Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

Similar documents
P H Y S I C A L P R O P E R T Y M E A S U R E M E N T S Y S T E M. Quantum Design

6625A-QHR System COMPLETE QUANTUM HALL RESISTANCE SYSTEM 6625A-QHR FEATURES

Micro-manipulated Cryogenic & Vacuum Probe Systems

S600X SQUID M AGNETOMETER. S600X - For better magnetic measurements. The Better Choice. AC and DC measurements.

SPECIFICATIONS FOR A 4.7 TESLA/310MM BORE ACTIVELY SHIELDED MAGNET SYSTEM

TECHNICAL SPECIFICATIONS. FOR AN MRBR 7.0 TESLA / 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM

Ku-Band Receiver System for SHAO

MODEL INFORMATION 6800B

SPECIFICATION FOR A 7.0 TESLA/400MM ROOM TEMPERATURE BORE MAGNET SYSTEM

PPMS Physical Property measurement system Integrated measurement applications

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

SPECIFICATION OF SOLAR CELL TESTER

Cryogen-Free. Measurement System (CFMS) World Leaders in Cryogen-Free Technology.

SPECIFICATIONS FOR AN MRBR 7.0 TESLA / 210MM ACTIVELY SHIELDED MAGNET SYSTEM

7 Telsa SQUID Magnetometer

PRELIMINARY SPECIFICATIONS MRBR 7.0 TESLA / 210MM ACTIVELY SHIELDED CRYO-COOLED MAGNET SYSTEM

CALYS 75. Field documenting multifunction calibrator

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 100. Field precision documenting multifunction calibrator

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

MINI CRYOGEN-FREE MAGNET SYSTEMS 5-9 T (m-cfms)

CALYS 150. Advanced documenting multifunction calibrator thermometer

PURCHASE DIVISION DEPARTMENT QUALITY MANUAL Revision No. : 02 Issue No: : 2 Dt of Revision : Issue Dt. :

THE CRYOGENIC SYSTEM OF TESLA

XFEL Cryo System. Project X Collaboration Meeting, FNAL September 8-9, 2010 Bernd Petersen DESY MKS (XFEL WP10 & WP13) 1 st stage. Possible extension

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

STANDARD PRIMARY RESISTANCE QHR2000 A NEW STANDARD IN MEASUREMENT. Comparison of the 100 Ohm standard with RK to 1 part in 10 8.

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

Mhow (MP) PIN c/o 56 APO RFI : PROCUREMENT OF FAST TRANSIENT RESPONSE ELECTROMAGNETIC PULSE (EMP) SIMULATOR

CALYS 50. Field multifunction calibrator for basic use

Trillium US Inc. E500 Dual Channel Temperature Monitor User s Manual Rev A / November 2015

Trillium US Inc. E350 Temperature Monitor User s Manual Rev A / February 2016

Model 1140A Thermocouple Simulator-Calibrator

Pressure Transducer Handbook

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications.

AC Transport Option for the PPMS. 31 October, 2002

NI PXIe Contents. Required Software CALIBRATION PROCEDURE. Dual-Output Programmable DC Power Supply

High Accuracy 8-Pin Instrumentation Amplifier AMP02

Agilent Technologies 3000 Series Oscilloscopes

High Voltage Instrumentation Cables for the ITER Superconducting Magnet Systems

discovery in 1993 [1]. These molecules are interesting due to their superparamagneticlike

Model 6600A Dual Source High Resistance Bridge

Satellite Testing. Prepared by. A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai

TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS.

Subject; DC resistance and Magneto resistance measurement system. Refer to your enquiry for dc resistance and magneto resistance measurement system.

Bipolar Output Working Standard

MPI TS300-SE 300 mm Manual Probe System with ShielDEnvironment TM For accurate and reliable DC/CV, RF and mmw measurements

9200 Series, 300 MHz Programmable Pulse Generator

2520 Pulsed Laser Diode Test System

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

WATERFLUX 3000 Quick Start

ULTRAVOLT BIPOLAR HIGH POWER C SERIES

High Stability Voltage Source

TETRIS 1000 High Impedance Active Probe. Instruction Manual

SHMS Q2Q3Dipole Acceptance Test Plans Operations and Lessons Learned

TECHNICAL SPECIFICATION FOR ANNUBAR (DELTA TUBE)

Mechanical Design. Brian Brinson Mechanical Design Manager.

