WIRING. Model BC Flow Totalizer, Ratemeter and Batch Controller Wiring Diagrams

Similar documents
WIRING. Model FC Mass Flow Computer Wiring Diagrams

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Proven Measurement for A World of Applications

Micro-controller based 16-Channel RTD Scanner

Creating a VEX IQ Event in Tournament Manager (TM)

Free Crochet Pattern Lion Brand Off The Hook Milo Blanket Pattern Number: L80261 Designed by Kaz

TABLE OF CONTENTS CHAPTER NO. TITLE PAGE NO. LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS AND ABBREVIATIONS

Simplification of Lighting and Light-Signalling Regulations

ASHIDA Numerical OC/EF Protection Relay

1. SALIENT FEATURES OF THE DIPLOMA PROGRAMME IN MECHANICAL ENGINEERING (TOOL AND DIE)

APPLICATION FOR APPROVAL OF A IENG EMPLOYER-MANAGED FURTHER LEARNING PROGRAMME

!"#$%&'()*"+,-./0) $'&413-##-%+,-./

Name:... Date:... Use your mathematical skills to solve the following problems. Remember to show all of your workings and check your answers.

Global Water Instrumentation, Inc.

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

GAME DESIGN CHRISTCHURCH CASINO S MAJOR POKER CHAMPIONSHIPS PROMOTION

DLS DEF1436. Case 2:13-cv Document Filed in TXSD on 11/19/14 Page 1 of 7 USE CASE SPECIFICATION VIEW ELECTION CERTIFICATE RECORD

Romanian National Short Wave Championship. YO DX HF Contest Rules for the foreign participants

Revised Curriculum for Bachelor of Computer Science & Engineering, 2011

ASHIDA Numerical 3OC + 1EF Protection Relay

B850 Boiler House Energy Monitor

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Global Water Instrumentation, Inc.

INTERPLANT STANDARD - STEEL INDUSTRY. MEASUREMENT OF MOISTURE CONTENT (Second Revision) IPSS: (Second Revision)

Installation, Operation and Maintenance Manual

MATH 1112 FINAL EXAM REVIEW e. None of these. d. 1 e. None of these. d. 1 e. None of these. e. None of these. e. None of these.

Product Specification OC-48 SR-1/STM S-16 Multirate 2x10 SFF Transceiver FTLF1321S1xTL

Regents Physics Mr. Mellon Based on Chapter 22 and 23

DESCRIPTION DOCUMENT FOR WIFI TWELVE INPUT TWELVE OUTPUT BOARD HARDWARE REVISION 0.1

Control Cable installation: Best Practice

UL CONDITIONS OF ACCEPTABILITY

RF LEVEL TRANSMITTER. Series RFLT 900

Photodiode Detector with Signal Amplification XB8816R Series

TECHNICAL MANUAL OPERATOR, ORGANIZATIONAL, DIRECT SUPPORT, GENERAL SUPPORT, AND DEPOT MAINTENANCE MANUAL

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.



THE OFFSHORE PETROLEUM PRODUCTION AND PIPE-LINES (ASSESSMENT OF ENVIRONMENTAL EFFECTS) REGULATIONS 1999 (AS AMENDED) PETROLEUM OPERATIONS NOTICE No.

ISRAEL RAILWAYS LTD. INFRASTRUCTURE DIVISION TRACK AND RIGHT OF WAY DEPARTMENT. for

MP Series Radar Transmitter Installation & Operation Manual

Multi level Inverter for improving efficiency of PV System using Luo Converter

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Application Note. ACT5028 Resolver-To-Digital Converter (RDC) Evaluation Board. Application Note AN5028-1

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

PF100 Active power factor correction and harmonic attenuation module Vin, 100 watts

Sample Questionnaire I

Linear X-Ray Photodiode Detector Array with Signal Amplification

Product Specification 10Gb/s Laserwire Serial Data Link Active Cable FCBP110LD1Lxx

Product Specification Gb/s RoHS Compliant Short Wavelength 2x5 SFF Transceiver. FTLF8519F2xTL

