Certificate of Analysis First issued: July 2000 Version: December 2007 MA-2c

Similar documents
CERTIFICATE OF ANALYSIS

CERTIFICATE SD SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

bvparm2006.cif bvparm2006.cif Printed by Ram Seshadri

S1 TITAN Alloy LE Calibrations (P/N: )

First Pass Sampling on Vranje-South Project Defines Li-B Anomalies

Polymer Comparisons for the Storage and Trace Metal Analysis of Ultrapure Water with the Agilent 7500cs ICP-MS Application

AMIS0302. Certified Reference Material. Certificate of Analysis

Certified Reference Material

Stop Worrying About Interferences With These ICP-OES Solutions

AMIS0111. Certified Reference Material. Certificate of Analysis

CRMs

sp1 sp2 sp3 sp4 sp5 TAP LPET LPET TAP LLIF Na Kα (albite) Ca Kα (anorthite) K Kα (orthoclase) Mg Kα (forsterite) Mn Kα (rhodonite)

AMIS0180. Certified Reference Material. Certificate of Analysis

AMIS0179. Certified Reference Material. Certificate of Analysis

AMIS0213. Certified Reference Material. Gold ore, greenstone, North Mara Gold Mine, Tanzania. Certificate of Analysis

DTU DANCHIP an open access micro/nanofabrication facility bridging academic research and small scale production


Supplement of Vertical and horizontal variability of PM 10 source contributions in Barcelona during SAPUSS

AMIS0409. Certified Reference Material. Certificate of Analysis

AMIS0214. Certified Reference Material. Gold ore, greenstone, North Mara Gold Mine, Tanzania. Certificate of Analysis

Given that the yield of precious metals

OVER 14 KM OF COPPER VEINS ENRICHED IN PRECIOUS METALS AT SLOVINKY-GELNICA PROJECT, SLOVAKIA Gold values to 8.8g Au/t and silver values to 181g Ag/t

For personal use only

The SS6000 Gold Mate Series For analyzing all precious metals and other elements from Mg to U

We are committed to providing accessible customer service. If you need accessible formats or communications supports, please contact us.

2014 Prospecting Report Faries Lake Property Cecil Township (G-2857) Thunder Bay Mining Division NTS 42 F 04

Current status and future plans The LARIS Laboratory

BRAMMER STANDARD ONLINE CATALOG - NICKEL SOLIDS. Cr/Al 4 Cr/Co 3 Cr/Fe 4, 5, 6 Cr/Fe/Mn/Nb ALLOY 9 Cr/Mn 8 Cr/Mo 7 Cr/Nb 8 Cr/W 8

Portable XRF Data Under International Reporting Codes. Dennis Arne Principal Consultant Geochemistry

Elemental analysis of historical and archaeological resources

Advancing EDS Analysis in the SEM Quantitative XRF. International Microscopy Congress, September 5 th, Outline

MMI SOIL SAMPLING REPORT. Oke Property. Oke Township, Ontario, Canada Porcupine Mining Division LATITUDE: 55 17'N LONGITUDE: 'W NTS: 73P 05 SE

CERTIFICATE OF ANALYSIS

WIDE ANGLE GEOMETRY EDXRF SPECTROMETERS WITH SECONDARY TARGET AND DIRECT EXCITATION MODES

Qualitative analysis tutorial for Tracer III SD and V+ data

LONG TERM STATISTICS OF X-RAY SPECTROMETERS

GOLDQUEST MINING CORP West Pender St., Vancouver, British Columbia, V6C 1G8, Canada

Diamond Drilling Report on the Nemegosenda Property. Claim S Chewett Township. Porcupine Mining Division E N UTM NAD83 Z17N

AMIS0416 Certified Reference Material. Certificate of Analysis

ELEMENTAL ANALYSIS OF GLASS BY LA-ICP-OES FOR FORENSIC DISCRIMINATION PURPOSES

DATA REPOSITORY METHODS. Field counting of K-feldspar megacrysts

Zaidi Embong and Husin Wagiran Physics Department, University Of Technology Malaysia, P.O Box 791, 80990, Johor Baharu

AMIS0211. Certified Reference Material. Certificate of Analysis

Surface Analysis of one Pound from the Egyptian Coins

Applications Information

Arab Journal of Nuclear Science and Applications, 46(4), (94-99) 2013

Technical Report. Collaborative Study 2017 on TSNA, ph, and Moisture (Oven Volatiles)

Dip-and-read paper-based analytical devices using distance-based detection with color screening

For Client Review Only. All Rights Reserved. Advanstar Communications Inc. 2005

Etching in Microsystem Technology

Application of a Bias-Current Modulation Technique to Radio- Frequency Glow Discharge Optical Emission Spectrometry

INTERNATIONAL ATOMIC ENERGY AGENCY

2006 DRILLING PROGRAM REPORT August-October, Volume 3 of6: Appendix 3. Lebel Property. Lebel Township Kirkland Lake Mining District Ontario

BRUKER ADVANCED X-RAY SOLUTIONS. SPECTROMETRY SOLUTIONS ARTAX mxrf SPECTROMETER

Bandpass Interference Filters

Sampling and Analyzing Paint. Presentation based on Toolkit Module C.ii.

