Signet Flow Transmitter

Similar documents
+GF+ SIGNET Temperature Transmitter Instructions

ph/orp Transmitter SIGNET

Signet ph/orp Transmitter * *

Contents 1. Installation

Signet Conductivity/Resistivity Transmitter

Signet Conductivity/Resistivity Transmitter

CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

Conductivity/Resistivity Transmitter

SIGNET 8860 Dual Channel Conductivity/Resistivity Controller

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter

Signet 9900 Transmitter

CX105 Conductivity/Resistivity Transmitter

Signet 8900 Multi-Parameter Controller

Signet 9900 Transmitter

8900 Multi-Parameter Controller

Signet 2610 Process Optical Dissolved Oxygen Sensor

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 2750 DryLoc ph/orp Sensor Electronics

Signet 9900 Transmitter

* * Signet 2610 Process Optical Dissolved Oxygen Sensor. Operator's Manual. Introduction. English. System Description.

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Digital flow transmitter for continuous flow measurement

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Signet 9950 Dual Channel Transmitter

Model Sono-Trak Transit Time

User s Guide DPU91 SERIES. Transmitter. Shop online at omega.com For latest product manuals:

Valve Island with Electronic I/O

Ultrasonic level transmitter, non-contact

Signet ph/orp Electrodes General Purpose

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

Digital flowmeter for continuous flow measurement

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Digital flowmeter for continuous flow measurement

MODEL: M2DYS SEN TRONIC AG

Digital flow ELEMENT transmitter for continuous flow measurement

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Digital batch controller

Digital conductivity transmitter

LST400 Ultrasonic level / open channel flow transmitter

Digital flow ELEMENT transmitter for continuous flow measurement

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Preset counters, electronic

ph or ORP Transmitter

To be automatically connected to the nearest North American Technical Sales Office:

Self-Powered Counters H7ET

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

Installation, Operation and Maintenance Manual

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

PROCESS & TEMPERATURE CONTROLLERS

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

UTM10 Series Ultrasonic Transit-time Flowmeters

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

Coils & Electronic Controls

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

OVEN INDUSTRIES, INC. Model 5C7-362

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

FIELD MOUNTED RATE TOTALISER MODEL 202D

1) What meter do I need in this application?

Count/Time Totalizers

SCC-FV01 Frequency Input Module

dtrans Lf 01 µp transmitter / controller for electrolytic conductivity

Current Loop Interface Module M 2025D

Fuzzy Temperature Controllers E5AF

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

GFL-1000 User Manual Ground Fault Locator

Section 11 Electronic Position Controls & Encoders

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

TZIF 4. Current-to-Pulse Converter 10/ EN

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

Signet ph/orp Electrodes

CALYS 50. Field multifunction calibrator for basic use

Local Model. Remote Model FPD1000-A. and FPD1000-TX 4-20 ma Transmitter Local and Remote Models

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Compact Signal Calibrator

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Non-Spring Return DuraDrive Modulating Actuator

Spring Return DuraDrive Proportional Actuator

Dual T/C & RTD Calibrator With Auto Stepping

The transducer component converts the measured signal and displays the actual value.

General-Purpose Photoelectric Sensor

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Ultrasonic Displacement Sensor E4DA

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

INSTALLATION & OPERATION MANUAL MODEL IT375 FIELD MOUNTED RATE INDICATOR AND TOTALIZER

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Self-powered Counter

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

Series 10-ZSE30A(F)/10-ISE30A

Transcription:

