Alternative to Germanium Gaining Momentum for IR Optics

Similar documents
Visible Improvements to Non-Visible Imaging Systems: Improving Efficiency with Precision Molded Chalcogenide Glass Components

LightPath. Infrared Optics. Leaders in aspheric optics and assemblies TECHNOLOGIES

PRECISION LENS MOLDING OF CHALCOGENIDE OPTICS. Jayson J. Nelson 22 Apr 2015

Using molded chalcogenide glass technology to reduce cost in a compact wide-angle thermal imaging lens

Next generation IR imaging component requirements

capabilities Infrared Contact us for a Stock or Custom Quote Today!

The Design, Fabrication, and Application of Diamond Machined Null Lenses for Testing Generalized Aspheric Surfaces

INFRARED IMAGING-PASSIVE THERMAL COMPENSATION VIA A SIMPLE PHASE MASK

Aspheric Lenses. Contact us for a Stock or Custom Quote Today! Edmund Optics BROCHURE

ABSTRACT. Keywords: Panomorph lens, panoramic, lens design, infrared, LWIR, situation awareness, image rendering 1. INTRODUCTION

WHO WE ARE. Key data. Legal form: privately held joint stock company with registered shares. Production area: m² (45251,48 ft²) Employees: 280

A fast F-number 10.6-micron interferometer arm for transmitted wavefront measurement of optical domes

CORPORATE PRESENTATION

WELCOME TO EO ISRAEL EVENT

Dual band antireflection coatings for the infrared

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Sensors & Applications Glass Industry. More Precision

REOSC PIXELATED AND ADVANCED IR COATINGS

Specifications. Optical grade germanium single crystals

Developments in Precision Asphere Manufacturing Jay Tierson, Ed Fess, Greg Mathews OptiPro Systems LLC, 6368 Dean Parkway, Ontario NY 14519

Moulded Optics standard aspheres

Practical Guide to Specifying Optical Components

COLOUR INSPECTION, INFRARED AND UV

The RSH Catalogue. CO2 Laser Optics/Consumables - Lenses

Converging Lenses. Parallel rays are brought to a focus by a converging lens (one that is thicker in the center than it is at the edge).

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Lenses Design Basics. Introduction. RONAR-SMITH Laser Optics. Optics for Medical. System. Laser. Semiconductor Spectroscopy.

Precision Folding Technology

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

Optimization of Process Parameters to Achieve Nano Level Surface Quality on Polycarbonate

Compact Dual Field-of-View Telescope for Small Satellite Payloads

Understanding Optical Specifications

Near-IR cameras... R&D and Industrial Applications

Rochester Precision Optics. Problem Solved. Standard molded and machined lens components and assemblies for rapid prototyping and volume production.

FRAUNHOFER INSTITUTE FOR PHOTONIC MICROSYSTEMS IPMS. Application Area. Quality of Life

The Optical Solutions Company

Classical Optical Solutions

Development and Applications of a Sample Compartment FTIR Microscope

For rotationally symmetric optical

TECHNICAL QUICK REFERENCE GUIDE MANUFACTURING CAPABILITIES GLASS PROPERTIES COATING CURVES REFERENCE MATERIALS

Global Manufacturer of Innovative Ultra Precision Machining Solutions Solutions for Aerospace and Defense

Chalcogenide Letters Vol. 7, No. 11, November 2010, p

Tunable wideband infrared detector array for global space awareness

New opportunities of freeform gratings using diamond machining

TMT Segment Polishing Principles

ATS 200 & ATS 400 Alignment Turning Stations with Ful y Integrated Measurement Technology

Performance Factors. Technical Assistance. Fundamental Optics

EUV Plasma Source with IR Power Recycling

Practical Plastic Optics

Manufacturing Process of the Hubble Space Telescope s Primary Mirror

Properties of Structured Light

MicroSpot FOCUSING OBJECTIVES

INVESTIGATION OF IMPROVED LABEL CUTTING BY CO 2 LASERS WITH WAVELENGTH OPTIMIZATION Paper #2004

Vixar High Power Array Technology

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

THE CUSTOM TOOLING PROCESS AT LOWELL, INC.

