Plug-In Timer pins Multifunction or monofunction Compact body for space saving Wide time range (from 0. seconds to 0 days delay) niversal power supply (-0 Vz) or relay outputs (SPDT / Changeover) Protective cover LED status indicator -wire PNP sensor compatible -pins connections OR0MV Multifunction - Monofunction Ad - N OAR0MV Monofunction A OCR0MV Monofunction C OLR0MV Monofunction L - Li Product selection Function Output Supply Voltage Part Number Multifuntion : (A, At, B, C, H, Ht, D, Di, Ac, Bw) Ad - N relay to 0 Vz OR0MV A relays to 0 Vz OAR0MV C relay to 0 Vz OCR0MV L - Li relay to 0 Vz OLR0MV PART NMBERING SYSTEM Type O: Plug-in -Pins P: Plug-in -Pins Output Quantity : Output : Outputs Output Power 0: 0 A O A R 0 MV Function A: ON-Delay C: OFF-Delay L: Repeat Cycle : Multifuction Output Type R: Relay Power Supply MV: -0V AC/DC You have a project? Contact us on www.crouzet.com Description: Syr-line, the new specialized range at Crouzet, aimed to satisfy the most unique requirements of your applications by innovating in design, engineering and development. The Plug in Analog Timers, a new family of timers with multifuction or monofunction, universal power supply, wide time range, with all the classic functions. For more information about Crouzet s Syr-line range, please visit www.crouzet.com.
ATOMATION.CROZET.COM Power Supply Rated supply voltage n to 0 Vz Voltage supply tolerance - %, 0 % AC supply voltage frequency 0 / 0 Hz ± % Galvanic isolation of supply / inputs Power consumption @ n Immunity to power micro cuts Timing Control No Approx. VA (VAC). W (VDC) 0 ms Specified time ranges () (IEC -) 0...0 s, 0.0.. min, 0...0 min, 0.0.. h, 0...0 h, 0.0.. day, 0...0 days Minimum control pulse duration (IEC - ) Recovery time (after by de-energisation) (IEC -) 0 ms 00 ms with load 0 ms Repeatability (IEC -) ± 0. % Setting Accuracy (IEC -) ± 0 % Temperature drift ± 0.0 % / C Voltage drift Relay output Contact arrangement ± 0. % / V CO (SPDT) (ChangeOver -Single Pole Double Throw-) CO (SPDT) (ChangeOver -Single Pole Double Throw-) CO (SPDT) (ChangeOver -Single Pole Double Throw-) Maximum switching voltage Switching current rate (resistive) Minimum switching contact Maximum switching power (resistive) Electrical life Maximum rate (at max switching power) Mechanical life Rated impulse voltage Dielectric strength between coil / contacts (IEC 0-) Dielectric strength between open contacts Insulation Rated Insulation voltage (IEC 0-) Insulation coordination (IEC 0-) Rated impulse voltage (IEC 0-) Clearance / Creepage distances (IEC 0-) Dielectric strength (EN--) Insulation Resistance (NFC 9 00) General specifications Status indication (LED) Casing Mounting Housing material (L9) Degree of protection (IEC 09) 0 Va/ 0 A resistive / Vc / 0. A resistive 0 A 0 Va / 0 A 0 Vc @ 0 C A 0 Va / A 0 Vc @ 0 C 0 ma / Vc 00 VA / 00 W 0 A 0 Va / 0 A 0 Vc @ C A 0 Va / A 0 Vc @ 0 C 0 cycles min at 0 Va/ 0 A resistive(no only) 0 cycles /hour 0 x 0 cycles kv (./0 µs). kv / min / ma / 0 Hz kv / min / ma / 0 Hz 0 V 0 A 0 Va / 0 A 0 Vc @ 0 C A 0 Va / A 0 Vc @ 0 C Overvoltage category III; pollution degree ; up to 000 m above sea level kv (./0µs) mm /. mm. kv / min / ma / 0 Hz > 00 MOhms / 0 Vc / min n: green LED blinks when count, flash when waiting Y, continuous ON when supplied R: yellow LED blink when only R is ON (instantaneous), continuous ON when the relays are ON. mm Mounting base-mounted on socket Enclosure plastic type V0 IP0
