OPERATING INSTRUCTIONS

Similar documents
Leica RM2235. Rotary Microtome

Leica RM2235. Rotary Microtome

Leica RM2255. Rotary Microtome

Thermo Scientific ROTARY MICROTOME Microm HM 340 E INSTRUCTION MANUAL. Thermo Scientific Rotary Microtome Microm HM 340 E

INSTRUCTIONS FOR ASSEMBLY AND OPERATION OF ERMA MICROTOME

Leica SM2500. Heavy-duty sliding microtome

Top spin Nr /

ANGLE GRINDER STAND USER GUIDE AFTER SALES SUPPORT

Rotary Microtome CUT Operating Manual

Flexproof-Cutter AF-30

TUCANA-02 P PORTABLE END MILLING MACHINE USER S MANUAL

S E L E C T I O N. Arm Curl. User manual

EBA 430 E EBA 430 EP. Operating Instructions

OPERATING INSTRUCTIONS

Sabre Series 2 Inspired Design Precision Engineering

General Machine Instructions

S E L E C T I O N. Upper Back. User manual

FOLDING MACHINE PF-45A OPERATOR MANUAL 1. FUNCTION

Javelin Integra Inspired Design Precision Engineering

12mm (Max) 6mm (Max) 82mm (Max) 12mm (Max) 6mm (Max)

3-1/4 HP VARIABLE SPEED PLUNGE ROUTER

SPIDA SAW OPERATIONS MANUAL

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION

VARIABLE SPEED WOOD LATHE

GMR 1 PROFESSIONAL. ÁU~²Ýœ ÈULM¼« Àπ ß Õ ŸË Õ Èß π Petunjuk-Petunjuk untuk Penggunaan HıÎng dõn s dùng Instructions d emploi. Operating Instructions

Fast End Mill. Drill Re-Sharpening Machine

Knife grinding machine K3 H/K

S E L E C T I O N. Vertical Traction. User manual

TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS. 1.1 Read and Save These Instructions Proper Usage... 02

ATD AMP Variable Speed Reciprocating Saw Owner s Manual

Quick Set Dovetail Jig

Triplematic User manual

KMFS. User Manual. sharpener SHARPENING KIT FOR SYMMETRICAL KNIFE SHARPENING KMFS SHARPEN YOUR KNIVES LIKE A PRO - 1 -

m WARNING: READ ALL m WARNING: This unit can be dangerous! Careless or m DANGER: Risk of cut. Keep hands and feet away IMPORTANT! Safety Instructions

PT 335SCC Multi Operator Manual

User instructions Metallurgical inverted microscope

MANUAL PLASTIC STRAPPING TOOL MODEL P404

STANDARD OPERATION SHEET MICROTOMY

Repair manual. Fifth-wheel coupling JSK 38/50

TABLE OF CONTENTS CHAPTER 1: IMPORTANT SAFETY INSTRUCTIONS

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine.

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

STRINGING MACHINE OWNER'S MANUAL. Copyright 1998 GAMMA Sports - All Rights Reserved

7. Operating instructions: EFL 300

Tube Facing Tool.

Model:CB-MRC. Instruction Manual of Mini Recessed Motorized Screen

Instruction manual. ZCY 2400 Zehntner-Cylindrical mandrel tester

COJSAWBX Electric Jig Saw Assembly & Operating Instructions

GEARED HEAD DRILL / MILL MACHINE INSTRUCTION MANUAL

Vinyl Cutter Instruction Manual

Pro Series. DK4100 and DK5100 INSTRUCTIONAL MANUAL. The Blue Mark of Quality. DK5109

SENA INSTRUCTION MANUAL

OXDALE PRODUCT LTD OPERATING AND MAINTENANCE MANUAL TM400 AND TM400 BIG BASE LOG SPLITTER KEEP FOR FUTURE USE

Capri. I n s t r u c t i o n M a n u a l. Balcony Umbrella x 6.93 Rectangle / SSBU-5X7RT5T

