature Controllers

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Self-powered Counter

Distance-setting Photoelectric Sensor

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Analogue temperature controllers

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Intermittent Vibration 0.075

Bulletin 700-HX Multifunction Digital Timing Relay

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

02/11/2015

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

02/11/2015

Multi-point Temperature Controller

Absolute Rotary Encoder

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Features. Panel Meters with Advanced Signal Processing Capabilities K3HB

Transcription:

Panel Mount PC NEW standard: Timer Counter Temperature Controller PC From the makers of the first SIM FP0 PC, Panasonic Electric Works is proud to introduce the industry's first panel mount PC, the FP-e. This small (DIN 1/16 case) PC has a built-in bright 3 color ED panel capable of displaying up to 5 digits along with predefined units. The function keys on the front panel can be used for setting timers, counters, temperature set points, internal bits, regular data points, and can also be used as 16 additional input switches. Up to 6 screens can be programmed, and with our new wizard feature added to our FPWINGR programming software, this is even easier. The FP-e PC comes in the following three types Basic Type - 8 DC input, 5 NPN tran., and 1 relay output; Calendar Timer Type -8 DC input, 5 NPN tran., and 1 relay output; Thermocouple Input Type - 6 DC input, 2 ch. thermocouple, 5 NPN tran., and 1 relay output Key Features RS232C and RS485 Serial Ports Modem Remote Operation IP66 Protection Data ogging* Calendar Clock Timer* Thermocouple Input**

Modbus RTU Slave*** 2 Digital Number Displays 4 High Speed Counter up to 10KHz 1ms Resolution Timers 2 Axis Trapezoidal Stepper Control 2 High Speed PWM PID with Auto Tuning Floating Point Math * For AFPE224305 and AFPE214325 ** For AFPE214325 only *** Currently available for RS485 type. FPe Models You may sort models by clicking the arrows in the appropriate column. If you are searching for a particular model but can't find it, give our model search utility a try. All downloads have moved to our separate downloads center. Click one of the links below to view all related models. Models will appear below the links. Control Units Accessories Manuals And Software Currently viewing: FPe Control Units Model Name Power Pulse Outputs Thermocouple Dc Inputs Npn Outputs Relay Outputs Sort Sort Sort Sort Sort Sort Sort Sort AFPE214322 24VDC Yes Yes 6 5 1 2.7 AFPE214325 24VDC Yes Yes 6 5 1 2.7 AFPE224200 12VDC Yes No 8 5 1 2.7 AFPE224300 24VDC Yes No 8 5 1 2.7 AFPE224302 24VDC Yes No 8 5 1 2.7 AFPE224305 24VDC Yes No 8 5 1 2.7 Program Size (K)

