SELECTED OWENS CORNING ASPHALT SHINGLES APPLY A BEAD OF BITUMASTIC ADHESIVE/SEALANT METAL BARGE DRIP EDGE FLASHING No15 RAG FELT ROOF UNDERLAY PLYWOOD ROOF FRAME BARGE BOARD SOFFIT LINING (IF APPLICABLE) TYPICAL BARGE DETAIL - CROSS SECTION BARGE-CROSS SECTION
SELECTED OWENS CORNING ASPHALT SHINGLES SHINGLE STARTER ROLL 180mm OR STARTER STRIP WITH ADHESIVE BEAD INCORPORATED METAL EAVE DRIP EDGE FLASHING No15 RAG FELT ROOF UNDERLAY PLYWOOD SELECTED GUTTERING RAFTER FASCIA BOARD SOFFIT LINING (IF APPLICABLE) NOG (POSITION TO ALLOW FOR AIR FLOW) AIR VENT GAP TYPICAL EAVE DETAIL - CROSS SECTION EAVE-CROSS SECTION 003
SELECTED OWENS CORNING ASPHALT SHINGLES HIP CAPPING SHINGLE No15 RAG FELT ROOF UNDERLAY HIP RAFTER PLYWOOD ROOF FRAMING TYPICAL HIP DETAIL- CROSS SECTION HIP-CROSS SECTION 005
RIDGE CAPPING SHINGLE NOGS (POSITIONED TO ALLOW AIR FLOW) SOUTH PACIFIC SHINGLES RIDGE VENT SELECTED OWENS CORNING ASPHALT SHINGLES ROOF FRAMING No15 RAG FELT ROOF UNDERLAY PLYWOOD AIR VENT GAP TYPICAL RIDGE DETAIL- CROSS SECTION RIDGE-CROSS SECTION 006
#15 ragfelt Bitumen based roofing underlay laid over 15mm untreated construction plywood substrate Lay shingles across Valley from smaller roof to larger Shingles from larger roof area to overlap shingles from smaller roof Owens Corning asphalt shingles by South Pacific Shingles on 15mm roofing grade plywood to manufacturers specifications. Fascia board with gutter as per plans Trim shingles to form clean lines Stainless steel clouts to fix shingles to roof in accordance manufacturers specifications Center line of valley Overlapping shingles to be no closer than 50mm to centerline of valley Valley Cladding Detail N.T.S Valley Cladding Detail N.T.S
SELECTED OWENS CORNING ASPHALT SHINGLES APPLY A BEAD OF BITUMASTIC ADHESIVE/SEALANT METAL BARGE DRIP EDGE FLASHING No15 RAG FELT ROOF UNDERLAY PLYWOOD ROOF FRAME BARGE BOARD SOFFIT LINING (IF APPLICABLE) TYPICAL BARGE DETAIL - CROSS SECTION BARGE-CROSS SECTION
SOUTH PACIFIC SHINGLES RIDGE VENT (IN ROOF VENTS ALSO ACCEPTABLE) SELECTED OWENS CORNING ASPHALT SHINGLES No15 RAG FELT ROOF UNDERLAY PLYWOOD ROOF FRAME COLOURSTEEL OR COPPER RIDGE FLASHING AIR VENT GAP BARGE BOARD NOG (POSITION TO ALLOW AIR FLOW) SELECTED CLADDING WALL FRAME TYPICAL ROOF/WALL RIDGE DETAIL - CROSS SECTION ROOF/WALL RIDGE-CROSS SECTION 004
Cladding, refer to manufacturers specifications for installation, on approved cavity system on specified underlay. lap 150mm Butynol waterproofing membrane or similar approved, install before wall cladding & lap behind cavity & building wrap. Owens Corning asphalt shingles by South Pacific Shingles on15mm roofing grade plywood to manufacturers specifications. 10 Vent. Nog between 10mm gap to allow air flow. Typical Owens Corning Shingle Vented Apron Flashing - Roof to Wall Vented Apron Flashing - Roof to wall
Cladding, refer to manufacturers specifications for installation, on approved cavity system on specified underlay. Owens Corning Asphalt Shingles by South Pacific Shingles - on 15mm roofing grade plywood to manufacturers specifications. 150 Butynol waterproofing membrane or similar approved, lap behind cladding and shingles. #15 Ragfelt Underlay Owens Corning Shingles Chimney Flashing owens corning shingles chimney flashing
Owens Corning Asphalt Shingles by South Pacific Shingles on 15mm roofing grade plywood to manufacturers specifications. #15 ragfelt Bitumen based roofing underlay over plywood substrate. Flashing Detail for Change in Roof Pitch Flashing detail for change in roof pitch
Approved cavity wrap. Cladding, refer to manufacturers specifications for installation, on approved cavity system. Standard butynol corner stopend - cladding cut over and sealed 80mm min butynol overlap 22 0 140mm shingle exposure 150 solid nog Flashing tape or extra layer of building wrap over butynol flashing under each course of shingles. Owens Corning asphalt shingles by SPS on 15mm roofing grade plywood to manufacturers specifications. Typical Owens Corning Shingle Gutter to Wall Junction Gutter to wall junction
Stack/vent pipe with venting cap carried through shingles and substrate. Refer to plan for placement and sizing #15 ragfelt Bitumen based roofing underlay over plywood substrate to be laid over top of butynal flashing Owens Corning shingles by South Pacific Shingles Butynol flashing to be fixed under the asphalt shingles. Fold top edge to form min 10mm anti capillary hem Dress lower edge of flashing over shingles and secure 100mm strip continuous around the base Pipe Penetration pipe penetration
0.55 colorsteel apron flashing pop rivet fixed upon a bead of sealant over glazing bar & butynol flashing Screw fix roof glazing unit Toughened overhead glazing Owens Corning asphalt shingles by SPS over specified underlay on 15mm roofing grade plywood to manufacturers specifications. #15 ragfelt underlay Butynol flashing turned up upstand with folded colorsteel flashing over HEAD 65 0.55 colorsteel apron flashing pop rivet fixed upon a bead of sealant over butynol flashing 100 min Butynol flashing turned up roof glazing upstand with last roofing shingle over Owens Corning asphalt shingles by SPS over specified underlay on 15mm roofing grade plywood to manufacturers specifications. SILL Owens Corning roof to skylight head and sill detail Roof to skylight head and sill detail