FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Similar documents
Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

FOM-5A, 6A Asynchronous Fiber Optic Modems

The I-2532 CAN to Fiber Converter

LDM85. Fiber Optic Modem. Description. Features. Specifications

ICF-1280I Series Quick Installation Guide

Miniature Synchronous Multipoint Modems

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Universal RS232/CMOS to RS422/RS485 Converter

FOM-4SF Sync/Async Single Fiber Modem

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

CONV232/422 SERIAL DATA CONVERTER

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Cable and Port Specifications

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

I-2533CS series User Manual

Serial data converters ILPH range

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

This FAQ covers Single Direction use of current loop with transmitting devices.

USER'S MANUAL. Model : K

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

RS-232 Electrical Specifications and a Typical Connection

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Lecture #3 RS232 & 485 protocols

WIRELESS MODBUS GATEWAY WGW410

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

This FAQ covers the common questions from technicians installing these converters.

Preliminary. DN-900 Series. 900 MHz Wireless Serial Modems

CL4790 HARDWARE INTEGRATION GUIDE VERSION 3.0. Americas: Europe: Hong Kong:

There are many important factors when trying to achieve good, reliable communications between 2 devices.

HFD CAN Bus Fiber Optic Converter User Manual

B850 Boiler House Energy Monitor

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

02/11/2015

02/11/2015

CM /100/1000BASE-T

2W UHF MHz Radio Transceiver

OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount)

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

SMARTALPHA RF TRANSCEIVER

DN-90 Series. 900 MHz Wireless Serial Modems

RS-422/485 Application Note

Technical Specifications

B850 Boiler House Energy Monitor

CP485-4 User s Manual

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

Serial Communications RS232, RS485, RS422

Model MT-9485A Microcor Transmitter

MDW-45 Converter RS RS-422/485

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

HFD-FO-LON Series Lonworks Multi-drop Bus Fiber Optic Modem Datasheet & User Manual

CL4490 HARDWARE INTEGRATION GUIDE VERSION 1.0. FCC Notice.

TD_485 Transceiver Modules Application Guide 2017

Industrial Fiber Optic Link/Repeaters *

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Concept of Serial Communication

Intelligent CAN Bus Multi-drop Bus Fiber Optic Converter User Manual

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP

Trendmaster * Dynamic Scanning Module

M-Bus Master MultiPort 250L Installation and User Guide

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

HAWK5000 Operators Manual

4 Channel Contact Closure DIN Fiber Link System

Analog Signal DIN Fiber Link System

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

FC Series Signal Conditioners

MUSE : IP+POWER+RS-232 Transmitter

This special provision is for the installation and testing of the following equipment:

Product Specification. 3.7 Gb/s RoHS Compliant Short-Wavelength SFP Transceiver FTLF8524P3BNL

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

M9606. FSK Modem. 5C Communications Inc.

Stat-4 Stat-8 Stat-24

Ten Port Multi-Band Antenna

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Signet 9950 Dual Channel Transmitter

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

Serial data converters

Technical Note #15. Radio Frequency Modems. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home

SFP 4.25G 850nm Multi mode Optical Transceiver

Transcription:

FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V Isolation MODBUS ASCII/RTU Compatible EMI/RFI Protection The FOSTCDR is our Industrial Serial to Multimode Fiber Optic Converter. Designed for industry, it extends serial data range up to 2.5 miles and provides the most versatile connection possible between any asynchronous full or half-duplex serial equipment. In addition to direct point-to-point connectivity, it is capable operating in a multi-drop mode. This allows one serial device to communicate with up to 31 others around a fiber optic ring. Since it supports mixed serial standards, you can replace other converters and isolators and add the EMI/RFI immunity inherent to fiber optic communications. In RS-232 mode, the FOSTCDR supports transmit and receive data. Handshaking signals are not passed through. An Automatic Send Data Control circuit controls the RS-422/485 driver chip, eliminating the requirement for special software. Easy to install and configure, it has an 8 position DIP Switch to set up the RS-422/485 parameters and terminal blocks to connect serial signals and power. Specifications Serial Technology RS-232 TD, RD, GND RS-485 2-Wire Data A(-), Data B(+), GND RS-422/485 4-Wire TDA(-), TDB(+), RDA(-), RDB(+), GND Serial Connector Terminal Block (24 to14 AWG) Data Rate RS-232 Up to 115.2 Kbps RS-422/485 Up to Up to 460.8 Kbps Isolation 2KV RMS, 1 minute Industrial Bus MODBUS ASCII/RTU Fiber Optic Technology Type / Wavelength Multi-mode / 820 nm Output Power (-) 17 to (-) 10 dbm Receive Sensitivity (-) 25.4 dbm to (-) 24 dbm Cable 62.5/125 micro-meter Connector ST Data Rate 9.6 TO 115.2 kbps Maximum Distance 2.5 miles (4 km) Idle State Transmitter Light ON Power Source External Input Voltage 10 to 30 VDC Power Consumption 4.2 Watts Connector Terminal Block (24 to 14 AWG) Mechanical LED Indicators Serial TD, RD, and Power Dimensions 4.3 x 2.3 x.95 in (11 x 9 x 2.5 cm) Enclosure 35mm DIN Mount, Plastic Weight 0.4 lbs (182 g) Environmental Op Temperature - 40 to 176 F (- 40 to 80 C) Storage Temp - 40 to 185 F (- 40 to 85 C) Op Humidity 0 to 95% Non-condensing Regulatory Approvals FCC, CE, culus Recognized, File E222870 MTBF 460854 hours MTBF Calc. Method MIL 217F Parts Count Reliability Prediction FOSTCDR Accessories MDR-40-12 Ordering Information Serial to Multimode Fiber Optic Converter Industrial Slim-line Power Supply

