NPN TRANSISTOR OUTPUT MODULE

Similar documents
Status Indicator LED PWR LINK COL

DISCRETE INPUT MODULE, 16 points

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2DYS SEN TRONIC AG

WJM POTENTIOMETER TRANSMITTER BEFORE USE... COMPONENT IDENTIFICATION POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (field-programmable)

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

JPQ2 PULSE ACCUMULATOR

JTY2 PULSE DURATION RECEIVER BEFORE USE... COMPONENT IDENTIFICATION

PPD COMPONENT IDENTIFICATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PULSE ISOLATOR MODEL. (built-in excitation)

n FRONT PANEL CONFIGURATIONS

MODEL: R9CWTU. Remote I/O R9 Series. EXTENSION UNIT 1: With connection

R7L-YV2. DC VOLTAGE OUTPUT MODULE, 2 points MODEL BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL R7L-YV2

MODEL: R30US4. Remote I/O R30 Series

R9CWTU BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MULTI POWER MONITORING UNIT MODEL. (clamp-on current sensor CC-Link)

MODEL: R7G4HML3. Remote I/O R7G4H Series MECHATROLINK I/O MODULE (MECHATROLINK-III)

MULTI POWER TRANSDUCER MODEL LSMT4

MODEL: M6SXT. POWER INPUT DC Power R: 24 V DC

MODEL: DAST-20. Telemetering System

MODEL: DLS. Telemetering System

Palm-sized, 16-channel Relay Terminals

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

HPX-ET Series. Gang-mounted Distributed Remote Cluster Type Fiber Optic Photoelectric Sensors. Specifications. click

MODEL: WL40MW1F. Wireless I/O WL40F Series

JRQ2 ENCODER POSITION TRANSMITTER MODEL. Plug-in Signal Conditioners M-UNIT. (field-programmable; built-in excitation)

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

Module Type Controller SRX. DeviceNet Communication Instruction Manual IMS01N17-E2 RKC INSTRUMENT INC.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Digital Interface Option "OPC-E1-DIO"

Remote Sensor Amplifier Terminal

Module Type Controller SRV. DeviceNet Communication Instruction Manual IMS01P11-E1 RKC INSTRUMENT INC.

High-speed, wireless communication with easy installation and simple wiring!! *Antenna sold separately. 250 m range. Antenna with cable available

MODEL: M2VF MODEL: M2VF [1][2] [3][4]


(For Rotary Servomotors)

FR-A7AX FR-A7AX E kit

ES Series Features Detecting distance twice that of conventional

D25122(K) D25123(K) D25124(K) D25213(K)

RT-3 UNIT RELAY 4-POINT TERMINAL

Easy operation even for beginners! Optimum settings can be realized with simple operations

onlinecomponents.com

Inductive Proximity Sensor

RT-3 UNIT RELAY 4-POINT TERMINAL

CTC CT TRANSMITTER. (clamp-on current sensor) BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL CTC

Capacitive Proximity Sensor

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

MODEL: W2TS. Mini-MW Series

Self-Powered Counters H7ET

Solid-State Digital Counter H7AN

MODEL: M1EXT. with Display M1E Series

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

MODEL: MRP6. Final Control Elements

Remote Sensor Amplifier Terminal

4th digit. 7th digit. digits. Specifications. Interface. MECHATROLINK-2 communications Reference Type (for rotary servomotors)

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

This section is specifically about safety matters

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

MODEL: MRP6D. POWER INPUT DC Power R: 24 V DC. Final Control Elements

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

3050 Stereo Power Amplifier

MODEL: DA3. Plug-in Signal Conditioners M-UNIT

P1-04THM Analog Input

MODEL: RPPD. Plug-in Signal Conditioners M-UNIT. [2] INPUT 2 Must be the same code as the one chosen for Input 1.