ATOMATION.CROZET.COM Operating temperature (IEC 00-) -0 C to 0 C Storage temperature (IEC 00-) -0 C to 0 C Humidity (IEC 00--0) Vibration resistance (IEC 00--) Shock resistance (IEC00--) Drop to concrete floor (IEC 00--) Weight Standards CEE Directive (0/0/E 0//E) Approvals / Marking Security standard (IEC 0-) Conformity with environmental directives (0//E 90/00 0/9/E) Product standard (IEC - L 09--) Electromagnetic compatibility (IEC 000- - IEC 000-- IEC 000--) Immunity to electrostatic discharges (IEC000--) Immunity to radiated, radio-frequency, electromagnetic field (IEC000--) Immunity to rapid transient bursts (IEC 000--) Immunity to shock waves on power supply (IEC 000--) Immunity to radiofrequency in common mode (IEC 000--) Immunity to voltage dips and breaks (IEC 000--) AC/DC main port emissions (IEC 000-- IEC 000--) Radiated emissions (IEC 000-- IEC 000--) 9 % without condensation ± 0.mm from 0 Hz 0 Hz g from 0 Hz..0 Hz 0 gn - ms ; x axis (Output non-energized) gn - ms ; x axis (Output energized) High: 0. m 90 g 0 g with packaging EMC Low voltage CE clus Listed Industrial Control Equipment Insulation coordination for equipment within low-voltage systems RoHS Reach WEEE Specified time relays for industrial use Industrial Control Equipment (NRNT- Industrial Control Switches) Refer to L0 InsulationCoordinationfor Electrical Equipment Generic standards Immunity for industrial environment Emission residential environment Emission industrial environment Level III Air ± KV / Contact ± KV Level III 0V/m (0 MHz to GHz) 0% AM ( khz) V/m (. to GHz) 0% AM (KHz) V/m ( to. GHz) 0% AM (KHz) direct ±kv /0 Tr/Th ns KKz & 00KHz Capacitive coupling clamp ± KV /0 Tr/Th ns KHz & 00 KHz Level III: line-to-earth ±kv / line-to-line ±kv Level III: 0 Vrms (0. to 0 MHz) 0 % AM ( khz) 0 % residual voltage during cycle (Crit. B) 0 % residual voltage / 0 cycles 0Hz / cycles 0Hz (Crit. C) 0 % residual voltage / cycles 0Hz / 0 cycles 0Hz (Crit. C) Short interruptions: 0 % residual voltage / 0 cycles 0Hz / 00 cycles 0Hz (Crit. C) CISPR -- (..), CISPR -- (.) 0. MHz 0. MHz, db(μv) db(μv) quasi-peak, db(μv) db(μv) average 0. MHz MHz, db(μv) quasi-peak, db(μv) average MHz 0 MHz, 0 db(μv) quasi-peak, 0 db(μv) average CISPR - 0. MHz 0 MHz CISPR -- (..), CISPR -- (.) 0. MHz 0. MHz, 9 db(μv) quasi-peak, db(μv) average 0. MHz 0 MHz, db(μv) quasi-peak, 0 db(μv) average CISPR -- 0 MHz 0 MHz, 0 db(μv/m) Quasi-peak at 0 m 0 MHz 000 MHz, db(μv/m) Quasi-peak at 0 m Or: 0 MHz 0 MHz, 0 db(μv/m) Quasi-peak at m in a semi-anechoic chamber 0 MHz 000 MHz, db(μv/m) Quasi-peak at m in a semi-anechoic chamber
ATOMATION.CROZET.COM Function Diagrams Basic Time Chart Function A - On-Delay (Delay on make) Function Ac - On/Off Delay (Delay on make/break) Function Ad - Delay on Start Function At - Summation time relay Function B - One-Shot Function Bw Function C - Off-Delay (Delay on break) Function D - Symmetrical flashing (OFF Start) Function Di - Symmetrical flashing (ON Start) Function H - Interval Function Ht - Interval summation time relay Function L - Recycler (OFF Start)
ATOMATION.CROZET.COM Function Li - Recycler (ON Start) Function N - Watchdog Connections OR0MV - OCR0MV OAR0MV R Y R R OLR0MV R Y Outline dimensions (mm) ±0.. ±0.. ±0..9±0.. ±0..0 ±0. ±0. Socket RECOMENDED SOCKET Pins for DIN Rail or Panel Mount (P/N: 0) Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warrantly or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsability of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. nder no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.