Glass-Technology International 1/1999

Beam expansion standard concepts re-interpreted

Optics Manufacturing

Glass Membrane Mirrors beyond NGST

SPIE Volume 472 PRECISION OPTICAL GLASSWORKING. A manual for the manufacture, W. Zschommler. Glasbearbeitung (Werkkiinde fur den Feinoptiker)

The Renishaw Additive Manufacturing formula

OPTICS DIVISION B. School/#: Names:

DIMENSIONAL MEASUREMENT OF MICRO LENS ARRAY WITH 3D PROFILOMETRY

Industrial quality control HASO for ensuring the quality of NIR optical components

Coherent Laser Measurement and Control Beam Diagnostics

Optics for the 90 GHz GBT array

Infra Red Interferometers

Fabrication of 6.5 m f/1.25 Mirrors for the MMT and Magellan Telescopes

Short Wave Infrared (SWIR) Imaging In Machine Vision

A LEADER IN OPTICAL TECHNOLOGY. GRADIUM Lenses.

Photonic device package design, assembly and encapsulation.

Lecture Outline Chapter 27. Physics, 4 th Edition James S. Walker. Copyright 2010 Pearson Education, Inc.

CINEMA FILTERS. nisifilters.com.au nisifilters.co.nz

Geltech Aspheric Lenses

Technical Report Synopsis: Chapter 4: Mounting Individual Lenses Opto-Mechanical System Design Paul R. Yoder, Jr.

High Resolution 640 x um Pitch InSb Detector

Photolithography II ( Part 2 )

The Importance of Wavelengths on Optical Designs

Material analysis by infrared mapping: A case study using a multilayer

Hermetic Packaging Solutions using Borosilicate Glass Thin Films. Lithoglas Hermetic Packaging Solutions using Borosilicate Glass Thin Films

Image Formation. Light from distant things. Geometrical optics. Pinhole camera. Chapter 36

Fabrication Methodology of microlenses for stereoscopic imagers using standard CMOS process. R. P. Rocha, J. P. Carmo, and J. H.

Low Refractive Index Coating and Index Matched Adhesive Bonding for Lightguide Applications

1.1 Singlet. Solution. a) Starting setup: The two radii and the image distance is chosen as variable.

Unit 3: Chapter 6. Refraction

Laser Diode Mounting Kits

FRESNEL LENS TOPOGRAPHY WITH 3D METROLOGY

GlassSpection User Guide

Design of the cryo-optical test of the Planck reflectors

LASER TECHNOLOGY. Key parameters. Groundbreaking in the laser processing of cutting tools. A member of the UNITED GRINDING Group

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Feature-level Compensation & Control

Including 12µ Compatible Lenses

Broadband Optical Phased-Array Beam Steering

Filters for Dual Band Infrared Imagers

MEMS Spectroscopy Overview

German Photonics Industry - Products & Innovations SPIE Photonics West Exhibition, 5-7 February 2013

The Nature of Light. Light and Energy

Mercury Cadmium Telluride Detectors

Transcription:

Alternative to Germanium Gaining Momentum for IR Optics Chalcogenides are fast becoming the material of choice, thanks to advances in system modeling tools and metrology techniques, combined with the efficiencies of precision glass molding. When it comes to designing IR imaging systems, manufacturers have traditionally worked with crystalline materials such as germanium. To make compact, lightweight systems, fabricators are driven to use aspheric surfaces, which has meant diamond turning. Chalcogenide glasses have emerged as another material option for IR optical elements. Not only do they A military night vision sensor product deployed in the field. 1

