RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Similar documents
RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Technical Data Sheet. x1000. kwh R Y B

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

Digital Multifunction Instrument - Rish Master 3440

Data Sheet. RISH Master Record %THD

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Technical Data Sheet AMIK 300 / 301

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

AMIK 200 / 201 Technical Data Sheet

Technical Data Sheet

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Alpha 50. Technical Data Sheet. Special Features

RS Pro ENGLISH. Datasheet

RS Pro ENGLISH. Datasheet

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Jewell DPM EINE BEST IN CLASS

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

AMIK Three Phase Digital Panel Meters

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Integra 1560 and 1580 Digital Transducer Systems

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Operating Guide October 2006

Theta 20A / 20V. Technical Data Sheet. Special Features

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

Programmable DPM RISH EINE

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MultiCube Multi-Function Electricity Meter. Installation and Operation

Theta Hz. Technical Data Sheet. Special Features

Application: Salient Features: Products Features:

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Centrale de mesure Power Meter PM500 Merlin Gerin

Power-meters three-phase

Energy Management Energy Analyzer Type EM210 MID

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Meter Type EM21 72R Retro-Fit

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Energy Division

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Energy Management Energy Meter Type EM340

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Installation and Operating Instructions

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Energy Management Energy Meter GM3T E GM3T-RS485 E

Digital Multifunction Meter - RISH Integra 2000

Energy Management Modular Smart Power Transducer Type SPT-90

3. Phase Indications. Units of measurement. kwh. Units of measurement

Energy Management Energy Meter Type EM111

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Energy Management Energy Meter Type EM112

Energy Management Energy Meter GM3D

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Energy Management Energy Meter Type EM110

MT 560/UMT TRANSDUCER & ANALYZER

Operating Manual RISH EM 1320/30/ _Rev. C - 9/2014

Power Meter Series PM3200 Functions and characteristics

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

Energy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft

Programmable AC Current Transducer MT418

Introduction DIN rail mounted electricity meters

OPERATING MANUAL Rish Eine. Size: 48 x 96 Size: 96 x 96

Solid-state Timer H3DS

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

Energy Management Energy Analyzer Type EM112

Ziegler EM 1320/30/40

Contents. Introduction and description Package contents Device identification PM Options... 80

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Power Meter Series PM9

Conzerv EM6400NG series

1 INTRODUCTION ORDER CODE / INFORMATION

Programmable AC Voltage Transducer MT416

DPF-MAC Auto power factor controller

EM-72 Electricity Meters for Current Transformers

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

Energy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications

Analogue temperature controllers

Energy counting and measurement

ME432 Three-phase Power Meter

Energy Management Energy Meter Type EM110

DM-III Multitest & DM-III Multitest F Power Quality Recorders

05/09/2012

Transcription:

Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit provides LED indication for healthy phase, load reverse current. The RISH EM 3490SS is available in two version 3phase 4 wire / 3 wire unbalanced load and single phase and is ideal for secondary metering in industrial applications. RISH EM 3490 SS Product Features: Ø class 1.0 Accuracy Ø Available in 3 phase 4 wire, 3 phase 3 wire and single phase version Ø Indication: Healthy phase, Reverse Current Ø Applicable to Standards IEC 62053-21 Ø 8 Digit auto-ranging auto-resettable seven segment LED display counter Ø True RMS measurement Ø Fully programmable CT ratios Ø Fully programmable PT ratios Ø On site programmable 3 phase 4 wire or 3phase 3 wire Ø Fully isolated current input Ø Built in transient protection Ø State of art SMD technology Ø Pulse output: one potential free relay contact Ø Remote data reading through modbus (Rs485) Ø Programmable Energy format & Energy rollover count Indication: 3 phase voltage status: Three indications are provided, one for each voltage phase. Three illuminated indication indicate active monitoring of each of the three phases. In case if any one phase voltage is missing the appropriate indication will switch OFF.However the meter will continue to accurately measure energy for the available voltage phases. In case of phase sequence error all three indication will start blinking. Reverse connected current transformer : Three indications are provided for each of three phases. Illumination of the indication indicates a reverse connected CT. The meter will continue to register the energy consumption even if the CT s are reverse connected. Pulse Indication: The unit features a red LED pulse indicator which flashes at rate proportional to measured power (3600 impulses / kwh). This is used for verifying calibration of the meter on site. Energy Count storage: In case of power failure, the instrument memorizes the last energy count. Every 40 sec, the instrument updates the energy counter in the non-volatile memory. Programmable Energy format & Energy rollover count: Customer can assign the format for energy display on MODBUS (RS485) in terms of W, kw or MW. Additional to this, customer can also set a rollover count from 7 to 14 digits (for W), 7 to 12 digits (for kw) & 7 to 9 digits (for MW), after which the energy will roll back to zero. The above settings are applicable for all types of energy. Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen. The displayed screen will get memorized only if user keeps this screen for minimum 40 sec duration before power failure for fixed screen mode. Configuration of the Instrument via MODBUS: The instrument settings can be configured locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485). Note: The MODBUS communication parameters can only be set locally via front panel keys in the Programming mode. User Assignable Registers for MODBUS: Customer can assign MODBUS register address as per his need for faster response time. Low back depth: The instrument has very low back depth (behind the panel) of less than 80 mm in spite of optional features like pulse output Enclosure Protection for dust and water: conforms to IP 54 (front face) Compliance to International Safety standards Compliance to International Safety standard IEC 61010-1- 2001 Page 1/6

