RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Technical Data Sheet

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Digital Multifunction Instrument - Rish Master 3440

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Data Sheet. RISH Master Record %THD

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Technical Data Sheet AMIK 300 / 301

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Alpha 50. Technical Data Sheet. Special Features

AMIK 200 / 201 Technical Data Sheet

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RS Pro ENGLISH. Datasheet

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

RS Pro ENGLISH. Datasheet

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Jewell DPM EINE BEST IN CLASS

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

AMIK Three Phase Digital Panel Meters

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Theta 20A / 20V. Technical Data Sheet. Special Features

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Integra 1560 and 1580 Digital Transducer Systems

Programmable DPM RISH EINE

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Operating Guide October 2006

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Theta Hz. Technical Data Sheet. Special Features

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Application: Salient Features: Products Features:

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Centrale de mesure Power Meter PM500 Merlin Gerin

Power Meter Series PM3200 Functions and characteristics

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Introduction DIN rail mounted electricity meters

Energy Management Energy Meter GM3D

Energy Management Energy Meter Type EM110

Energy Management Energy Meter GM3T E GM3T-RS485 E

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Energy Management Energy Analyzer Type EM112

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Ziegler EM 1320/30/40

Technical Datasheet. Delta Power 1000A / 400A AC-DC

Energy Management Energy Meter Type EM110

GAMMA 20 DIGITAL MULTIMETER

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

MultiCube Multi-Function Electricity Meter. Installation and Operation

Energy Management Modular Smart Power Transducer Type SPT-90

Energy Management Energy Analyzer Type EM210 MID

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Digital Multifunction Meter - RISH Integra 2000

Model Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Energy Division

Programmable AC Current Transducer MT418

Energy Management Energy Meter Type EM340

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Technical Data Sheet. Delta 1000/300

EM-72 Electricity Meters for Current Transformers

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Energy Management Energy Analyzer Type EM111

Power analyzers and Energy Meters Power Analyzer Type WM14-96

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

ME432 Three-phase Power Meter

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

SUBJECT TO CHANGE WITHOUT NOTICE

Data Sheet. Earth Leakage Relay RISH ELR/ELR+/ELR VI/ELR VI(NE) A V RISH ELR VI. Record. Digital Protection Relay RESET TEST ENTER

Programmable AC Voltage Transducer MT416

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

Power-meters three-phase

RISH ELR Earth Leakage Relay Preliminary Datasheet True RMS Measurement Trip relay cum DPM CBCT Open Detection 4 digit 7 segment LED display

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power Meter Series PM9

Transcription:

Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. Special Features Available in 3 phase 4 wire, 3 phase 3 wire and single phase version Indication: Healthy phase, Reverse Current Applicable to Standards IEC 62053-21 8 Digit auto-ranging auto-resettable seven segment LED display counter Fully programmable CT ratios Fully programmable PT ratios Built in transient protection Remote data reading through MODBUS (RS-485)

Application is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit provides LED indication for healthy phase, load reverse current. The is available in two version 3phase 4 wire / 3 wire unbalanced load and single phase and is ideal for secondary metering in industrial applications. Product Features 3 phase voltage status Three indications are provided, one for each voltage phase. Three illuminated indication indicate active monitoring of each of the three phases. In case if any one phase voltage is missing the appropriate indication will switch OFF.However the meter will continue to accurately measure energy for the available Programmable Energy format & Energy rollover count Customer can assign the format for energy display on MODBUS (RS-485) in terms of W, kw or MW. Additional to this, customer can also set a rollover count from 7 to 14 digits (for W), 7 to 12 digits (for kw) & 7 to 9 digits (for MW), after which the energy will roll back to zero. The above settings are applicable for all types of energy. voltage phases. In case of phase sequence error all three indication will start blinking. Parameter Screen recall Reverse Three indications are provided for each of connected three phases. Illumination of the indication current indicates a reverse connected CT. transformer The meter will continue to register the energy consumption even if the CT s are reverse connected. Pulse Indication Energy Count storage In case of power failure, the instrument memorizes the last energy count. Every 40 sec, the instrument updates the energy User Assignable Registers for MODBUS Customer can assign MODBUS register address as per his need for faster response time. counter in the non-volatile memory. Low back depth The instrument has very low back depth (behind the panel) of less than 80 mm in spite of optional features like pulse output Compliance to International Safety standards Compliance to International Safety standard IEC 61010-1- 2001 Enclosure Protection for dust and water con rms to IP 54 (front face) www.sifamtinsley.com Page 1 of 6

Dimension Details Reference conditions for Accuracy Reference temperature 23 C +/- 2 C Input waveform Sinusoidal (distortion factor 0.005) Input frequency 50 or 60 Hz ±2% Auxiliary supply voltage Rated Value ±1% Auxiliary supply frequency Rated Value ±1% Voltage Range Current Range Power Factor Power Accuracy 50... 100% of Nominal Value. 10... 100% of Nominal Value. 0.5 lag.1.0.8 lead 10... 100% of Nominal Current & 50... 100% of Nominal Voltage. Active energy (kwh) 1 % (IEC 62053-21) Voltage Current Frequency Active Power Reactive Power Apparent Power Power Factor Phase angle 0.15% of mid frequency 1 % of Unity 1 % of range 3.78 96 mm 3.78 96 mm Front Display Area 3.15 80 mm Input Voltage Input Voltage 110V L-L (63.5V L-N) 230V L-L (133V L-N) 415V L-L (239.6V L-N) Input Current Nominal input current PT Secondary Settable Range 100V 120V L-L (57V 69V L-N) 121V 239V L-L (70V 139V L-N) 240V 480V L-L (140V 277V L-N) 3.62 92mm+0.8 System CT primary values Std. values up to 4kA (1 or 5 Amp ) Starting Current Auxiliary Supply AC Auxiliary Supply 110 V AC -15% / +20% 230 V AC -15% / +20% 380 VAC-15% / +20 ACDC Auxiliary Supply DC Auxiliary Supply AC Auxiliary supply frequency range 0.4% of nominal 100V 250 VAC DC 12..48 VDC 45 to 66 Hz Panel Cutout Max Panel Thickness 0.19, 5mm 3.62 92mm+0.8 www.sifamtinsley.com Page 2 of 6

