OPERATOR S MANUAL OSADA EXL-M40 OSADA EXL OSI-2 OSADA, INC.

Similar documents
Surgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E

High Speed Air Turbine Handpiece

STATIS and SANAO. Quality and Precision Handpieces

STATIS and SANAO. Quality and Precision Handpieces

POWER. Rethinking Possibilities, Reshaping Lives

POWER. Rethinking Possibilities, Reshaping Lives

INSTRUCTION MANUAL. 200 Main Street Elmwood WI Phone: Toll Free: Fax:

TABLE OF CONTENTS TABLE OF CONTENTS...1 INTRODUCTION...2 TECHNICAL DATA...3 POLISHER INSTALLATION...4 SAFETY AND OPERATIONAL INFORMATION...

Aesculap Power Systems HiLAN XS

Sales Service Repair. Professional Service Fast Nationwide Shipping

Handpieces for Laboratories. Handpieces for Laboratories. Air Laboratory Handpieces AIR TURBINE HANDPIECE - BUFFALO AIR TURBINE HANDPIECE - BUFFALO

Tube Facing Tool.

MINI PARALLEL REMOVER. Instruction Manual

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DS4012 DOUBLE INSULATION. IMPORTANT: Read Before Using.

GENERAL OPERATIONAL PRECAUTIONS

OPERATOR S MANUAL DRILLING MACHINE WITH ELECTROMAGNETIC BASE

RING CUTTING SYSTEM OPERATION MANUAL. The lighter your touch, the faster GEM cuts

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

Straight and angled handpieces for surgery

Straight and contra-angled handpieces

Electric Screwdriver Operation Manual. (October, 2018) Transformerless Screwdriver VZ SERIES 100V. Lever Start Type Push To Start Type VZ SERIES 120V

SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL

powerful, smart & reliable

Crossfire Footswitch. User Guide

INSTRUCTION MANUAL. 200 Main Street Elmwood WI Phone: Toll Free: Fax:

FBX1104P FBX1104 FBX1106P FBX1106

SFP-550. Operating Manual MATSUHIDAI, MATSUDO-CITY, CHIBA JAPAN TEL: FAX:

Instruction Manual for Recipro Handpiece Model: Z-6X #

ROUND BENDING MACHINE Model: RBM30

Handling instructions

Impact Wrench MODEL TW1000. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.


Primado2 Product Lineup

Top spin Nr /

COMPLEX GRINDER OF MILL& DRILL

SAFETY AND OPERATING MANUAL

RING CUTTING SYSTEM OPERATION MANUAL

Total Performance System THE ESSENCE OF POWER AND VERSATILITY IN A UNIVERSAL SURGICAL SYSTEM NEURO SPINE ENT SPORTS MED PLASTICS GEN.

Impact Wrench MODEL 6905B MODEL 6906

4 INSTALLATION Requirements on Installation Securing Space Before installing the Panaboard, be sure to secure space shown in section 2.6.

Model 204B-EM Elbow Mandrels Rev TABLE OF CONTENTS

FBX-PA-2AC. Third edition : April No

state of mind, state of the art

Drill INSTRUCTION MANUAL. WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE 1 REFERENCE.

DIY KIT DIY KIT. User Manual CTK

Back to health. Back to work. Back to life.

Impact Wrench. 19 mm (3/4 ) MODEL 6906

E.C. HOPKINS LTD PGO4 PEANUT GRINDER OPERATORS MANUAL AND PARTS LIST

Handling instructions

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill MT600 MT601 DOUBLE INSULATION. IMPORTANT: Read Before Using.

SAFETY AND OPERATING MANUAL

MARKING TORQUE SCREWDRIVER MODEL MNTD

VARIABLE SPEED WOOD LATHE

Synea Vision contra-angle and straight handpieces Dental handpieces with ceramic ball bearings (WK-99 / WK-93) and compact glass rod light

USER MANUAL. ReadyFire G6 and IR6 Laser Sight SM25008 SM25009

Electric Chainsaw Sharpener

Lassco Spinnit EBM-S Paper Drill

MAINTENANCE MAINTENANCE

ENGLISH (Original instructions) INSTRUCTION MANUAL. Drill DOUBLE INSULATION. IMPORTANT: Read Before Using.

