IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

Similar documents
- Continuous real-time measurement and PD trend analysis; not multiplexed data collection.

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

TECHIMP Power Transformer Monitoring

ABB Power Products Service

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Končar TMS - Bushing monitoring

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Monitoring Solutions For Power Transformers, Reactors, Bushings and Instrument Transformers

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Substation Preventive Maintenance

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

Benefits of SFRA - Case Studies

Advanced, accurate and intelligent monitoring for your transformer

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

New Laboratory Stand and Teaching Program Transformer Monitoring System

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

Utility Communications Teleprotection Equipment TPT-200

TECHIMP Technologies & Services for Diagnostics and Monitoring of High Voltage Assets

Improve asset protection and utilization

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

Tap Changer Analyzer & Winding Ohmmeter RMO-TT

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

The Generators and Electric Motor Monitoring and Diagnostics Systems

Doble Solutions for Partial Discharge. Greg Topjian Solutions Manager

Three-Phase Transformer Demagnetizer DEM60

7. INSPECTION AND TEST PROCEDURES

Acoustic Emission in power transformers. Ajusco 15, Colonia Portales, Delegación Benito Juárez, C.P , México, D.F.

satech SynchroStar GPS 200 Series

Autotransformer Condition Monitoring Systems

Hands-On Transformer Testing and Maintenance

REPORT ON INVESTIGATION OF FAILURE OF 100 MVA, 220/66-33/11 KV POWER TRANSFORMER AT 220KV GEETA COLONY SUBSTATION OF DELHI TRANSCO LTD.

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Field Measurement of Transmission Cable Dissipation Factor

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

ALPTEC POWER FACTOR CONTROLLER

Power IT LV Active Filters PQFA - PQFL - PQFT

The importance of partial discharge testing throughout the development and operation of power transformers

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

1ZSC AAJ en, Rev. 1. Vacuum on-load tap-changers, type VUBB Technical guide

Chapter 7 Conclusion 7.1 General

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Stabilized Differential Relay SPAD 346. Product Guide

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information.

Wind Turbine Analysis System - Type 3652 MKII & MKIII

Condition-based maintenance of power transformers Complete three-phase system Turns Ratio: Recovery Voltage: Winding Resistance:

Three-Phase Winding Ohmmeter TWA25K

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

CASE STUDY- FAULT IN POWER TRANSFORMER AT LOKTAK POWER STATION. - S K Mishra & S K Das NHPC Ltd O&M Division

BATAILG TAIL GAS ANALYZER. Rev. 1.1

DEFERRING REPLACEMENT OF A 600 MVA, 345GRD Y/138GRD Y/ 13.8 kv SHELL TYPE WESTINGHOUSE AUTOTRANSFORMER

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

VARIABLE FREQUENCY RESONANT TEST SYSTEM

1ZSE Intelligent monitoring system, type TEC User s manual

Mots clés Power Transformer, Condition Assessment, On-line Monitoring Internet. Par S. Tenbohlen *, T. Stirl, M. Rösner * * ALSTOM T&D, Germany

Tap Changer Analyzer & Winding Ohmmeter RMO-TD Series

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Winding Ohmmeter RMO-TW

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

Revision of C Guide for Application of Monitoring Equipment to Liquid Immersed Transformers and Components. Mike Spurlock Chairman

High precision measurement system for current and voltage IHC-A/B-RM01/03

Electronic fan speed regulators

LIGHT ARC DETECTOR Type LAD

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

PARTIAL DISCHARGE MEASUREMENT

PD Diagnostic Applications and TechImp solutions

CHAPTER 3 REVIEW OF POWER TRANSFORMER PROTECTION SCHEMES

Winding Ohmmeter & Tap Changer Test Set RMO10TW

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Electrical Equipment Condition Assessment

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Maintenance & Diagnosis Strategies. for. High Voltage Substations

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

KLEA 220P ENERGY ANALYZER

HITEK POWER OLS10K SERIES

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Effective Maintenance Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

Basic Principles and Operation of Transformer

Effective maintenance test techniques for power transformers

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

VI 3 - i TABLE OF CONTENTS

LV Compensation & Filtering Products

TECHNICAL SPECIFICATIONS

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

SWT 3000 Teleprotection technical data siemens.com

Automatic Transformer Winding Analyser

Transcription:

