Overview Special Lugs for Special Problems Angled, Shaped and Trimmed the Way You Need Them

Similar documents
Overview The Thomas & Betts Method is Better. Just Four Easy Steps to a Perfect Connection! Step 1. Step 2

Color-Keyed. Compression Connector System. Table of Contents

Connection by Compression

Connection by Compression

Copper Compression Lugs Conductor Size #8

E-Z-Ground Grounding Connectors

Copper Compression Lugs Conductor Size #8

3M Scotchlok Copper/ Aluminum Compression Lugs, Series

Chamfered/Funneled Terminal Barrel Entry

COPALUM Terminals and Splices (For Solid & Stranded Aluminum or Copper Wire)

The Spec-Kon. Example: KV18-6R-M (18) AWG (14) AWG (10) AWG (8) 8 AWG (6) 6 AWG (4) 4 AWG (2) 2 AWG

AMPOWER Terminals and Splices Catalog Revised 05-95

Ground Clamps Cable Tray

INTERMEDIATE METAL CONDUIT

GROUNDING EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA EA

Connector, Tool and Die Chart

File E13288 Vol. 1 Sec. 24 Page 1 Issued: Vol. 22 Sec. 2 Revised: and Report

FLEXIBLE POWER & GROUNDING. Braid Solutions

C SERIES MINIATURE, REGULATED HIGH VOLTAGE DC TO DC CONVERTERS

SECTION - 3 EARTHING CLAMPS & FITTINGS

SB 50 Connectors - up to 120 amps

Power Distribution Blocks with Short-Circuit Current Ratings

Kerkau Manufacturing. B16.5 Flange Book

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

1.05 Y1MR (1) W5CRT (1) W5CRT (1) U5CRT (1) #6 AWG YA6CL6-BOX MY29-3 (1) X5CRT (1) X5CRT (1) UBCABT (1)

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Connecting the Grid. Copper Substation

U36RT (4) 600 kcmil 300 YA362TC U32ART (4) Green /4 YA362TC / YA362TC

Installation Tooling System Taps Thin-Wall C-taps Run=Tap, AWG only W28VT PURPLE 15 U997 ORANGE 997 U654 PURPLE 654

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

Warehouse Stock Transformers

Success Depends on the Crimp

MANUFACTURERS & EXPORTERS OF COPPER BRAIDS & COPPER LAMINATED CONNECTORS

LGH High Voltage Connectors

Plastibeton Trench System. Installation Packet

sealed mini usb connectors

W30VT (2) U30RT (2) 300 kcmil 150

JCN cables. The. splice is an

TABLE OF CONTENTS BURNDY. Substation Bolted. COPPER SUBSTATION Introduction L-3 L-17. Type UH Tube L-17 L-4. Type NAS Cable to Pad

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

Manual Crimp Tool T&B Catalog Number: TBM4S UPC Number: Status:

Installation Manual. Arc Chamber

Powerpole Connectors - PP75: up to 120 Amps

Collection of standards in electronic format (PDF) 1. Copyright

SBS Connectors - up to 110 amps

Tri-Rated Flexible PVC Equipment Wire

STANDARD RTD's INDEX

Powerpole Connectors - PP75: up to 120 Amps

Mechanical Grounding Connectors

SECTION. 1. Terminals for Wire Sizes 26 to 10 AWG Splices and Connectors for Wire Sizes 26 to 8 AWG...18

Medium-base Lampholders

F-3200 SERIES Inline Electromagnetic Flow Meter Wiring Instructions

SBS Connectors - up to 110 amps

RACO Commercial Fittings

Powerpole Connectors - PP75: up to 120 Amps

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

Burndy Die Designation Die Code Cat. No.