Signet 80- Flow *-80.090-* English -80.090- Rev. L 0/ English WARNING! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Specifi cations. Installation. Electrical Connections. Menu Functions Flow:. GPM Flow: 9.7 GPM Signet Flow. Specifications Dimensions 9 mm (.8 in.) Optional Rear Cover 9 mm (. in.) 8 mm (. in.) 9 mm (.8 in.) 9 mm (.8 in.) FRONT VIEW Field Mount & Panel Mount mm (. in.) General Compatibility: Signet Flow Sensors (w/freq out) mm (. in.) 97 mm (.8 in.) SIDE VIEW Panel Mount Enclosure: Case: PBT Panel case gasket: Neoprene Window: Polyurethane coated polycarbonate Keypad: Sealed -key silicone rubber Weight: Approx. g ( oz.) Display: Alphanumeric x LCD Update rate: second Contrast: User selected, levels Accuracy: ± 0.% of reading @ ºC Thermal sensitivity shift: ± 0.00% of reading per ºC Electrical Power: to VDC ±0%, regulated, 00 ma max. Sensor Inputs: Range: 0. to 00 Hz Sensor power: -wire: 0. ma @ VDC ± % - or -wire: 0 ma @ VDC ± % Optically isolated from current loop Short circuit protected 0 mm (.8 in.) SIDE VIEW Field Mount w/ 800 Universal base 0 mm (.0 in.) SIDE VIEW Field Mount w/ 80 Integral kit Current output: to 0 ma, isolated, fully adjustable and reversible Max loop impedance: 0 Ω max. @ V Ω max. @ 8 V 00 Ω max. @ V Update rate: 00 ms Accuracy: ± 0.0 ma Open-collector outputs, optically isolated: 0 ma max. sink, 0 VDC maximum pull-up voltage. Programmable for: High or Low setpoint with adjustable hysteresis Pulse proportional to rate or volume (max 00 pulses/min). Environmental Operating temperature: -0 to 70 C ( to 8 F) Storage temperature: - to 80 C ( to 7 F) Relative humidity: 0 to 9%, non-condensing Maximum altitude: 000 m ( ft) Insulation category: II Pollution degree: Rating: NEMA X/IP front Standards and Approvals: CE, UL listed Immunity & Emissions: EN Manufactured under ISO 900 and ISO 00 China RoHS (Go to www.gfsignet.com for details). Installation ProcessPro transmitters are available in two styles: panel mount and fi eld mount. The panel mount is supplied with the necessary hardware to install the transmitter. This manual includes complete panel mounting instructions. Field mounting requires one of two separate mounting kits. The -80 integral kit joins the sensor and instrument together into a single package. The -800 Universal kit enables the transmitter to be installed virtually anywhere. Detailed instructions for integral mounting or other fi eld installation options are included with the -80 Integral kit or the -800 Universal kit.

. Panel Installation. The panel mount transmitter is designed for installation using a / DIN Punch. For manual panel cutout, an adhesive template is provided as an installation guide. Recommended clearance on all sides between instruments is inch.. Place gasket on instrument, and install in panel.. Slide mounting bracket over back of instrument until quick-clips snap into latches on side of instrument.. To remove, secure instrument temporarily with tape from front or grip from rear of instrument. DO NOT RELEASE. Press quick-clips outward and remove. gasket latch System Pwr Loop - System Pwr Loop panel Output - Output 7 Sensr Gnd Sensr IN Sensr V terminals mounting bracket Panel Mount Installation Detail quick-clips. Electrical Connections Caution: Failure to fully open terminal jaws before removing wire may permanently damage instrument. Wiring Procedure. Remove 0. - 0. in. (- mm) of insulation from wire end.. Press the orange terminal lever downward with a small screwdriver to open terminal jaws.. Insert exposed (non-insulated) wire end in terminal hole until it bottoms out.. Release orange terminal lever to secure wire in place. Gently pull on each wire to ensure a good connection. Wiring Removal Procedure. Press the orange terminal lever downward with a small screwdriver to open terminal jaws.. When fully open, remove wire from terminal. -: Loop Power - VDC ±0% system power and current loop outputs. Max. loop impedance: 0 Ω max. @ V Ω max. @ 8 V 00 Ω max. @ V -: Flow sensor inputs Loop - 0 Output - Snsr Gnd Loop Snsr IN System Pwr Loop - 9 Output Snsr V System Pwr Loop 8 Output - Snsr Gnd AUX Power - AUX Power 7 Output Snsr IN Snsr V and : AUXILIARY power Used only if the fl ow sensor requires more than. ma current. For Signet sensors this is limited to the following products: 000 07 Open-collector Input signals Internal open-collector output circuit S D Isolation Outputs _ 7-0: Open-collector Outputs Two transistor outputs, programmable (see CALIBRATE menu) as: High or Low setpoint with adjustable hysteresis. Pulse based on Volume. Frequency based on fl ow rate. May be disabled (Off) if not used. Signet 80- Flow

