NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x G TIMER OUTPUTS INTRODUCTION SPECIFICATIONS AUXILIARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

Similar documents
NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x A INTRODUCTION TIMER OUTPUTS SPECIFICATIONS AUXILARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

N1040T Controller. TEMPERATURE CONTROLLER AND TIME INSTRUCTIONS MANUAL V2.1x A SAFETY ALERTS FEATURES INSTALLATION / CONECTIONS

Operating Instructions for SymCom s INFORMER MS EDITION DIAGNOSTIC TOOL

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

PROGRAMMABLE DIGITAL TIMER ELIRO (33 Functions): V7DFTS3

Solid-State Digital Counter H7AN

Electronic timers CT-S range Selection and ordering details

Fuzzy Temperature Controllers E5AF

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Proximity Sensor Terminology

PROXIMITY SENSOR TERMINOLOGY

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

J K T E N R S B Pt Mv Linear 0 5 V Linear 0-10 V Linear 0 50 mv No Linear 0 5 V No Linear 0-10 V No Linear.

Using the G8 TM Game Timer for Timing Advanced Are You A Werewolf? games

DESCRIPTION NOTE. Power Supply MODEL 2200A PM

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

CURRENT/FREQUENCY CONVERTER S 104

For more information on these functions and others please refer to the PRONET-E User s Manual.

MotStart Three-phase Start-Up Supervision for Motors

MicroManager. Torque Mode CTCW/Loadcell Control. Instruction Manual MM3000-CTCW

Beyond AMI. We Put You in Control When It Counts

Position Indicator with/without Limit Values

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Controller N3000. UNIVERSAL PROCESS CONTROLLER INSTRUCTIONS MANUAL V2.1x A SAFETY SUMMARY CONFIGURATION INTRODUCTION

Simplified Operations for TM-3100 Series Digital Tachometer

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

OptiLogic Series. Input/Output Modules. Optimal Automation for Industry. Optimation, Inc. (256)

APPENDIX APPENDIX A 1

Operating Instructions

Pulse Scaler for DIN Rail Attachment

Safety Relay Unit. OFF-delay time

in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT

INSTRUCTION MANUAL G EN1000/EN1001 CASCADE/MULTI-VALVE SERIES CONTROLS

INSTALLATION INSTRUCTIONS FOR SYMCOM S MODEL 77C-LR-KW/HP ELECTRONIC OVERLOAD RELAY

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

OVEN INDUSTRIES, INC. Model 5C7-362

Installation, Operation and Maintenance Manual

Power connections, minimum and maximum wiring capabilities, tightening torque

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

S662 Preset Batch/Dual Counter

FEATURES OPTIONAL FEATURES

Solid-state Timer H3DS

MasterINTERFACE 39 Series - Relay interface modules

WHEN A PLC IS TOO MUCH, AND SPACE FOR

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

MasterINTERFACE 39 Series - Relay interface modules

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

g GE POWER MANAGEMENT

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

Operation Manual February Opticom Infrared System

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Series BDF for Process

GEMINI 1000/ DIGIT PRESETTABLE COUNTERS OR RATE INDICATORS GEMINI SINGLE LEVEL & GEMINI DUAL LEVEL w/optional 20 ma CURRENT LOOP

N2020 Controller. TEMPERATURE CONTROLLER INSTRUCIONS MANUAL V1.0x C SAFETY ALERTS FEATURES INSTALLATION / CONNECTIONS

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

Rotational speed controller

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

DESCRIPTION NOTE MODEL 2200VM

VTSC100. Transfer Switch Controller

MODEL 421 Over/Under Motor Load Monitor

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

RSMFX-2R MULTIFUNCTIONAL

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

SENSORS S62. Compact Sensors - S62. The most complete universal sensor in a compact 50x50 mm housing. Sensors with red, infrared LED or LASER emission

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

MicroManager. Velocity Mode PID Dancer/Loadcell Control. Instruction Manual MM3000-PID

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

Series LC8. Positioning Driver/For AC Servomotor. Compliant actuators/series LJ1, Series LG1, Series LTF

MODEL P-1400 OPERATION MANUAL. Four Loop Inputs, Two Vital Outputs, and One Vital Input

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Temperature Controllers E5 J

354B SERIES SHAWNEE II High Speed Predetermining

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

S663 Preset Rate/Totalizer Counter

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

Quick Reference Guide

PRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY

Signet Flow Transmitter

N2000S UNIVERSAL PROCESS CONTROLLER FOR SERVO POSITIONING OPERATING MANUAL. (Manual Key): toggles the AUTO/MANUAL mode.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC

Multifunctional counter tico 772/773/774

HC900 Hybrid Controller

DIGEM f 96 x 48 EK. Applications. Description

362 Umbilo Road, Durban 4001, P.O Box 17211, Congella 4013, Tel: /8, Fax: Website:

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

U-GAGE Q45U Long-Range Ultrasonic Sensors

Data Acquisition Modules/ Distributed IO Modules

Transcription:

NT240 TIMER PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x G INTRODUCTION The NT240 is a programmable timer designed to monitor time intervals, activating its outputs according to some predefined mode of operation and time intervals chosen by the user. The user can also create its own mode of operation to best fit his application. The timer shows the elapsed time in an increasing or decreasing mode, with resolutions from 0.01 s to 1 hour. Digital inputs are available to perform specific functions. Standard outputs are relay and logic pulse (5 V) types. SPECIFICATIONS Input types: - NPN/PNP sensors - NO/NC dry contact - Voltage: Logic level 1: 5 to 30 Vdc Logic level 0: -0.5 to 0.5 Vdc Output: - 1 SPST Relay 3 A / 250 Vac (3 A / 30 Vdc) - 1 voltage pulse 5 V / 25 ma Time delay after turning on the timer: 200 ms Accuracy: 0.1 % of displayed time Response time: 10 ms for the relay output and 0.3 ms for the pulse output Auxiliary voltage source: 12 Vdc ±10 % / 50 ma : 100 to 240 Vac/dc (±10 %), 50/60 Hz or optional 24 V: 12 to 24 Vdc / 24 Vac (-10 % / 20 %) Maximum consumption: 3 VA Operating environment: 0 to 55 ºC, Relative humidity (maximum): 80 % up to 30 ºC. For temperatures above 30 ºC, decrease 3 % per ºC. Dimensions: 48 x 48 x 106 mm Cut for panel fixation: 45.5 to 45.5 mm Approximate weight: 150 g TIMER OUTPUTS The timer provides an output, called TIMER OUTPUT, which can be activated in various ways according to the selected temporization mode. This output is available as a relay contact and as a voltage pulse (both operate simultaneously). Output types: 1 SPST 3 A / 250 Vac relay, terminal 3 and 4; Output delay time: 1 voltage pulse of 5 V / 25 ma, terminals 5 and 6 10 ms for relay output; 0.3 ms for pulse output. The 0Per parameter defines the way the output will operate. AUXILIARY SUPPLY OUTPUT A 12 Vdc 10 % (50 ma max) auxiliary power supply is provided on terminals 7 and 8 to power electronic sensors used as inputs to the timer. The (-) supply terminal is wired internally to the GND terminal of the inputs (the supply is not electrically isolated from the inputs). INSTALLATION Panel Mounting Insert the unit into the panel cut-out (use the dimensions specified in the "Technical Specifications" section) and slide the mounting clamp from the rear to a firm grip at the panel. The timer circuitry can removed from its case from the front, without the need of disassembling the instrument from the panel, leaving the wire connections intact. Electric connections Figure 01 shows the timer terminals along with theirs functions. TIMER INPUTS The timer has three control inputs: START, HOLD and RESET. These inputs can be configured to accept four different electrical (logical) signals (see parameter PnP in the configuration). The signal type there defined becomes the same for all three inputs. START: s time counting The start input, when activated, starts the temporization cycle, using the operating mode selected in the configuration. The START input is available on terminals 9 and 12. HOLD: Interrupts time counting The HOLD input, while active, interrupts time counting. When the HOLD input is released, the time counting resumes from the point it was interrupted. NOTE: The HOLD function can activated by the F key, when programmed to perform as such on the F Fv parameter of the timer. Using the F key as the input to HOLD function, pressing once stops the timer and pressing again resumes the counting of time. RESET: Timer Input The input, when activated, cancels the current temporization and returns the timer display to the initial value. While is active, the temporization can not be started. When is released, the timer becomes available for new temporization. Figure 01 Timer connections panel Recommendations for Installation NOVUS AUTOMATION 1/5 Input signal wires should be laid out away from power lines and preferably inside grounded conduits. Instrument mains should be suitable for this purpose and wires should not be shared with high consumption motors and inductors. Use of RC filters (47 and 100 nf) in parallel with solenoids and contactor coils are highly recommended. In monitoring and control applications it is essential to consider what can happen when any part of the system is subject to failure.