ROTARY HAMMER OWNER'S MANUAL

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

Trautman Carvers. Product Manual

MICRO Shaper MT 300 Manual

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

VARIABLE SPEED WOOD LATHE. Model DB900 INSTRUCTION MANUAL

for authorized workshops

D R I L L - G R I N D E R S BL 13D-2

SERVICE MANUAL FOR HOMELOCK M1034D 2034D 1134DW 1134D

Operating and Maintenance Instructions Keep for future reference

Fifth-wheel coupling JSK 38/50

Product instruction manual Trimming Systems RO3016, RO3018, RO3919, RO3020, RO3021, RO3022, RO3026, RO3027

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y

Introduction to Carpentry Power Tools

BELT/DISC SANDER 25 X 762MM / Ø125MM 250W / 230V

planer/thicknesser 200 x 120mm

SAFETY AND OPERATING MANUAL 700W JIGSAW JM700JS

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

HEDMAN HF-400 OPERATING MANUAL FOLDER. The HEDMAN Company 189 Gordon St. Elk Grove Village, IL Part Number HF REV.

OPERATOR S MANUAL DRILLING MACHINE WITH ELECTROMAGNETIC BASE

ez-lift touch interactive

Instruction manual. ZCO 2410 Conical mandrel tester

256 LS FOLDER OPERATING MANUAL MBM

ENGLISH Spider Stage 1 x 1 m / 2 x 1 m

Cut-True 16M Manual Paper Cutter

8 x 5 PLANER THICKNESSER OPERATING INSTRUCTIONS MODEL: W588

SAFETY AND OPERATING MANUAL. Portable versatile workstation

EasyStitch. Instruction and guarantee manual 1 YEAR GUARANTEE

10 x 6 Planer/Thicknesser

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

BELT/DISC SANDER 25 X 762MM / Ø125MM 250W / 230V

S-85SCH

All Purpose Hardware

Operation Manual ARTICEL 51251

OPERATING INSTRUCTIONS AND PARTS LISTS

1.0 Tool Components and Operation Instructions

EllisSaw.com. EllisSaw.com P.O. Box Verona, WI

SAFETY AND OPERATING MANUAL

MBM Sprint 3000 Booklet Maker

USER MANUAL & PARTS LIST MODEL 40B S/N:

Jigsaw Kit. Operating and Safety Instructions AJA300

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

Eyepieces KHW10X. Diopter Adjustment Ring. Binocular Body Inclined 30. Binocular Clamp Screw. Analyzer control Lever. Reflected Light Illuminator

MODEL 83 Pail Handler

Manual Foot Operated Shear

Motor spindle Operating Instructions. Ref

Transcription:

OPERATING INSTRUCTIONS Rotary Microtome CUT 4062 / CUT 5062 / CUT 6062 CUT 6062 illustrated above INS1000GB 2012-01-06

Instructions CUT4062 / CUT 5062 / CUT 6062 2

CONTENTS 1. INTENDED USE... 4 2. SYMBOLS... 4 3. SAFETY NOTES... 4 4. COMPONENTS... 9 5. SPECIFICATIONS... 10 6. UNPACKING AND INSTALLATION... 12 7. OPERATION OF CUT 4062... 13 8. OPERATION OF CUT 5062... 22 9. OPERATION OF CUT 6062... 27 10. CLEANING AND MAINTENANCE... 33 11. SERVICE... 34 12. OPTIONAL ACCESSORIES... 35 13. WARRANTY... 37 14. DISPOSAL... 37 Instructions CUT4062 / CUT 5062 / CUT 6062 3

1. INTENDED USE The rotary microtome CUT 4062 / CUT 5062 / CUT 6062 is intended for cutting thin sections of soft paraffin-embedded and harder specimens for professional use in routine and research laboratories in the fields of biology, medicine and industry. The system of specimen advance operates very reliable from 0.5 to 100 µm (CUT 5062 and CUT 6062) resp. from 0.5 to 60 µm (CUT 4062). The quality of cutting of this microtome is increased by the automatic retraction during the upstroke of the specimen, which avoids rubbing on the disposable blades or microtome knives. This stops rapid deterioration of the disposable blade or microtome knife. 2. SYMBOLS Dangers, warnings and cautions are marked by this symbol i Special instructions regarding the operation of the instrument are marked by this symbol 3. SAFETY NOTES SLEE rotary microtomes are provided with the following safety features: CUT 4062 CUT 5062 CUT 6062 Hand wheel stop Collapsible hand wheel lever Emergency stop switch Finger protection for knife- or blade-holder The institution which owns the unit and the persons working with the unit, servicing or repairing it have the responsibility for a hazard-free use. Instructions CUT4062 / CUT 5062 / CUT 6062 4