A few results [2,3] obtained with the individual cavities inside their horizontal cryostats are summarized in Table I and a typical Q o

Vibration studies of a superconducting accelerating

XSIS XE7S L0 HC/ACMOS OSCILLATORS FOR SPACE APPLICATIONS 500 KHz to 125 MHz. ( 5 x 7 mm, SMD, 3.3 V )

Basic Principles and Operation of Transformer

CEBAF Overview June 4, 2010

Cryogenics for Large Accelerators

FTTC05 Series LVDS TCXO/VCTCXO FOR SPACE APPLICATIONS 10M Hz to 1400MHz. ( 5 x 7 mm, SMD, 2.5 V )

RF STATUS OF SUPERCONDUCTING MODULE DEVELOPMENT SUITABLE FOR CW OPERATION: ELBE CRYOSTATS

Role of NI Products in Thermophysical & Optical Instrumentation

HA-2600, HA Features. 12MHz, High Input Impedance Operational Amplifiers. Applications. Pinouts. Ordering Information

Hardware. MRI System. MRI system Multicoil Microstrip. Part1

Tests of the Spoke Cavity RF Source and Cryomodules in Uppsala

Cryogenic Operations at SLAC

Ultra-Fast I-V Module for the Model 4200-SCS

Global Water Instrumentation, Inc.

Goyen 2000 Flue Gas Analyzer Two Sensors (O 2, CO)

CamGrind L. Key data. Superproductive and perfect for batch production. A member of the United Grinding Group

Precision OPERATIONAL AMPLIFIER

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass

Automatic Transformer Winding Analyser

Agilent Technologies 3000 Series Oscilloscopes

Hall Effect User Manual v1.0

FTM2 Series HCMOS/TTL OSCILLATORS FOR SPACE APPLICATIONS 0.5MHz to 160 MHz. ( 5 x 3.2 mm, SMD, 2.5 V )

OP490. Quad Low Voltage Micropower Operational Amplifier FEATURES: DESCRIPTION: Logic Diagram (One Amplifier)

RH1014M Quad Precision Operational Amplifier DESCRIPTIO PACKAGE INFORMATION BURN-IN CIRCUIT

4. Superconducting sector magnets for the SRC 4.1 Introduction

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

HA Features. 12MHz, High Input Impedance, Operational Amplifier. Applications. Pinout. Part Number Information. Data Sheet May 2003 FN2893.

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

B-Field Scanner. BENEFITS Easy to use Fits to a wide range of voice coil gaps Fully supported by Klippel RnD System Dedicated measurement software

Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

High Accuracy INSTRUMENTATION AMPLIFIER

1587/1577 Insulation Multimeters

Global Water Instrumentation, Inc.

WATERFLUX 3000 Quick Start

Standard Resistors Precision DC Shunts Digital Thermometers Non-inductive AC Shunts Intelligent Teraohmmeter Precision Decade Standards Precision Air

ABB Power Products Service

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Agilent Technologies 3000 Series Oscilloscopes

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Transcription:

Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled and user friendly. The instrument should be a proven one for multi- functional and capable of performing a broad range of measurements, including electric, magneto- electric transport, thermal transport and heat capacity, on bulk, thin- film, single crystal. Detailed specifications: (1) Basic unit 1) System should be cryogen- free, i.e. no requirement of liquid Helium and/or Liquid Nitrogen at any point of time. Both superconducting magnet and cryostat assembly should be cooled by 2-stage pulse tube cryocooler to cool both superconducting magnet and the temperature control system, and providing a low vibration environment for measurements. Small amount of helium gas for its fully automated start-up and operation. 2) Option of remote access to the system via internet must be enabled. 3) Any Liquid Helium and/or cold Helium gas flow into sample chamber or to any other parts within the system, and all low temperature operations must be handled in fully automated way through electronic and computer controls. 4) A dedicated window for monitoring cryostat status. 5) The system should be equipped with sufficient number of thermometers at different stages / locations and on cryocooler and magnet to monitor their temperatures through the main operating software. 6) The system must have a large temperature controlled region, or sample chamber, that can either be under vacuum or use various exchange gases. Material samples can be measured either with, or without, measurement probes giving users more flexibility in research design and scope. (2) Superconducting magnet with longitudinal field in the range of ± 9T a) ± 9Tesla field strength (longitudinal field) b) Sweep rate: Up to 20mT/sec. c) Field Homogeneity: ± 0.01 % over 3 cm on axis or better d) Field Stability: 1-2 ppm/hr e) Magnet has to be cooled by solid conduction without any liquid helium. f) Magnet ramping should not affect the temperature stability g) Thermometer directly on the magnet. Automatic discharge of the magnet if the cryocooler system fails (For example, due to water chiller failure.). h) Magnet control software monitors the temperature of the magnet and cryostat at various locations to ensure proper operation of the magnet system from quenches. i) Bi-polar power supply with over voltage protection and indication.

