suppose we observed a 10 Jy calibrator with CARMA for 1 year, 24 hrs/day how much energy would we collect? S ηa Δν t

Similar documents
Coherent Receivers Principles Downconversion

Detector Systems. Graeme Carrad

A Crash Course in Radio Astronomy and Interferometry: 1. Basic Radio/mm Astronomy

Radio Telescope Receivers

Influence of Temperature Variations on the Stability of a Submm Wave Receiver

More Radio Astronomy

Receiver Performance and Comparison of Incoherent (bolometer) and Coherent (receiver) detection

Submillimeter (continued)

Signal Flow & Radiometer Equation. Aletha de Witt AVN-Newton Fund/DARA 2018 Observational & Technical Training HartRAO

hardware 3: phaselocks

The Cosmic Microwave Background Radiation B. Winstein, U of Chicago

IF/LO Systems for Single Dish Radio Astronomy Centimeter Wave Receivers

Sub-Millimeter RF Receiver. Sub-Millimeter 19Receiver. balanced using Polarization Vectors. Intrel Service Company

AVN Training HartRAO 2016

Guide to observation planning with GREAT

Heterodyne Receivers and Arrays

What does reciprocity mean

Antennas. Greg Taylor. University of New Mexico Spring Astronomy 423 at UNM Radio Astronomy

DESIGN AND CONSTRUCTION OF THE COSMIC MICROWAVE RADIOMETER

Sources classification

Cryogenic Systems and Receiver Maintenance

Ku-Band Receiver System for SHAO

Single Dish Observing Techniques and Calibration

NATIONAL RADIO ASTRONOMY OBSERVATORY CHARLOTTESVILLE, VIRGINIA. ELECTRONICS DIVISION INTERNAL REPORT No. 275 CRYOGENIC, HEMT, LOW-NOISE RECEIVERS

Introduction to Radio Astronomy!

MMA Memo 143: Report of the Receiver Committee for the MMA

System Considerations for Submillimeter Receiver

Antennas. Greg Taylor. University of New Mexico Spring Astronomy 423 at UNM Radio Astronomy

A Quick Review. Spectral Line Calibration Techniques with Single Dish Telescopes. The Rayleigh-Jeans Approximation. Antenna Temperature

Detectors. RIT Course Number Lecture Noise

A SUBMILLIMETER SIS RECEIVER COOLED BY A COMPACT STIRLING-YT REFRIGERATOR

ALMA Interferometer and Band 7 Cartridge

ngvla Advanced Cryocoolers For ngvla NATIONAL RADIO ASTRONOMY OBSERVATORY Larry D Addario, Caltech ngvlaworkshop, Socorro, 2017 June 26

To print higher-resolution math symbols, click the Hi-Res Fonts for Printing button on the jsmath control panel.

MMA RECEIVERS: HFET AMPLIFIERS

Lecture 6 Fiber Optical Communication Lecture 6, Slide 1

Chapitre 1. Introduction

Detection Beyond 100µm Photon detectors no longer work ("shallow", i.e. low excitation energy, impurities only go out to equivalent of

Holography Transmitter Design Bill Shillue 2000-Oct-03

ALMA Sensitivity Metric for Science Sustainability Projects

THEORY OF MEASUREMENTS

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

Introduction to Radio Astronomy. Richard Porcas Max-Planck-Institut fuer Radioastronomie, Bonn

A Method for Gain over Temperature Measurements Using Two Hot Noise Sources

Spectral Line Calibration Techniques with Single Dish Telescopes. K. O Neil NRAO - GB

Where detectors are used in science & technology

Electronics Division Technical Note No Modular Analysis Software for the ALMA Front End Test and Measurement System

The 4mm (68-92 GHz) Receiver

Chapter 3. Instrumentation. 3.1 Telescope Site Layout. 3.2 Telescope Optics

Antennas and Receivers in Radio Astronomy

Exercise 1: RF Stage, Mixer, and IF Filter

Etude d un récepteur SIS hétérodyne multi-pixels double polarisation à 3mm de longueur d onde pour le télescope de Pico Veleta