3.1 Hand wheel stop Always use the finger protection with the knife-/blade holder and put hand wheel in stop position Before working with the knife or specimen Before changing the specimen During break time The hand wheel can be stopped in any position. For this purpose move stop towards the centre. Hand wheel stop released. Movement. For releasing the stop please turn the lever towards the outside again. For motorized operation with CUT 6062 please always fold the hand wheel lever to the inside into the recess provided. To do this pull the handle to the outside and then fold it to the inside. Once you move it back again it will automatically latch on again. Hand wheel stop activated. No movement. Instructions CUT4062 / CUT 5062 / CUT 6062 5

3.2 FINGER PROTECTION Use the finger protection always Before you start any work with the knife or specimen Before changing the specimen During work break Finger protection released Finger protection activated Instructions CUT4062 / CUT 5062 / CUT 6062 6

3.3 ELECTRICAL POWER CONNECTION [applicable only to CUT 5062 and CUT 6062] Do not use any extension lead. Make sure that electric power is constant: This should be examined during installation of the unit by a competent person Use a dedicated fuse for the unit Do not connect another unit to the same power circuit Before turning on the instrument, check if the voltage of the mains supply is identical with the name plate of the unit 3.4 EMERGENCY SWITCH [applicable only to CUT 6062] By pressing the red emergency switch an emergency stop is activated. The cutting motor stops immediately. For deactivating the emergency stop it has to be turned, then it moves automatically back into the original position. 3.5 MOTORIZED OPERATION [applicable only to CUT 6062] For switching off the motor please always use the hand or foot switch. Do never simply set the speed to 0. All LED lights on the slider shall be extinguished. Instructions CUT4062 / CUT 5062 / CUT 6062 7

3.6 WORKING WITH KNIVES AND DISPOSABLE BLADES Microtome knives and disposable blades have extremely sharp edges and this can lead to injuries. Please be extremely careful when handling microtome knives and disposable blades. Do not place microtome knives or disposable blades at unsecured areas. Never position microtome knives or disposable blades with the sharp edge pointing upwards. Store blades in a covered container. Use a container that has guides to hold the blades rigid. Never try to catch a falling microtome knife. Always insert the specimen first and then the microtome knife or disposable blade. When applying the brake, ensure that it is tight. Most accidents occur when the brake slips and the operator s hand is drawn into the blade. To avoid compression or knife marks, ensure that the blade is clean. Instructions CUT4062 / CUT 5062 / CUT 6062 8

4. COMPONENTS SLEE rotary microtomes are provided with the following standard components: CUT 4062 CUT 5062 CUT 6062 Basic instrument Manual Semi automatic Fully automatic Object orientation Universal-Cassette-Clamp with orientation alternatively with another clamp as per request, e.g. Standard-Object-Clamp Knife-Holder-Basic-Unit Disposable-Blade-Holder alternatively with another holder as per request e.g. Standard-Knife-Holder Waste tray 1 box disposable blades (50 pcs.) Foot switch for motor drive Operation manual Dust cover 1x Allen key For fixation of object orientation to microtome Mains cable Instructions CUT4062 / CUT 5062 / CUT 6062 9

5. SPECIFICATIONS Operating temperature range +10 C to +40 C Section thickness setting range CUT 4062 0.5 60 µm CUT 5062 / CUT 6062 0.5 100 µm Section thickness selection CUT 4062 0-2 μm in 0.5-μm steps 2-10 μm in 1-μm steps 10-60 μm in 2-μm steps CUT 5062 / CUT 6062 0-2 μm in 0.5-μm steps 2-20 μm in 1-μm steps 20-50 μm in 2-μm steps 50 100 µm in 5-µm steps 100 300 µm in 10-µm steps Trimming thickness CUT 4062 10 μm, 20 μm, 30 μm, 40 μm CUT 5062 / CUT 6062 0 300 µm Specimen feed CUT 4062 28 mm (via coarse feed handwheel) CUT 5062 / CUT 6062 28 mm (step motor) 75 / 150 / 300 / 600 / 3000 µm/s Specimen feed memory CUT 5062 / CUT 6062 2 positions programmable Vertical specimen stroke 60 mm Maximum specimen size 50 x 50 mm Knife holder basis - north-south axis 24 mm Instructions CUT4062 / CUT 5062 / CUT 6062 10