. System Power/Loop Connections Stand-alone application, no current loop used Loop - Loop System Power Loop - System Power Loop AUX Power - NC NC Power Supply - VDC AUX Power Connection to a PLC/Recorder, separate supply Connection to a PLC with built-in power supply Loop - Loop System Power Loop - System Power Loop AUX Power - AUX Power PLC or Recorder Channel -0 ma Channel -0 ma Power Supply - VDC Loop - Loop System Power Loop - System Power Loop AUX Power - AUX Power Internal PLC Connection PLC Channel -0 ma Channel -0 ma Power Supply - VDC Example: Two transmitters connected to PLC/Recorder with separate power supply Loop - Loop System Power Loop - System Power Loop AUX Power - AUX Power PLC or Recorder Channel -0 ma in Channel -0 ma in Channel -0 ma in Channel -0 ma in Loop - Loop System Power Loop - System Power Loop AUX Power - AUX Power Power Supply - VDC Auxiliary Power Note: Auxiliary power is necessary for flow sensors that require more than. ma of current. This includes the following Signet flow sensors: 000, 07,, and all Open Collector signal inputs.. Sensor Input Connections Wiring Tips: Do not route sensor cable in conduit containing AC power wiring. Electrical noise may interfere with sensor signal. Routing sensor cable in grounded metal conduit will help prevent electrical noise and mechanical damage. Seal cable entry points to prevent moisture damage. Only one wire should be inserted into a terminal. Splice double wires outside the terminal. Snsr Gnd Snsr IN Snsr V Snsr Gnd Snsr IN Snsr V No Aux Power /-80-XX 00 /-8-XX 0/ Signet 80- Flow Instructions Aux Power Required 000 07 Open-collector input signals Maximum cable length is 0 m (00 ft.) for /80-XX, and any sinusoidal fl ow signal. B Flow Flow:. GPM Flow: 9.7 GPM Maximum cable length is 0 m (000 ft). for /8-XX, 0/ and any open-collector fl ow signal. 80 B A A 00 ft. (0 m) B 00 ft. (0 m) Flow Flow:. GPM Flow: 9.7 GPM A 000 ft. (00 m) B 000 ft. (00 m) A

. Open Collector Output The Open collector output can be used as a switch that responds when the fl ow rate moves above or below a setpoint, or it can be used to generate a pulse that is relative to the fl ow volume or to the fl ow rate. Hysteresis Process Low Output energizes when the fl ow rate is less than the setpoint. The output will de-energize when the fl ow rate moves above the setpoint plus the hysteresis value. Low Setpoint Time High Output energizes when the fl ow rate is greater than the setpoint. The output will de-energize when the fl ow rate drops below the setpoint plus the hysteresis value. Relay energized Relay de-energized Process Frequency Output is a pulse stream that is based on the input fl ow sensor signal. Set for (input frequency = output frequency). Set for even numbers (,,, 8,.... maximum) to scale output frequency. Pulse Output is a pulse based on the volume of fluid that passes the sensor. Set any value from 0.000 to 99999. The output may be disabled (Off) if not used. VIEW menu High Setpoint Hysteresis Time During normal operation, ProcessPro displays the VIEW menu. When editing the CALIBRATE or OPTIONS menus, ProcessPro will return to the VIEW menu if no activity occurs for 0 minutes. To select a VIEW display, press the UP or DOWN arrow keys. The selections will scroll in a continuous loop. Changing the VIEW display does not interrupt system operations. No key code is necessary to change display selection. Output settings cannot be edited from the VIEW menu. Flow:. GPM Flow: 9.7 GPM Signet Flow View Menu Display Flow:. GPM Flow: 7.8 GPM Delta Flow: 0. GPM Description Monitor the flow rate of Channel and Channel simultaneously. This is the permanent view display. Monitor the delta fl ow rate (Channel rate - channel rate = Delta Flow) This is a permanent display. All of the displays below are temporary. After 0 minutes the display returns to the permanent display. Tot: 7.8 Tot:.78 Perm: 7.8 Gallons Monitor channel and channel Resettable Totalizers. Press the RIGHT ARROW key to reset the totalizer. If Reset is locked, you must enter Key Code. Lock or Unlock function is in OPTIONS menu Monitor channel Permanent Totalizer value. Perm:.78 Gallons Loop Output:.00 ma Loop Output:.00 ma Last CAL: 0-0-09 Monitor channel Permanent Totalizer value. Monitor the to 0 ma output for Loop and. Monitor date for scheduled maintenance or date of last calibration. (See description in Calibrate Menu.) Signet 80- Flow