Primary reference standards for precious metal analysis (gold alloys)

DWPF GC FILTER ASSEMBLY SAMPLING AND ANALYSIS

POLISHING COMPOUND RESIDUES IN GOLD JEWELLERY ALLOYS

Toolkit for Establishing Laws to Control the Use of Lead in Paint Module C.ii.

The Latest Advances in Axially Viewed Simultaneous ICP-OES for Elemental Analysis

Prodigy DC Arc. The Ultimate Solution for Elemental Analysis of Solid Samples

Product Bulletin July 2011

Appendix F Surface Water and Sediment Monitoring Results

Chemical Analysis of 1794 & 1795 U. S. Silver Coins Part 3 David Finkelstein & Christopher Pilliod October 20, 2018

Chemistry Project On Coin Analysis

TEST REPORT Page 1 of 28

TEST REPORT Page 1 of 30


Chemical Compositions of African Trade Bracelets (Manillas) via Energy Dispersive X-Ray Fluorescence

Poster Session: Graduate

Chemical Analysis of 1794 & 1795 U. S. Silver Coins Part 2 David Finkelstein and Christopher Pilliod October 6, 2018

AKM AK8973 and AK Axis Electronic Compass

Certificate of Accreditation

Manufacturer Part Number. Module 4: CMOS SRAM Analysis

ARTAX. Innovation with Integrity. Portable Micro-XRF Spectrometer. Micro-XRF

Elements and Symbols Card Games

Financing projects & exploration in Russia

X-ray Fluorescence of Some Egyptian Coins

New Aspects of Coin Measurement in Quality Inspection

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited. An ISO 9001 Certified Company

XRF Instrumentation. Introduction to spectrometer

Module 2: CMOS FEOL Analysis

New Certified Reference Materials for Chromatography

Temperature head transmitter itemp TC TMT 188

Certified Reference Material

Inorganic Pigments for Paints and Plastics

Various beams for RBS at IFIN-HH

A New EPMA Method for Fast Trace Element Analysis in Simple Matrices

ON THE ENERGY DEPENDENCE OF THE DETECTOR EFFICIENCY OF A Si-PIN DIODE

Exploring Color Mysteries in the United States Large and Small Numeral Postage Due stamps using X-ray Fluorescence Spectrometry

MICROANALYSIS WITH A POLYCAPILLARY IN A VACUUM CHAMBER

STMicroelectronics VL53L0B ToF Proximity Sensor

X-Ray Spectroscopy with a CCD Detector. Application Note

Wet particle source identification and reduction using a new filter cleaning process

Applications of Micro XRF for the Analysis of Traditional Japanese "Ainu" Glass Beads and other Artifacts

Possibilities for Thick, Simple- Structure Silicon X-Ray Detectors Operated by Peltier Cooling

Bosch Sensortec BMI160 Low Power IMU

Goodix GF6648 Touch Fingerprint Sensor. Exploratory Analysis

Transcription:

Certificate of Analysis First issued: July 2000 Version: December 2007 MA-2c Gold Ore Table l - Certified value for gold and provisional value for silver Element Ag (µg/g) Au (µg/g) Mean 0.51 3.02 Within-laboratory standard deviation 0.07 0.14 Between-laboratories standard deviation 0.13 0.13 95% confidence interval ± 0.10 ± 0.06 Status provisional certified Informational values are in table 2 on page 4 Source The raw material for MA-2c was donated by Kinross Gold from its operation in Kirkland Lake, Ontario. Description MA-2c is the fourth generation in a series with predecessors, MA-2, MA-2a and MA-2b, which are no longer available. The deposits of the area are known to contain electrum in a relatively simple siliceous ore. Intended Use MA-2c is suitable for analysis of gold, silver, majors, minors, and trace elements in gold ores. Examples of intended use are: for quality control in the analysis of samples of a similar type, method development, arbitration and the calibration of equipment.