Sectioning speed CUT 6062 20 300 mm/s, selectable via slider Sectioning window CUT 6062 4 sizes selectable Specimen retraction on return stroke CUT 4062 Automatic CUT 5062 / CUT 6062 0-200 µm, selectable Specimen orientation, horizontal 8 Specimen orientation, vertical 8 Specimen orientation, z-axis 360 Section counter CUT 4062 Strokes (optional) CUT 5062 / CUT 6062 Strokes / Distance Dimensions [width x depth x height] Weight without accessories 480 mm x 610 mm x 350 mm incl. handwheel and waste tray CUT 4062 / CUT 5062 33 kg CUT 6062 34 kg Instructions CUT4062 / CUT 5062 / CUT 6062 11

6. UNPACKING AND INSTALLATION 6.1 UNPACKING THE INSTRUMENT Remove the upper wooden cover. Remove the upper supporting foams. Lift the instrument out of the wooden transportation case. For repacking use the original cases. Keep the packing material. Place the instrument onto the selected bench. 6.2 INSTALLATION The unit should be positioned onto a plane, vibration-free surface. Assure convenient and unobstructed access to the hand wheel. Before use remove the transport security underneath the specimen head. For CUT 5062 and CUT 6062 connect the power line of the instrument to the power outlet on the rear. For CUT 6062 the foot switch is connected to the rear socket. Instructions CUT4062 / CUT 5062 / CUT 6062 12

7. OPERATION OF CUT 4062 7.1 INSERTION OF SPECIMEN IN STANDARD OBJECT CLAMP Activate hand wheel lock. Activate finger protection. Loosen object fixation by turning the fixation screw counter clockwise. Insert/Remove object. Tighten object fixation by turning the fixation screw clockwise. Release finger protection and hand wheel lock for cutting. Loosening of object fixation and insertion of new object Fastening of object fixation Instructions CUT4062 / CUT 5062 / CUT 6062 13

7.2 INSERTION OF SPECIMEN IN UNIVERSAL CASSETTE CLAMP Turn hand wheel to its highest position and activate the hand wheel lock. Activate finger protection. Open cassette fixation by turning the fixation lever to the right. Insert/Remove cassette. Tighten object fixation by turning the fixation lever to the left. Release finger protection and hand wheel lock for cutting. Opening of cassette fixation and insertion of new cassette Closing of cassette fixation Instructions CUT4062 / CUT 5062 / CUT 6062 14

7.3 SPECIMEN ORIENTATION ADJUSTMENT Turn hand wheel to its highest position and activate the hand wheel stop. For orientation of the specimen, open the fixing lever on the right side of the orientation. For upward and downward orientation use the upper orientation wheel. For orientation to the left and right use the left orientation wheel. Close the orientation fixing lever. Release hand wheel lock for cutting. Opening of orientation fixation lever and orientation of object holder upwards and downwards Orientation of object holder to the left and right and fixation of orientation Instructions CUT4062 / CUT 5062 / CUT 6062 15

7.4 INSERTION OF KNIFE Activate hand wheel lock. Remove finger protection on the right side of the knife holder. Loosen the knife fixation by turning the two black screws counter clockwise. Insert knife from the right side. Tighten the knife fixation by turning the two black screws clockwise. Loosening of knife fixation and insertion of new knife Adjust knife height by turning the wheels on the left and right side of the knife holder base. Install finger protection on the right side of the knife holder. Release hand wheel lock for cutting. Fixation and height adjustment of knife Instructions CUT4062 / CUT 5062 / CUT 6062 16