boast excellent performance, but, even more importantly, they can be fabricated using scalable precision glass molding methods. Several technologies are converging to enhance the capabilities of IR imaging systems. Advances in detectors provide useful options to system designers from the short-wave infrared (SWIR) through mid-wave (MWIR) and to long-wave (LWIR). System modelling tools are matching that improvement, and it is now possible to predict the performance of complex systems, as well as model intricate surfaces. At the same time, advances in metrology techniques makes it possible to validate individual components and overall system performance at each stage of the development process. These advances mirror those of optics for visible systems, with the important exception that many key materials that are transparent in the visible are opaque in the IR, so IR systems must use alternates. Traditional IR optical elements are composed of crystalline materials such as Ge, ZnS, ZnSe and Si, which can be diamond turned and conventionally ground and polished. Improved fabrication techniques now allow for creation aspheric surfaces; this allows for compact, lightweight designs. All of these attributes have come together to create growing interest in IR imaging systems, suitable for surveillance, security and guidance. Single-point diamond turning is a well-accepted and established precision manufacturing method for IR optics, however economies of scale require purchasing additional machines and global production capacity is limited. Designers have been stuck with expensive and slow diamond turning all throughout the production run. Additionally, the ten-thousandth optical element would take almost as much time to produce and validate as the first or the tenth because each part is uniquely produced. Benefits of precision glass molding Chalcogenide glass (ChG) optical elements can be diamond turned, but they can also be produced with precision glass molding (PGM). After up-front design, engineering and mold production, PGM elements can be produced quickly, and the ten-thousandth element is identical to the tenth. Once the tool has been validated, the inspection requirements for successive production runs become straightforward. This opens up the opportunity for designers to take advantage of economies of scale for serial production quantities. That is, they can produce prototype and qualification runs with optical elements composed of traditional materials, and then modify the design for ChG and ramp up to production quantities But the real opportunity is much more significant. Designers can produce prototypes, qualification systems, and production runs all from the same ChG material. There s no barrier to entry into the streamlined design and production world of chalcogenide glass IR element production other than a lack of familiarity with PGM as a manufacturing method and ChGs as IR materials. In precision glass molding, glass is heated until it softens and then is compressed between two molds under force. Precision glass molding is suitable for glasses that have relatively low 2

glass transition temperatures. Chalcogenide glasses have an advantage over visible light glasses because they have lower transition temperatures, so molding can be done more easily. The PGM process cools the glass from its molding temperature down to room temperature. Due to the thermal cycling of the glass, molded optics have what is called index drop, which The molds for ChGs are often produced by diamond turning, which means the same precision aspheric surfaces coming from diamond turning an individual part are transferred to each of the many molded copies. Inflection points, tight radii of curvature, and other small design features are usually not a problem. PGM-produced components do have some constraints on their center- to edge-thickness ratio, generally related to factors such as residual stress in the material and shrinkage. Thickness also affects the heating and cooling time and may drive component price. Very sharp corners and rapid thickness transitions can be problematic, but if those types of features are called upon for precision mounting, they can be incorporated with standard post-molding processes. PGM parts can either be molded to their final diameter or pressed bigger than the finished part diameter and then centered. Diamond turned parts can t get much smaller than 5 mm in diameter, as it becomes increasingly difficult to attach the blank to the chuck, but precision glass molded elements have no theoretical lower limit, although lenses as small as 1,5 mm in diameter are a typical minimum. A reasonable upper limit for molded parts is about 35 45 mm in diameter, although larger diameters are possible. One of FISBA s Toshiba precision glass molding machines with IR heater on. means the finished optics don t have the same index as the catalog specification for fine annealed glass. The index drop is repeatable and well characterized, so the effect is easily included in design models. PGM lowers the cost per piece and the component processing time. Initial costs are relatively high because of the Non-Recurring Engineering Costs (NRE) for tooling, but somewhere in the thousand to several thousand part range the reduced per piece costs outpace the initial investment. And when considering going to high volumes, planning for PGM down the line makes it easier to transition from fabrication of prototypes and qualification units into production, because no drawing or material changes are needed. Group 16 In 1932 two German scientists, Wilhelm Blitz and Werner Fischer, proposed the name chalcogen for the elements in Group 16 on 3