The WVR at Effelsberg. Thomas Krichbaum

Heterodyne Receivers

Skoog Chapter 1 Introduction

5 RECEIVERS TABLE TBD: EVLA RECEIVER FREQUENCY RANGES AND OPERATING TEMPERATURES


J/K). Nikolova

Design of a Sideband-Separating Balanced SIS Mixer Based on Waveguide Hybrids

Millimeter and Submillimeter SIS Mixers with the Noise Temperature Close to the Quantum Limit

ANALOG COMMUNICATION

ALMA MEMO #360 Design of Sideband Separation SIS Mixer for 3 mm Band

EXAMINATION FOR THE DEGREE OF B.E. and M.E. Semester

THE CRYOGENIC SYSTEM OF TESLA

of-the-art Terahertz astronomy detectors Dr. Ir. Gert de Lange

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Based on lectures by Bernhard Brandl

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

AGRON / E E / MTEOR 518 Laboratory

The ALMA Front End. Hans Rudolf

Satellite TVRO G/T calculations

Photomixer as a self-oscillating mixer

Micro-sensors - what happens when you make "classical" devices "small": MEMS devices and integrated bolometric IR detectors

NEWTON TRAINING (2018):

1. What is the unit of electromotive force? (a) volt (b) ampere (c) watt (d) ohm. 2. The resonant frequency of a tuned (LRC) circuit is given by

System Noise Power 1

10 GHz Microwave Link

Multibeam Heterodyne Receiver For ALMA

R. J. Jones Optical Sciences OPTI 511L Fall 2017

Chapter 1 Introduction

Ultra-sensitive, room-temperature THz detector using nonlinear parametric upconversion

OPTOELECTRONIC and PHOTOVOLTAIC DEVICES

Lecture 18: Photodetectors

SUPPLEMENTARY INFORMATION

Sideband Smear: Sideband Separation with the ALMA 2SB and DSB Total Power Receivers

The Heterodyne Instrument for the Far-Infrared (HIFI) and its data

Lecture 6 SIGNAL PROCESSING. Radar Signal Processing Dr. Aamer Iqbal Bhatti. Dr. Aamer Iqbal Bhatti

Calibration. Ron Maddalena NRAO Green Bank November 2012

Mercury Cadmium Telluride Detectors

EVLA Memo #119 Wide-Band Sensitivity and Frequency Coverage of the EVLA and VLA L-Band Receivers

Noise and Distortion in Microwave System

THE ARO 0.4mm ( GHz) SIS MIXER RECEIVER. Revision 1.0

ALMA MEMO 399 Millimeter Wave Generation Using a Uni-Traveling-Carrier Photodiode

Very Long Baseline Interferometry

THIS IS A NEW SPECIFICATION

Diode conducts when V anode > V cathode. Positive current flow. Diodes (and transistors) are non-linear device: V IR!

Instruction manual and data sheet ipca h

Lecture 4 Fiber Optical Communication Lecture 4, Slide 1

ALMA water vapour radiometer project

Sideband-Separating SIS Mixer at 100GHz Band for Astronomical Observation

Transcription:

3 hardware lectures 1. receivers - SIS mixers, amplifiers, cryogenics, dewars, calibration; followed by antenna tour; later, take apart a 6-m dewar 2. correlator (James Lamb) 3. local oscillator system - Gunn oscillator, phaselock chain, linelength system, lobe rotation, sideband separation

receivers radiation collected by the telescope is focused onto a feed horn that couples it into a waveguide the receiver amplifies and converts some frequency range of the incoming signals to a lower frequency IF (intermediate frequency) that is sent back to the control building