UL Installation Guidance Underwriters Laboratories Conditions of Acceptability When installed in the end-use equipment, consideration should be given to the following: 1. The wiring terminals are suitable for factory wiring only. 2. This device is to be mounted in a suitable enclosure in the end-product. 3. This device is suitable for operation at a maximum surrounding air temperature as described in the documentation. 4. These devices are intended for use in a pollution degree 2 environment. Input Voltage: 10 30 VDC Input Power 4.2 Watts Wire Range: 12 24 AWG Tightening Torque: 4 kgf-cm Temperature rating of filed installed conductors is 105 C minimum, sized for 60 C ampacity. Use copper wire only Maximum surrounding ambient air temperature 80 C Front Panel 1 Fiber Connectors Multi-mode, ST Connectors 2 PWR LED ON When Power Applied 3 TD LED On When Serial Data Transmitted 4 RD LED On When Serial Data Received 5 DIP Switch 8 Position 6 Terminal Blocks Serial Data and Power pn 8684R1 FOSTCDR-0812ds page 2/5 Terminal Block Terminal Signal A RS-232 RD (OUTPUT) B GND C GND D RS-232 TD (INPUT) E NOT CONNECTED F +10 TO 30 VDC G RS-422/485 TDA(-) / DATA A(-) H RS-422/485 TDB(+) / DATA B (+) J +10 TO 30 VDC K RS-422/485 RDA(-) / DATA A (-) L RS-422/485 RDB(+) / DATA B (+) DIP Switch (SW1) Pos ON OFF 1 RS-422/485 Baud Rate Selection 2 RS-422/485 Baud Rate Selection 3 RS-422/485 Baud Rate Selection 4 RS-422/485 Baud Rate Selection 5 RS-422/485 Baud Rate Selection 6 FO Multi-drop Ring FO Point-to-Point 7 RS-422/485 Mode Selection 8 RS-422/485 Mode Selection Baud 1 2 3 4 5 R9 TIME OUT 1200 ON OFF OFF OFF OFF 820 kω 8.20 ms 2400 ON OFF OFF OFF OFF 430 kω 4.30 ms 4800 OFF OFF OFF OFF ON None 2.20 ms 9600 OFF OFF OFF ON OFF None 1.30 ms 19.2K OFF OFF ON OFF OFF None 0.56 ms 38.4K OFF ON OFF OFF OFF None 0.27 ms 57.6K ON OFF OFF OFF OFF None 0.22 ms 76.8K ON OFF ON ON OFF None 0.14 ms 115.2 K ON ON ON OFF OFF None 0.10 ms 153.6K ON OFF OFF OFF OFF 6.2 kω 0.06 ms 230.4K ON OFF OFF OFF OFF 4.3 kω 0.04 ms 460.8K OFF OFF OFF OFF OFF 2.2 kω 0.02 ms The Dip-Switch defines the mode of operation when being used for RS-422 or RS-485. Positions 1 through 5 determine the timeout of the RS-485 driver. Because the driver is controlled by hardware, a specific time must be set to tell the hardware how long to wait for data on the fiber side before turning off the RS-422/485 driver. If this time is set too short, the driver could be disabled before transmission is complete, resulting in data corruption. If the time is set too long, the device may respond before the RS-422/485 driver in the FOSTCDR is disabled, corrupting this response. Set the timeout for approximately one character time or longer. The character times for several different baud rates are selectable on switch positions 1 through 5. If you need a different timeout than what is provided, R10 can be removed and replaced with a different value R9. This table shows different timeout values for the switch positions as well as R9 replacement values.