7.5 INSERTION AND ORIENTATION OF DISPOSABLE BLADE Activate hand wheel lock. Remove finger protection. Loosen the blade fixation by turning the right lever counter clockwise. Insert blade from one side. Tighten the blade fixation by turning the right lever clockwise. Release hand wheel lock for cutting. Loosening of blade fixation and insertion of new blade. Fixation and height adjustment of blade. Instructions CUT4062 / CUT 5062 / CUT 6062 17

Horizontal orientation For adjustment of cutting area of the blade, loosen the blade holder fixation by turning the right lever on the blade holder base counter clockwise. Set new cutting area by moving the blade holder to the left or to the right. Tighten the blade holder fixation by turning the right lever on the blade holder base clockwise. Release hand wheel lock for cutting. Loosening of blade holder fixation and horizontal orientation of blade holder Cutting Angle For adjusting the cutting angle of the blade, loosen the blade holder fixation by turning the right lever on the blade holder base counter clockwise. Set new angle for cutting by manually tilting the blade holder. A tilt towards the object holder increases the cutting angle (clockwise turn of the knob), a tilt away from the object holder decreases the cutting angle (counter clockwise turn of the knob). Loosening of blade holder fixation and adjusting new cutting angle (increased cutting angle) Tighten the blade holder fixation by turning the right lever on the blade holder base clockwise. Release hand wheel lock for cutting. Fastening of blade holder fixation Instructions CUT4062 / CUT 5062 / CUT 6062 18

7.6 APPROACH TO SPECIMEN Loosen the knife or blade holder base by turning the left lever counter clockwise. Move knife or blade holder base towards specimen. Tighten the knife or blade holder base by turning the left lever clockwise. Loosening of knife or blade holder base fixation and movement towards specimen Fixation of knife holder base Instructions CUT4062 / CUT 5062 / CUT 6062 19

7.7 COARSE ADVANCE [applicable only to CUT 4062] Turn hand wheel on the left-hand side of the instrument to move the specimen towards the knife or blade. At the end positions a sound signal will be heard, do not go further in the same direction. Coarse advance of specimen Instructions CUT4062 / CUT 5062 / CUT 6062 20

7.8 MANUAL CUTTING [applicable only to CUT 4062] Release hand wheel stop. For cutting turn the hand wheel on the right side of the instrument clockwise. A counter clockwise movement of the hand wheel will also result in cutting and incremental advance of the specimen. Optionally set new cutting angle as described in section 7.5 (OPERATION OF CUT 4062). Cutting of specimen For trimming of specimen, select the thickness with the upper knob on the left front side of the instrument (either 10, 20, 30 or 40 µm) and press knob during cutting. Selection of trimming thickness and trimming Select cutting thickness by turning the lower knob on the left front side of the instrument. The selected cutting thickness is displayed above the knob. Selection of cutting thickness Instructions CUT4062 / CUT 5062 / CUT 6062 21

8. OPERATION OF CUT 5062 8.1 INSERTION OF SPECIMEN IN STANDARD OBJECT CLAMP See section 7.1 (OPERATION OF CUT 4062). 8.2 INSERTION OF SPECIMEN IN UNIVERSAL CASSETTE CLAMP See section 7.2 (OPERATION OF CUT 4062). 8.3 SPECIMEN ORIENTATION ADJUSTMENT See section 7.3 (OPERATION OF CUT 4062). 8.4 INSERTION OF KNIFE See section 7.4 (OPERATION OF CUT 4062). 8.5 INSERTION OF DISPOSABLE BLADE See section 7.5 (OPERATION OF CUT 4062). 8.6 APPROACH TO SPECIMEN See section 7.6 (OPERATION OF CUT 4062). Instructions CUT4062 / CUT 5062 / CUT 6062 22

8.7 SPECIMEN FEED MEMORY [applicable only to CUT 5062 and CUT 6062] CUT 5062 and CUT 6062 are equipped with a specimen feed memory that stores two independent positions of the specimen. The LED on the upper right of the control panel will indicate, which memory position is currently active. To select the other memory position press twice quickly. Press once to move to the designated memory position. Press for two seconds to store the current specimen position to the active memory. Specimen feed memory position 1 active. 8.8 MOTORISED COARSE ADVANCE [applicable only to CUT 5062 and CUT 6062] Press Press to move the specimen towards the knife or blade. to move the specimen away from the knife or blade. 8.9 MOTORISED FINE ADVANCE [applicable only to CUT 5062 and CUT 6062] Press to move the specimen slowly towards the knife or blade. Instructions CUT4062 / CUT 5062 / CUT 6062 23