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Plastibeton Trench System. Installation Packet

Double thick tongue. Tongue Wire Stud Hole CT-930, CT-930CH, S4-10R-E

BURNDY EC&M TYPE YGA HYLUG Terminals. TYPE YGHA HYLUG Terminals. TYPE YGIB GROUNDLINK Connector. TYPE YGHS HYLINK Ground Splice

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

Beam and Purlin Clamps Beam Clamps

TURCK Industrial Connectivity Products

RACO Commercial Fittings

MANUFACTURERS & EXPORTERS OF COPPER BRAIDS & LAMINATED CONNECTORS

ENVIRONMENTAL. Operating Temperature: -40ºC to +130ºC. Wire Size. Code Accepted Max Wire Gauge Insulation AWG Solid or Stranded

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

COYOTE Terminal Closure (Single Chamber) Hermetically Sealed With Hardened Adapters

General Information...SA1-SA4

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Wood Deck Anchor. Instructions READ CAREFULLY Garrymore Ln Missoula, MT

Standard Terminals and Splices

ARCHITECTURAL HARDWARE

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

DeviceNet Series. Cables Cordset Accessories Receptacles Receptacle Accessories Junction Blocks

ELCON* Drawer Series Connectors

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Adhesive Air Terminal Bases. Universal Surface Bases. Offset Parapet Air Terminal Bases. Section 3.2. Air Terminals & Air Terminal Bases

AMPLIMITE Cable Connectors and Shielding Hardware Kits

S INGLE CIRCU I T 120V. LABELING: cul listed. GES Track Components. Flex Connector GES 23 GES 17. Dead Ends GES 41. (use with any connector)

Poke-Home: Horizontal AWG: WTB INTER CONNECT APPLICATIONS FEATURES AND BENEFITS ELECTRICAL MECHANICAL ENVIRONMENTAL HOW TO ORDER 00X

C SERIES MINIATURE, REGULATED HIGH VOLTAGE DC TO DC CONVERTERS

Engineering Data Rail Lifters

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Compression Connections BURNDY 12-TON U DIES* W DIES. BURNDY Die Sets

CALL (512 ) x6400

PF/PFQ. High Amperage plug and receptacle. Main Advantages

Mod e l A urora P l u s Walk-In Doo r

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

BLACKBURN GROUNDING SYSTEMS

Thru Wall Floor Seals For New Installation

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Transcription:

Special Lugs for Special Problems Angled, Shaped and Trimmed the Way You Need Them Thomas & Betts can solve your difficult wire bending and terminating problems in confined power distribution panels, switchgear and motor control enclosures. We have the design and production capability to deliver exactly the type lug you need, shaped the way you need. Straight,, 0, 4, 60 and 90 angle Stacking or non-stacking Narrow tongue or standard Tin, silver, lead, nickel Thomas & Betts offers an extensive line of copper Blackburn lugs featuring the Color-Keyed system for #8 AWG through 000 flex and code cables. The lug tongues are modified in several different configurations to meet your exact needs: 4 and 90 bend angles, narrow tongues to fit into circuit breakers, offset tongues to stack two cables and special stud hole drilling. These special configurations let you: 2 Run cable directly to the bus bar with no bending. Terminate into very narrow spaces. Utilize minimal bus bar space. The specially designed lugs help you clean up your cabling in crowded enclosures. The photographs show some examples of how and where the lugs can be used. Customized Connectors for Copper Cables Standard and special tongue angles, stacking and nonstacking, bolt holes sizes and centers, protective platings. Specially modified one- and two-hole copper compression lugs, Series 400, 4200, 480BE and 490BE for flex and code copper stranded cables. Material: Highconductivity wrought copper. Minimum order quantity: Standard package quantity by cable size. Consult factory for price and delivery. All customized lugs are made to order. A.R.O. Non-cancelable. F-6 Tel: 90.22.8000 800.86.809 Fax: 90.22.4 Tel: 888.862.289