j) Various operating modes: Linear, Oscillating, No Overshoot must be given in details. There should be no overshoot in the field or the tolerable overshoot in No Overshoot mode should be specified for various field strengths. k) Magnet should be protected from quenches. (3) Temperature control: a) Cryostat assembly which will include sample chamber and radiation shields and other assembly must be cooled by counter flow heat exchange mechanism for efficient cooling and efficient use of cooling resources. All the operations must be fully automated without user intervention. b) The system should enable cooling of samples from highest temperature to the lowest at the highest specified cooling rate at any given magnetic field of up to ±9 T without affecting the system performance including the heating of magnet. The same procedures should be hold for heating of the samples as well. c) System should have sophisticated temperature control and provide seamless transition between high temperature (400 K) to low temperature. d) The sample chamber has to be sealed for controllable sample environment (static He gas, vacuum). e) Temperature range of 1.8 to 400 K with milli-kelvin stability and accuracy. f) Temperature stability should be at least ±0.5 % for T < 10 K and ±0.05 % for T > 10 K irrespective of the magnitude of applied magnetic field. g) Temperature of 1.9 K for the samples must be achieved from room temperature with a fast cooling (preferably 45 minutes). Sweeps through 4.2 K are smooth and monotonic on cooling and warming sequences. h) Accuracy: ± 1% and sweeping rate 0.01 to 30 K/min irrespective of the magnitude of applied magnetic field. i) Temperature control should be fully automated. j) Dual Helium impedance design (no mechanical cryogenic needle-valve) for continuous, fully automated, low temperature operation. Measurements at T < 4.2 K are possible for a continuous long time. k) Various modes of Fast settle, No overshoot, and sweep mode must be given in details. l) Required thermometers and heaters to manage temperature gradients and to ensure smooth temperature control throughout the accessible temperature range. (4) Vacuum pumps and fittings:

a) Vacuum pumps and fittings along with vacuum gauges, meter, standard vacuum coupling essential for the uninterrupted functioning of the instrument and its various measurements options must be included. b) All pumps must be dry pumps. (5) Data acquisition and analysis: a) Licensed windows based operating software and State- of- the- art computer control system compatible with the measurement options. Data acquisition system must be the latest version based on modular architecture (company must specify their data acquisition system). The software should be able to run the various measurement options automatically and in different modes. There must be a scope to control the external instruments by using different programs for the experiments designed by users. b) Fully automated measurements (except changing samples). Temperature, field control and sample measurement shall be fully automated. The software shall control all aspects of the instrument s electronics, hardware, gas handling, data acquisition and data analysis. The software shall include a comprehensive sequence editor for setting up unattended measurement runs. c) Remote user access to the system via Internet. d) The software must allow the users to remotely control and monitor experiments over any internet connection. e) System should have capability to control temperature and magnetic field from external programs like lab view or any other third party software. (6) Other accessories: Essential accessories/spares for the smooth operation of equipment for a period of 5 years should be quoted separately as an optional item. Measurements: 1. AC and DC transport: (a) 4-wire & 2-wire resistivity and simultaneous Hall effect measurement, I-V characteristics and differential resistance measurement (dv/di vs. I or dv/di vs V) (b) Should have two built-in independent sources and meters so that two measurement channels are truly independent. (c) In addition to standard mode (4-wire resistance up 10MΩ), there should be high impedance mode - 2-wire resistance measurement up to 5GΩ. (d) Current Source: DC & AC, 10nA (or less) to 100 ma (or more) or better continuous (1 Hz to 200hz or better for ac) (e) Sensitivity: 20 nv or better (f) 2 and 4 probe measurement capability