8.10 MANUAL CUTTING Release hand wheel stop. For cutting turn the hand wheel on the right side of the instrument clockwise. A counter clockwise movement of the hand wheel will also result in cutting and incremental advance of the specimen. Optionally set new cutting angle as described in section 7.5 (OPERATION OF CUT 4062). Manual cutting of specimen with CUT 5062 and CUT 6062 For trimming of specimen, select the thickness as described in section 8.10 (THICKNESS ADJUSTMENT FOR TRIMMING). If Trim latching mode is activated, trimming function is activated and deactivated by pressing once. Activation of the trimming function is displayed as illustrated. To activate trim latching mode, continuously press while switching on the instrument. 30 µm TRIM R 5 µ 0000 n Display with activated trimming function 7 µm CUT R 5 µ 0000 n Display with deactivated trimming function If Trim latching mode is deactivated, trimming function is activated by continuously pressing. Activation of trimming function is displayed as illustrated above. Instructions CUT4062 / CUT 5062 / CUT 6062 24

8.11 THICKNESS ADJUSTMENT FOR TRIMMING The display indicates the current setting for the trimming mode (e.g. 30 µm in this example). To change the trimming settings, press continuously and press or to increase or decrease the value. 30 µm TRIM R 5 µ 0000 n i Default setting for trimming thickness is 20 µm. For trimming a thickness range of 10 to 40 µm is recommended. 8.12 THICKNESS ADJUSTMENT OF CUTTING The display indicates the current setting for the cutting thickness (e.g. 7 µm in this example). To change the cutting thickness, press or to increase or decrease the value. 7 µm CUT R 5 µ 0000 n 8.13 ADJUSTMENT OF RETRACTION The display indicates the current setting for the retraction of the specimen upon upward movement (e.g. 5 µm in this example). 7 µm CUT R 5 µ 0000 n To change the retraction setting, press continuously and press once. Keep pressed and change the retraction value by pressing or to increase or decrease the value. i Recommendation and default setting for retraction is 5 µm. Instructions CUT4062 / CUT 5062 / CUT 6062 25

8.14 SECTION COUNTER CUT 5062 and CUT 6062 are equipped with a cutting counter which is displayed on the lower left of the display. The counter either counts strokes or section thickness. 7 µm CUT R 5µ 00015 n To change from counting strokes to cuts or vice versa, simply press once. 7 µm CUT R 5 µ 0105 µm To reset the cutting counter, press for 2 seconds. 7 µm CUT R 5 µ 0000 n Instructions CUT4062 / CUT 5062 / CUT 6062 26

9. OPERATION OF CUT 6062 9.1 CONNECTING THE FOOT SWITCH If a foot switch is to be used with the instrument, insert the plug into the connecting port on the rear of the instrument. Turn the outer ring to fix the plug. 9.2 INSERTION OF SPECIMEN IN STANDARD OBJECT CLAMP See section 7.1 (OPERATION OF CUT 4062). 9.3 INSERTION OF SPECIMEN IN UNIVERSAL CASSETTE CLAMP See section 7.2 (OPERATION OF CUT 4062). 9.4 SPECIMEN ORIENTATION ADJUSTMENT See section 7.3 (OPERATION OF CUT 4062). 9.5 INSERTION OF KNIFE See section 7.4 (OPERATION OF CUT 4062). 9.6 INSERTION OF DISPOSABLE BLADE See section 7.5 (OPERATION OF CUT 4062). 9.7 APPROACH TO SPECIMEN See section 7.6 (OPERATION OF CUT 4062). Instructions CUT4062 / CUT 5062 / CUT 6062 27