MF-7524 INSTRUCTION MANUAL

User and Installation Manual. For Tandem Arm and Slim Line Models. Tandem Arm. Slim Line

Premium Soldering station

Cut-Off Machine Model CC 14SE

USER MANUAL. ReadyFire G6 and IR6 Laser Sight SM25008 SM25009

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING CUT-OFF MACHINE

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y

ELECTRIC SLIP ROLL MACHINE. Model: ESR-1300X2.5/ESR-1300X4.5 ESR-1550X3.5/ESR-1580X2.0

Hydrajaws Safety Lifeline Tester

For Tutorials and Troubleshooting visit

KaVo INTRAcompact. KaVo's got the answer.

Instruction Manual HPP-570 HBB-532 HBB-538

Twist Drill Grinder. Operation Manual. Model : GS-20

Handling instructions

Quolis 5000 Light INSTALLATION AND OPERATION INSTRUCTIONS. Model AL-820 IMPORTANT

Twist Drill Grinder. Operation Manual. Model : GS-21 / GS-34

Model SQM-2AC Squaring Module Rev TABLE OF CONTENTS

MUTO COMFORT XL 150 L 80

southpaw enterprises, inc.

10" Wet Tile Cutting Saw

AutoSeal FD 2002/FD 2032 FE 2002/FE 2032 OPERATOR MANUAL FIRST EDITION

END MILL RE-SHARPENER EMG-413

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

Contents. I'DANGER - To reduce the risk of "SAVE THESE INSTRUCTIONS" This knitting machine is for home use. IIIMPORTANT SAFETY INSTRUCTIONS"

Instruction Manual and Safety Instructions

The object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver.

VARIABLE SPEED WOOD LATHE. Model DB900 INSTRUCTION MANUAL

Elcometer Muller Laboratory Grinder

K&M Precision Shooting Products Benchtop Case Preparation Machine User Guide

TB & SB Series Drill Presses

Standard PS-P61 Punch Stapler

ROTARY HAMMER OWNER'S MANUAL

User Manual. LED Dental Scaler, Drill and Polishing unit Eicksonic Plus

MEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET. for Intramedullary Nail System

Magnetic Base Drilling Machine A100/32. Operators Instruction Manual And Spare Parts Listings

GENERAL OPERATIONAL PRECAUTIONS

Shaver Handpieces. User Guide , -501 Formula Shaver Handpiece , -501 Formula Hand-Controlled Shaver Handpiece

SALES CUSTOMER SERVICE TECHNICAL ASSISTANCE CALL TOLL-FREE:

Handling instructions

High Speed Drill MODEL WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Transcription:

OPERATOR S MANUAL OSADA EXL-M40 OSADA EXL OSI-2 NEW Electric BRUSHLESS Laboratory MICROMOTOR Handpiece System SYSTEM FOR ORAL with SURGERY BRUSHLESS AND IMPLANT MICROMOTOR PREPARATIONS OSADA, INC. 30008436 So. West Robertson Third Street, Blvd., Suite Suite 695 130 Los Los Angeles, CA 90048 90034 (800) 426-7232, (323) (310) 651-0711 841-2220, FAX (310) (323) 841-2221 651-4691 www.osadausa.com

13 TROUBLE SHOOTING WHEN YOU FIND THE UNIT WORKING ABNORMALLY, PLEASE CALL OSADA, INC. IN LOS ANGELES TOLL FREE TELEPHONE NO. 1-800-426-7232. IF ABNORMAL BUR ROTATION OCCURS, THE BLUE BEAM WILL PULSATE RAPIDLY AND CIRCUIT BREAKER MAY CEASE THE ROTATION. CHECK THE UNIT AND REMEDY OBVIOUS PROBLEMS. OTHERWISE CALL OSADA, INC. IF ABNORMAL PERFORMANCE WITH THE FOOT PEDAL ATTACHED TO THE POWER CONSOLE OCCURS, THE FOOT PEDAL MAY NEED SENSOR ADJUSTMENTS. WARNING & PRECAUTIONS OSADA EXL-OSI-2 BRUSHLESS MICROMOTOR SYSTEM is a deceivingly quiet but powerful drill unit designed for Oral Surgery and Implant Preparations. It provides a wide range of power and high torque. Take a test run before each surgical procedure, and make sure the instruments are in good working condition including attachments. Dull or bent attachments can cause unnecessary risk of injury or damage to the instrument. In Oral Surgery set a speed range comfortable to operate. Avoid extremely fast rotation with double speed handpieces. Avoid long continuous running; give a short rest time in between. Adjust the pressure while cutting to achieve the best results. MAKE SURE THE HANDPIECE IS FREE FROM BINDING, NOISE, OR HEATING UP. IF YOU HAVE ANY DOUBT, DO NOT USE THIS HANDPIECE. THE MAINTENANCE OF THE EQUIPMENT IS OF UTMOST IMPORTANCE.