the periodic table. Those elements include oxygen, sulfur, selenium, tellurium and polonium. Sulfur (S), selenium (Se) and tellurium (Te) are the chalcogens that form chalcogenide compounds that can be made into IR optical glass. Chalcogenide glasses are comprised of Chalcogen compounds arranged in an amorphous network with no long range order. Dual element glasses such as As2Se3 have a 3D-like structure held together by Van der Waals forces, while ternary or more complicated ChG glasses are crosslinked by stronger interatomic bonds. The unique chemical and physical properties of chalcogenides make them attractive candidate materials for IR optics. The five to seven mainstream industrial flavors of chalcogenide glasses all have high transmission over a wide wavelength range (from about 1 µm to 12 to 14 µm), an index of refraction broadly comparable to traditional IR materials, and lower melting and glass transition temperatures than visible glasses so they are an excellent fit for PGM. The physical properties of the material also make them workable with diamond turning and conventional grinding and polishing methods. There are some variations among nominally identical chalcogenide glasses from different suppliers, primarily depending upon how much the suppliers purify the arsenic, selenium, or other elements prior to synthesizing the chalcogenide. These different formulation processes don t modify the material properties significantly, except for extending the long-wave transmission window cutoff from 12 µm to 14 µm in certain cases. Another key advantage chalcogenides hold over germanium is the lack of thermal darkening. Heated above 65 C Germanium becomes opaque in the IR. ChGs are stable to + 100 C or greater depending on the composition. Mechanical hardness is about the only area where ChGs aren t advantageous over germanium, but with hard coating, chalcogenide glasses can be just as robust. Component designers need to incorporate the PGM index drop into their models, but that s not as complex as it might appear. Although the Precision molded IR lenses and a ball preform made from chalcogenide glass. heating and cooling cycle of molding lowers the index of refraction from that of the fine-annealed raw material, there s not much difference between the index profiles for parts created with different cooling profiles. The actual cooling profile tends to be dominated by the very low thermal conductivity of chalcogenides, self-limiting the cooling rate and evening out differences between distinct PGM parts. The bottom line: as long as designers include the index drop in the material description of their modelling program with measured data available, the design and simulation will be accurate. 4

Large-scale product of detailed Precision glass molding is not often cost-effective for spherical surfaces custom tooling for grinding and polishing is usually the way to go for spheres. PGM excels for moderate- to large-scale production of complex and detailed parts. For example, if an optical element has two aspheric surfaces, the proper relative orientation of the two surfaces is critical to reach performance goals. With traditional fabrication and metrology methods, the orientation of each surface must be individually measured and controlled. With PGM, once the tool (the mold) has been qualified, the job is done. IR diffractive optical elements (DOEs) are also excellent candidates for PGM-fabricated chalcogenides. Small and sharp features are cut into the tool with diamond turning, and then those features are reproduced in each part. The same advantages apply to freeform components once the tool has been qualified, production runs are efficient and straightforward. IR system design is inherently a complex and intricate process, and optical component design An IG6 molded aspheric diffractive lens with AR coating (~ 25 mm) and a 2,5 mm IG5 biconvex collimation lens. is often the most critical element of an entire project. Performance predictions must be validated with prototypes, then manufacturing protocols must be verified with qualification units, and finally the performance of the qualification units must be transferred to large-scale production units. When designers incorporate production-phase requirements into their prototype designs the overall process becomes dramatically simplified. There is no question that moderate- to large-scale production runs are more efficient with precision glass molded chalcogenide glass components. Keeping that endpoint in mind, designers can make prototype ChG parts with diamond turning or traditional grinding and polishing, but with design features that seamlessly transition to PGM.Foresight in early stages eliminates many of the hurdles of changeover from qualification to production, improves efficiency, and reduces cost over the entire product lifecycle. Meet the Authors: Dr. Koontz leads precision molding R&D and production for FISBA in the US. Erick s PhD in Glass Science from Clemson focusing on Chalcogenide glass, provides unique insight in utilization of PGM technologies for infrared applications. erick.koontz@fisba-us.com Wallace Latimer is Sales Director at FISBA with over 25 years experience in optical systems. With a BSOE from University of Arizona, he leverages experience in a wide array of applications and technologies. wallace.latimer@fisba-us.com 5