suppose we observed a 10 Jy calibrator with CARMA for 1 year, 24 hrs/day how much energy would we collect? E = 1 2 S ηa Δν t S = source flux density = 10 Jy = 10 x 10-26 watts m -2 Hz -1 the factor of ½ arises because we are sensitive to 1 polarization η = aperture efficiency ~ 0.60 A = geometrical collecting area = 6 x 85 m 2 + 9 x 29 m 2 = 771 m 2 Δν = instantaneous bandwidth = 2 x 4.0 GHz = 8 x 10 9 Hz t = 1 year = 3 x 10 7 sec Result: E = 5.6 x 10-6 joules 1 calorie = 4.2 joules heats 1 cm 3 (20 drops?) of water by 1 C must observe for 38000 years to heat 1 drop of water by 1 C

1. bolometers detectors for radio astronomy absorbed photon increases temperature, changes resistance phase of incoming signal is lost unsuitable for aperture synthesis operate at ~0.3 K 2. HEMT (High Electron Mobility Transistor) amplifiers preferred below 50 GHz, good up to 115 GHz operate at ~20 K 3. SIS mixers mixes incoming signal with local oscillator to convert it to a lower frequency where it is amplified (by HEMT) preferred for 100+ GHz operate at ~4 K

High Electron Mobility Transistor (HEMT) amplifier source gate 0.1 µm = 1000 Å drain gate voltage controls width of channel, modulates current from source to drain to operate at 100 GHz, charge carriers must transit under the gate in ~ 1/10 x 1/100 GHz ~ 10-12 sec must travel 0.1 um in 10-12 sec ~ 100 km s -1 in HEMT (but not in FET), current travels through very pure layer -> no scattering by impurities

mixers are used to convert signals to a lower frequency mix RF (radio frequency) signal with a strong LO (local oscillator) to produce an IF (intermediate frequency) e.g., 102 GHz RF + 100 GHz LO -> 2 GHz IF (also, 98 GHz RF + 100 GHz LO -> 2 GHz IF) can be thought of as sampling the incoming signal; local oscillator is the clock

mixer has a nonlinear current-voltage relation linear device (superposition principle): linear ω 1, ω 2 ω 1, ω device 2 nonlinear device: nonlinear ω 1, ω 2 ω 1, ω 2, ω 1 +ω 2, ω 1 -ω 2, 2ω 1 +ω 2,... device diode is an example of a nonlinear device: I = I 0 (e αv 1) ~ I 0 (αv + ½ α 2 V 2 +..) V = A cosω 1 t + B cosω 2 t V 2 = A 2 cos 2 ω 1 t + B 2 cos 2 ω 2 t + 2AB cosω 1 t cosω 2 t +... =... + AB cos(ω 1 + ω 2 )t + AB cos(ω 1 ω 2 )t +... note: amplitude at frequency ω 1 -ω 2 is linearly related to amplitudes A and B

waveforms local oscillator (LO) signal just random noise for radio astronomy LO + signal (voltage in diode) current through diode IF after low pass filtering

DSB (double sideband) downconversion sky frequency HCN 88.6 LSB LO 93.3 CS 98.0 USB 1 9 intermediate frequency (I.F.) upper and lower sidebands are folded together in the I.F. e.g., HCN at 88.6 and CS at 98.0 both appear at 4.7 GHz in the I.F. but can be separated by phase switching (lecture 3) LO tunable from 85-114 GHz (3mm) and 215-270 GHz (1mm) SZA 3mm receivers are different USB only

SIS (Superconductor-Insulator-Superconductor) tunnel junctions used as mixers at mm wavelengths AlO insulating layer, 10Å thick Nb Nb SIS junction cross section operate at 4 Kelvin photographs of SIS device with matching circuitry

SIS devices have extremely sharp nonlinearity V tunneling current Fermi level filled states I V normal metal: tunneling barrier looks like a resistor energy gap Josephson tunneling 2.8 mv for Nb superconductor; no single particle current until V > energy gap; produces sharp nonlinearity photon-assisted tunneling across barrier (1 mev= hν for ν = 242 GHz)