Instructions for Use The assigned values pertain to the date when issued. CCRMP is not responsible for changes occurring after receipt by the user. MA-2c should be used as is. The contents of the bottle should be thoroughly mixed before taking samples. Method of Preparation The raw material was dried, crushed, ground and sieved to produce a product with a mesh size of less than 75 µm. After blending, the material was bottled in 400-g units. This is the only size available. State of Homogeneity A homogeneity assessment for gold was performed by an independent laboratory on 30-g samples using instrumental neutron activation analysis. Thirty gram samples were analysed for silver using fire assay with lead collection and determination by atomic absorption spectroscopy. A one way analysis of variance technique (ANOVA) was used to assess the homogeneity of gold and silver 1. The ratio of the between-bottle to within-bottle mean squares was compared to the F statistic at the 95% level of probability. No evidence of inhomogeneity was observed for gold or silver. Use of a smaller sub-sample will invalidate the use of the certified value and associated parameters. Further details are available in the certification report. Method of Certification Twenty industrial, commercial, and government laboratories participated in the 1998 interlaboratory certification program. Gold and silver were analysed by a variety methods. A statistical analysis of the data yielded recommended values for gold, and a provisional value for silver. Informational values were derived from the mean of five results from up to six laboratories using one or more of instrumental neutron activation; acid digestion followed by atomic absorption spectroscopy, inductively coupled plasma - atomic emission spectroscopy, or inductively coupled plasma mass spectrometry; fusion with lithium metaborate followed by x-ray fluorescence; and combustion methods. ANOVA was used to estimate the consensus value and other statistical parameters 1. Full details of all phases of the work, including statistical analysis, the methods and the names of the participants are contained in CCRMP Report 2000-2E. Legal Notice CCRMP has prepared this reference material and statistically evaluated the analytical data of the interlaboratory certification program to the best of its ability. The purchaser, by receipt hereof, releases and indemnifies CANMET-MMSL from and against all liability and costs arising out of the use of this material and information. December 2007 Page 2 of 5

Certification History MA-2c was originally released in July 2000. This version of the certificate, the second, was issued due to the expiration of the first version, and contains no changes in the values. Period of Validity These certified values are valid until December 31, 2030. Updates will be made via the CCRMP web site. Certifying Officers Joseph Salley, Data Processor Maureen E. Leaver, CCRMP Coordinator For Further Information The preparation and certification procedures used for MA-2c, including methods and values obtained by individual laboratories, are given in CCRMP Report 2000-2E. This report is available free of charge upon request to: CCRMP CANMET-MMSL (NRCan) 555 Booth Street Ottawa, Ontario, Canada K1A 0G1 Telephone: (613) 995-4738 Facsimile: (613) 943-0573 E-mail: ccrmp@nrcan.gc.ca Reference 1. Brownlee, K.A., Statistical Theory and Methodology in Science and Engineering; John-Wiley and Sons, Inc.; New York; 1960. December 2007 Page 3 of 5

Table 2 Informational values for the mean of up to six sets using a variety of methods Analyte Unit Mean SD Al % 6.70 0.29 As µg/g 9.10 2.32 Ba % 0.22 0.01 Be µg/g 3.74 0.48 Bi µg/g 0.66 0.05 C % 1.78 0.07 Ca % 4.76 0.05 Cd µg/g 0.7 0.1 Ce µg/g 141 2 Co µg/g 25 2 Cr µg/g 216 45 Cs µg/g 9.09 0.73 Cu µg/g 95 5 Dy µg/g 5.16 0.05 Er µg/g 2.26 0.02 Eu µg/g 3.15 0.15 Fe % 5.39 0.51 Ga µg/g 17.62 0.48 Gd µg/g 9.58 0.19 Hf µg/g 5.40 0.14 Ho µg/g 0.92 0.03 K % 3.20 0.06 La µg/g 61.49 8.48 Li µg/g 27.71 1.94 Lu µg/g 0.30 0.01 Mg % 2.91 0.32 Mn % 0.10 0.01 Mo µg/g 14.3 1.4 Na % 2.23 0.08 Nb µg/g 6.52 0.13 Nd µg/g 61.9 1.2 Ni µg/g 64 8 P % 0.24 0.02 Pb µg/g 25 4 Pr µg/g 16.26 0.20 Rb µg/g 147 5 S % 0.23 0.03 Sb µg/g 3.31 0.20 Sc µg/g 17.47 1.13 Si % 24.40 0.20 December 2007 Page 4 of 5

Table 2 continued Analyte Unit Mean SD Sm µg/g 12.0 0.4 Sr µg/g 1471 16 Ta µg/g 0.56 0.17 Tb µg/g 1.10 0.13 Th µg/g 9.2 2.6 Ti % 0.40 0.02 Tl µg/g 0.92 0.04 Tm µg/g 0.30 0.02 U µg/g 2.69 0.11 V µg/g 155 29 W µg/g 6.02 0.63 Y µg/g 24.5 1.4 Yb µg/g 2.00 0.09 Zn µg/g 93 9 Zr µg/g 211 38 LOI % 7.55 0.04 December 2007 Page 5 of 5