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Field Network SRT Series

Long-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

PG Interface Card "OPC-E2-PG"

DeviceNet Communication Converter COM-H. Instruction Manual RKC INSTRUMENT INC. IMR01L01-E5

Name Number of I/O points (words used) Model Antenna style. 512 outputs max. (32 words) Magnetic Base Antenna (1) --- WD30-AT001 (See note.

Phase-sequence Phase-loss Relay

Varispeed G7/F7 OPTION CARD MECHATROLINK COMMUNICATIONS INTERFACE CARD INSTRUCTIONS MODEL: SI-T

SCC-DI01 Isolated Digital Input Module

MODEL: R7C. Remote I/O R7 Series. CC-Link I/O MODULE. [2] POWER INPUT DC Power R: 24 V DC

Model Number Structure

FA Wireless SS Terminals

Sockets. SU Series: DIN Rail Snap-Mount Sockets. F-6 USA: (800) 262-IDEC or (408) , Canada: (888) 317-IDEC ➀➁➄➅ ➁➂➃➄

I-2533CS series User Manual

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

MODEL: TC10EM. Temperature Controller TC10 Series

Digital Input Module. ST-1xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

IP Series DUAL POWER AMPLIFIERS

SI unit PRODUCT NAME EX140-SCS1 EX140-SCS2

INVERTER INSTRUCTION MANUAL. 16-bit digital input function. Plug-in option PRE-OPERATION INSTRUCTIONS INSTALLATION CONNECTION DIAGRAM AND

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

Solid-state Twin Timer

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Boulder W Mono Power Amplifier

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

Sendai Office , Ichiban-cho, Aoba-ku, Sendai, Miyagi pref TEL FAX

Transcription:

INSTRUCTION MANUAL NPN TRANSISTOR OUTPUT MODULE (3 points, MECHATROLINK- I/II use) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. PACKAGE INCLUDES: Discrete output module... () Mounter slider...... () MODEL NO. Confirm that the model number described on the product is exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVES The actual installation environments such as panel configurations, connected devices and connected wires may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure CE conformity. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: 4V DC rating: 4V ±0%, approx. 0mA GENERAL PRECAUTIONS Before you remove the unit or mount it, turn off the power supply and input signal for safety. Before you remove the terminal block or mount it, turn off the power supply and output signal for safety. ENVIRONMENT Indoor use When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation. Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within 0 to 55 C (3 to 3 F) with relative humidity within 30 to 90% RH in order to ensure adequate life span and operation. WIRING Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The unit is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. P. / 8

89ABCDEF03457 89ABCDEF03457 FRONT VIEW MECHATROLINK Connector Station Address Setting Rotary SW Status Indicator LED Operating Mode Setting DIP SW (SW) Discrete Output Status Indicator LED PWR ERR RD 0 3 4 ON Y0 3 4 5 7 Y 8 9 0 3 4 5 X0 3 4 5 7 X 8 9 0 3 4 5 SD STATION ADD. 4 5 7 3 0 3 4 5 7 8 3 4 5 7 8 9 8 9 30 3 3 33 34 35 3 9 0 3 4 5 7 Power Supply Terminals Ouput Terminals STATUS INDICATOR LED ID COLOR FUNCTION PWR Green Turns on when the internal power is supplied normally. ERR Red Turns on in no station address setting error. SD Green Turns on when the module is transmitting. RD Green Turns on when the module is receiving. STATION ADDRESS Station Address is selected between 0H and 7FH in hexadecimal. (Because of simple I/O certain numbers may not be selectable depending on the master types. Refer to the instruction manual of the master unit.) The left switch determines the MSD, while the right switch does the LSD of the address. (Factory setting: H) OPERATING MODE MECHATROLINK MODE Choose MECHATROLINK-I or -II, and the data size. SW- and SW- are used. SW- SW- MECHATROLINK OFF OFF MECHATROLINK-II (3 byte mode) (*) ON OFF MECHATROLINK-II (7 byte mode) OFF ON Unused ON ON MECHATROLINK-I (7 byte mode) (*) Factory setting Caution! - SW-3 and SW-4 are unused. Be sure to turn off unused channels. DISCRETE OUTPUT STATUS INDICATOR LED LED green indicators shows the signal status. ON : LED ON OFF : LED OFF POWER SUPPLY TERMINAL ASSIGNMENT Station Address Setting (LSD) Station Address Setting (MSD) 4 5 7 NC NC +4V 0V 3 NC NC FE. NC. NC 3. FE 4. NC 5. NC. +4V 7. 0V - - Functional earth - - Power supply (4V DC) Power supply (0V) P. / 8