Electrical Connection Overload Withstand Voltage Current Operating Measuring Ranges Voltage Current Frequency Power Factor Enclosure style Enclosure style Enclosure material Terminals Fixing VA Burden Nominal input voltage burden Nominal input current burden AC Supply burden Counter Counter Reading resolution Indication Indicator display Pulse indicator Dimension Dimension Panel cutout Weight Environmental Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Enclosure 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x for 1 second, repeated 5 times at 5 min 5 120% of rated value 5 120% of rated value 40 70 Hz 0.5 Lag... 1... 0.8 Lead 96 X 96 DIN Quadratic Polycarbonate (Self extinguishing & non dripping as per UL 94 V-0) M4 Screw Type 4 side clamps < 0.2 VA approx. per phase < 0.6 VA approx. per phase 4 VA 8 digit seven segment LED display Auto ranging 3 : Voltage phase monitoring 3 : Reverse connected CT warning. 96mm high x 96mm wide x 80mm deep 92mm x 92mm 320-400 gm -20 to +70 C -30 to +80 C 0... 95% non condensing Minimum 3 minute 15g in 3 planes 10... 55 Hz, 0.15mm amplitude IP54 (front face only) L1 L2 L3 N L1 L2 L3 L1 L2 L3 N For 3 Phase 4 Wire Unbalanced Load 2 5 8 11 1 3 4 6 7 9 13 14 For 3 Phase 3 Wire Unbalanced Load 2 5 8 1 3 2 For Single Phase 11 1 3 L N + - AUX SUPPLY 7 9 13 14 L N + - AUX SUPPLY 13 14 L N + - AUX SUPPLY www.sifamtinsley.com Page 3 of 6

Applicable Standards EMC IEC 61326 Immunity IEC 61000-4-3. 10V/m min Level 3 industrial low level Safety IEC 61010-1-2001, Permanently connected use IP for water & dust IEC60529 Pollution degree 2 Installation category CAT III 300V ac rms High Voltage Test 2.2 kv AC, 50Hz for 1 minute between all electrical circuits Pulse output Relay contact 1 NO Switching Voltage & current for Relay 240 VDC,5 A Default pulse rate divisor 1 per Wh (up to 3600W) 1 per kwh (up to 3600kWh) 1 per MWh (above 3600kW) Other Pulse rate divisors (applicable only when Energy on RS485 is in W) 10 100 1000 1 per 10 Wh (up to 3600W) 1 per 100 Wh (up to 3600W) 1 per 1000 Wh (up to 3600W) 1 per 10 kwh (up to 3600kWh) 1 per 100 kwh (up to 3600kWh) 1 per 1000 kwh (up to 3600kWh) 1 per 10 MWh (above 3600kW) 1 per 100 MWh (above 3600kW) 1 per 1000 MWh (above 3600kW) Pulse Duration 60 ms, 100 ms, 200 ms Displayed Parameters Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire 1. Active Energy (kwh) (8 digit resolution) Parameters Through MODBUS (Optional) Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire - Available - Not available www.sifamtinsley.com Page 4 of 6

Parameters Through MODBUS (Optional) Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire - Available - Not available www.sifamtinsley.com Page 5 of 6

Ordering Information Product Code AP45- X X X X X X X X 00000 System Type 3Ph. (PR. 3W or 4W) 3 1Ph. 1 Input Voltage 220V L-N 1 230V L-N 2 240V L-N 3 300VL-N 4 100VL-L 5 110V L-L 6 220V L-L 7 230V L-L 8 240V L-L 9 380V L-L A 400V L-L B 415V L-L C 440V L-L D 480V L-L E Input Current 5A 5 1A 1 Power Supply 110V AC -15% / +20% L 230V AC -15% / +20% M 380VAC -15% / +20% H 100-250V AC/DC +/- 10% U 45-450V AC/DC +/- 10% W 12V - 48V DC +/- 10% D Self Powered S Pulse Output 1 Pulse output S Pulse O/P not used Z RS-485 MODBUS With RS-485 R Without RS-485 Z Terminal Sealing With Terminal Sealing 1 Without Terminal Sealing Z Accuracy Class 1 1 Class 0.5 5 Sifam Tinsley Instrumentation Inc. 3105, Creekside Village Drive, Suite No. 801, Kennesaw, Georgia 30144 (USA) E-mail Id : psk@sifamtinsley.com Web : www.sifamtinsley.com Contact No. : +1 404 736 4903 Sifam Tinsley Instrumentation Ltd. Central Buildings, Woodland Close, Old Woods Trading Estate, Torquay, Devon, England, TQ27BB Web: www.sifamtinsley.com/uk Contact No. : +44 (0) 1803 615139 www.sifamtinsley.com Page 6 of 6