EC centrifugal fan - RadiCal

Similar documents
EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. backward curved

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, single inlet with housing (flange)

onlinecomponents.com

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

AC diagonal compact fan

AC axial fan. sickled blades (S series)

AC axial compact fan

EC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC axial compact fan

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

Tangential Fans - Basic principles. Expertise, performance, innovation

DC axial compact fan

Product Data Sheet RER225-63/18/2TDO- 406

EC/AC axial fans - HyBlade Ø

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet 3252J/2H3PU

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 3254 J/2H3P

Product Data Sheet 6424/2HP-210

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet 622/2HHP-021

Product Data Sheet 8452/2 GHHP

Product Data Sheet 8214 J/2H4P

Product Data Sheet DV4112/2NP-201

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Soğutmada büyük beden modası

Specification For Approval

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

-1 ] temperature life [V]

DB Motorized Impeller

NEW PRODUCT INFORMATION

NEW PRODUCT INFORMATION

Automotive BL-DC Fans for Commercial Vehicles. Edition

DC Axial Fans. ebm-papst St. Georgen. Noise

C B. Models. Models 2MOPP

175 mm 69 mm Specifications

9WL type. Rated current Rated input. Rated speed [min -1 ]

B1793 AC Blower Innovation in Motion

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL NOISE MEASUREMENT RELIABILITY PRODUCT LABEL...

EN 50178, IEC

SPECIFICATION FOR APPROVAL

WL Product Range Performance Comparison

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

DB Motorized Impeller

Specification For Approval

CUSTOMER: ARCERA EU MODEL NO: 9225 (CeraDyna Fan) PART NO: FD1290-AP181E3AL DATE: CUSTOMER APPROVAL. Taiwan. Page 1 of 12 REV.

Centrifugal Fan Product Range

Online data sheet DFS60A-TEPZ00S09 DFS60 INCREMENTAL ENCODERS

Split case double suction centrifugal pump. Technical data Serie: DPAS C

DB Motorized Impeller

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

INLINE flowmeter for continuous flow measurement

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

Rotary Measurement Technology Incremental Encoders

RoHS. High shaft load capacity. Shock / vibration resistant

KFS. Flap-type flow meter. Design and range of application

TRD-N/NH Series Incremental Encoders

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

DG 60 L Incremental Encoder

SPECIFICATION FOR APPROVAL

Specification For Approval

Transcription:

ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59344 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 5914 Nominal data Type Motor M3G55-DF Phase 1~ Nominal voltage VAC 3 Nominal voltage range VAC.. 4 Frequency Hz 5/6 Type of data definition ml Speed min -1 51 Power input W 17 Current draw A 1.4 Min. ambient temperature C -5 Max. ambient temperature C +6 ml = max. load me = max. efficiency fa = running at free air cs = customer specs cu = customer unit Subject to alterations Data according to ErP directive Installation category A Efficiency category Static Variable speed drive Yes Specific ratio * 1. * Specific ratio = 1 + p fs / 1 Pa Actual Request 13 Request 15 Overall efficiency η es 6.1 39.4 43.4 Efficiency grade N 78.7 58 6 Power input P ed kw.17 Air flow q v m³/h 15 Pressure increase p fs Pa 3 Speed n min -1 555 Data established at point of optimum efficiency Item no. 5115-5-998 Revision 7554 Release 1-11-6 Page 1 / 5

Technical features Mass Size Surface of rotor Material of electronics housing Material of impeller Number of blades 7 Direction of rotation 1.8 kg 5 mm Type of protection IP 54 Insulation class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Technical features Touch current acc. IEC 699 (measuring network Fig. 4, TN system) Motor protection Cable exit Protection class Thick layer passivated Die-cast aluminium Plastic PA6, fibreglass-reinforced Clockwise, seen on rotor "B" + 8 C - 4 C Shaft horizontal or rotor on bottom; rotor on top on request None, open rotor S1 Ball bearing - Output 1 VDC, max. 1.1 ma - Tach output - Motor current limit - Soft start - Control input -1 VDC / PWM - Line undervoltage detection - Over-temperature protected electronics / motor <= 3.5 ma Locked-rotor protection Variable Product conforming to standard EN 6335-1 I (if protective earth is connected by customer) Item no. 5115-5-998 Revision 7554 Release 1-11-6 Page / 5

Product drawing 1 Accessory part: Inlet nozzle 96359--413, not included in the standard scope of delivery Connection line PVC 4X.5 mm², 4 x brass lead tips crimped 3 Connection line PVC 3G.5 mm², 3 x brass lead tips crimped 4 Depth of screw max. 1 mm 5 Depth of screw max. 5 mm Item no. 5115-5-998 Revision 7554 Release 1-11-6 Page 3 / 5

Connection screen Line No. Signal Colour Function / assignment CON1 L black Power supply 3 VAC, 5-6 Hz, for voltage range refer to rating plate CON11 N blue Neutral conductor CON1 PE green/yellow Protective earth 1 GND blue GND - Connection for control interface - 1V PWM yellow Control input - 1 V or PWM, electrically isolated 3 1V/ max 1.1mA red Voltage output 1V/ 1.1mA, electrically isolated, not short-circuit-proof. 4 Tach white Tach output: open collector, 1 pulse per revolution, electrically isolated Item no. 5115-5-998 Revision 7554 Release 1-11-6 Page 4 / 5

Charts: Air flow 5 Hz Druck p f s[pa]für Rho=1,kg/m^3 74 7 7 68 66 64 6 6 58 56 54 5 5 48 46 44 4 4 38 36 34 3 3 8 6 4 18 16 14 1 1 8 6 4 1 1 qv[cfm] 3 4 5 6 7 8 9 1.,9,8,7,6,5,4,3,,1 4 1,9 1,8 8 1,7 3 7 1 11 16 6 15 1 14 3 4 5 6 7,1 13 9 5 1 8 9 1. 1.1 1. 1.3 1.4 1.5 1.6 1.7 qv[m^3/h] 1,6 1,5 1,4 1,3 1, 1,1 1,9,8,7,6,5,4,3, pfs_e[in HO] Measurement: LU-18144 Air performance measured as per ISO 581 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed. Measured values 1 3 4 5 6 7 8 9 1 11 1 13 14 15 16 U V 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 f Hz 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 n min -1 68 5 51 61 4 4 4 4 16 16 16 16 P ed W 146 17 17 16 14 14 14 15 6 81 8 7 31 41 4 37 I A 1.17 1.4 1.4 1.8.84 1.11 1.1 1..49.64..58.5.33.33.3 LpA in db(a) 68 63 59 6 58 64 61 58 54 6 57 53 49 55 LwA in db(a) 76 71 67 73 73 7 66 71 69 66 6 67 61 57 6 qv m 3 /h 155 15 975 56 135 1145 915 515 115 95 7 43 9 76 61 34 p fs Pa 35 5 176 39 43 1 14 94 78 137 188 U = Supply voltage f = Frequency n = Speed P ed = Power input I = Current draw LpA in = Sound pressure level inlet side LwA in = Sound power level inlet side qv = Air flow p fs = Pressure increase Item no. 5115-5-998 Revision 7554 Release 1-11-6 Page 5 / 5