IP30 floor Box wooden floors

Similar documents
Raised Floor system LIMOGES Cedex. Phone : Fax :

Flush Floor system LIMOGES Cedex. Phone : Fax :

DLPlus. Dado and Skirting trunking LIMOGES Cedex. Phone : Fax :

Cablelink Plus Flush Technical

Cable Management Solutions with DLP TM

OptiLine 45 Floor boxes

DLP-S Trunking LIMOGES Cedex. Phone : Fax :

6. FLOOR INSTALLATIONS. Flush floor trunking system

Trunking ZH with performances specific to fire: Low-Fire Hazard

Workstation solutions

Trunking with performances specific to fire: Low-Fire Hazard

Our Marketing. Our Group. Our Mission. Our Quality Achievements

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Steel Cable Management SECURITY AREAS TOTAL PROJECT SOLUTIONS

Table and Furniture Base Fittings Plinth Adjusting Fittings

ENGINEERED BUILDING PRODUCTS. SplitHanger. mitek.com.au

J; ('& ): J; )'& ): J; +'& ): J; +(+ ): J;,)& ): 9WXb[ i[j J;9JKI <_n_d] <P%' '& <_n_d] IP 7ii[cXbo 7Z`kijc[dj 9WbYkbWj_ed \ehckbwi

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

SPECIAL EXTRUSIONS AND ACCESSORIES

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.)

WALL TO FABRICATED FLOOR

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

TECTUS. The completely concealed hinge system

On-roof system Alpha + Product catalogue

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

Type of system: fully automated operation

ADDINGTON STYLES TWO TONE CONSOLE TABLE

STANDARD 430E Series. Bottom mounted full extension drawer runners 430E E E E E E E E E4000

BX 3 system: fasteners for Mechanical & Electrical and Interior Finishing applications

CONTENTS. Hammerscrews White Zinc Plated 2 Hammerscrews Stainless Steel A Nylon Frame Anchors Yellow Zinc Plated 3 Nylon Plug 3

Installation Guide. Rockfon Eclipse

Aegis Heavy Capacity 20K Floor Scale

Barrier posts of steel tube Ø 76 mm, Ø 89 mm, 70 x 70 mm

TECTUS. The completely concealed hinge system

THE WETROOM SPECIALIST. EasyFit Dec Installation Guide

MEFA mounting accessories

Tall Wide Extra Deep Bookcase

White Media Storage Unit With Glass Doors

General Information...SA1-SA4

Sport-Thieme. Handball Goal. Assembly instruction. 3x2 m, Free-standing with Fixed Net Brackets

DLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation

Universal rotary hammer drill, 4 kg, SDS-plus. CHE 4-32 SDS-plus

Storage Cupboard 617/ /3481. Assembly Instructions - Please keep for future reference

Mounting a BalanceBox 400 to a brick wall

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

New Product Release: October 2014 Boone Racks

aluminium profile system

Thru Wall Floor Seals For New Installation

Sport-Thieme Handball Goal, 3x2 m, Free-Standing or socketed

DOCK WEDGE - STANDARD

Glass Front Sauna Room Assembly Manual

DobyGrip Accessories. Wire with Loop. Wire with Closed M6 & *M8 Eye Bolt. Wire with Carabina

SECTION SWINGING AUTOMATIC ENTRANCES

A Generic Sauna Room Assembly Manual

Salter Industries Spiral Stair

Football Goals 7,32x2,44 m

BX 3 system: fasteners for Interior Finishing, Mechanical and Electrical and Building Construction applications

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

Snap-on Aluminium trunking. Number(s) : /13/17/19/22/24/28/30/34/36/40/42,

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

Medium Storage Unit. Assembly Instructions - Please keep for future reference 833/2471

2013 Feeney (2/14) # B. Aluminum Railing Systems

Merlin / Prima. Patch Fittings. Patch Fittings. Merlin & Prima Series

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Merloni Elettrodomestici. Technical Fitting Manual FRIDGE. Language Issue/Edition Page GB /

TABLE OF CONTENTS. Impregnated... 1 NORDIC FENCE Fynbo FSC Certified... 1

Mounting instructions SZ210 Full-frame pedestal with screw-on tube with placement hinge, for type SCHATTELLO

FLATFROG MULTITOUCH 3200

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

Installation Instructions

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

BC-SERIES Screw-Jack Pedestal for Creative Design. Specifications text. Menu. Page 1/7

TECHNICAL INFORMATION

Installation Instructions

INSTALLATION MANUAL H A

REGATTA PATH LIGHT (RGP)

Pinnacle Technical. Bench and Shelf Trunking. cable management perimeter and distribution. Features.

Flooring Nails 6-D Flooring Nails $3.40 / 1# 6-D Flooring Nails $14.50 / 5# 8-D Flooring Nails $3.40 / 1# 8-D Flooring Nails $14.

A q u a r i u s 3 5 M e d i u m a n d A q u a r i u s 3 5 W i d e

TECTUS - New Versions. New Versions. The completely concealed hinge system

LSM-BE 7 - Lift System Medium with Box Enclosure

The new underfloor trunking system tehalit.bk broadway. Invisible perfection

2015 Feeney (8/15) # D. Aluminum Railing Systems

ALLIGATOR All-Purpose Anchors

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

ENCLOSURES ENCLOSURES

Material Packing Brown Grey Pine Black White

Sawing electrical cable ducts

Understairs Storage Unit

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off

WALL SHELVING SYSTEM 250/750

Control Panel Trunking IBOCO Wiring Systems

Universal flat-panel mount

Thread protection accessories are installed at the MODIX production factory and delivered with couplers.