RS-422/RS-485 Mode Selection 1. RS-422/485 mode is selected by positioning DIP Switch positions 7 and 8 as shown below. Mode Position 7 Position 8 RS-485 2-Wire ON ON RS-485 4-Wire ON OFF RS-422 OFF OFF RS-485 2-Wire 1. Loosen the screws to open the Serial TB Lead Clamps for the G, H, K, L, and M terminals. 2. Jumper terminal G to terminal K and connect to RS-485 Data A (-) lead. 3. Jumper terminal H to terminal L and connect to RS-485 Data B (+) lead. 4. Connect the signal ground lead to terminal M. 5. Tighten the screws to close the Serial TB Lead Clamps. Ensure the clamps hold the leads securely. However, do not over tighten. 6. Position DIP Switch positions 1 through 5 for t he desired baud rate. 7. Position DIP Switch positions 7 and 8 to ON for RS-485 2-Wire mode. Installation Notes: Not all RS-485 devices are marked correctly for Data (+) and (-), so if the slave devices don t respond after going through the fiber converter, try swapping the wire pairs polarity to each converter. When there is no light received from the fiber in, the receive indicator will be On. You can interconnect or loop back the transmit fiber on one unit to the receive input on the same unit to verity the receive light goes out. If the transmit light is lighted all the time without data, the polarity of the RS-485 is reversed, or there is not enough bias, or termination loads on the RS-485 bus. Normal bias before termination is about 3.8 to 4.0 VDC, Data (+) to (-). See our RS-422/485 Application note for more information on biasing. pn 8684R1 FOSTCDR-0812ds page 3/5 RS-422 / RS-485 4-Wire 1. Loosen the screws to open the Serial TB Lead Clamps for the G, H, K, L, and M terminals. 2. Connect RS-422/485 signal leads as shown in the diagram. 3. Connect the signal ground lead to terminal M. 4. Tighten the screws to close the Serial TB Lead Clamps. Ensure the clamps hold the leads securely. However, do not over tighten. 5. Position DIP Switch positions 1 through 5 for t he desired baud rate. 6. Position DIP Switch positions 7 to ON and 4 to OFF for RS- 485 4-Wire mode. Set DIP Switch positions 7 and 8 to OFF for RS-422 mode. Installation Notes: Not all RS-485 devices are marked correctly for Data (+) and (-), so if the slave devices don t respond after going through the fiber converter, try swapping the wire pairs polarity to each converter. When there is no light received from the fiber in, the receive indicator will be On. You can interconnect or loop back the transmit fiber on one unit to the receive input on the same unit to verity the receive light goes out. If the transmit light is lighted all the time without data, the polarity of the RS-485 is reversed, or there is not enough bias, or termination loads on the RS-485 bus. Normal bias before termination is about 3.8 to 4.0 VDC, Data (+) to (-). See our RS-422/485 Application note for more information on biasing.

pn 8684R1 FOSTCDR-0812ds page 4/5 RS-232 1. Loosen the screws to open the Serial TB Lead Clamps for the D, A, and B terminals. 2. Insert the RS-232 Signal Leads into the TB. Refer to the diagram above for DTE and DCE wiring configurations. 3. Tighten the screws to close the Serial TB Lead Clamps. Ensure the clamps hold the leads securely. However, do not over tighten. Installation Notes: DIP Switch Positions 1 through 5, 7 and 8 are not used in RS- 232 Mode. Set switch 6 to OFF. The wiring example shows a DTE device on one end and a DCE device on the other. Handshaking signals are not passed through. Fiber Optic 1. Ensure your fiber optic cable is terminated with an ST type connector. 62.5/125 micro-meter multimode cable is recommended. 2. Connect the converter s transmitter to the distant end receiver and vice-versa. 3. The fiber optic transmitter light is ON in the idle state. Therefore, the RX indicator will be lighted when data is not being transferred. 4. DIP Switch SW1-6 is used to select point-to-point or multidrop mode. For point-to-point, set the switch to OFF for both converters. For multi-drop, set the switch to ON for each converter in the ring. With SW1-6 in the ON position, receive data will be looped back to the fiber optic transmitter. Data will repeat around the ring until it finally reaches its source. When the data is received by the originator, timeout circuitry will prevent it from being retransmitted. Maximum Converters in a Fiber Ring Baud Rate RS-232 RS-422/485 19.2 kbps and lower 32 32 38.4 kbps 16 24 115.2 kbps 2 8 Fiber Optic Point-to-Point Fiber Optic Multi-drop Ring RS-232 Loopback Test 1. Configure the converter for RS-232. 2. Set DIP Switch SW1-6 to OFF. 3. Cross-connect the fiber optic transmitter to the fiber optic receiver using a multimode patch cord. 4. Connect a PC to the serial port. 5. Using Hyper Terminal or similar program, connect to the appropriate COM port. Set the baud rate to match the converter. Ensure Hyper Terminal local echo is OFF. 6. Transmit data. If the same character string is returned, the test is good.

pn 8684R1 FOSTCDR-0812ds page 5/5 Power An external 10 to 30 VDC power supply is required. Attach power leads as shown above. Power use is 4.2 Watts. Mechanical Diagram