9.8 SPECIMEN FEED MEMORY [applicable only to CUT 5062 and CUT 6062] See section 8.7 (OPERATION OF CUT 5062). 9.9 MOTORISED COARSE ADVANCE [applicable only to CUT 5062 and CUT 6062] See section 8.8 (OPERATION OF CUT 5062). 9.10 MOTORISED FINE ADVANCE [applicable only to CUT 5062 and CUT 6062] See section 8.9 (OPERATION OF CUT 5062). 9.11 MANUAL CUTTING See section 8.10 (OPERATION OF CUT 5062). 9.12 THICKNESS ADJUSTMENT FOR TRIMMING See section 8.11 (OPERATION OF CUT 5062). 9.13 THICKNESS ADJUSTMENT FOR CUTTING See section 8.12 (OPERATION OF CUT 5062). 9.14 ADJUSTMENT OF RETRACTION See section 8.13 (OPERATION OF CUT 5062). Instructions CUT4062 / CUT 5062 / CUT 6062 28

9.15 SETTING OF CUTTING SPEED The control of the cutting motor is by means of a slider on the left hand side control panel. LED lights will display the current speed settings. The speed indicated is always the cutting speed (downward stroke), whereas the upward stroke is automatically calculated by the system software. The table below lists the programmable cutting speeds and the related upward speeds. Cutting Speed [mm/s] Upward Speed [mm/s] Cutting Speed [mm/s] Upward Speed [mm/s] 3 50 40 200 5 50 50 250 7 50 70 300 9 50 90 300 11 55 110 300 14 70 140 300 17 85 180 300 20 100 230 300 25 125 300 300 30 150 For setting of vertical motor speeds, press motor. to activate the 7 µm CUT R 5µ 0000 n The display will indicate the cutting mode and the cutting speed. 7 µm CUT R 5 µ 0000 n µm SING 50 mm/s By movement of the finger on the slider, the cutting speed can be increased (upward) or decreased (downward). 7 µm CUT R 5 µ 0000 n SING 70 mm/s Instructions CUT4062 / CUT 5062 / CUT 6062 29

9.16 SETTING OF TRIMMING SPEED The control of the cutting motor is by means of a slider on the left hand side control panel. If the TRIM mode is activated, LED lights will display the current speed settings for this mode. The speed indicated is always the cutting speed (downward stroke), whereas the upward stroke is automatically calculated by the system software. The table in section 9.13 lists the programmable cutting speeds and the related upward speeds. For setting of vertical motor speeds, press motor. to activate the 7 µm CUT R 5µ 0000 n The display will indicate the cutting mode and the cutting speed. 7 µm CUT R 5 µ 0000 n µm SING 50 mm/s Activate the TRIM mode by pressing either continuously or once. The display will show the preset trimming thickness and trimming speed. 30 µm TRIM R 5 µ 0000 n µm SING 50 mm/s If trim latching mode is activated, trimming function is activated and deactivated by pressing once. Activation of the trimming function is displayed as illustrated. To activate trim latching mode, continuously press while switching on the instrument. By movement of the finger on the slider, the trimming speed can be increased (upward) or decreased (downward). 30 µm TRIM R 5 µ 0000 n SING 140 mm/s Instructions CUT4062 / CUT 5062 / CUT 6062 30

9.17 SETTING OF CUTTING MODE For setting of cutting modes, press to activate the motor. 7 µm CUT R 5µ 0000 n The display will indicate the cutting mode and the cutting speed. 7 µm CUT R 5 µ 0000 n µm SING 50 mm/s Press below. to select the different cutting modes as listed 7 µm CUT R 5 µ 0000 n SING 70 mm/s Continuous Mode In this mode, the cutting motor will be activated by pressing and will continuously operate until the user presses again. The specimen head will stop at the upper position when stopped. 7 µm CUT R 5 µ 0000 n CONT 70 mm/s Single Mode In this mode, the cutting motor will be activated by pressing and will perform one cutting stroke. The specimen head will stop at the upper position when stopped. 7 µm CUT R 5 µ 0000 n SING 70 mm/s Instructions CUT4062 / CUT 5062 / CUT 6062 31