Taking into account that power transformer is the major item of equipment in power systems, its correct operation is vital to system operation. It is well known that transformer failures are sometimes catastrophic and almost always include irreversible internal damage. The monitoring of power transformers makes possible to obtain the maximum practicable operating efficiency and optimum life of power transformers, minimizing the risk of premature failures and providing potential for changing the maintenance strategies. Research, Development and Testing National Institute for Electrical Engineering ICMET Craiova has developed and designed Microprocessor-based equipment for power transformer protection and operation monitoring, type MONITRA - IMT 02SE. MONITRA - IMT 02SE equipment is intended to protect and monitor the power transformer operation; it monitors oil temperature, level of oil in tank and OLTC, temperature of HV and LV windings, condition of OLTC, temperature of magnetic core, oil temperature at the input and output from cooling batteries, environment temperature, tan δ, capacitive currents of the bushings, partial discharge level, dissolved gases (H 2, CO) concentration, oil moisture level, on/off states of the pumps and fans, gas volume in Buchholz relay. Architecture of the monitoring equipment, with OPC server

Advantages of continuous monitoring: Prevention of transformer failures and downtimes Transformer life extension leading to the delay of investment for a new transformer Optimization of transformer use by means of condition based maintenance instead of time based maintenance Because of its modularity, the equipment can easily be focused on the customers needs and on the requirements of the monitored transformer, any configuration being available when requested. TECHNICAL CHARACTERISTICS Configuration: Block diagram of the monitoring equipment Analogic inputs Input for windings current (3 inputs) Input for magnetic core temperature (max. 6 inputs) Input for environment temperature (1 input) Input for OLTC oil temperature (1 input) Input for temperature at the input and output from the cooling batteries (10 inputs) Input for monitoring the quantities characteristics for the bushings (tan δ, capacitive current) (max. 6 inputs) Input for monitoring the content of H 2 in oil (1 input) Input for monitoring the content of CO in oil (1 input) Input for monitoring the content of H 2 O in oil (1 input) Input for monitoring the gas volume in Buchholz relay (1 input) Input for monitoring oil temperature (1 input) Input for oil level (2 inputs) Input for high voltages and low voltages and currents (6 inputs for voltages + 6 inputs for currents) Input for voltages of drive motor OLTC (3 inputs) Input for partial discharge level from DUDP-2N (PD Acoustic Emission Detector) (4 inputs)

Digital inputs Inputs for pumps and fans monitoring (18 inputs) Inputs for OLTC position monitoring (5 inputs) Input for presence of oil in the ATMOSEAL bag (1 input) Outputs Control relays ( 10 A; 250 V AC ): One contact for the cooling step I One contact for the cooling step II One contact for alarm oil temperature One contact for trip oil temperature One contact for alarm temperature of winding One contact for trip temperature of winding One contact for minimum level of oil One contact for maximum level of oil One contact for signaling the increase of H 2 concentration over a preset value One contact for signaling the increase of CO concentration over a preset value One contact for signaling the increase of H 2 O concentration over a preset value One contact for exceeding the tan δ alarm level for HV bushings One contact for exceeding the tan δ alarm level for LV bushings One contact for exceeding the capacitive current alarm level for HV bushings One contact for exceeding the capacitive current alarm level for LV bushings One contacts for the partial discharge level exceeding Note: Alarm level values can be easily set and changed from the keyboard Software: IMT 02SE Equipment is delivered with the software necessary to send the stored data through the serial interface RS 232 or RS 485. Analysis software allows the rapid interpretation of the stored data, and their arrangement as tables Window for computer communication with IMT 02S

The device is provided with a keyboard and a local display, allowing the programming (prescribing the alarm thresholds, delays at relay connection and disconnection, constants specific to transformer) and local or remote display of the quantities monitored. Additionally, the relay condition is locally signaled, by LEDs, Note: All the values introduced from the equipment keyboard can be introduced and coded also from the computer keyboard. Window for alarm parameter The main menu is accessible by pressing any key and gives the possibility to visualize the monitored quantities (SUPERVISE), to set the transformer parameters and the quantities required for operation (CONFIG), to calibrate the input quantities (CALIBRATE) and to simulate the operation (SIMULATE). MONITRA - IMT 02SE equipment is provided with a real - time clock and a battery allowing autonomous operation for 10 years. It is possible to store the value of monitored quantities, at programmable time intervals, for a period of about 2 months. The stored data can be transmitted by the RS 232 interface to IBM-PC compatible equipment. When the buffer is 90% filled, it is necessary to save the stored data. Window with display of monitored quantities

Monitored and Displayed quantities Domain Oil temperature Winding temperature Oil level in tank and OLTC Dissolved hydrogen concentration Dissolved carbon oxide concentration Oil moisture Partial discharge level 0 to 120 0 C 0 to 150 0 C 0 to 100 0 C 0 to 2000 ppm 0 to 2000 ppm 0 to 100 ppm 0 to 10000pC Tan δ for the bushings 0,1 to 4 % Capacitive current for the bushings Working time Spent life time Oil pumps condition Fans condition 0 to 100 ma hours hours on/off on/off Gas in Buchholz relay 0 to 400 cm 3 OLTC condition - phase current/voltage of the tap changer driving motor - active power absorbed when switching - tap changer position - total number of switching operation

