TECHNICAL SPECIFICATION SCHEDULE

Similar documents
μscope Microscopy Software

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

Option G 2: Lenses. The diagram below shows the image of a square grid as produced by a lens that does not cause spherical aberration.

STRUCTURE OF THE MICROSCOPE

Huvitz Digital Microscope HDS-5800

Features included in i-solution

Characterization Microscope Nikon LV150

Components of the Microscope

GXCapture 8.1 Instruction Manual

OMM300. Inverted Metallurgical Microscope

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

STEINDORFF NYMC Polarizing Microscope

Sunny Instruments. RX50 Biological Microscope

MEASUREMENT CAMERA USER GUIDE

GlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide

Basics of Light Microscopy and Metallography

Fein. High Sensitivity Microscope Camera with Advanced Software 3DCxM20-20 Megapixels

ECEN 4606, UNDERGRADUATE OPTICS LAB

ISCapture User Guide. advanced CCD imaging. Opticstar

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

Person s Optics Test KEY SSSS

Optika ISview. Image acquisition and processing software. Instruction Manual

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Physics 1230 Homework 8 Due Friday June 24, 2016

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Family of Stereo Microscopes Quality microscopes for industry and life sciences

Zoom Stereo Microscope NYMCS-360 Instruction Manual

Real-color High Sensitivity Scientific Camera

Real-color High Sensitivity Scientific Camera. For the first time with true color ISO9001

Marine Invertebrate Zoology Microscope Introduction

BA310POL ADVANCED POLARIZATION MICROSCOPE

Very short introduction to light microscopy and digital imaging

Lecture Outline Chapter 27. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

Microscopy. Danil Hammoudi.MD

TABLE OF CONTENTS. Safety notes i. Care and Maintenance. ii. 1. Components Illustration Installation of Components.. 4

Introduction. Laboratory Equipment & Supplies. Model 1333PHi Shown (Phase Contrast) (2) Eyepieces (Eyecups installed) Diopter Adjustment Mechanism

Therefore, all descriptions and illustrations in this instruction manual, including all specifications are subject to change without notice.

Colony Imaging with powerful Analysis Software

Microscope anatomy, image formation and resolution

Lab: The Compound Microscope

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

Zeiss AxioImager.Z2 Brightfield Protocol

4 Use the adjustable Focus meter tool to take the subjectivity out of focusing the image, to get the best possible image

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Chapter 29/30. Wave Fronts and Rays. Refraction of Sound. Dispersion in a Prism. Index of Refraction. Refraction and Lenses

The invention of the microscope made it possible for scientists to view and study cells. Cells the basic units of all living organisms.

Things to check before start-up.

SEIMITU WAVE AR1260. Allegro. Mobility LLC

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

Bringing Answers to the Surface

Introduction of New Products

Instruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

Leica DB LB Research microscope and Studo Lite Imaging software

A BRIEF INTRODUCTION TO MICROSCOPY The two key properties of a microscope that allow you to see microbes are resolution and magnification.

Using Olympus dotslide for polarising microscopy

PIXERA InStudio Software Package

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

XSP-100XSP-100SM/ OF BIOLOGICAL MICROSCOPE OPERATION MANUAL READ THIS MANUAL BEFORE USING THE MICROSCOPE

Swift M10 Series Microscope Use and Care Manual

User Guide of ISCapture

Chapter 36. Image Formation

Chapter 36. Image Formation

Leica SP8 TCS Users Manual

University of Rochester Department of Physics and Astronomy Physics123, Spring Homework 5 - Solutions

Indian Institute of technology Madras Presents NPTEL NATIONAL PROGRAMME ON TECHNOLOGY ENHANCED LEARNING

PHYSICS. Chapter 35 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

Upright Microscope. Upright Microscope ECLIPSE Ci-E/Ci-L

Biological Microscope. Biological Microscope ECLIPSE E100

OPTICAL SYSTEMS OBJECTIVES

CALIBRATION OF MICROSCOPE EYEPIECE GRATICULE

Be aware that there is no universal notation for the various quantities.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Follow our guidelines carefully to ensure proper system function. EQUIPMENT

Eyepieces KHW10X. Diopter Adjustment Ring. Binocular Body Inclined 30. Binocular Clamp Screw. Analyzer control Lever. Reflected Light Illuminator

Leica DMi8A Quick Guide

Swift M10D Series Microscope Use and Care Manual

CHROMACAL User Guide (v 1.1) User Guide

User Manual. Copyright 2010 Lumos. All rights reserved

AgilEye Manual Version 2.0 February 28, 2007

Using the Microscope for a NANSLO Remote Web-based Science Lab Activity

Applications of Optics

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

A machine vision system for scanner-based laser welding of polymers

CHAPTER 18 REFRACTION & LENSES

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Colony Imaging with powerful Analysis Software

Advanced Diploma in. Photoshop. Summary Notes

Indian Institute of Technology Bombay

Optilia OptiPix Image View, Capture, Archiving and Measurement software

Leica SP8 TCS Users Manual

Manual Stage Configuration

SWIFT SERIES M2252DGL MICROSCOPE

a) How big will that physical image of the cells be your camera sensor?

