SA210-Series Scanning Fabry Perot Interferometer

Similar documents
Constructing a Confocal Fabry-Perot Interferometer

Fabry Perot Resonator (CA-1140)

OPTI 511L Fall (Part 1 of 2)

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Notes on Laser Resonators

FFP-C Fiber Fabry-Perot Controller OPERATING INSTRUCTIONS. Version 1.0 MICRON OPTICS, INC.

Fabry-Perot Cavity FP1-A INSTRUCTOR S MANUAL

First Time User Manual

SA201, SA201-EC Spectrum Analyzer Controller. Operating Manual

FFP-TF2 Fiber Fabry-Perot Tunable Filter Technical Reference

Fabry-Perot Interferometer

Pound-Drever-Hall Locking of a Chip External Cavity Laser to a High-Finesse Cavity Using Vescent Photonics Lasers & Locking Electronics

LOPUT Laser: A novel concept to realize single longitudinal mode laser

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE

Ph 77 ADVANCED PHYSICS LABORATORY ATOMICANDOPTICALPHYSICS

Wavelength Control and Locking with Sub-MHz Precision

R. J. Jones Optical Sciences OPTI 511L Fall 2017

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

ECE 185 HELIUM-NEON LASER

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

B. Cavity-Enhanced Absorption Spectroscopy (CEAS)

Fabry-Perot Interferometer

Evaluation of Scientific Solutions Liquid Crystal Fabry-Perot Etalon

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

Understanding Optical Specifications

Table of Contents. LM-0300 Fabry Perot. Spectrum Analyzer. Introduction. Theory

DIODE LASER SPECTROSCOPY (160309)

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Experimental Physics. Experiment C & D: Pulsed Laser & Dye Laser. Course: FY12. Project: The Pulsed Laser. Done by: Wael Al-Assadi & Irvin Mangwiza

Optical Vernier Technique for Measuring the Lengths of LIGO Fabry-Perot Resonators

UNMATCHED OUTPUT POWER AND TUNING RANGE

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

Supplementary Materials

Multiply Resonant EOM for the LIGO 40-meter Interferometer

INDEX OF REFRACTION index of refraction n = c/v material index of refraction n

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

Bandpass Interference Filters

The Lightwave Model 142 CW Visible Ring Laser, Beam Splitter, Model ATM- 80A1 Acousto-Optic Modulator, and Fiber Optic Cable Coupler Optics Project

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

06SurfaceQuality.nb Optics James C. Wyant (2012) 1

UCI ZEEMAN EFFECT. Observe the fine structure lines of mercury and the Zeeman splitting of one or more of these lines as a function of magnetic field.

Spectrometer using a tunable diode laser

Spectroscopy of Ruby Fluorescence Physics Advanced Physics Lab - Summer 2018 Don Heiman, Northeastern University, 1/12/2018

MOI has two main product lines for its component business: 1. Tunable filters (FFP-TF, FFP-TF2, FFP-SI) 2. Fixed filters (FFP-I, picowave)

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

IST IP NOBEL "Next generation Optical network for Broadband European Leadership"

Frequency Scanned Interferometer Demonstration System

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers

Lecture 04: Solar Imaging Instruments

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

Introduction to the operating principles of the HyperFine spectrometer

A novel tunable diode laser using volume holographic gratings

CONFOCAL FABRY-PEROT INTERFEROMETER BASED HIGH SPECTRAL RESOLUTION LIDAR. David Swick Hoffman

ECEN 4606, UNDERGRADUATE OPTICS LAB

The VIRGO detection system

Lenses Design Basics. Introduction. RONAR-SMITH Laser Optics. Optics for Medical. System. Laser. Semiconductor Spectroscopy.

Advanced Features of InfraTec Pyroelectric Detectors

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

Universal and compact laser stabilization electronics

SECOND HARMONIC GENERATION AND Q-SWITCHING

Using Stock Optics. ECE 5616 Curtis

Optical Spectrum Analyzers

Opti 415/515. Introduction to Optical Systems. Copyright 2009, William P. Kuhn

Swept Wavelength Testing:

PC1141 Physics I. Speed of Sound. Traveling waves of speed v, frequency f and wavelength λ are described by

Frequency Scanned Interferometer Demonstration System

A fast F-number 10.6-micron interferometer arm for transmitted wavefront measurement of optical domes