Programming range for the protection levels Oil temperature: - range: 0 to 120 0 C - difference: 0 to 10 0 C - alarm delay: 0 to 40 minutes Winding temperature: - range: 0 to 150 0 C - difference: 0 to 10 0 C - alarm delay: 0 to 40 minutes Oil level in the tank and OLTC: - range: 0 to 100% - difference: 0 to 10% - alarm delay: 0 to 40 minutes Dissolved hydrogen concentration: - range 0 to 2000 ppm - difference 0 to 100 ppm Dissolved carbon oxide: - range 0 to 2000 ppm - difference 0 to 100 ppm Oil moisture level: - range 0 to 100 ppm - difference 0 to 5 ppm Partial discharge level - range 0 to 10000 pc - difference 0 to 500 pc Tan δ for the bushings: - range 0,1 to 4% - difference 0 to 0,1 % Capacitive current for the bushings: - range 0 to 100 ma - difference 0 to 1 ma Gas in Buchholz relay: - range 10 to 400 cm 3 - difference 0 to 10 cm 3

Mains supply: 90 to 264 V AC, 50 Hz ; 120 to 370 V DC Measurement accuracy: Oil temperature ± 1 0 C Winding temperature ± 2 0 C Oil level ± 1% H 2 concentration ± 15 ppm CO concentration ±15 ppm H 2 O concentration ± 5 ppm Partial Discharge level ± 100 pc Tan δ ± 0,1 Capacitive current ± 1.5% Gas in Buchholz relay ± 5 cm 3 Note: At the measuring accuracy for H 2, CO and H 2 O it is added the measuring accuracy of measuring equipment Environmental conditions: Range of operating temperatures -5 0 C + 50 0 C Protection degree IP 50 Maximum altitude 1000 m Overall dimensions: IMT 02SE DUDP 2N: W x H x D = 305 x 225 x 123 mm W x H x D = 295 x 205 x 180 mm Accessories: Communication adapter Multiplexer Electric switch box

Tests Immunity - power frequency electromagnetic field IEC 61000-4-8 - voltage interruptions or supply voltage variations IEC 61000-4-11 - surge IEC 61000-4-5 - electrostatic discharge SR EN 61000-4-2 Measurement - conducted disturbances CISPR 22 Optionally, data transmission could be carried out by optical fiber or cable, between the electric switch box INTERMON and the central unit within the control room. Other facilities: MONITORING OF GAS VOLUME IN BUCHHOLZ RELAY For monitoring the gas volume within Buchholz relay, the output signal of the relay measuring unit is used (standard signal 4 20 ma) Fig. 1 Using diagram of the Buchholz relay as a component of the monitoring system

The output signal of the capacitive sensor amplifier is a current signal depending on the insulating liquid level. This dependence is presented in Figure 2. Fig.2 Current gas volume variation MONITORING OF OIL PRESENCE IN THE ATMOSEAL- TYPE BAG INSIDE THE CONSERVATOR The oil detection system is used for signaling the decrease of the maximum oil level from the ATMOSEAL type conservators from power transformers, due to the cracking of the bag-type membrane from inside the conservators or to the accidental appearance of major oil losses. The oil detection system is composed of: I. Detector for presence of oil placed inside, at the upper side of the conservator; II. Control Module for Signaling the Presence of Oil placed in the electric switch box of the transformer.

Technical characteristics Working medium Pressure of the working medium Working temperature Supply voltage of the Control Module for Signaling the Presence of Oil Detector supply voltage Rated current of relay contact transformer oil 0-5 bar -20 0 C to + 85 0 C; -40 0 C to + 105 0 C 110 220 V AC 12 V DC 8 A / 24 V DC or 4 A/250 V AC MONITORING OF POWER TRANSFORMER ON LOAD TAP CHANGER (TAP POSITIONS AND DRIVING MOTOR CURRENT) The microcontroller-based system for monitoring the on load tap changer performs this function by acquiring the parameters influencing the tap changer condition: - phase current/voltage of the tap changer driving motor - active power absorbed when switching - tap changer position - total number of switching operations The data package acquired during a switching operation is sent (using a serial output RS232) to a personal computer where the data can be stored and analyzed with a view to determining the condition of the on load tap changer. Technical characteristics Supply: 220 V, 50 Hz Inputs: - 4 analog inputs: supplying of the on load tap changer driving motor 3 x 380 V, 50 Hz (L1, L2, L3, N) - 8 digital inputs (6 for the position BCS of the tap changer + contact RAISE switching in increasing direction, contact LOWER switching in decreasing direction) Outputs - 3 analog outputs: (L1, L2, L3) for supplying the on load tap changer driving motor 3 x 380 V, 50 Hz - one digital output (open collector) for synchronization (active during a switching operation) - one serial output RS232 for data transmission