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Ⅰ. Application. Ⅱ. Main Technical Specification. AS1 Biological microscope,which is widely used in medical and

Transcription:

LAMPIRAN Q5 MEMBEKAL, MENGHANTAR, MEMASANG DAN KOMISYEN METALLURGICAL MICROSCOPE WITH COMPUTER ATTACHMENT KE P.P.KEJ. B AHAN & SUMBER MINERAL, UNIVERSITI SAINS MALAYSIA, KAMPUS KEJURUTERAAN Quotation No: SH2/18/END/PBAHAN/P/00041 TECHNICAL SPECIFICATION SCHEDULE ITEM NO. UNIVERSITY S DESCRIPTION QUANTITY BIDDER S SPECIFICATION (Please Write Your Specification In This Column) TECHNICAL EVALUATION (For Official Use Only) 1 A. ITEM Metallurgical Microscope With Computer Attachment B. DESCRIPTION One (1) microscope that is capable to perform research-level metallurgical works with the digital metallurgical image analyzer including digital camera, image analyzer and personal computer. The system must generate high quality micrographs and accurate metallurgical results. C. ESSENTIAL FEATURES One (1) microscope that is equipped with essential metallurgical observation modes - bright field, simple polarizing, side enhanced view and metallurgical tint contrast methods, and thus capable to reveal microstructures of various metallurgical specimens. This microscope must be perfectly adapted to digital camera and image analyzer to render high quality digital image for research-level metallurgical works. One (1) digital camera that is capable to render actual colour live view at relatively high speed and covers most of the eyepiece view area. One (1) metallurgical type image analyzer that can perform multiple live functions and correct/enhance the captured image to the highest quality. The image analyzer must be able to perform accurate measurement and analysis with instant report output. One (1) personal computer with compatible specification for above digital camera and image analyzer with at least 23 inch full high definition monitor. 1

D. TECHNICAL SPECIFICATION 1. Metallurgical Microscope The microscope must be of a metallurgical type with incident top illumination and metallurgical objective lens (dry type lens without coverslip correction). The microscope must have rigid body (such as Y-frame) to allow sturdy observation. The microscope must allow essential metallurgical contrast methods as follows: - Bright field - Simple polarizing (360 o rotatable analyzer) - Side enhanced view (adjustable) - Metallurgical tint The objective lens must be of plan achromatic type to deliver an undistorted image with chromatic aberration correction. The optical magnification range must be within 50x 1000x with 5x, 10x, 20x, 50x and 100x objective lens. The nosepiece must be of backward quintuple type. All the objective lens must be parfocal. Infinity type objective lens must be adopted to allow the addition of filters such as a polarizer and tint plate without affecting the image quality. Long working distance feature must be incorporated in the following lenses to avoid collision with the specimen. - 20x (working distance not less than 4 mm) - 50x (working distance not less than 7 mm) - 100x (working distance not less than 2 mm) The eyepiece must be of 10x and wide field 22 mm type. The eyepiece must have diopter and distance adjustment. The microscope must be of trinocular with photoport. The photoport must deliver image size on monitor live view at not less than 75% of the coverage from eyepiece view. The microscope must allow synchronized view at the eyepiece and monitor live view at the same time without having to switch. The photoport must deliver parfocal live view on monitor and eyepiece, meaning when the eyepiece image is in focus, live view image also in focus. 2

The C-mount lens on photoport must be of plan undistorted lens and focusable to achieve parfocality. The microscope must have a high resistant mechanical stage with size approximate 175 x 145 mm and travel range approximate 76x42 mm. The microscope must have a 360 o free-rotating attachment on the stage to facilitate the rotating of specimen. The illumination must be precentered single high-intensity LED with power at least 5W. The illumination must be filterless with consistent white colour light. The focus drive must be of coaxial coarse and fine focus system with distance approximate 28 mm per revolution. The microscope must accommodate observation on the top surface of the specimen as high as 80 mm or more. The microscope must have adjustable aperture to control focal depth. The microscope must have an adjustable field diaphragm. 2. Digital Camera The digital camera must have at least full high definition (FHD) resolution. The camera must directly connect to a standard personal computer via a simple USB interface without having to go through other adaptor. The frame rate must be at least 30 frames per second. The camera must be compatible with the photoport C-mount of above microscope and cover at least 75% of the eyepiece view area. The camera must be compatible to live view, live measurement, live focus and live stitching functions of the image analyzer. The camera must have auto and manual exposure settings. The camera must have auto and manual white balance settings. The camera must have an unlimited saved setting and to be recalled instantly according to user s requirements. The saved setting files of the camera must be exportable to other personal computer. 3. Image Analyser (IA) The image analyzer must have the following CAPTURING FUNCTIONS: IA must allow direct personal computer control of the above camera for following Live functions: Live view (with full screen option). Live measurement and analysis. 3