Order Form Catalog No. (For 400, 4200, 4800 & 4900 Series Copper Lugs Only) Design Controls and Requirements Qty. All MADE-UP catalog numbers start with a standard or basic catalog number and are followed by the customer-required extra features: tongue shape, bolt hole size, distance between bolt holes, stacking, plating and inspection hole (peep hole). A code letter or a number has been assigned to each extra feature. See CODE TABLE. Notes: ) Lack of any of the extra features on the MADE-UP catalog number means that the standard Cat. No. features are prevalent. 2) If either bolt hole size or distance between bolt holes needs to be changed from standard Cat. No., both code numbers will appear on the MADE-UP Cat. No. (See example below) Code Table Tongue Shape 422 2-hole 4/0 AWG copper lug basic cat. no. Bolt s UB 90 tongue CAT. NO. 422 UB 04 6 B SP Bolt Centers 04 " bolt hole Stacking 6 " hole spacing Finish (Plating) B bottom stack Inspection (Long Barrel) SP silver plating Inspection (Short Barrel) Type Code Size.020 Code Distance.0 Code Type Code Type Code I.D. Code I.D. Code UI #8. 02 2" 08 Top T** Silver Plate SP Peep PH Blind End BE 0 UT #0.204 0 8" 0 Bottom B Lead Plate LP 4 UF ".28 04 " 2 Nickel Plate NP 60 US 6".44 0 8" 4 Plain Finish PF 90 UB 8".406 06 " 6 No Marking NM Blank BT 2". 08 8" 8 Not QTP if (No Bolt ) 8".66 0 " 20 suffix other ".82 2 8" 22 than - PF or 8".9 4 2" 24 standard ".062 6 8" 26 tin plate " 28 8"* 0 2"* 2 * These bolt centers not available for bolt holes larger than 6". ** Not required for 4 & 90 top stacking. Cable Code Weld #8 #6 #4 #2 # /0 2/0 /0 4/0 20 & up (Code Only) Tongue Tongue Thickness Tongue Length For Blank Tongue For Blank Tongue Barrel Barrel Length Length Plus Plus Transition Transition Barrel O.D. Long or Short Tongue Width Offset Offset Bolt/Stud Size Size Peep Peep Yes No Barrel I.D. Bolt Bolt Spacing Wrench Wrench Clearance If If required Tel: 90.22.8000 800.86.809 Fax: 90.22.4 Tel: 888.862.289 F-

Tongue Specifications See Chart A For Dimensions Stud Sizes #8 #0 " 6" 8" 2" 8" " 8" " Chart A Nominal Bolt Size.0 Offset.00 Wrench Clearance Min. Single Double Blank #8 Code #8 Weld #6 Code #6 Weld #4 Code #2 Code #4 Weld Tongue Width Cable Size # Code #2 Weld /0 Code # Weld 2/0 Code /0 Weld /0 Code 2/0 Weld 4/0 Code /0 Weld #8..200.240.406.4.62.9.62.0.82.9.00.2 #0.204.28.20.406.4.62.9.62.0.82.9.00.2.28.20.2.469.00.62.9.62.0.82.9.00.2 6.44..406.62.62.62.6.62.0.82.9.00.2 8.406..440.8.8.94.6.62.0.82.9.00.2 2..00.62.0.0.0.82.9.00.2 8.66.62.8.9.00.2.82.0.0 8*.9.8.890 *.062.9.000 * These bolt holes available in one-hole lug only. Chart B Cable Size Tongue Thickness Straight Lug Barrel Length Plus Transition Barrel 20 Code Dim Stacked Lugs Dim Y Dim H Short Long O.D. I.D. Straight 4 90 Short Long Short Long #8.080.6.9.260.80.8.48.94.9.808.9.09 #6.08.6.9.296.2.4.44.42.8.99.6.06 #4.099.68.98.6.266..622.02.6.849.88.8 #2.08.8..40.02.26.649...92.98.28 #.06.82.2.46.6.22..92.0.028.96.406 /0.2.9.2.20.96.20.89.646.94.042.0.42 2/0.2.96...446.20.89.696.829.0.2.4 /0.2.08.4.62.0.20.946..900.48.22. 4/0..2.0.0.64.24.0.826.0..8.8 20...92.66.629.24.2.89.08.44.48 2.0 00..900 2.6.80.660.49.226.9.80.26.924 2.69 0. 2.090 2.896.926.20...0.26.80 2.096 2.896 400. 2.460 2.980.960..9.0.08..9 2.484 2.984 00.28 2.60.60.00.82.64.4.22.629 2.266 2.669.69 600.244 2.900.490.200.926.2.60.2.62 2.4 2.89.49 00.228 2.84.2.99.684.662..80.0 0.20.00.92.0.00.80.4.4.82 2.44.00.92 800.266.2..09.800.28.62.92 2.8.2 4.4 900..40 4.0.00.4.940.900.60 2.06.8,000.29.6 4.00.0.20.890 2.00.6 2.0 2.8.48 4.06 Note: Stacking lugs are available for one bolt only. Consult Factory: Straight: 00 & up. 4 : 400 & up 90 : 00 & up F-8 Tel: 90.22.8000 800.86.809 Fax: 90.22.4 Tel: 888.862.289