12 MAINTENANCE Wipe the Power Console and non-autoclavable parts with a damp towel to keep clean. Damp cloth with alcohol can be used to wipe clean and sanitize the external surfaces of the Power Console, Foot Switch, Cords, Hanging Rod, etc.. Avoid harsh chemical solutions such as germicides to sanitize the surfaces. Do not spray liquid cleanser, it may cause rust and damage external and internal components. MAINTENANCE of AUTOCLAVABLE PARTS M ICROMOTOR SM1-3 AND ITS MOTORCORD, AND OSADA S SURGICAL HANDPIECES ARE ALL STEAM AUTOCLAVABLE. IRRIGATION PARTS INCLUDING THE TUBING AROUND THE PUMP CASSETTE ARE ALL STEAM AUTOCLAVABLE. After surgery, wipe clean external surfaces of the micromotor, cord, handpieces, etc. A damp cloth with alcohol (Ethanol) can be used to clean. Now the MICROMOTOR/MOTORCORD are ready to be autoclaved. The HANDPIECES must be treated with Osada s spray oil prior to autoclaving. Removable nose guards of the handpieces can be separately washed. Spray oil handpieces to purge debris from inside until clean oil comes out of the nose end. Keep the handpieces up-side-down for a while for better penetration of the oil throughout. Put the instruments in an envelope or wrapped in gauge, and place in an autoclave. Avoid direct contact with the autoclave walls. Recommended Sterilization Methods: (1) Steam Autoclave (Follow the manufacturer s direction.) Sample A. 135 C (=275 F) max. 3 min. or longer Sample B. 132 C (=270 F) 5 min. or longer Sample C. 121 C (=250 F) 20 min. or longer Followed by 15-30 min. drying cycle Use a protective envelope or wrapped in gauze. (2) Gas Chamber with Ethylene Oxide (3) Ethanol (Alcohol) can be used to dampen the cloth and wipe external debris and sanitize. Do not leave the soiled parts unattended. Do not let it solidify. Keep this instrument clean and dry. IMPORTANT MESSAGE Read this manual thoroughly before using any part of the OSADA EXL OSI-2. ALL-IN-ONE, SIDE BY SIDE 2 MOTOR SYSTEM WITH PERISTALTIC IRRIGATION PUMPS. INTRODUCTION (FEATURES) The integrated unit consists of a sturdy table top Osada EXL Series Brushless Micromotor System with built in peristaltic irrigation system. Side-by-Side 2 motor system specifically designed for the Oral Surgery and Implant Preparations. The micromotor SM1-03 and SMC2 motor cord are steam autoclavable along with the accompanied silicone tubing and irrigation bottle (optional). Comes with junction to accept ISO e-coupler handpieces. Solid state transistorized feedback circuitry maintains speed and high torque under varying load, producing highly efficient performance. High Torque / Low Speed operation for Implant preparations with adjustable speed and torque settings. Smooth running Oral Surgery up to 80,000 RPM with double speed handpieces. FOR MORE INFORMATION, TECHNICAL ASSISTANCE AND SERVICES, CONTACT OSADA, INC. 3000 S. Robertson Blvd., Suite 130 Los Angeles, CA 90034 (800) 426-7232, (310) 841-2220, FAX (310) 841-2221 www.osadausa.com Manufactured by OSADA ELECTRIC CO., LTD. 17-5 Nishigotanda 5-Chome Shinagawa-ku, Tokyo 141-8517, JAPAN Phone: 813-3492-7651 FAX: 813-3779-0976 1