I-V curves for SIS device (series array of 4 junctions) unpumped and pumped with 240 GHz L.O. 4 hν/ke = 4 mv

cryocooler and dewar cryogenic refrigerator

closed cycle 4 K cryocoolers similar to Carnot cycle: compress helium to ~280 psi, air-cool to remove heat of compression in the cold head, expand to ~60 psi to provide refrigeration except: use heat exchangers (bronze screens, Pb spheres, Er 3 Ni spheres) in the cold head to reduce the pressure difference that is needed above the critical pressure of ~30 psi, 4 K helium does not separate into gas and liquid phases it is a dense fluid

cryocoolers - practical details on 6-m antennas, must slow down the cold head cycle to get to lowest temperatures; 72 rpm during cooldown to 5 K, 30 rpm to operate at 3 to 3.8 K contaminants in helium gas stream ultimately freeze out at 4 K, lead to erratic operation; 5 minute defrost cycle can help; every 6-12 months warm to room temperature, flush with fresh helium oil is injected into gas stream in the compressors to absorb heat of compression; overheating most likely in extremely cold weather when oil gets viscous

dewar design to minimize heat load on cryocooler: evacuate to minimize gas conduction; pressure < 10-9 atm, ~ a few x 10 10 cm -3 use low thermal conductivity materials; a copper wire 24 long x.022 diam would conduct 50 mw from room temp to 4 K copper shields reduce loading from room temperature radiation (300 mw/sq in for a 300 K black body)

local oscillators LO = microwave signal on each receiver that mixes with incoming radio signal LO frequency is tunable, determines what spectral chunks are sent back to the control building on the IF LOs must be perfectly synchronized on all telescopes phaselocked to reference signals sent from the lab (a servo system; subject of hardware lecture 3) beamsplitters combine signal and LO

fiberoptic links signals between antenna and control building travel over glass fibers in underground conduits transmitter: intensity-modulated IR laser receiver: photodiode measures laser intensity 8 fibers per antenna: 2 Ethernet, 2 IF, 4 phaselock reference signals reconnect fibers in antenna base and in control building each time an antenna is moved

receiver calibration amplifies signal, preserving its phase measures power (no phase) horn rcvr detector V out = G (T in + T rcvr ) (volts or counts) T in T rcvr black body emitters are the most convenient calibration sources (K instead of ergs cm -2 s -1 Hz -1 ); power collected in 1 polarization by horn with aperture D is: P in = 1 2 B A ΔΩ Δυ = 1 2kT λ 2 D 2 Δυ = ktδν 2 λ 2 2 D T rcvr is the noise generated by the receiver, referred to the input of the receiver

receiver calibration V out 295 K in the lab, use black body emitters at room temperature (295 K) and immersed in LN 2 (77K) 77 K solve for gain G and receiver temperature Trcvr Trcvr T in Tsys = Tin + Trcvr is the total noise power from the receiver, calibrated as an input temperature

calibration for astronomical objects ideally, calibrate with loads outside the atmosphere unfurl a 200 x 200 m load from the space station? nature provides T 1 = CMB effective temperature of T 2 at the input to the receiver: T 2 = T2 e τ + T atm (1 e τ ) so if T 2 = T amb, it doesn t matter where we position the load along the line of sight it can be right in front of the receiver!

more notes on chopper wheel cal effectively, we are including the atmosphere as part of the receiver: hence, we can t tell the difference between a poor receiver and a rainy day both lead to high Tsys (but we have 15 antennas, so spotting bad rcvr is easy) as long as Tamb Tatm, the effective calibration temperature Tcal depends only weakly on the details of the atmospheric model receivers are sensitive to 2 bands (LSB and USB); normally Tsys(LSB) = Tsys(USB) = 2 Tsys(DSB) reference: Ulich & Haas 1976

remember that T sys is the AVERAGE noise power fluctuations in Tsys: ΔT = Tsys Δυ τ so fluctuations are greater on ambient load or the Sun than on cold sky fluctuations in Tsys