.2 TYP Chart C T-Top B-Bottom Bolt Size Straight Stack 4 Stack 90 Stack 4 90 Formula Formula = (.2 + 2 (OD) +.0 Tongue Thickness) 00 4/0 Weld 0 400 Y 00 400 Weld Tongue Width.00 Code Cable Size 600 00 Weld 2/24 #8 #0.20..40.60.4.80.840.9 2.00 2.80 2.26 6.20..40.60.4.80.840.9 2.00 2.80 2.26 8.20..40.60.4.80.840.9 2.00 2.80 2.26 2.20..40.60.4.80.840.9 2.00 2.80 2.26 8.20..40.60.4.80.840.9 2.00 2.80 2.26.20..40.60.4.80.840.9 2.00 2.80 2.26 8*.60.4.80.840.9 2.00 2.80 2.26 *.4.80.840.9 2.00 2.80 2.26 * These bolt holes available in one-hole lug only. H 00 0 800 900 000 Tel: 90.22.8000 800.86.809 Fax: 90.22.4 Tel: 888.862.289 F-9

Compression Connectors for Copper Conductor Two- Lugs Long Barrel 600V to kv Material: High-Conductivity Wrought Copper Finish: Electro Tin Plate Peep s Available! Add suffix -PH Wire Size Dimensions (in.) Cat. No. Code Flex CLASS G, H, I, K, M Bolt Size A B C D E F H Die Code 480BE.86.9.0.0.20 8 26-426- #0 2.00.2..0.20 8 ERG4002, 26-426-SPH #4 0 AWG #0 2.00.2..0.20 2 8 ERG400 26-069-298.89.22.0.0.20 8 26-069-0.98..0.0.20 8 480BE* /24 = 4.9 2.9.89.42.0.26 8 2 48BE* #8 AWG #8 Weld 2..29.4.06.26 2 26-069- 2 Navy 8.00 2.0.6.06.26 8 2 482BE* 2.28.28.44.08.0 8 24 0 Navy 26-069-04 2.6.6.4.08.0 24 6/24 = 24.6 26-069-22* #6 AWG 2.4.4.4.08.0 24 #6 Weld 26-069-8* 8 2.9.9.9.06.0 8 24 # Weld 26-069-868* 2 4.8.00.88..0 2 24 484BE* 2..9.2.0. 8 29 26-069-246* 2...6.09. 29 40 0 Navy 26-069-0 2.88.88.8.09. 8 29 #4 AWG #, 9/24 = 6. 26-069- 6 2...6.0. 2 29 #4 Weld 26-069-9* 8..98.9.09. 8 29 26-069-* 2 4.8.00.88.09. 2 29 26-069-06.06.88.6.09.4 8 48BE* 2.4.28.9..4 8 26-069-00* 2.6..68..4 60 Navy 486BE* 6 2.8.6.9..4 8 #2 AWG # Weld 480BE 8.80 2..9..4 8 2/24 = 0.4 26-069-60* 8.08.94.9..4 8 26-069-869 2 4.02 2.88..09.4 8 48BE* 2 4.28.00.88..4 2 4809BE 2.88.9.6..4 8 Navy 482BE 2..40.6..4 0/24 = 60. 488BE # AWG 6 2.9.6.6..4 8 8 /24 = 0.6, 26-069-6 8.0.98.6..4 8 #2 Weld 48BE 2 4.4.00.88..4 2 26-069-08.6.88...2 8 42 26-069-08P.6.88...2 8 42 489BE 2.6.9...2 8 42 00 Navy 48BE 2..8...2 42 /0 AWG # Weld 4860BE 6 2.9.6...2 8 8 42 22/24 = 90.8 26-069-62P 8.2.98...2 8 42 26-069-62 8.2.9...2 8 42 26-069-9* 2 4..00...2 8 42 Contact for specific stranding listings * UL Listed for direct-burial applications E H A B F C D Die Color C NEST RED BLUE GRAY BROWN GREEN PINK Tooling: pp. F-80 F-00 Die Selector Chart: pp. F-0 F-04 F-28 Tel: 90.22.8000 800.86.809 Fax: 90.22.4 Tel: 888.862.289