Technical Specifications: Input Voltage: Input Voltage 110V L-L (63.5V L-N) 230V L-L (133V L-N) 415V L-L (239.6V L-N) PT Secondary Settable Range 100V 120V L-L (57V 69V L-N) 121V 239V L-L (70V 139V L-N) 240V 480V L-L (140V 277V L-N) Input Current: Nominal input current 1 or 5A AC RMS (To be specified while ordering) System CT primary values Std. values up to 4kA (1 or 5 Amp ) Starting Current 0.4% of nominal Auxiliary Supply: AC Auxiliary Supply 110 V AC -15% / +20% 230 V AC -15% / +20% 380 VAC-15% / +20 ACDC Auxiliary Supply 100V 250 VAC DC DC Auxiliary Supply 12..48 VDC AC Auxiliary supply frequency range 45 to 66 Hz VA Burden: Nominal input voltage burden Nominal input current burden AC Supply burden Overload Withstand: Voltage Current Operating Measuring Ranges Voltage Current Frequency Power Factor < 0.2 VA approx. per phase < 0.6 VA approx. per phase 4 VA 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x for 1 second, repeated 5 times at 5 min 5 120% of rated value 5 120% of rated value 40 70 Hz 0.5 Lag... 1... 0.8 Lead Reference conditions for Accuracy: Reference temperature 23 C +/- 2 C Input waveform Sinusoidal (distortion factor 0.005) Input frequency 50 or 60 Hz ±2% Auxiliary supply voltage Rated Value ±1% Auxiliary supply frequency Rated Value ±1% Voltage Range 50... 100% of Nominal Value. Current Range 10... 100% of Nominal Value. Power Factor Power Accuracy: Active energy (kwh) Voltage Current Frequency Active Power Reactive Power Apparent Power Power Factor Phase angle 0.5 lag.1.0.8 lead 10... 100% of Nominal Current & 50... 100% of Nominal Voltage. 1 % (IEC 62053-21) Active P.F. 0.5 lag... 1...0.5 lead 0.15% of mid frequency 1 % of Unity 1 % of range Measurement error is normally much less than the error specified above. Variation due to influence quantity is less than twice the error allowed for reference condition Page 2/6

Technical Specifications: Counter: Counter: Reading resolution Indication: Indicator display: Pulse indicator Enclosure style: Enclosure style Enclosure material Terminals Fixing Dimension: Dimension Panel cutout Weight 8 digit seven segment LED display Auto ranging 3 : Voltage phase monitoring 3 : Reverse connected CT warning. Red LED flashing at a rate proportional to measured power. 96 X 96 DIN Quadratic) Polycarbonate (Self extinguish & non dripping as per UL 94 V-0) M4 Screw Type 4 side clamps 96mm high x 96mm wide x 80mm deep 92mm x 92mm 320-400 gm Applicable Standards: EMC IEC 61326 Immunity IEC 61000-4-3. 10V/m min Level 3 industrial low level Safety IEC 61010-1-2001, Permanently connected use IP for water & dust IEC60529 Pollution degree: 2 Installation category: CAT III 300V ac rms High Voltage Test 2.2 kv AC, 50Hz for 1 minute between all electrical circuits Environmental Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Enclosure -10 to +55 C -20 to +65 C 0... 90% non condensing Minimum 3 minute 15g in 3 planes 10... 55 Hz, 0.15mm amplitude IP54 (front face only) Pulse output Relay contact: 1 NO Switching Voltage & Current for Relay: 240 VDC,5 A Default pulse rate divisor: 1 per Wh (up to 3600W), 1 per kwh (up to 3600kW), 1 per MWh (above 3600 kwh) Other Pulse rate divisors (applicable only when Energy on RS485 is in W): 10 1 per 10 Wh (up to 3600W), 1 per 10kWh (up to 3600kW), 1 per 10MWh (above 3600 kw) 100 1 per 100Wh (up to 3600W), 1 per 100kWh (up to 3600kW), 1 per 100MWh (above 3600 kw) 1000 1 per 1000Wh (up to 3600W), 1 per 1000kWh (up to 3600kW), 1 per 1000MWh (above 3600 kw) Pulse duration: 60 ms, 100 ms or 200 ms Page 3/6