Connections of the input signals The type of signal to be applied to the inputs is determined by the user in the PnP parameter of the timer. The signal type must be the same for the three inputs (, Hold and ). Sensors with NPN/PNP open collector output: Common to most proximity sensors, must be connected as indicated in Figure 02. The PnP parameter must be set to 0 for NPN sensor output and to 1 for PNP. Levels structure: 1 Indication of elapsed time Shown on power-up; 2 Setpoint level (temporization setpoints) To enter, press P for 4 seconds; 3 Configuration level. Press P for 8 seconds; 4 Custom Operating mode level. Press P for 12 seconds; Figure 02 Connecting PNP/NPN type sensor - Signal from relay or switch (dry contact): Wire dry contacts as shown on Figure 03. For this type of input, configure PNP = 0. To enter into deeper levels, press the P for the time required by the level and when the timer shows the first parameter of that level, simply release the P key to stay in that level. Other parameters in that level are accessed by pressing the P key. To modify the value of a parameter use the and keys for incrementing or decrementing the value, respectively. After the last parameter of the cycle is reached, the timer returns the main screen (Indication of Elapsed time). The modified values are stored in a non-volatile memory when the P key is pressed to move to the next parameter. Figure 03 - Connecting dry contact (relay, switch key) - Voltage input signal Refer to the Specifications section for the input voltage levels compatible with the timer. Figure 04 shows the wiring scheme. When PNP = 1, the timer recognizes the rising edge of the pulse For the recognition of the falling edge, set PnP = 0. PROGRAM SECURITY To avoid tampering, parameter Prot and a hardware jumper can be used to disable access to programming parameters. With the jumper in the OFF position, all program levels are unprotected. The Prot parameter can only be changed with the jumper in the OFF position. With the jumper in the ON position or removed, the protection level is defined by the current value of the Prot parameter: 0 No protection. All parameters can be accessed; 1 No access to Operating mode level. 2 No access to Operating mode level and Configuration level. 3 Full protection. OFF Figure 2 Protection Disabled ON Figure 3 Protection Enabled OPERATION Figure 04 - Connection for pulse input. Following power-on, the timer shows the main screen (Time) and will remain in this screen in normal operation. For configuring the timer, it is necessary to set proper values to the various internal parameters. The parameters are organized in three levels. To enter these levels, one must press the P key for defined intervals of time, as shown below. Temporization Setpoints Level T1.sp Timer 1 SetPoint 0v1.t Output 1 Time Timer Setpoint: It defines the total time to be counted by the timer. In up counting, the timer counts from zero to the value programmed in. In countdown, the timer counts from the value programmed in to zero. Output temporization: Defines the interval of time the output is to remain active after the time programmed in has elapsed (parameter T1.S4 shall be set to 1 output turns off after output temporization). During the output temporization the relays are maintained active while the corresponding LEDs blink to indicate the output temporization is taking place. NOVUS AUTOMATION 2/5

