EC centrifugal fan - RadiCal

Similar documents
EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. backward curved

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC diagonal compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (flange)

onlinecomponents.com

AC axial compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

AC axial fan. sickled blades (S series)

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC axial compact fan

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

DC axial compact fan

Tangential Fans - Basic principles. Expertise, performance, innovation

EC/AC axial fans - HyBlade Ø

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 3252J/2H3PU

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 3254 J/2H3P

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet 6424/2HP-210

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet 8452/2 GHHP

Product Data Sheet 622/2HHP-021

Product Data Sheet 8214 J/2H4P

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Product Data Sheet DV4112/2NP-201

Soğutmada büyük beden modası

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

Specification For Approval

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

-1 ] temperature life [V]

175 mm 69 mm Specifications

NEW PRODUCT INFORMATION

NEW PRODUCT INFORMATION

C B. Models. Models 2MOPP

9WL type. Rated current Rated input. Rated speed [min -1 ]

Automotive BL-DC Fans for Commercial Vehicles. Edition

SPECIFICATION FOR APPROVAL

WL Product Range Performance Comparison

Technical guide. EC300 motor V8

J IPC IGBT power converter

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

INSTALLATION AND OPERATING INSTRUCTIONS

LED Driver Constant voltage

Specification For Approval

DB Motorized Impeller

Power supply CP-E 24/2.5

LED Driver Constant voltage

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Centrifugal Fan Product Range

Smart Power Relay E I...

DC Axial Fans. ebm-papst St. Georgen. Noise

Specification For Approval

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

EN 50178, IEC

Installation and Operating Instructions for Phase Demodulator Type _.2

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Power supply CP-E 24/20.0

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Safety switches with slotted hole lever

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Transcription:

ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 5944 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 594 Nominal data Type Motor MG55-BI Phase ~ Nominal voltage VAC Nominal voltage range VAC.. 4 Frequency Hz 5/6 Type of data definition ml Speed min - Power input W 8 Current draw A.75 Min. ambient temperature C -5 Max. ambient temperature C 6 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Item no. 5-5-998 Revision 89 Release 4-5-8 Page / 5

Technical features Mass Size Surface of rotor Material of electronics housing Material of impeller Number of blades 7 Direction of rotation. kg 9 mm Thick layer passivated Die-cast aluminium PA plastic Type of protection IP 54 Insulation class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Technical features EMC interference immunity Clockwise, seen on rotor "B" + 8 C - 4 C Any None, open rotor S Ball bearing - Output VDC, max.. ma - Tach output - Motor current limit - Soft start - Control input - VDC / PWM - Control interface with SELV potential safely disconnected from the mains - Over-temperature protected electronics / motor Acc. to EN 6-6- (industrial environment) EMC harmonics Acc. to EN 6--/ EMC interference emission Touch current acc. IEC 699 (measuring network Fig. 4, TN system) Motor protection Cable exit Protection class Product conforming to standard Approval Acc. to EN 55 (Class B, household environment), on account of the installation conditions, ferritic damping in the connection line may be required for the application. <=.5 ma Locked-rotor protection Variable I (if protective earth is connected by customer) EN 65-; CE CCC; EAC Item no. 5-5-998 Revision 89 Release 4-5-8 Page / 5

Product drawing Accessory part: Inlet nozzle 9576--4, not included in the standard scope of delivery Connection line PVC AWG, x brass lead tips crimped Connection line PVC AWG, 4 x brass lead tips crimped 4 Depth of screw max. 5 mm Item no. 5-5-998 Revision 89 Release 4-5-8 Page / 5

Connection screen No. Conn. Designation Colour Function / assignment CON L black Power supply VAC, 5-6 Hz, for voltage range refer to rating plate CON N blue Neutral conductor CON PE green/yellow Protective earth GND blue GND - Connection for control interface - V PWM yellow Control input - V or PWM, electrically isolated V/ max.ma red Voltage output V /. ma, electrically isolated, not short-circuit-proof 4 Tach white Tach output: open collector, pulse per revolution, electrically isolated, Isink max = ma Item no. 5-5-998 Revision 89 Release 4-5-8 Page 4 / 5

Charts: Air flow 5 Hz 85 5 5 pfs @ rho=, kg/m³ qv [CFM] 5 5 4 45,4 pfs [Pa] 8 75 7 65 6 55 5 45 4 4,,8,6,4,,8,6 pfs [InHO] Measurement: LU-5954 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 47 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 5 8,4, 5 7 5 5 6 5 4 4 qv [m³/h] 9 5 6 5 6 7,8,6,4, Measured values 4 5 6 7 8 9 4 5 6 U V f Hz 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 n min - 5 4 5 8 8 8 8 5 5 5 5 5 5 5 5 P ed W 8 8 8 8 49 5 57 5 4 6 8 6. I A.75.75.75.75.45.47.5.49.5.5.8.7.... qv m /h 75 65 455 55 58 55 4 5 445 95 65 75 5 5 p fs Pa 5 45 9 59 6 88 9 66 9 U = Supply voltage f = Frequency n = Speed P ed = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no. 5-5-998 Revision 89 Release 4-5-8 Page 5 / 5