(g) Continuous measurements while slewing in temperature provide high density of data 2. Thermal Transport: (a) Temperature range 2K to 400K (b) Capability to measure thermal conductivity, seebeck coefficient, thermoelectric figure if merit (c) Required thermometers and heaters should be provided (d) Easy to use fully automated measurement (e) Calibrated sample should be provided preferably Nickel (f) Thermal conductance measurement accuracy: ± 5 % or better (g) Typical accuracy of the Seebeck coefficient: ± 5 % or better (h) Seebeck coefficient measurement range: 1 µv/k to 1 V/K or wider 3. Heat Capacity: (a) Temperature Range: 2 K 400 K, with a ± 0.1% between 2 K to 10 K.(Range need to be specified by the company) (b) Magnetic Field: ±9 Tesla (c) Relaxation technique, two-tau model fit analyses, corrections of back grounds from sample platform. (d) Sample Mass: typically few milligrams (e) Measurement Accuracy: 5% (or better) over 2K 300K (f) Heat Capacity resolution: less than 10 nj/mole.k at 2 K temperature (to be specified by the company and the claim need to be supported by references of the papers published and patents) (g) Thermometers on the platform 4. Multi- functional probe with sample stage and calibrated thermometer a. for low and high frequency dielectric constant measurements and electric polarization measurements in both with and without magnetic field configurations. b. with external electric leads to customize the equipment. This probe should be compatible with basic unit sample space electrical connections and should be able to utilize the electro-transport accessories 5. UPS: 40KVA Online UPS, 3 Phase input & 3 Phase output. 6. Chiller: Suitable water chiller should be provided

Future Upgrades: The system should be field upgradable to add options to Dilution Refrigerator, He3, FMR, Dilatometer, Optical probe etc. Other details. 1. Warranty 3 years from the date of installation and extended warranty for another 2 years 2. Other accessories Separate sample holders should be included in the basic unit. 3. Standard samples to be provided by the company for testing the instruments at the time of installation on site to the quoted accuracy in the given Tech-specs for the demonstration of the performance of equipment. 4. Please provide the segmented quotation for each optional measurement capability. 5. The bid should contain information about the requirement of helium gas replenishment. 6. The tender document should also indicate what kind of service/maintenance is required for the system. Whether this service has to be carried out by a company engineer or it can be carried by trained service personnel within India. 7. Bid should include all essential ancillary equipment and spares for its operation on turn- key basis on delivery (please provide list with details). 8. Power requirement: 230 V, 50 Hz. 9. Pre- installation site preparation requirements to be indicated and specified along with the bid. 10. Warranty period to be clearly mentioned and should begin from the date of installation. Annual Maintenance Contract should be clearly mentioned after warranty period. 11. Guaranteed specifications to be demonstrated at the time of installation. Any necessary standard samples for that purpose should be brought by the Service Engineers. 12. Installation and on site training of our staff in operation and maintenance is essential by factory trained personal free of cost. 13. Bid should include CIP Chennai prices. 14. Service manuals with complete circuit diagram and PCB layout for all equipment to be provided with the instrument. 15. Give Bankers name and address. 16. The vendor should have supplied and installed at least 5 similar instruments in the past 5 years in institutes like IIT/IISER/NIT s etc. List of similar systems installed during the last five years in India with contact person name, address, phone, fax and email Ids. 17. The vendor to provide compliance statement with respect to each technical specification in the tender document duly supported by the manufacturer s literature along with the technical bid. Any other claim will not be accepted and may lead to rejection of the bid. 18. Printed literature in support of compliance to the prescribed specifications is to be submitted. 19. In case during shipment period newer versions of software/hardware is available with vendor in lieu of the existing one for which Letter of Credit was opened, then improved version should be made available without any extra cost.

20. Technical evaluation by the Institute may include demonstration to verify functionalities and capabilities of the system quoted. Services: Vendor must submit Factory Acceptance Test procedure supported with relevant printed literature and certificates.