MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Similar documents
MODEL: M2XU MODEL: M2XU [1][2] [3][4]

MODEL: M1EXT. with Display M1E Series

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: R30US4. Remote I/O R30 Series

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: W2TS. Mini-MW Series

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M3LU. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

MODEL: RZMS-U9. PC Recorders RZMS Series

MODEL: JB2. Plug-in Signal Conditioners M-UNIT

MODEL: KS. Plug-in Signal Conditioners K-UNIT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: TC10EM. Temperature Controller TC10 Series

MODEL: AS4V. Plug-in Signal Conditioners M-UNIT

MODEL: JPR2. Plug-in Signal Conditioners M-UNIT

MODEL: R3-RS8A. Remote I/O R3 Series. RTD INPUT MODULE (high accuracy, 8 points, isolated) MODEL: R3-RS8A[1][2]

MODEL: WL40MW1F. Wireless I/O WL40F Series

MODEL: 27HU 27-UNIT MODEL: 27HU [1][2]

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: 47LV. Digital Panel Meters 47 Series

MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC

MODEL: DLS. Telemetering System

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

MODEL: M2DYS SEN TRONIC AG

MODEL: DAST-20. Telemetering System

[3] MOUNTING DIRECTION

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

RZUS-U9 PC RECORDER MODEL. PC Recorders RZUS Series. (universal input, 12 points; isolated; bus-powered USB) MODEL & SUFFIX CODE SELECTION

DISCRETE INPUT MODULE, 16 points

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)

CompoBus/D-type Digital Controller

CompoNet Gateway Unit for CC-Link

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: MRP6. Final Control Elements

MODEL: 48NDVD. Bargraph Indicators 48N Series

SHIMADEN DIGITAL INDICATORS

Multi-point Temperature Controller

SHIMADEN DIGITAL INDICATOR

MODEL: 48NDV. Bargraph Indicators 48N Series

SHIMADEN DIGITAL INDICATORS

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

MODEL: 48NAV. Bargraph Indicators 48N Series. [3] MOUNTING DIRECTION V: Vertical H: Horizontal

DIGITAL PROGRAM CONTROLLER

Status Indicator LED PWR LINK COL

General Specifications

Assembly. Front view. Parametrization interface. Power Bus

onlinecomponents.com

SHIMADEN PROGRAM CONTROLLER

Resistance Temperature Device Conversion Module

MODEL: SC110. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel, MV output backup) MODEL: SC110 [1]0 [2][3]

USB-2404-UI Specifications

NPN TRANSISTOR OUTPUT MODULE

JPQ2 PULSE ACCUMULATOR

General Specifications

Remote Sensor Amplifier Terminal

VersaPoint I/O Module

Temperature Controllers E5 J

Fuzzy Temperature Controllers E5AF

General Specifications

General Specifications

Model 6517B Electrometer / High Resistance Meter Specifications

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

MODEL: R3-WT4B. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

DIGITAL INDICATOR CC-Link Interface CSD Instruction Manual

Analogue temperature controllers

General Specifications

General Specifications

P5201 Universal Programmable Transmitters with Galvanic Isolation

Remote Sensor Amplifier Terminal

FC-33, DC SELECTABLE SIGNAL CONDITIONER

INSTALLATION MANUAL. SENECA s.r.l. Via Germania, Z.I. CAMIN PADOVA ITALY Tel Fax

DATA SHEET. CIO multi-inputs. CAN bus-based I/O module

INSTRUCTION SHEET. Eaton Logic Controller ELCM TC Temperature Modules. [Applicable Temperature modules] ELCM-TC04ANNN MTN1

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

PROGRAMMABLE CONTROLLER

General Specifications

I-2533CS series User Manual

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

General Specifications

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

DIGITAL THERMOMETER VIEW RECORDERS Digital Thermometer FEATURES

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Uni-Mux XQL Multi-Channel Data Acquisition Module

Management number : BAP-C CC-Link Partner Association

USER MANUAL Z-8TC. Via Germania, Z.I. CAMIN PADOVA ITALY. Via Svizzera, Z.I. CAMIN PADOVA ITALY

Process displays For standard signals, temperature, resistance measurement

DIGITAL THERMOMETER Digital Thermometer FEATURES INDEX RECORDERS

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Transcription:

Remote I/O R1X Series THERMOCOUPLE & DC INPUT MODULE (16 points; CC-Link Ver.1.1/Ver.2.) Functions & Features 16-point thermocouple or DC inputs CC-Link interface CC-Link Version 1.1 and 2. can be switched at the startup 175 (6.89) 115 (4.53) 4 (1.57) mm (inch) 2T-[1][2] ORDERING INFORMATION Code number: R1C-GH2T-[1][2] Specify a code from below for each [1] and [2]. (e.g. R1C-GH2T-M2/Q) Specify the specification for option code /Q (e.g. /C1) Use Ordering Information Sheet (No. ESU-5956). Default setting will be used if not otherwise specified. Facry default setting Input type: DC Voltage ±5 V Burnout protection: No burnout Cold junction compensation: No FIELD TERMINAL TYPE T: M3 screw terminals [1] POWER INPUT AC Power M2: 1 24 V AC (Operational voltage range 85 264 V, 47 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±1 %, ripple 1 %p-p max.) [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer M-System's web site.) /C1: Silicone coating /C2: Polyurethane coating /C3: Rubber coating RELATED PRODUCTS Resisr module (model: REM3-25) R1X configurar software (model: R1CON) Downloadable at M-System s web site. A dedicated cable is required connect the module the PC. Please refer the internet software download site or the users manual for the PC configurar for applicable cable types. PACKAGE INCLUDES... Terminating resisr (11 Ω,.5 W) GENERAL SPECIFICATIONS Connection Power input, CC-Link: Euro type connecr terminal (applicable wire size:.2 2.5 mm 2 (AWG24 12), stripped length 7 mm) Input: M3 screw terminals (rque.6 N m) Configurar: 2.5 dia. miniature jack; RS-2-C level Screw terminal: Nickel-plated steel Housing material: Flame-resistant resin (gray) Isolation: Input CC-Link (FG) power PWR indicar: Green LED blinks in normal conditions. CC-Link COMMUNICATION Procol: CC-Link V1.1 / V 2. Cable for comm. link: Specified by Mitsubishi Electric Required nodes V. 1.1: 4 V. 2.: 1 (cyclic expansion: 4) Station No. setting: Rotary switch V. 1.1: Rotary switch; 1 61 V. 2.: Rotary switch; 1 64 Baud rate setting: Rotary switch L RUN indicar: Red LED turns on in normal conditions. L ERR. indicar: Red LED turns on or blinks in an abnormality. SD indicar: Red LED turns on when transmitting. RD indicar: Red LED turns on when receiving. INPUT SPECIFICATIONS Thermocouple or DC input, 16 points (Common negative for DC input) Measuring range ±2 V, ±5 V, ±1 V: Atten. SW ON (3) R1C-GH SPECIFICATIONS ES-5956 Rev.12 Page 1/5

Measuring range ±.8 V, ±.2 V, ±5 mv, ±1m V: Atten. SW OFF (1) Input resistance: 3 kω Thermocouple types: PR, K, E, J, T, B, R, S, C, N, U, L, P Sampling rate: 15 millisec./16 points A/D conversion output: 16-bit signed binary (negative range represented by 2 s complements) Engineering unit value is converted in A/D conversion data as shown below. Input type & range: A/D data (decimal) ±2 V: ±2 ±5 V: ±5 ±1 V: ±1 ±.8 V: ±8 ±.2 V: ±2 ±5 mv: ±5 ±1 mv: ±1 Thermocouples: Temperature 1 In order change input type and range after shipment, the R1X configurar software (model: R1CON) is required. CC-Link version selecr input: Ver. 1.1 with OFF at the startup. Ver. 2. with ON at the startup. Dry contact input (ON at detect. level 1.5 V) Sensing: approx. 5 V DC, 1 ma Valid only at the moment of the power supplied the module. Firmware version B. or higher required. Confirm the firmware version using the R1X configurar software (model: R1CON) or consult M-System. A/D CONVERSION DATA RWr n RWr n1 RWr n2 15 14 13 12 11 1 9 8 7 INPUT 1 A/D CONVERSION DATA INPUT 2 A/D CONVERSION DATA INPUT 3 A/D CONVERSION DATA 6 5 4 3 2 1 INSTALLATION Power consumption AC: Approx. 1 VA DC: Approx. 7 W Operating temperature: -5 6 C (23 14 F) Operating humidity: 3 9 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 4 g (.88 lb) PERFORMANCE (% of measuring range) Accuracy DC input: ±.3 % Thermocouple input: See the table on the end of this section. Cold junction compensation error: ±3 C or ±5.4 F max. (at 2 C ±1 C or 68 F ±18 F) Temp. coefficient: ±.15 %/ C (±.8 %/ F) ±.5 %/ C (±.3 %/ F) for 1 mv range and T/C B (RH) Insulation resistance: 1 MΩ with 5 V DC Dielectric strength: 2 V AC @ 1 minute (input CC-Link [FG] power ground [FG1]) Thermocouple Accuracy T/C (PR) K (CA) E (CRC) J (IC) T (CC) B (RH) R S C (WRe 5-26) N U L P (Platinel II) USABLE RANGE ( C) -27 177 137-27 1-21 12-27 4 1 182-5 -5-27 -2-2 176 176 2 13 6 9 1395 ACCURACY (%) ±.5 ±.3 ±.7 ±.7 ±1. ±.7 ±.7 ±.7 ±.7 ±.5 ±.5 ±.3 ±.5 CONFORMANCE RANGE ( C) 4 177 137 1 12 4 7 182 4 4 176 176 2 13 6 9 1395 RWr n3 RWr n7 RWr n11 RWr n15 INPUT 4 A/D CONVERSION DATA INPUT 8 A/D CONVERSION DATA INPUT 12 A/D CONVERSION DATA INPUT 16 A/D CONVERSION DATA T/C (PR) K (CA) E (CRC) J (IC) T (CC) B (RH) R S C (WRe 5-26) N U L P (Platinel II) USABLE RANGE ( F) -454 18 2498-454 18-346 2192-454 212 338-58 -58-454 -8-8 428 2372 1112 1652 1395 Note: CJC error is not included. ACCURACY (%) ±.5 ±.3 ±.7 ±.7 ±1. ±.7 ±.7 ±.7 ±.7 ±.5 ±.5 ±.3 ±.5 CONFORMANCE RANGE ( F) 18 2498 18 2192 1292 338 428 2372 1112 1652 1395 R1C-GH SPECIFICATIONS ES-5956 Rev.12 Page 2/5