OUTPUT TERMINAL ASSIGNMENT 0 3 4 5 7 8 V+ Y Y3 Y5 Y7 Y9 Y Y3 Y5 3 4 5 7 8 9 V- Y0 Y Y4 Y Y8 Y0 Y Y4 8 9 30 3 3 33 34 35 3 V+ Y7 Y9 Y Y3 Y5 Y7 Y9 Y3 9 0 3 4 5 7 V- Y Y8 Y0 Y Y4 Y Y8 Y30 NO. ID FUNCTION NO. ID FUNCTION V Out. Common 0 V+ External excitation Y0 Output 0 Y Output 3 Y Output Y3 Output 3 4 Y4 Output 4 3 Y5 Output 5 5 Y Output 4 Y7 Output 7 Y8 Output 8 5 Y9 Output 9 7 Y0 Output 0 Y Output 8 Y Output 7 Y3 Output 3 9 Y4 Output 4 8 Y5 Output 5 NO. ID FUNCTION NO. ID FUNCTION 9 V Out. Common 8 V+ External excitation 0 Y Output 9 Y7 Output 7 Y8 Output 8 30 Y9 Output 9 Y0 Output 0 3 Y Output 3 Y Output 3 Y3 Output 3 4 Y4 Output 4 33 Y5 Output 5 5 Y Output 34 Y7 Output 7 Y8 Output 8 35 Y9 Output 9 7 Y30 Output 30 3 Y3 Output 3 P. 3 / 8

MOUNTING INSTRUCTIONS DIN RAIL MOUNTING Mounting ) Set the upper hook at the rear side of the unit on the DIN rail. ) Push in the lower. SURFACE MOUNTING ) Insert the two DIN rail mounter sliders until it clicks once, as shown below. ) Mount the unit with M4 screws referring the Mounting Requirements. (Torque:.4N m) Dismounting ) Push down the DIN rail mounter slider with tip of a minus screwdriver. ) Pull the lower of the unit. 3) Remove the upper hook of the unit from the DIN rail. 3 EXTERNAL DIMENSIONS unit: mm (inch) 35 (9.5) 0 (8.) 0 (8.7) 47 (.85) 45 (.77) DIN RAIL 35mm wide 50 (.97) 4 5 7 0 3 4 5 7 8 8 9 30 3 3 33 34 35 3 3.5 (.4) 5(.) 3 7 M3 SCREW TERMINALS FOR POWER 3 4 5 7 8 9 9 0 3 4 5 7 3 M3 SCREW TERMINALS FOR OUTPUT - 4.3 dia. 4 deep ( -.7 dia.. deep) [4 (.)] P. 4 / 8