Window Mode In this mode, the cutting motor will be activated by pressing or activation of the foot switch and will continuously 7 µm CUT W 2 0000 n WIND 70 mm/s operate until the user presses or activates the foot switch again. In window mode, the system will cut with the selected cutting speed solely in a predefined section of the downward stroke (see list of window sizes below). This enhances the overall speed of the system, especially when cutting with low speed. Window Size W1 W2 W3 W4 Applicable to sample sizes (vertical size) < 10 mm < 20 mm < 30 mm < 40 mm i For sample sizes (vertical size) > 40 mm, please use the continuous mode. Instructions CUT4062 / CUT 5062 / CUT 6062 32

10. CLEANING AND MAINTENANCE 10.1 CLEANING The recommended frequency of cleaning the microtome depends on how frequently the instrument is used. Wear protective clothing and disposable gloves according to Good Laboratory Practices. Please take note of the safety aspects of the instrument. Do not use acetone or xylene for cleaning the unit. Only use alcoholic media. The hood should be cleaned with commercially available plastic cleaner. Do not use alcoholic or organic solvents to clean the hood. Never spray or use cleaning medium directly onto the touch panels. 10.2 RECOMMENDED MAINTENANCE AND SERVICE SCHEDULE Daily Remove section waste from the waste tray after every day of usage. Please use dust cover when instrument is not in use. Weekly Cleaning of blade holder Yearly Complete Service (performed by authorized SLEE service technician) Check of all functions Lubricating of movable parts Check of driving system Complete cleaning Instructions CUT4062 / CUT 5062 / CUT 6062 33

11. SERVICE Internal components should only be serviced by technicians authorized by SLEE. If technical service or spare parts are necessary, please contact your local SLEE medical distributor. Please have the following information available: Complete contact details Type of instrument and serial number Place of instrument and name of user Purpose of service call Delivery date of the unit If it is necessary to return the instrument, it must be cleaned and disinfected before delivery. It must be returned in its original packing. If the instrument or parts thereof are sent back in a dirty or non-disinfected condition, SLEE reserves the right to return the parts to the debit of the customer. Instructions CUT4062 / CUT 5062 / CUT 6062 34

12. Optional accessories CUT 4062 CUT 5062 CUT 6062 Standard Knife Holder #10090008 Disposable Blade Holder (low profile) #10090009 Disposable Blade Holder (high profile) #10090010 Universal-Cassette-Clamp, with orientation #10090004 Disposable blade holder (tungsten carbide blades) #10090014 Universal-Cassette-Clamp, fixed #10090005 Standard Object clamp, with orientation #10090006 Standard Object clamp, fixed #10090007 Super-Mega-Cassette Clamp, fixed #10090021 Foil clamp #10090016 Section counter (CUT 4062) #10090020 Organizer tray #10090022 Instructions CUT4062 / CUT 5062 / CUT 6062 35

CUT4062 CUT5062 CUT6062 Prisma #10090017 Disposable blade (low profile; 50 pcs.) #28407000 Disposable blade (high profile; 50 pcs.) #28408000 Tungsten carbide blades (1 pcs.) #28406000 Microtome knife Profile: A, B, C or D Length: 10 to 40 cm Instructions CUT4062 / CUT 5062 / CUT 6062 36

13. WARRANTY SLEE medical GmbH guarantees that the product delivered has been subjected to a comprehensive quality control procedure, and that the product is faultless and complies with all technical specifications and/or agreed characteristics warranted. SLEE medical GmbH guarantees that the instrument is manufactured under an ISO 9001 quality management system. Unauthorized modification or repair by third party persons will void the warranty. Only original SLEE spare parts must be used. Guarantee claims can be put forward only if the instrument is used according to this manual and for the purpose described. Mistakes and errors which occur because of improper use cannot be accepted. 14. DISPOSAL The instrument or parts of the instrument must be disposed of according to existing local applicable regulations. Instructions CUT4062 / CUT 5062 / CUT 6062 37

SLEE MEDICAL GMBH Carl-Zeiss-Str. 49 55129 Mainz / Germany Tel. +(49) 61 31/9 58 71-0 Fax +(49) 61 31/9 58 71-722 mail@slee.de http://www.slee.de Instructions CUT4062 / CUT 5062 / CUT 6062 38