TABEL OF CONTENTS CHAPTER TITLE PAGE ABSTRAKT TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES LIST OF SYMBOLS

TABLEAU DES MODIFICATIONS

Product Specification Gb/s RoHS Compliant Short Wavelength 2x5 SFF Transceiver. FTLF8519F2xCL. FTLF8519F2xCL

B850 Boiler House Energy Monitor

SYLLABUS. osmania university UNIT - I UNIT - II UNIT - III CHAPTER - 4 : OPERATIONAL AMPLIFIER

Product Specification OC-12 SR-1/STM I-4 or OC-12 IR-1/STM S-4.1 2x5 SFF Transceiver FTLF1322F2xTR

1) What meter do I need in this application?

TABLE OF CONTENTS CHAPTER TITLE PAGE

Type: ADR233A (ADITYA V2 Series) (Preliminary) ASHIDA Numerical 3 Phase Tx. Differential Protection Relay

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

WhyTry Elementary Game Plan Journal

High Performance Coriolis Flowmeters. Transmitter : MT9411. SUS316L, SUS316L +Alloy C, Alloy C Housing

DECENTRALIZED INTERCOMMUNICATION CONCEPT

HASP Payload Specification and Integration Plan

Signet 9900 Transmitter

Product Specification. Short-Wavelength Pluggable SFP Transceiver FTRJ D

3GPP TS V ( )

DQM601 / DQM SEP 2003 Page Digital Outputs HE550DQM601 / HE559DQM601 24VDC Out, Negative Logic HE559DQM606 24VDC Out, Positive Logic

Product Specification. 6.1 Gb/s Short-Wavelength SFP+ Transceiver FTLF8526P3BNL

Programmable Attenuators

SYLLABUS. osmania university CHAPTER - 1 : OPERATIONAL AMPLIFIER CHAPTER - 2 : OP-AMP APPLICATIONS ARATORS AND CONVERTERS

Announcing: The 2009 CQ World-Wide WPX Contest RTTY: February 14-15, 2009 Starts: 0000 GMT Saturday Ends: 2359 GMT Sunday

ITEC2620 Introduction to Data Structures

Maxim Integrated Products 1

Product Specification Gb/s RoHS Compliant Short-Wavelength 2x7 SFF Transceiver. FTLF8524E2xNy

Laboratory Accreditation Programmes

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

Publications and Training Solutions Course Syllabus:

This document is not copyrighted. This document may be reproduced, in part or in whole, for any purpose. Ray Montagne - W7CIA

The Elements of Smyle (Transceiver Design)

GOVERNMENT OF ANDHRA PRADESH FINANCE (HRM.V-PC) DEPARTMENT

Product Specification OC-48 IR-1/STM S-16.1 Multirate 2x10 SFF Transceiver FTLF1421S1xCL

5 th Grade Powers of 10. Part I. What are powers of 10?

Global Water Instrumentation, Inc.

CL86T. 24~80VDC, 8.2A Peak, Closed-loop, No Tuning. Descriptions. Closed-loop. Stepper. Applications. Datasheet of the Closed-loop Stepper CL86T

Product Specification. 3.7 Gb/s RoHS Compliant Short-Wavelength SFP Transceiver FTLF8524P3BNL

UNSIGNED HARDCOPY NOT CONTROLLED. REFERENCES MS90178 Standard 24-Value Series Decade for Electronic Components of 5-, 10-, and 20-Percent Tolerance

THE OFFSHORE PETROLEUM PRODUCTION AND PIPE-LINES (ASSESSMENT OF ENVIRONMENTAL EFFECTS) REGULATIONS 1999 (AS AMENDED) PETROLEUM OPERATIONS NOTICE No.