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

MILLIMETER WAVE RADIATION GENERATED BY OPTICAL MIXING IN FETs INTEGRATED WITH PRINTED CIRCUIT ANTENNAS

Installation and Characterization of the Advanced LIGO 200 Watt PSL

Frequency Scanned Interferometer for LC Tracker Alignment

arxiv: v1 [physics.optics] 19 May 2016

Ph 77 ADVANCED PHYSICS LABORATORY ATOMIC AND OPTICAL PHYSICS

Single-frequency operation of a Cr:YAG laser from nm

Exam 3--PHYS 102--S10

Testing with Femtosecond Pulses

Construction and Characterization of a Prototype External Cavity Diode Laser

Stabilized Interrogation and Multiplexing. Techniques for Fiber Bragg Grating Vibration Sensors

High-frequency tuning of high-powered DFB MOPA system with diffraction limited power up to 1.5W

Operation of a broadband visible wavelength astrocomb with a high resolution astrophysical spectrograph: supplementary material

Actively Stabilized Scanning Single Frequency. Ti:Sa /Dye Ring Laser

Mode analysis of Oxide-Confined VCSELs using near-far field approaches

INTERFEROMETER VI-direct

Chapter 1 Introduction

Angular Drift of CrystalTech (1064nm, 80MHz) AOMs due to Thermal Transients. Alex Piggott

Observational Astronomy

Highly Reliable 40-mW 25-GHz 20-ch Thermally Tunable DFB Laser Module, Integrated with Wavelength Monitor

Tunable Laser Kits. Features

Advances in laboratory modeling of wave propagation

Eric B. Burgh University of Wisconsin. 1. Scope

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

Aberrations of a lens

Vertical External Cavity Surface Emitting Laser

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

TechNote. T001 // Precise non-contact displacement sensors. Introduction

Transcription:

435 Route 206 P.O. Box 366 PH. 973-579-7227 Newton, NJ 07860-0366 FAX 973-300-3600 www.thorlabs.com technicalsupport@thorlabs.com SA210-Series Scanning Fabry Perot Interferometer DESCRIPTION: The SA210 is a high finesse Spectrum Analyzer used to examine the fine structures of the spectral characteristics of CW lasers. The spectrum analyzer consists of a confocal cavity that contains two high reflectivity mirrors; by varying the mirror separation with a piezoelectric transducer the cavity acts as a very narrow band-pass filter. Knowing the free spectral range of the SA210 allows the time-base of an oscilloscope to be calibrated to facilitate quantitative measurements of a laser line shape. SPECIFICATIONS: Free Spectral Range 1 (FSR) Measured in milliseconds: FWHM Measured in microseconds: (FSR/FWHM) Actual Calculated Finesse: Maximum Input Voltage: 150V Free Spectral Range: 10GHz Minimum Finesse: >150 Resolution: > 67MHz Outer Housing Material: Black Anodized Aluminum Fabry Perot Cavity Material 2 : Low thermal expansion Invar Dimensions: Ø 1 Flange Total Length: 2.93 1 FSR is set by the length of the confocal cavity and is given by: FSR=c/4d. Where d= the radius of curvature of the mirrors; in this case d=7.5mm. (see drawing on next page). 2 A thermal design balances the small coefficient of thermal expansion of the Invar body with the negative coefficient of thermal expansion of the piezo actuators. Page 1 of 5

Confocal Cavity Configuration Mirrors shown below are AR coated on the outer surfaces and HR coated on the inner surfaces. FSR=c/4d Other mirror sets are available for this instrument: 525nm - 650nm 650nm - 800nm 780nm - 930nm 900nm - 1100nm 1250nm - 1400nm 1450nm - 1625nm SETUP: Knowing the FSR of the SA210 allows the time-base of an oscilloscope to be calibrated to facilitate quantitative measurements of laser line shape. With a resolution of 67MHz, the fine structure resulting from multiple longitudinal modes of a laser line can be resolved. Note: A saw tooth wave (0-20V) would provide approximately 2 Free Spectral Ranges. The SA210 should be mounted, so that it can be easily adjusted. It is recommended that Thorlabs 1- inch Kinematic Mount KM100 be used to mount the interferometer at the 1-inch diameter flange. The apparent beam size should be approximately 1mm. It is recommended that a fold mirror be used to direct the beam into the Fabry-Perot interferometer. A lens with focal length of 100mm can be used, with the focus set roughly at the center of the housing, approximately 25mm in from the flange. The maximum voltage on the piezo (ramp in) is not to exceed 150V. If the detector is connected directly to the scope, a 5kΩ terminator is needed. Offset adjustment (SA201) is used to center the output on the scope. OPERATION: To set up the SA210-Series Fabry-Perot you should first mount the unit into a tip/tilt mirror mount (Thorlabs part# KM100). Attach all of the connection according the drawing on page 4. Next you should remove the detector from the back of the unit and mount it in it s own mount, this will aid in the initial alignment. Then close the input iris and center your beam on the iris opening. Leave the back iris completely open and start to scan the unit. Now using the tip/tilt adjustment until the beam is center through the body of the SA210. Adjust the scope gain to maximum sensitivity, position the detector close to the rear opening and slowly close the back iris as you correct the 2 angular adjustments on the mirror mount. Once the beam is centered you can the replace the detector on the main body and start to use the unit for measurements. Page 2 of 5