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

Solid Pine Shoe Rack And Mirror

Tried-and-tested quality.

In-ceiling Housing. Installation Manual SHD-3000F2

PORTABLE UNITS BASKETBALL SCHELDE SUPER SAM MULTI-ADJUST

Transcription:

87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 2.Backboxes installation 2 à 7 3.Technical characteristics 8 à 9 4.Material characteristics 9 Cat.Nos 89688 1 RANGE. Metal backbox Cat.Nos 89634 : X4 X2 + and or Cat.Nos 89639 Floor Box with cover IP 30 with side exit of cables Cat.Nos 89688 1 / 9

2 BACKBOXES INSTALLATION Metal backbox Cat.Nos 89634 : Useful for heavy duty & water resistant floor boxes Cat.Nos 89688 The metal backbox is delivered with 4 sides for floor trunking & one accessory for screwing. Cat.Nos 89639 : set of 2 adaptors for conduit Ø 16, 20 et 25 1- Fixing of the backbox on the floor 2- Height adjustment of the backbox at the level of the concretes Level of the concrete 3- Installation of floor ductings or conduits Adaptors for floor ducting (delivered with backboxes) or (Cat.Nos 89639 : set of 2 adaptors for conduit Ø 16, 20 et 25) And pouring the concrete 2 / 9

2 COVER SUPPORT INSTALLATION Useful for IP30 floor box wooden floors Cat.Nos 89688 - Set for normal load (6mm deflection at 8KN) Cat.Nos 89683 - Set for heavy load (3mm deflection at 20KN) Cat.Nos 89684 Load up to 8 KN Load up to 20 KN 3 / 9

2 FLOOR BOX WITH COVER IP30 WITH SIDE EXIT OF CABLES Floor Box with cover IP 30 with side exit of cables Cat.Nos 89688 - Cover IP 30 with side exit of cables Cat.Nos 89688 - Wiring accessories support - Wiring accessories frames Set for normal load Cat.Nos 89683 or Set for heavy load Cat.Nos 89684 Metal backbox Cat.Nos 89634 4 / 9

2 FLOOR BOX WITH COVER IP30 WITH SIDE EXIT OF CABLES INSTALLATION Wiring accessories support Useful for installation of IP30 floor box wooden floors Cat.Nos 89688 1- Support fixing in set Cat.Nos 89683 or 89684 2- Screws & Cover support fixing With the set for standard load Cat.Nos 89683, use the screws M6x40(x4) With the set for heavy load Cat.Nos 89684, use the screws M6x70(x4) or M6x100(x4) depending on the screed level 3- Support height adjustment for cover 4- Locking 5 / 9

2 FLOOR BOX WITH COVER IP30 WITH SIDE EXIT OF CABLES Floor Box with cover IP 30 with side exit of cables Cat.Nos 89688 1- Cover installation 2- Before fitting coating, adjustment of the level of the inside of the cover with the help of the glue (depth of the glue = difference between the coating thickness and the cover height) 3- Fitting the tiles 4- Installation of screw or hook 5- Insertion and connection of the cable 6- Repositioning of the cover 6 / 9

2 WIRING ACCESSORIES FRAMES INSTALLATION Wiring accessories frames Useful for installation of IP30 floor box wooden floors Cat.Nos 89688 With power (8 mod. + tightener) With data(9 mod.) Wiring accessories frames in an IP30 floor box wooden floors, look at hereunder drawing. The wiring accessories frames are delivered with a card allowing the installation and the removing of the frames in the bottom of the floor box. Insertion of the card for installation of the wiring accessories frames Insertion of the card to remove the wiring accessories frames 7 / 9

3 TECHNICAL CHARACTERISTICS Metal backbox including 4 sides for floor trunking & one accessory for height adjustment. Cat.Nos 89639 : set of 2 adaptors for conduit Ø 16, 20 et 25 Concrete height The backbox is adjustable in height, its height has to be the same as the concrete For fixing adaptors for conduits in the bottom of the backbox, look at hereunder drawing) 1 2 Important: Before the installation of the final coating, to make a joint around the support lid for a good sealing. Concerning the installation of tiling, to leave 5 mm all around the support lid to make a joint there. The interior of floor box does not have to receive waste/dust during the installation of equipment as before the installation of the lid (this guaranteeing the effectiveness of the joint inside the box) Joint inside the box Attention to pose the whole on the level well it final ground to avoid the water stagnation or all other liquidates (floor boxes are recommended only of use inside) 8 / 9

3 TECHNICAL CHARACTERISTICS Dimensions (for support & cover): Resistance to load with support : For standard load 6mm deflection at 8KN For heavy load 3mm deflection at 20KN Index of protection (IP) IP30 with cover closed, plugs no connected, wiring accessories frames IP24 Installation principe : In order to install wiring accessories, it is necessary to adjust the backbox at the level concrete of 105mm. Dimension in mm of the cover of floor boxes Cat.Nos 89688 : 30 / 24 271 262 4 MATERIAL CHARACTERISTICS. Covers : Stainnless steel 304L Backboxes : Galvanized steel+ Zamac Wiring accessories frames: polypropylene 9 / 9