Configuration level 0PEr Operation Mode 1.rA T1.uP F Fu PnP Ov1.r Prot The NT240 has 11 pre-defined operating modes plus the possibility for the user to create his own customized mode. The operation modes are described with further details in the section "Timer Operation Modes". 0 Delayed output following power on 1 Delayed pulse after power on 2 Pulse on power on 3 Cyclic after power on 4 Pulse after momentary input signal 5 Extended pulse after release of the input signal 6 Delayed output after momentary signal in the input 7 Delayed pulse after momentary signal in the input 8 Pulse after continuous signal in the input 9 Delayed output following continuous input signal 10 Delayed pulse after continuous input signal 11 Special mode defined by the user Temporization ranges: sets the interval range to be used by the timer, as below: 0: 99.99 s 4: 9999 min 1: 999.9 s 5: 99 h 59 min 2: 9999 s 6: 9999 h 3: 99 min 59 s Defines the count mode presentation to the display: 0: down counting 1: up counting Function of the front panel F key: 0: The F key is not used; 1: s time counting; 2: and Hold Restarts or pauses time counting. The key function depends on operation mode chosen for the timer, as described in the section "Timer Operation Modes". Defines the type of the signal to be applied to the timer input. 0: Sensor with open collector NPN output or dry contact; Sensor with open collector PNP output or logical DC pulse Output temporization range, to be used by the 0u1.t parameter. 0: 99.99 s 4: 9999 min 1: 999.9 s 5: 99 h 59 min 2: 9999 s 6: 9999 h 3: 99 min 59 s PROTECTION OF PARAMETERS: Defines the level of protection for the parameters. Configure this parameter prior to removing the protection jumper. See manual item Program Security. t1.s1 t1.s2 t1.s3 t1.s4 T1.S5 Temporization. This parameter defines when the temporization should be initiated: 0 : On timer power-up. 1 : Upon input activation (leading edge of the input). 2 : Upon input being released (trailing edge of the input) 3 : input leading edge only when the output is off 4 : input trailing edge only when the output is off 5 : Through the F key. The Function programmed for the F key must be and Hold (FFv = 2). Defines the timer action when the start input is activated during the temporization: 0 : Restarts temporization 1 : Disregard the input when the temporization is in progress 2 : Interrupts temporization. This parameter defines the moment the output is to be activated: 0: At the leading edge of the input signal. 1: At the trailing edge of the input signal. 2: At the beginning of the temporization. 3: At the end of the temporization. This parameter defines how the output is to be turned off: 0: At the end of the programmed time interval; 1: After the output temporization, as defined in ou1.t; 2: Only by the command. The can be accomplished either by the input of by the F key programmed with function (FFv = 1). Automatic temporization restart. Allows cyclical temporization, according to the values below: 0: No automatic restart. 1: Restart at the end of the temporization (as defined in ). 2: Restart after the end of the output temporization ( + 0vt.1) PARAMETER CHANGE WHILE TEMPORIZATION IS IN PROGRESS When a parameter in the programming cycles of the timer is modified by the user, the temporization in progress is interrupted and the timer reset. Do not change timer configuration while the temporization is performing critical functions, as the outputs may be turned on and off at improper moments. Custom Operating Mode Level The parameters in the Custom Operating Mode level are automatically set by the timer when a predefined operating mode is selected (0PEr = 0 to 10). The parameters below are used when the user needs to customized the timer to a particular mode of operation (0PEr = 11). NOVUS AUTOMATION 3/5

TIMER OPERATING MODES Mode 4 Pulse after momentary signal The timer offers 11 predefined operating modes plus the possibility for the user to customize his own mode of operation, by configuring parameters t1.s1 to t1.s5. Modes 0 to 10 are the predefined ones, whereas mode 11 left to the user control. They are described below: Mode 0 Delayed activation after power-up 1 1 2 0 0 The F key can be programmed as /Hold. Mode 5 Extended pulse after output is turned off 0 0 3 2 0 The F key can be programmed either as or /Hold. Mode 1 Delayed pulse after power-up ou1.t 2 1 0 0 1 The F key can be programmed as /Hold. 0 0 3 1 0 The F key can be programmed either as or /Hold. Mode 2 Pulse at power-up Mode 6 Delayed output after momentary START signal 1 1 3 2 0 The F key can be programmed as /Hold. Mode 7 Delayed pulse after momentary START signal 0 0 2 0 0 ou1.t ou1.t The F key can be programmed either as or /Hold. Mode 3 Cyclic after power-up 3 1 3 1 0 ou1.t ou1.t The F key can be programmed as /Hold. 0 0 3 1 2 The F key can be programmed either as or Hold. NOVUS AUTOMATION 4/5

Mode 8 Pulse after a continuous START signal IDENTIFICATION In order to identify your model of NT240, check the name in the device label: Example: 1 2 2 0 0 The F key can only be used for holding the temporization in NT240 - RP - 24V A: Model NT240 A B C B: Optional RP (version with OUT1: Pulse and Relay) C: Supply Blank (basic version, with power supply 100 to 240 Vac/dc) 24V (version with power supply 12 to 24 Vdc / 24 Vac) Mode 9 Delayed output after a continuous START signal WARRANTY Warranty conditions are available on our website www.novusautomation.com/warranty. 1 2 3 2 0 The F key can only be used for holding the temporization in Mode 10 Delayed pulse after continuous START signal ou1.t 1 2 3 1 0 The F key can only be used for holding the temporization in Mode 11 Customized Mode of Operation In this mode, the operator is allowed to create his own mode of operation if the predefined ones don t meet the process needs. This can be accomplished through parameters t1.s1 to t1.s5 in the Custom Operating Mode level of parameters. The user must analyze each one of the 5 parameters and understand the effect that each one has on the timer. The user must consider that not all the combinations of the parameters t1.s1 to t1.s5 are valid, and that some combinations may lead to unexpected behaviors. When programming a customized operation mode, the user must test it to verify that it suits the application before incorporating it to the system. NOVUS AUTOMATION 5/5