Specification table Performance specifications Programming method/control method Number of controllable I/O points Program memory Program capacity Number of instruction Model Control unit Front switch input Built-in memory Basic High-level Operation speed I/O update and Base time Internal relay (R) Special internal relay (R) Memory backup Note 7) Special functions Operation memory points Relays Timer/Counter (T/C) Data register (DT) Special data register (DT) Index registers (IX. IY) Differential points Master control relay points (MCR) Number of labels (JP and OOP) Number of step ladders Number of subroutines Number of interrupt programs Self-diagnostic function Memory areas Clock/calendar function Note 2) Battery life Pulse catch input Interrupt input. port Note 3) Periodical interrupt Constant scan Password High-speed counter function * The combinations 1-phase 2 ch. and 2-phase 1 ch. are also possible for the high-speed counter. Pulse output function PWM output function Timer Counter Counter Internal relay Data register Output points Output frequency Output points Output frequency AFPE224300 Standard type Note 1) The proportion of timer points to counter points can be changed using a system register. Note 2) Precision of calendar timer: - At 0 C/32 F, less than 200 seconds of error per month - At 25 C/77 F, less than 70 seconds of error per month - At 55 C/131 F, less than 240 seconds of error per month Note 3) When using the. port for communication, retransmission is recommended. The RS232C driver IC for the. port conforms completely to EIA/TIA-232E and CCITT V. 28 standards Note 4) The max. counting speed (10 khz) is the counting speed with a rated input voltage of 24 V DC and an ambient temperature of 25 C. The counting speed (frequency) will decrease depending on the voltage and temperature. AFPE224302 Standard type AFPE224305 Calendar timer type AFPE214325 Thermocouple input type AFPE214322 Thermocouple input type Relay symbol/cyclic operation 14 points [Input: 8, Output: 6 (Tr. NPN: 5/Ry: 1)] 12 points [Input: 6, Output: 6 (Tr. NPN: 5/Ry: 1)] 8 points Built-in EEP-ROM 2,720 steps 83 117 0.9 µs/step (Basic instruction) Typical 2 ms 1,008 points (R0 to R62F) 64 points (R9000 to R903F) 144 points (Initial setting: 100 timer points, T0 to T99/44 counter points, C100 to C143 Note 1) Timer range (1 ms, 10 ms, 100 ms, 1 s): selected by instruction 1,660 words (DT0 to DT1659) 112 words (DT9000 to DT9111) 2 points Unlimited number of points 32 points 64 labels 128 stages 16 subroutines 7 programs (external: 6, internal 1) Watchdog timer, program syntax check, etc. (year, month, day, hour, minute, second and day of week). However, this can only be used when a battery has been installed. 220 days or more (actual usage value: approx. 870 days (25 C). (Periodic replacement interval: 1 year). (Value applies when no power is supplied at all.) 6 points in total (X0 and X1: 50 µs, X2 to X5: 100 µs) RS232C RS485 RS232C RS232C RS485 0.5 ms to 30 s Counter mode: Addition/subtraction (1-phase) Note 4) - Input points: 4 ch. (Max.) - Max. speed: 10 khz (total of 4 ch.) : 5 khz (total of 4ch.) - Input contact: X0: count input (ch. 0), X1: count input (ch. 1), X2: reset input Note 5) X3: count input (ch. 2), X4: count input (ch. 3), X5: reset input Note 5) - Min. input pulse width: X0 and X1: 50 µs (10 khz) X0 and X1: 100 µs (5 khz) X3 and X4: 100 µs (5kHz) Counter mode: 2-phase/individual/direction decision (2-phase) - Input points: 2 ch (Max.) - Max. speed: 2 khz (total of 2 ch.) : 1 khz (total of 2ch.) - Input contact: X0: count input (ch. 0), X1: count input (ch. 0), X2: reset input X3: count input (ch. 2), X4: count input (ch. 2), X5: reset input - Min. input pulse width: X0 and X1: 50 µs (10 khz) X0 and X1: 100 µs (5 khz) X3 and X4: 100 µs (5 khz) 2 independent points (Y0 and Y1) (No interpolation function) 40 Hz to 10 khz (Y0/Y1: 1-point) Note 6) 40 Hz to 5 khz (1-point) 40 Hz to 5 khz (Y0/Y1: 2-point) 40 Hz to 2.5 khz (2-point) 2 points (Y0 and Y1) Frequency: 0. 15 Hz to 1 khz Duty: 0.1 % to 99.9 % : (all points) From set value to C139 4 points (elapsed values) C140 to C143 976 points (R0 to R60F) 61 words (WR0 to WR60) 32 points (R610 to R62F) 2 words (WR61 to WR62) 1,652 words (DT0 to DT1651) 8 words (DT1652 to DT1659) Note 5) If the unit is equipped with both reset inputs X0 and X1, X2 serves as the reset input for X1. If X3 and X4 are used, X5 serves as the reset input for X4. Note 6) When the positioning control instruction F168 is performed, the maximum output frequency is 9.5 khz. Note 7) The program, system registers and the hold type area (internal relay, data register, and timer/counter) are backed up by the built-in EEP-ROM. When a battery is replaced with a new one in the FP-e unit with a calendar timer function, settings can be changed without installing a battery. The data cannot be stored even when the settings are changed using the system register. Note 8) F180 (SCR) and F181 (DSP) instructions are supported from Control FPWIN GR Ver. 2.2. and FPWIN Pro V 4.1. 5