EXTERNAL VIEW A B C D E F G T8 T7 T6 DA DB DG FG SLD NAME A Power terminal block For power input B Network terminal block For wiring CC-Link SETTING BAUD RATE C Baud rate setting 156 kbps (facry default) 1 625 kbps 2 2.5 Mbps 3 5 Mbps 4 1 Mbps Other than 4 Not valid; L ERR. turns on as a transmission error. D Station No. setting V. 1.1: Selectable within 1 61. (facry set : ) V. 2.: Selectable within 1 64. (facry set : ) ID (color) E Status indicar LED L RUN (red) ON: Normal communication blinking: Transmission data error OFF: Communication down (time-out error) L ERR. (red) ON: Transmission data error blinking: Transmission data error OFF: Normal transmission SD (red) RD (red) ID (color) ON when transmitting ON when receiving F Power LED PWR (green) ON: Abnormality blinking, high speed: CC-Link Ver. 1.1 blinking, low speed: CC-Link Ver. 2. Master Version 2. with long ON time Master Version 1.1 with long OFF time G Configurar jack 2.5 dia. miniature jack; RS-2-C level R1C-GH SPECIFICATIONS ES-5956 Rev.12 Page 3/5

CONNECTION DIAGRAM DC INPUT INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 INPUT 9 INPUT 1 INPUT 11 INPUT 12 INPUT 13 INPUT 14 INPUT 15 INPUT 16 T/C INPUT ext. wire CJC Sensor CC-Link VERSION SELECTOR INPUT 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 31 33 34 35 36 Comm. Power Input DA DB DG SLD FG T6 T7 T8 JACK To Other CC-Link Devices U () V () FG1 POWER CONFIGURATOR Note 1: This device is not designed cancel noise included in the input signals. Be careful eliminate such noise by using shielded cables. Note 2: Be sure maintain the same potential at all the common negative terminals for DC input. Note 3: CC-Link version selecr input is valid only at the moment of the power turned on. Firmware version B. or higher. Use the R1X Configurar Software (model: R1CON) or consult M-System confirm the firmware version. Caution: FG1 terminal is NOT a protective conducr terminal. R1C-GH SPECIFICATIONS ES-5956 Rev.12 Page 4/5

EXTERNAL DIMENSIONS & TERMINAL ASMENTS unit: mm (inch) 175 (6.89) 1 (.39) 165 (6.5) 35 (.2) dia. MTG HOLES 15.5 (.61) 46 (1.81) 15 (4.13) 14 (4.9) DIN RAIL 35 mm wide 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 22 23 24 25 26 27 28 29 3 31 33 34 35 35 14 (.55) 163 (6.42) FOR WALL MOUNT. 8 (.31) CJC SENSOR (model: CJM) 3 (.12) 4 (1.57) [6 (.24)] 6.2 (.24) 36M3 INPUT TERMINALS Specifications are subject change without notice. R1C-GH SPECIFICATIONS ES-5956 Rev.12 Page 5/5