ENHANCING THE PERFORMANCE OF DISTANCE PROTECTION RELAYS UNDER PRACTICAL OPERATING CONDITIONS

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

Electro-Magnetic Flowmeters COPA-XE

Mass and Volume Flow Transmitter

Smith Meter AccuLoad III-N4


Product Specification Quadwire 40 Gb/s Parallel Active Optical Cable FCCx410QD3Cyy

Product Specification. RoHS-6 Compliant Industrial Temperature 10Gb/s 10km XFP Optical Transceiver FTLX1412D3BTL

Product Specification. RoHS-6 Compliant 10Gb/s 10km Datacom XFP Optical Transceiver FTLX1412D3BCL

Publications and Training Solutions Course Syllabus:

XDC 6000 Watt and Watt Series Digital Programmable DC Power Supply. Operating Manual

Transcription:

WIRING Model BC Flow Totalizer, Ratemeter and Batch Controller Diagrams

Model BC Flow Totalizer, Ratemeter and Batch Controller Diagrams CONTENTS introduction I. ForceMeter TM with Internal Power...3 II. ForceMeter TM with External Power...4 III. Niagara Meters 1050 with Internal Power Pulse Output...5 IV. Niagara Meters 1050 with Internal Power Current Output...6 V. Niagara Meters 1050 with External Power Current Output...7 VI. Niagara Meters 1050 with External Power Pulse Output...8 VII. Niagara Meters Magmeter 6600 with Internal Power Active Frequency/Pulse Output...9 VIii. Niagara Meters Magmeter 6600 with Internal Power Current Output...10 IX. Niagara Meters 6600 with External Power Passive Frequency/Pulse Output...11 x. MTX/WPX 573 with External Power...12 xi. MTX/WPX 840 with Internal Power...12 xii. MTX/WPX 860 with Internal Power...13 xiii. Model R11 or R12 with Internal Power...13 xiv. Model R15B with Internal Power...14 xv. Model R22B with Internal Power...14 xvi. Model R22C with Internal Power...15 xvii. Model R25 with Internal Power...15

INTRODUCTION This guide illustrates the proper wiring connections required for the Model BC Flow Totalizer, Ratemeter and Batch Controller to be connected with other Niagara Meters products. These diagrams should be consulted during installation and for any maintenance. Please consult the associated Installation and Operation Manual (IOM) for additional details and instructions. Niagara Meters Customer Support can be reached at (800) 778-9251 for additional inquires. 2

I. ForceMeter TM with Internal Power Conduit Entry for Customer Conduit Entry for Customer Customer 4-20mA Output 24 V Remote Transmitter Transmitter Enclosure Pre-wired to Transmitter Customer Customer Belden 8418 or Equivalent Meter Enclosure Pre-wired to Meter Sensing Element 24 V 3

II. ForceMeter TM with External Power Conduit Entry for Customer Conduit Entry for Customer Power Supply 12-36 VDC Customer 4-20mA Output Remote Transmitter Transmitter Enclosure Pre-wired to Transmitter Customer Customer Belden 8418 or Equivalent Meter Enclosure Power Supply 18-36 VDC Pre-wired to Meter Sensing Element 4

III. Niagara Meters 1050 with Internal Power Pulse Output SW1 OP CAL TP5 R CAL C1 SW2 R2 RP2 RP3 RP1 +VIN P OUT I OUT Gnd + Voltage In 0 1000 Hz 4 20mA ZERO CAL TP3 CUTOFF TP1 GND * RTD Optional Remote Transmitter Model 1050 (A) + E (B) + S (C) S (D) E RTD 1 2 3 4 1 2 GRN WHT RED BLK + E + S S E + VIN POUT I OUT GND + VDC 75 of 18 gauge wire Bottom Board Top Board 24 5

IV. Niagara Meters 1050 with Internal Power Current Output SW1 OP CAL TP5 R CAL C1 SW2 R2 RP2 RP3 RP1 +VIN P OUT I OUT Gnd + Voltage In 0 1000 Hz 4 20mA ZERO CAL TP3 CUTOFF TP1 GND * RTD Optional 24 Remote Transmitter Model 1050 (A) + E (B) + S (C) S (D) E RTD 1 2 3 4 1 2 GRN WHT RED BLK + E + S S E + VIN POUT I OUT GND + VDC 75 of 18 gauge wire Bottom Board RTD Optional * Top Board 24 6