Technical data General specifications Rated voltage Operating voltage range Allowed momentary power off time 10 ms Ambient temperature 0 to 55 C Storage temperature 20 to 70 C Ambient humidity 30 to 85%RH (non-condensing) Storage humidity 30 to 85%RH (non-condensing) Breakdown voltage Insulation resistance Output terminals (Y0 to Y4) Input terminal (A0, A1). terminal 500 V AC for 1 minute Output terminal (Y5) Input terminal (, X0 to Xn, A0, A1). terminal 1500 V AC for 1 minute Output terminals (Y0 to Y4) 500 V AC for 1 minute Output terminals (Y0 to Y5) Input terminal (A0, A1). terminal Min. 100 M (measured with 500 V DC) Output terminals (Y0 to Y5) Vibration resistance 10 to 55 Hz, 1 cycle/min. Double amplitude: 0.75 mm, 10 min. on X, Y, and Z axes Shock resistance 98 m/s2 or more, 4 times on X, Y, and Z axes Noise resistance 1000V (p-p) with pulse widths 50 ns and 1 µs (based on in-house measurements) Operating condition Free from corrosive gases and excessive dust Current consumption 200 ma or less () Protection IP66-compliant front section (Only when a rubber packing is used.) Mass Approx. 130 g DC input specifications (X0 to X7) Thermocouple input specifications 8 points (6 points for thermocouple input type) Number of input 2 points (CH0: WX1, CH1: WX2) Optical coupler Temperature sensor type Thermocouple type K Rated input voltage Input range 30.0 to 300.0 C 1) ( 22 to 572 F) Operating voltage range Accuracy ±0.5%FS±1.5 C (FS = 30 to 300 C) Rated input current Approx. 4.3 ma Resolution 0.1 C Conversion time 250 ms/2ch 2) Input points per common 8 points/common (6 points/common for thermocouple input type) Either the positive or negative of the input power supply can be connected to common terminal. Between internal circuit and thermocouple input circuit: noninsulated 3) Between CH0 and CH1 of thermocouple input: PhotoMOS insulation Detection function of wire disconnection ON voltage/on current 19.2 V or less/4 ma or less OFF voltage/off current 2.4 V or more/1 ma or more Input impedance Approx. 5.1 k Approx. 5.6 k (X0, X1) (X2 to X7) 50 µs or less (X0, X1) Note 1) 100 µs or less (X2 to X5) Note 1) 2 ms or less (X6, X7) Response time 1) Temperature can be measured up to 330 C (626 F). When the measured temperature exceeds 330 C (626 F) or the thermocouple wiring is disconnected, K20000 is written to the register. 2) Temperature conversion for thermocouple input is performed every 250 ms. The conversion data is updated on the internal data register after the scan is completed. 3) The internal circuit and thermocouple input circuit are not insulated. Therefore, use the nongrounding type thermocouples and sheath tubes. 50 µs or less (X0, X1) Note 1) 100 µs or less (X2 to X5) Note 1) 2 ms or less (X6, X7) Operating mode indicator Note 1) 6 Number of input X0 through X5 are inputs for the high-speed counter and have a fast response time. If used as normal inputs, you should insert a timer in the program as chattering and noise may be interpreted as an input signal. Also, the above specifications apply when the rated input voltage is 24V DC and the temperature is 25 C. 01/2004

Technical data Transistor NPN output specifications (For Y0 to Y4) Output type Rated load voltage Operating load voltage range Max. load current Max. surge current Output points per common OFF state leakage current ON state voltage drop Response time External power supply (For driving internal circuit) Surge absorber Operating indicator Voltage Current Optical coupler Open collector 5 to 4.75 to 26.4 V DC 0.5 A 1 A 5 points/common 100 µa or less 1.5 V or less 50 µs or less (For Y0 and Y1), 1 ms or less (For Y2,Y3 and Y4) 50 µs or less (For Y0 and Y1), 1 ms or less (For Y2,Y3 and Y4) 6 ma/point (For Y0 and Y1) 3 ma/point (For Y2, Y3, and Y4) Zener diode. port communication specifications 1). port type RS232C 2) RS485 Isolation status with the internal circuit Non-isolated Isolated Transmission distance 15 m 1200 m Baud rate 3) 300, 600, 1200, 2400, 9600,19200 bit/s 4) 4800, 9600, 19200 bit/s Communication method Synchro system Transmission format Data output order No. of connected units Communication mode Half-duplex Synchronous communication method Stop bit: 1 bit/2 bit Parity: / (Odd number/even number) Data length 7 bit/8 bit Beginning code: STX available/stx not available Ending code: CR/CRF/not available/etx Starting from 0 bits per character 99 5) 6) General-purpose communication Computer link Relay output specifications (Y5) Output type Rated control capacity Output points per common Response time Mechanical ife time Electrical Surge absorber Operating indicator Normally open (1 Form A) 2 A 250 V AC, 2 A 30 V DC 1 point/common Approx. 10 ms Approx. 8 ms Min. 2 10 7 operations Min. 10 5 operations (resistive load) None 1) When communicating between FP-e and other devices, it is recommneded to perform resend processing. 2) For RS232C wiring, be sure to use shielded wires for higher noise immunity. 3) Set the baud rate of RS485 with the FP-e system register and FP-e internal switch. Set the baud rate of RS232C with the FP-e system register. 4) When sending a command from the FP-e is completed in RS485 communication, send a response from the receiving device to the FP-e after the following time has elapsed: 9600 bit/s: 2 ms or longer 19200 bit/s: 1 ms or longer It takes at least 1 scan time (at least 2 ms) for the FP-e to send back a response after received the command. 5) When our C-NET Adapter or RS485 device other than recommended is connected in the system, the maximum connection number is limited to 32 units. 6) For a RS485 converter on the computer side, SI-35 (from INE EYE Co., td.) is recommended. When SI-35 is used in the system, up to 99 units can be connected. 19200 bit/s 9600 bit/s Dimensions (mm) Wiring diagram Input connector (Standard type) (Thermocouple input type) 48 70 7.5. 44.5 X0 X1 X2 X3 X4 X5 X6 X7 Output connector Power Y0 Y1 Y2 Y3 Y4 YC Y5 TC0 TC1 () Y0 to Y4 () Y5 X0 X1 X2 X3 X4 X5 A0 A0 A1 A1 Xn Power supply/. port connector (RS232C type). port Send data (Output) Receive data (Input) Signal (RS485 type) (Terminal station) (Ordinary station). port Short E. port SD RD SG E 7