2 11 COMPONENTS Model OSADA EXL OSI-2 A: Control Console Model EXL OSI-2 B: Foot Control with Cord C: SM1-3 brushless micromotor with e-coupler junction D: Peristaltic Irrigation Pump Head and tubing set WIRE DIAGRAM EXL OSI-2 BRUSHLESS MICROMOTOR SYSTEM FOR ORAL SURGERY AND IMPLANT PREPARATIONS B: FOOT CONTROL With cord A: CONTROL CONSOLE MODEL EXL OSI-2 C. SM1-3 Brushless Micromotor with SMC2 Motorcord (autoclavable) FRONT IRRIGATION PANEL XL-S40 PUMP HEAD Power Cord HHA Autoclavable Handpiece Holder Pump Head Cassette & Tubing POWER CORD Outlet Holder blocks Supply

OSADA EXL OSI-2 nomencrature 10 IRRIGATION ACCESSORIES EXL OSI-2 with Peristaltic Irrigation Dispenser (#) marked parts are steam autoclavable Part ID Description HANGING ROD FOR SALINE BAG Price EXL OSI-2 PUMP Built in Peristaltic Pump (the Power Console) #EXL OSI-PHT Pump Head Tubing (Bold) with connectors N/A $30.00 #EXL OSI #EXL-OSI-15A #ID-15BC #F15-15D Handpiece Tubing Packet 10-ft. Silicone Tubing with a male joint Handpiece-end Tubing & reducing Joint (ø1.02mm) Tubing Clamps (set of 8) $45.00 $30.00 $ 5.00 $10.00 #F15 #ID-22B #ID-22C #ID-22D Reservoir Set Connecting Tubing to Pump w/2 male joints 500 cc Reservoir Bottle (no cap) Reservoir Bottle Cap Assembly $41.00 $10.00 $11.00 $20.00 #F15 #ID-25RL #ID-25N #ID-25E Hanging Rod Set (w/set of 2 Spare Needles) Long Hanging Rod Bag Adapter Needle (disposable) / each Connecting Tubing to Pump w/male joint $85.00 $45.00 $10.00 $10.00 Optional Accessories: #ID-11 500 cc Reservoir w/plain Cap #Miscellaneous Joints (specify as part of above parts) price / each $16.00 $ 1.00 A: CONTROL CONSOLE MODEL EXL OSI-2 B: FOOT CONTROL With cord Brushless Micromotor SM1-3 and Motor Cord SMC2 CSR20 20:1 Contra Angle Handpiece for Implant Procedure Pump Head Cassette Pump Head Cassette Tubing 33 Optional: WIRE DRIVER WG5 with Jacob Chuck Handpiece and Motor Cord SMC2 HOW TO INSTALL THE TUBING TO THE PUMP HEAD CASSETTE EXL OSP-2 has a pump head cassette on each side. Irrigation is directed from the back near the irrigation bag or a bottle toward front on each side to be connected to the handpiece tubing. Position of the pump head cassette F15 15D Tubing Clamps (6)