ProcessPro Editing Procedure: Step. Press and hold key: seconds to select the CALIBRATE menu. seconds to select the OPTIONS menu. Step. The Key Code is UP-UP-UP-DOWN keys in sequence. After entering the Key Code, the display will show the fi rst item in the selected menu. Step. Scroll menu with UP or DOWN arrow keys. Step. Press RIGHT ARROW key to select menu item to be edited. The fi rst display element will begin fl ashing. Step. Press UP or DOWN keys to edit the flashing element. RIGHT ARROW key advances the fl ashing element. Step. Press key to save the new setting and return to Step. Notes on Step : The View Menu is normally displayed. The CALIBRATE and OPTIONS menus require a KEY CODE. Notes on Step : If no key is pressed for minutes while display is showing "Enter Key Code", the display will return to the VIEW menu. Press & hold for access: CALIBRATE: ---- Enter Key Code CALIBRATE: *--- Enter Key Code VIEW CALIBRATE s s CALIBRATE: **-- Enter Key Code CALIBRATE: ***- Enter Key Code OPTIONS Flow Units: GPM > First item in CALIBRATE menu Notes on Steps and : Refer to pages and 7 for complete listing of menu items and their use. From the Step display, pressing the UP and DOWN keys simultaneously will return the display to the VIEW menu. If no key is pressed for 0 minutes, display will also return to the VIEW menu. Step : Finished Editing? Press the UP and DOWN keys simultaneously after saving the last setting to return to normal operation. Flow Units: GPM > Step Output Setpnt: 0.0 GPM > Step Notes on Steps and : All output functions remain active during editing. Only the fl ashing element can be edited. RIGHT ARROW key advances the fl ashing element in a continuous loop. Edited value is effective immediately after pressing key. If no key is pressed for 0 minutes unit will restore the last saved value and return to step. Step (pressing key) always returns you to Step. Repeat steps - until all editing is completed. Output Setpnt: 0.00 GPM Output Setpnt: 0.00 GPM Output Setpnt: 0.00 GPM Step Step : Made an Error? Press the UP and DOWN keys simultaneously while any element is fl ashing. This will recall the last saved value of the item being edited and return you to Step. Step Output Setpnt: 9.00 GPM Output Setpnt: 9.00 GPM > Output Setpnt: Saving Signet 80- Flow Instructions

Calibrate Menu Display (Factory settings shown) Flow Units: GPM > Flow K-Factor: 0.000 Total Units: Gallons Total K-Factor 0.000 > Loop Source: Flow > Loop Range: GPM 000.00 00.00 > Output Source: Flow > Output Mode: Low > Output Setpnt: 0.0 GPM > Output Hys:.0 GPM > Output Volume: 00.00 Gallons > Output PlsWdth: 0. Seconds > Output Freq.: Divide by > Last CAL: -0-09 Description The fi rst three characters set the Flow Rate units of measure and have no effect on calculations. They may be any character, upper or lower case. The last character sets the Flow rate Timebase. Select S (seconds), M (minutes), H (hours) or D (days) This setting converts the input frequency from the flow sensor into a fl ow rate. The K-Factor is unique to the sensor model and to the pipe size and schedule. Refer to data in the sensor manual for the correct value. Limits: 0.000 to 99999. (The K-factor cannot be set to 0.) This setting identifies the Totalizer units. It has no effect on any calculation. It serves as a label only. Each character can be any alpha or numeric selection, upper or lower case. This setting converts the input frequency from the flow sensor into a volumetric total. It also is used as the basis for the Open Collector pulse mode. The setting is usually the same as the Flow K-Factor, or different by x0 or x00. Limits: 0.000 to 99999. (Cannot be set to 0.) Select the input source to be associated with Loop output #: Flow sensor #, Flow sensor #, or Delta Flow. Select the minimum and maximum values for the Current loop output #. The 80 will allow any values from 0.0000 to 99999 Select the desired mode of operation for the Open Collector output. Options available are Flow sensor #, Flow sensor #, or Delta Flow. Select the desired mode of operation for the Open Collector output #. Options available are High, Low, volumetric Pulse, or Frequency. The signal may be disabled (Off) if not used. In Low or High Mode, the Open Collector output # will be activated when the Flow rate reaches this value. Be sure to modify this setting if you change the Flow Units. The Open Collector output will be deactivated at Setpoint ± Hysteresis, depending on High or Low Setpoint selection. (See details on page.) In Pulse mode, the Open collector output # will generate one pulse when this volume of fl ow passes the sensor. The measurement is based on the Total K-Factor. The 80 will allow any value from 0.000 to 99999. In Pulse mode, this setting defi nes the duration of the Open Collector output pulse. The 80 allows any value from 0. seconds to 999.9 seconds. In Frequency mode, the Open Collector output will simulate the sensor frequency, divided by this setting. Set for (input frequency = output frequency). Set for even numbers (,,, 8... max) to scale output frequency. Use this note pad to record important dates, such as annual recertifi cation or scheduled maintenance. All functions labeled "" will repeat for channel. Signet 80- Flow