OVER VIEW: Free Spectral Range To scan the spectra of the laser beam entering the Scanning Fabry Perot interferometer small displacement is applied to one of the cavity mirror mounted on piezoelectric transducers. This operation is done by fine tuning the ramp voltage applied to the Piezoelectric elements using the controller SA201. When the mirror spacing becomes equal to an integral number of half the wavelength of the laser, constructive interferences occur. That spectral response of the signal can be visualized with a scope. A series of periodical peaks appear on the screen of the scope. The distance between consecutive peaks is called the free spectral range (FSR) of the instrument. From a users perspective a confocal cavity has a FSR that is given by c/4d instead of c/2d as would be the case for a plano-plano cavity; the factor of 2 in the denominator can be understood by inspecting the ray trace shown below in Figure II. Note that a ray entering the cavity at a height h parallel to the optical axis of the cavity makes a triangular figure eight pattern as it traverses the cavity. From this pattern it is clear that the ray makes four reflections from the cavity mirrors instead of the two that would result in a plano-plano cavity. Hence the total roundtrip path through the cavity is given as 4d instead of 2d. Figure II Figure II: This figure shows a simplified ray-trace for a ray entering the cavity at height h. The curvature of the mirrors R and the separation being set precisely to R ensures that the input ray is imaged back onto itself after traveling a distance of approximately 4R. Additionally, in this configuration if a paraxial ray is traced through the system as shown in figure II, it is apparent that in the confocal configuration each mirror serves to image the other mirror back onto itself so that a ray entering the cavity will, after four traverses of the cavity, fall back onto itself, (note that the focal length of a spherical mirror is R/2). This imaging of the beam back onto itself greatly simplifies the alignment of the cavity; just align your input to within a few tenths of a millimeter of the center of the mirror set and restrict your input angles to less than a few degrees. The SA200 series interferometer has two iris diaphragms that simplify this alignment requirement. Finesse The finesse of the Scanning Fabry-Perot interferometer is a quantity which characterizes the ability of the interferometer to resolve closely spaced spectral features, it defines the resolution of the instrument. For an infinitely narrow input spectrum, the finesse determines the width of the measured spectrum. High finesse means high resolution capability, high finesse is obtained by increasing the reflectivity of the cavity mirrors. However, high reflective mirrors reduce the transmission of the interferometer. Page 3 of 5

In a typical application the SA210 Interferometer is used in conjunction with a signal generator and an oscilloscope, as shown below in figure III. A signal generator (Thorlabs SA201 Fabry-Perot Controller is used for generating the required scan signals for obtaining the data in this document) that can produce either a triangle or saw-tooth wave with an adjustable frequency (5 to 50 Hz), an adjustable amplitude (15 to 40 volts), and an adjustable offset. The signal generator is used to repetitively scan the length of the cavity by λ/4 in order to sweep through one FSR of the interferometer. An oscilloscope is typically used to view the spectrum and make quantified measurements of spectral features. Recommended Set-up MANUFACTURED BY WWW.THORLABS.COM MODEL #: SA201 S.N. MAX POWER 15W INPUT OUTPUT 115VAC 50-60Hz 125mA TYPE 'T' FUSE 230VAC 50-60Hz 63mA TYPE 'T' FUSE Figure III Figure III: This figure shows a schematic diagram of a typical setup that is used to measure the spectrum of a laser source. Please note that for this device to be useful the linewidth of the source must be less than the FSR of the interferometer. SPECTRUM ANALYZER CONTROLLER AND OTHER ACCESSORIES: The SA201 controller generates a voltage ramp, which is used to scan the separation between the two cavity mirrors. A photodiode is used to monitor transmission of the cavity. Using the output sync signal from the controller, an oscilloscope can be used to display the spectrum of the input laser. The controller provides adjustment of the ramp voltage (0 to 20V) and scan-time (1ms to 5s) to allow the user to choose Page 4 of 5

the scan range and speed. An offset control is provided to allow the spectrum displayed on the oscilloscope to be shifted right or left, zoom capability provides up to 100X increase in spectral resolution. Thorlabs KM100, 1 kinematic mount can be used to mount the SA210 Scanning Fabry Perot Interferometer. TECHNICAL SUPPORT: For further questions, or if you suspect a problem with your SA210, please contact Tech Support. An Applications Engineer will gladly assist you. Page 5 of 5