4 PARTS EXL OSI-2 SPECIFICATIONS ITEM 1. Classification for form of protection JIS T0601 Class I against electric shock 2. Classification for level of protection JIS T0601 Type BF connection against electric shock Power Voltage AC 120V 3. Power Source Power Frequency 50/60 Hz Power Input 0.34A Dimension (main body) Weight Irrigation Pump 210 (W) x 300(D) x 160(H) mm 7.9 kgs 1. Activated with Foot Control 2. Ajustable Volume 20-100 ml/min 3. Peristaltic cassette on each side of the PC 4. Autoclavable tubing outside of the PC 1. Memory items: 4. Power Console Box Memory Maximum speed, Torque, Irrigation Volume (detachable power and Handpiece speed ratio 1:1 or 1:2 cord; 2.5 meters) 2. Foot Control select Memory (1-4) 1. Rotational Speed selection switch Brushless Micromotor 1000±100-40,000±1000 rpm on the back panel Micromotor SCM1-03 2. Adjustable Maximum speed 30,000 or 40,000 rpm 3. Motor 1 or 2 by selection Alarm Alarm sounds on reverse rotation Torque (maximum 50 Ncm) Operation Mode Micromotor stops at the set torque when loaded Display torque on Motor 1 Implant Preparations Motor 1 for Implant Preparations Motor 2 for Oral Surgery or Wire Driver 5. Foot Controller Dimension (main body) 206 (W) x 186 (D) x 38.4 (H) mm with 4 meter cord Weight 2 kgs. Left Button Micromotor 1 or Micromotor Switching Right Button Functions Choice of Mode 1 through 4 Left Pedal Right Pedal Dimension (main body) Activate Reverse Rotation Activate Forward Rotation Diameter 25mm, Length 72.3mm 6. Surgery Micromotor Weight 100g Autoclavable at 135 C SCM1-03 brushless Rotational speed 1000±100-40,000±1000 rpm steam autoclavable Stopping torque 5 Ncm Usable Handpieces Handpieces with ISO type jooint (e-coupler) 7. SMC2 Motor Cord SMC-2 Diameter 6mm, Length 3m Autoclavable at 135 C HOW TO CONNECT A HANDPIECE TO THE MICROMOTOR SM 1-3 THE HANDPIECE AND THE MICROMOTOR CONNECTION IS SIMP- LY ACHIEVED BY PUSH AND PULL ACTIONS. モータ側溝 GROOVE A Spring loaded pin on the micromotor is marked with a dot. The handpieces without light will engage when the pin of the micromotor slips into the hole at the base of the handpieces for a full engagement. (Align the dot on the handpiece with the dot on the micromotor. A PROTRUSION ハンドピース側の突起 INSERT THE HANDPIECE ON TO THE E-JUNCTION OF THE MICRO- MOTOR AND PUSH TOGATHER. TWIST A LITTLE UNTIL YOU HEAR A CLICK AND THE FULL ENGAGEMENT IS FELT. THE HANDPIECE CSR20 HAS A PROTRUSION AT THE END AND THIS WILL MATCH THE GROOVE ON THE MICROMOTOR TO EN- GAGE. モータ側ピン マーク PIN RED DOT The micromotor SM1-3 and the motorcord are steam autoclavable. Wipe off any visible debris with tightly squeezed towel dampened with water or ETHANOL (ALCOHOL) before placing it in the autoclave. DO NOT SPRAY GERMICIDE SOLUTION around the instruments! Handpieces are all steam autoclavable. However, proper preparation is important to maintain the well working handpieces: immediately after a procedure, spray oil with Osada spray oil from the back end of the handpiece to purge debris inside until clear oil comes out of the bur end; keep the handpiece upside down to allow oil to penetrate throughout and drain excess oil; place it in a bag for autoclaving. 9

8 SETTING UP Model OSADA EXL OSI-2 Micromotor 2 accepts WIRE DRIVER MICROMOTOR with Interchangeable Chucks BRUSHLESS MICROMOTOR SM-1-3 AND SMC2 (600 40,000 RPM) COMPONENTS dimensions EXL OSI-2 power console 5 ISO JUNCTION ACCEPTS VARIATY OF E-COUPLER HANDPIECES BRUSHLESS MICROMOTOR SM-1-3 Environmental condition for storage Ambient Temperature -10-60 Relative humidity 10-90% Atmospheric Pressure 500-1,060hPa CSR20 20:1 CONTRA-ANGLE HANDPIECE SH26SP 1:1 HANDPIECE SH42SP 1:2 DOUBLE SPEED HANDPIECE SH31SP 1:2 DOUBLE SPEED HANDPIECE SSH01 SAGITTAL SAW HANDPIECE SAMPLE HANDPIECES

6 7 FRONT PANEL DISPLAY Showing : Motor 1, Memory 1 (for implant drilling) Max Speed: 2000 min-¹ Torque (with CSR20 20:1 contra angle): 15Ncm Irrigation: 40 ml/min FRONT PANEL BUTTONS 1) Motor Button: Select a Micromotor 1 or 2 2) Memory Button: Check and edit the Memory 1 through 5 as you like; matching the selected handpiece. Speed, Torque and Irrigation volume can be adjusted by using UP or DOWN triangle. BACK PANEL FOOT CONTROL 1) Left Button: Select Micromotor 1 or 2 2) Right Button: Select the Memory matching the handpiece you selected. ACTIVATION BY FOOT CONTROL Motor button Memory button System Maximum Speed Set Switch 30,000 RPM / 40,000 RPM Electric cord Main switch Foot Control Cord Connector to the Receptacle RIGHT PEDAL: Forward Rotation LEFT PEDAL: Reverse Rotation (lights the LED, warning the reverse operation)