Options Menu Display (Factory settings shown) Contrast: > Flow Decimal *****. > Total Decimal ******.** > Averaging : Off > Sensitivity : 0 > Total Reset Lock Off > Loop Adjust.00 ma > Loop Adjust 0.00 ma > Output Active Low > Description Adjust the LCD contrast for best viewing. A setting of is lowest contrast, is highest. Select lower contrast if the display is in warmer ambient surroundings. Set the decimal to the best resolution for your application. The display will automatically scale up to this resolution. Select *****., ****.*, ***.**, **.*** or *.**** Set the totalizer decimal to the best resolution for your application. Select ********., *******.*, or ******.** OFF provides the quickest output response to changes in fl ow. Longer averaging period produces more stable display and output response. Select OFF, 8 s, 0 s, 0 s or 0 s. Sensitivity works in conjunction with Averaging to balance response time with signal stability. Selections are 0 to 9. Select 0 (zero) for the minimum sensitivity, or 9 for the maximum sensitivity. The function is described below. Lock Off : No key code required to reset the resettable totalizer. Lock On : The Key Code must be entered to reset the resettable totalizer. Adjust the minimum and maximum current output. Use this setting to match the system output to any external device. The display value represents the precise current output. Adjustment limits:.80 ma <.00 ma >.00 ma 9.00 ma < 0.00 ma >.00 ma Active HIGH: This setting is used to turn a device (pump, valve) ON at the setpoint. Active LOW: This setting is used to turn a device OFF at the setpoint. Test Loop: Test Output : > > Press UP or DOWN keys to manually order any output current value from. ma to.00 ma to test current loop output. Press UP or DOWN keys to manually toggle the state of open collector output. All functions labeled "" will repeat for channel. No AVERAGING, no SENSITIVITY With AVERAGING set to 0 (zero) and with SENSITIVITY set to zero, the 80 responds to every unstable shift in the fl ow. The dashed red line represents the actual output of the fl ow sensor in unstable fl ow conditions. AVERAGING only With AVERAGING set to 0 seconds and SENSITIVITY still set to zero the fl ow rate is stabilized, but a sharp change in fl ow rate is not represented for 0 seconds or longer. (dotted green line). AVERAGING and SENSITIVITY With AVERAGING at 0 seconds and SENSITIVITY set to OR, the fl ow rate is stabilized, while the sudden shift in fl ow is refl ected very quickly. (Solid blue line) s 0 s 0 s 0 s 0 s 0 s 0 s 70 s NOTE: The SENSITIVITY function is ineffective if the AVERAGING function is set to zero (seconds). Signet 80- Flow Instructions 7

Troubleshooting Display Condition Possible Causes Suggested Solutions - - - - - Flow rate exceeds display capability Increase Flow units time base Move fl ow decimal one place to the right Pulse Overrun Open Collector pulse rate exceeds maximum of 00 pulses per minute. Pulse width set too wide. Increase Pulse volume setting Decrease pulse width setting. Reduce system fl ow rate Value must be more than 0 K-Factors cannot be set to 0. Enter K-Factor from 0.000 to 99999 Open Collector is always activated Hysteresis value too large Defective transmitter Change the hysteresis value Replace transmitter Ordering Information Mfr. Part No. Code Description -80-9 000 07 Flow transmitter, Field mount -80-P 9 000 08 Flow transmitter, Panel mount -80-9 000 09 Flow transmitter, Field mount with relays -80-P 9 000 00 Flow transmitter, Panel mount with relays -80-9 000 0 Flow transmitter, Field mount with dual input/output -80-P 9 000 0 Flow transmitter, Panel mount with dual input/output Accessories Mfr. Part No. Code Description -800 9 000 8 Universal mounting kit -80 9 000 87 Flow Integral Mnt NPT -800.9 9 000 8 Splashproof rear cover -800.9 9 000 7 RC Filter kit (for relay use) -0000.9 9 000 Heavy duty wall mount bracket -000.98 98 80 Surface Mount Bracket -000.99 98 80 x inch adapter plate for Signet retrofi t -9000.9 9 000 8 Liquid tight connector kit for rear cover (includes connectors) -9000.9-9 000 89 Liquid tight connector kit, NPT ( piece) -9000.9-9 000 8 Liquid tight connector kit, PG. ( piece) 700-7 9 000 87 VDC Power Supply 7. W, 00mA 700-9 000 88 VDC Power Supply W, 00mA 700-0 9 000 89 VDC Power Supply 0 W,. A 700-0 9 000 90 VDC Power Supply 0 W,. A 700-0 9 000 9 VDC Power Supply 00 W,. A Georg Fischer Signet LLC, 0 Aerojet Avenue, El Monte, CA 97-88 U.S.A. Tel. () 7-770 Fax () 7-07 For Worldwide Sales and Service, visit our website: www.gfsignet.com Or call (in the U.S.): (800) 8-090 For the most up-to-date information, please refer to our website at www.gfsignet.com -80.090- Rev. L 0/ English George Fischer Signet, Inc. 0