V. Niagara Meters 1050 with External Power Current Output SW1 OP CAL TP5 R CAL C1 SW2 R2 RP2 RP3 RP1 +VIN P OUT I OUT Gnd + Voltage In 0 1000 Hz 4 20mA Power Supply 12-36 VDC ZERO CAL TP3 CUTOFF TP1 GND * RTD Optional Remote Transmitter Model 1050 (A) + E (B) + S (C) S (D) E RTD 1 2 3 4 1 2 GRN WHT RED BLK + E + S S E + VIN POUT I OUT GND + VDC Power Supply 12-36 VDC 75 of 18 gauge wire Bottom RTD Optional Board * Top Board 24 7

VI. Niagara Meters 1050 with External Power Pulse Output SW1 OP CAL TP5 R CAL C1 SW2 R2 RP2 RP3 RP1 +VIN P OUT I OUT Gnd + Voltage In 0 1000 Hz 4 20mA Power Supply 12-36 VDC ZERO CAL TP3 CUTOFF TP1 GND * RTD Optional Remote Transmitter Model 1050 (A) + E (B) + S (C) S (D) E RTD 1 2 3 4 1 2 GRN WHT RED BLK + E + S S E + VIN POUT I OUT GND + VDC Power Supply 12-36 VDC 75 of 18 gauge wire Bottom RTD Optional Board * Top Board 24 8

VII. Niagara Meters 6600 with Internal Power Active Frequency/Pulse Spare Active Frequency Pulse J1 J2 J1 J2 RDN3 J1 J2 500 Ω T 1A, 250V RDN2 RDN1 1 2 3 L N 4 5 6 NC C NO 7 8 9 10 11 12 13 14 15 NC C NO F/P F/P O/C O/C I I Remote Transmitter Spare Active Frequency Pulse J1 J2 J1 J2 RDN3 J1 J2 500 Ω T 1A, 250V RDN2 RDN1 1 2 3 L N 4 5 6 NC C NO 7 8 9 10 11 12 13 14 15 NC C NO F/P F/P O/C O/C I I 24 9

VIII. Niagara Meters 6600 with Internal Power Current Output Spare RDN3 J1 J2 T 1A, 250V RDN2 RDN1 1 2 3 L N 4 5 6 NC C NO 7 8 9 10 11 12 13 14 15 NC C NO F/P F/P O/C O/C I I Remote Transmitter Spare RDN3 J1 J2 T 1A, 250V RDN2 RDN1 1 2 3 L N 4 5 6 NC C NO 7 8 9 10 11 12 13 14 15 NC C NO F/P F/P O/C O/C I I 10

IX. Niagara Meters 6600 with External Power Passive Frequency/Pulse Spare Passive Frequency Pulse J1 J2 J1 J2 RDN3 T 1A, 250V RDN2 RDN1 J1 J2 250 Ω Power Supply 12-36 VDC 1 2 3 L N 4 5 6 NC C NO 7 8 9 10 11 12 13 14 15 NC C NO F/P F/P O/C O/C I I Remote Transmitter Spare Passive Frequency Pulse J1 J2 J1 J2 RDN3 T 1A, 250V RDN2 RDN1 J1 J2 250 Ω Power Supply 12-36 VDC 1 2 3 L N 4 5 6 NC C NO 7 8 9 10 11 12 13 14 15 NC C NO F/P F/P O/C O/C I I 11

X. MTX/WPX 573 with External Power GREEN BROWN NO CONNECTION WHITE 1.27 K Ω 12 V XI. MTX/WPX 840 with Internal Power () BLACK WHITE BROWN NO CONNECTION 12 V 12

XII. MTX/WPX 860 with Internal Power GREEN WHITE 750 Ω BROWN 10K Ω 12 V XIII. R11 or R12 with Internal Power BLUE INPUT A BLACK INPUT COMMON 12 V 13

XIV. R15B with Internal Power WHITE BLACK 12 V XV. R22B with Internal Power BLACK BLACK 12 V 14

XVI. R22C with Internal Power Square Wave Black White Red 12 V XVII. R25 with Internal Power 12 V 15

150 Venture Boulevard Spartanburg, SC 29306 Tel: 800.778.9251 Fax: 864.574.8063 E-mail: sales@niagarameters.com www.niagarameters.com 2013 All rights reserved. All data subject to change without notice. M902 Rev. C