Live focus enhancement (processing must be instant, time less than approximate 3 seconds). Live image stitching. IA must have shading correction at capture. IA must have time lapse capture and movie recording. IA must have adjustable crosshairs and grid masks (square & circle) at any desired position. IA must have scale, time stamp, and transparent image overlay at live view. IA must allow unlimited capture setting save and load. The image analyzer must have the following PROCESSING FUNCTIONS: IA must be able to correct the image shading. IA must be able to correct reflection and highlight. IA must be able to compose a high dynamic range (HDR) image. IA must have an uneven illumination correction function. IA must have standard focus enhancement (extended depth-offocus) for all-in-focus image view with fast processing time (< approximate 3 seconds). The standard focus enhancement must have auto-alignment functions for stereoscopic or any possible displacement during capture. The image analyzer must be equipped with advanced focus enhancement with sub-pixel accuracy focus that caters for translucent/transparent objects. IA must have manual multi-image stitching with instant auto-adjust function. IA must come with an auto image stitching function with fast processing time (< approximate 5 seconds). The above image stitching must have smooth-combine function to filter away uneven image brightness for final smooth and even composite image. IA must have edge generating filters to allow the generation of coloretched grain boundaries. IA must be able to remove noise and particles automatically. Morphological filters must be included. IA must have brightness/contrast/gamma adjustment functions. IA must allow the generation of pseudo color for a gray scale image (i.e. SEM) colorization. IA must be able to generate 3D representative image visualization based on different depth of focus. 4

The 3D surface modelling must come with XYZ positioning and ambient lighting control. IA must have standard fluorescence mask functions. The image analyzer must have the following MEASUREMENT FUNCTIONS: IA must allow auto calibration to prevent human errors. The calibration must come with security password protection. IA must be able to share the calibration file and backup in other personal computer. IA must have manual tagging (classification, count per 1mm2 or 1mL, and direct-to-excel report). The IA must have an intensity profile function (straight line, polyline & parallel line). IA must have a zoom-in magnification window (up to 20 X). IA must allow pixel-accurate measurement by adjusting the position with the arrow keypad cursor, one press on the arrow keypad corresponds to one pixel movement. IA must have standard manual measurement functions such as line, polyline, spline, 2-point/3-point/multi-point circle, arc, rectangular, polygon, 3-point angle, horizontal/vertical line. IA must have advanced manual measurement such as auto-trace of edge, an angle between 2 lines, distance between 2 objects, perpendicular width, perpendicular distance from common line, parallel measurement, irregular diameter, distance from common point, width and height measurement, weld measurement etc. IA must have annotation and labeling functions. The image analyzer must have the following REPORT FUNCTIONS: IA must be able to perform quick export of report to Microsoft Office Excel. The Excel report must include company logo, original/overlay images, data, statistics, chart. 4. PERSONAL COMPUTER Intel i3 microprocessor or higher RAM at least 4GB Hard disk at least 500GB Win7 and above 22 or bigger size FHD LED monitor E. STANDARD REQUIREMENTS AND INSTRUCTIONS 5

The equipment supplier must be a brand new with proper serial number to prove it and must not be a used or a reconditioned instrument The equipment must be fully installed and made fully functioning. Service & Operating Manual and original Catalogue in English must be provided, at least 2 copies. The Equipment supplied must be warranted against manufacturing defects for at least 12 months from the date of commissioning. Free preventive maintenance service 1 x 6 monthly during the warranty period. The supplier has to give information regarding their servicing capabilities / after sales service for the equipment quoted. On-Site training must be provided for operation, maintenance and troubleshooting. Quotation that does not quote prices exclusive of tax will not be considered. Service contract and software upgrading must be quote separately Bidder should attach their proof of sole distributor agent for their services/maintenance capability. NOTE: FOR ALL SUPPLIES, PLEASE OFFER THE MINIMUM REQUIRED SPECIFICATIONS OR BETTER VERSIONS. Signature & Company Stamp 6