Displayed Parameters: Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire 1. Active Energy (kwh) (8 digit resolution) ü ü ü Parameters Through MODBUS (Optional) : Sr No Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire 1. Active Energy (Wh) ü ü ü 2. System Volts ü ü ü 3. System Current ü ü ü 4. Volts L1 N ü û û 5. Volts L2 N ü û û 6. Volts L3 N ü û û 7. Volts L1 L2 ü ü û 8. Volts L2 L3 ü ü û 9. Volts L3 L1 ü ü û 10. Current L1 ü ü û 11. Current L2 ü ü û 12. Current L3 ü ü û 13. Frequency ü ü ü 14. System Active Power (kw) ü ü ü 15. Active Power L1 (kw) ü û û 16. Active Power L2 (kw) ü û û 17. Active Power L3 (kw) ü û û 18. System Re-active Power (kvar) ü ü ü 19. Re-active Power L1 (kvar) ü û û 20. Re-active Power L2 (kvar) ü û û 21. Re-active Power L3 (kvar) ü û û 22. System Apparent Power (kva) ü ü ü 23. Apparent Power L1 (kva) ü û û 24. Apparent Power L2 (kva) ü û û 25. Apparent Power L3 (kva) ü û û 26. System Power Factor ü ü ü 27. Power Factor L1 ü û û 28. Power Factor L2 ü û û 29. Power Factor L3 ü û û 30. System Phase Angle ü ü ü 31. Phase Angle L1 ü û ü 32. Phase Angle L2 ü û û 33. Phase Angle L3 ü û û 34. Apparent Energy (VAh ) ü ü ü Page 4/6

Electrical Connections: For 3 Phase 4 Wire Unbalanced Load 2 5 8 11 1 3 4 6 7 9 13 14 L1 L2 L3 N L N + - AUX SUPPLY For 3 Phase 3 Wire Unbalanced Load 2 5 8 1 3 7 9 13 14 L1 L2 L3 For Single Phase L N + - AUX SUPPLY 2 11 1 3 13 14 L1 L2 L3 N L N + - AUX SUPPLY It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5 mm. 2 2 Permissible cross section of the connection wires: <= 4.0 mm single wire or 2 2.5 mm fine wire. Dimensions 3.78 3.15 3.62 96 mm 80 mm 92mm+0.8 3.78 96 mm Front Display Area Panel Cutout 3.62 92mm+0.8 Max Panel Thickness 0.19, 5mm Page 5/6

Ordering information System Type (Connection network) 3 Phase (programmable as 4 Wire or 3 Wire on site) 3 1 Phase 1 Input Voltage 110V L-L (63.5V L-N) 110 230V L-L (133V L-N) 230 415V L-L (239.6V L-N) 415 440V L-L (254V L-N) 440 Input Current 5 Amps 5 1 Amps 1 AC Auxiliary Voltage 110 V AC -15% / +20% L 230 V AC -15% / +20% M 380 VAC-15% / +20 % H AC/DC Auxiliary Supply Voltage 100 250V AC/DC +/- 10% AD 12V 48V V DC +/- 10 % D Optional: MODBUS (RS485) output R MODBUS Option not used Z Optional: Pulse Output for energy measurement Pulse output used P Pulse Output option not used Z Order Code Example: RISH Master 3490SS 3 415-AD-R-P Ordering Code RISH EM 3490 SS RISH Master 3490SS, 3 phase( programmable onsite as 4 wire or 3 Wire), 415L-L nominal voltage, 5Amps nominal current,100 250V AC DC Auxiliary supply, with MODBUS (RS485),with pulse output Types AC Aux 100...250VACDC 12 48 VDC (110V, 230V, 380V) Aux Aux 3490 SS ü ü ü 3490 SS + 1 pulse ü ü ü 3490 SS + Rs485 ü ü ü 3490 SS + 1 pulse + Rs485 û ü ü Rishabh Instruments always tries for Improvement and therefore product specifications are subject to change without notice Page 6/6