EC centrifugal fan. forward curved, single inlet with housing (flange)

Similar documents
EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan - RadiCal

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan - RadiCal

AC axial compact fan

AC axial compact fan

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

AC diagonal compact fan

onlinecomponents.com

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC centrifugal fan. backward curved

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

AC axial fan. sickled blades (S series)

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

AC centrifugal fan - RadiCal

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

EC centrifugal fan - RadiCal

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

DC axial compact fan

Tangential Fans - Basic principles. Expertise, performance, innovation

EC/AC axial fans - HyBlade Ø

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 6424/2HP-210

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 3252J/2H3PU

Product Data Sheet 3254 J/2H3P

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet 8452/2 GHHP

Product Data Sheet 622/2HHP-021

Product Data Sheet 8214 J/2H4P

Soğutmada büyük beden modası

Product Data Sheet DV4112/2NP-201

Automotive BL-DC Fans for Commercial Vehicles. Edition

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Encoder - Absolut 2RMHF-SSI

Specification For Approval

NEW PRODUCT INFORMATION

Technical data. General specifications. Measurement range min max. 360

Specification For Approval

Lexium integrated drives

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

SPECIFICATION FOR APPROVAL

DB Motorized Impeller

-1 ] temperature life [V]

System protection by Vibration monitoring

Specification For Approval

Online data sheet DFS60A-TEPZ00S09 DFS60 INCREMENTAL ENCODERS

Specification For Approval

847H. Description. Features. Specifications

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

Zelio Control Measurement Relays

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

Solid-state Timer H3DS

Incremental encoders With blind or through hollow shaft pulses per revolution programmable

DB Motorized Impeller

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Online data sheet MAX48N-31V10K12500 MAX48 LINEAR ENCODERS

DB Motorized Impeller

Cooling Fans G-17. Cooling Fans G-17. AC Input/Low-Power Consumption EMU Series. AC Input/Compact Size MU Series

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

08/07/2015

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

DG 60 L Incremental Encoder

V: Very low speed, E: Extra low speed, L: Low speed, M: Middle speed, H: High speed, S: Super High speed, U: Ultra High speed, T: Top High speed

B1793 AC Blower Innovation in Motion

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

08/07/2015

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

Transcription:

ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59344 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 594 Nominal data Type Motor MG55-BD Nominal voltage VDC 4 Nominal voltage range VDC 6.. 8 Type of data definition Speed min - Power input W 4 Current draw A.9 Min. ambient temperature C -5 Max. ambient temperature C 6 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations fa Item no. 597-5-998 Revision 8585 Release 4-5-8 Page / 5

Technical features Mass Size Surface of rotor Material of impeller Housing material Direction of rotation.57 kg mm Type of protection IP Insulation class Humidity class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Technical features EMC interference immunity EMC interference emission Motor protection Cable exit Thick layer passivated Sheet steel, hot-galvanised Die-cast aluminium Clockwise, seen on rotor "B" F + 8 C - 4 C Any None S Ball bearing - Control input - VDC / PWM - Tach output - Motor current limit - Soft start Acc. to EN 6-6- (industrial environment) Acc. to EN 6-6-3 (household environment) Reverse polarity and locked-rotor protection Axial Product conforming to standard EN 695- Approval CSA C. Nr.77; EAC; UL 4- Item no. 597-5-998 Revision 8585 Release 4-5-8 Page / 5

Product drawing Connection line AWG, 4x brass lead tips crimped Item no. 597-5-998 Revision 8585 Release 4-5-8 Page 3 / 5

Connection screen No. Conn. Designation Colour Function / assignment GND blue Reference mass Tach white Speed monitoring output, pulses per rotation, Isink max = ma 3 - VDC yellow Control input Re > K 4 Un +4 VDC red Power supply 4 VDC, residual ripple 3.5 % Item no. 597-5-998 Revision 8585 Release 4-5-8 Page 4 / 5

Charts: Air flow Druck p f s[pa]für Rho=,kg/m^3 5 4 6 qv[cfm] 8 4 6 48 46 44 4 4 38 36 34 3 3 8 6 4 8 4 7 3,9,8,7,6,5,4,3,, pfs_e[in HO],9 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 3347 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. 8 6 4 6,8,7,6,5 8 6 4 4 6 8 4 6 qv[m^3/h] 8 9 4 5 6 8,4,3,, 3 Measured values 3 4 5 6 7 8 9 U V 8 8 8 8 4 4 4 4 6 6 6 6 n min - 38 675 35 335 48 73 94 75 895 5 5 P ed W 49 45 39 3 4 36 9 4 9 6 3 9.9 I A.9.8.54.3.9.64.34..3..9.78 qv m 3 /h 7 5 55 85 5 4 75 95 5 5 55 p fs Pa 64 348 48 4 8 33 8 55 78 U = Supply voltage n = Speed P ed = Power input I = Current draw qv = Air flow p fs = Pressure increase Item no. 597-5-998 Revision 8585 Release 4-5-8 Page 5 / 5