CONNECTION DIAGRAM Connect the unit as in the diagram below. * * FE MECHATROLINK CONNECTOR MECHATROLINK CONNECTOR 3 3 4 5 7 8 9 V Y0 Y Y4 Y Y8 Y0 Y Y4 Output Connection Examples V+ V+ V 8 0 9 V Y0 Y3 3 + MOUNTING REQUIREMENTS unit: mm (inch) - M4 0 (8.) WIRING INSTRUCTIONS TORQUE Wiring screw for separable terminal: 0.5 N m Fixing screw for separable terminal: 0.5 N m 4V DC 0V 7 0 3 4 5 V+ Y Y3 Y5 Y7 Y9 SOLDERLESS TERMINAL mm (inch) Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Solderless terminals with insulation sleeve do not fit. Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd Applicable wire size: 0.5.5 mm (AWG ) 3.3 (.3) max 7 8 Y Y3 Y5 (.4) max mm (inch) 9 0 V Y Y8 HOW TO UNMOUNT THE SEPARABLE TERMINAL The separable terminal of the unit is piece constructions. It is possible to remove the terminal by loosening two screws of terminal alternately. Y0 3 Y 4 Y4 5 Y Y8 7 Y30 8 V+ 9 Y7 30 Y9 3 Y 3 Y3 33 Y5 34 Y7 35 Y9 3 Y3 *. MECHARTROLINK connectors are internally connected. The network cable can be connected to either one. Note: In order to improve EMC performance, bond the FE terminal to ground. Caution: FE terminal is NOT a protective conductior terminal. P. 5 / 8

MECHATROLINK COMMUNICATION MECHATROLINK-I Baud rate: 4 Mbps Transmission distance: 50 m max. Distance between stations: 30 cm min. Transmission media: MECHATROLINK cable (Model JEPMC-W003-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves: 5 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.) Transmission cycle: msec. (fixed) Data length: 7 byte MECHATROLINK-II Baud rate: 0 Mbps Transmission distance: 50 m max. Distance between stations: 50 cm min. Transmission media: MECHATROLINK cable (Model JEPMC-W003-x-E, Yaskawa Controls Co., Ltd.) Max. number of slaves: 30 (The maximum number of slaves might change depending on the master unit. Refer to the manual of the master unit.) Transmission cycle: 0.5msec., 0.5 msec., msec.,.5 msec., msec.,.5 msec., 3 msec., 4 msec., 8 msec. Data length: 7 byte / 3 byte selectable (Must choose identical data size for all stations within the network) P. / 8

MECHATROLINK RELATED COMMANDS R7K4FML (Simple I/O) communicates with I/O service with no processer, therfore it uses a connectionless communication protocol. There is no application layer either; the R7K4FML interchanges I/O data via data link layer. MECHATROLINK DATA LINK LAYER COMMAND DESCRIPTIONS The following tables explain the two Commands supported by the R7K4FML. MDS Command (04H) Data Format BYTE COMMAND RESPONSE REMARKS 0 MDS (04H) S(0) (90H) Message Data Search (MDS) Command: Read the ID from slave station(s) S(0): Response to MDS 0 0 3 0 0 4 0 0 5 0 0 0 0 7 0 0 8 0 0 9 0 0 0 0 0 0 0 0 0 3 0 0 4 0 0 5 0 0 0 0 ID All 0 7 0 0 Byte 7 through 3 are always 0 in the 3-byte mode. : : : These bytes are unavailable for MECHATROLINK-I and MECHATROLINK- 3 0 0 II in the 7-byte mode. CDRW Command (03H) Data Format BYTE COMMAND RESPONSE REMARKS 0 CDRW (03H) ACK (0H) Cyclic Data Read/Write (CDRW) Command: Link transmission Acknowledge (ACK): Positive response to CDRW Out Data: Lowest In Data: Lowest Order of data: Little Endian 3 4 5 7 8 9 0 3 4 5 Out Data: Highest In Data: Highest 7 : 3 Out Data: Highest In Data: Highest Byte7through 3 are unavailable for MECHATROLINK-I and MECHATROLINK-II in the 7-byte mode. (Only available for MECHATROLINK-II in the 3-byte mode) P. 7 / 8

I/O DATA DESCRIPTIONS 7-BYTE MODE 3 points output data (Out Data) Byte Bit 7 Bit Bit 5 Bit 4 Bit 3 Bit Bit Bit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 5 0 0 0 0 0 0 0 0 : 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 Out 7 Out Out 5 Out 4 Out 3 Out Out Out 0 4 Out 5 Out 4 Out 3 Out Out Out 0 Out 9 Out 8 5 Out 3 Out Out Out 0 Out 9 Out 8 Out 7 Out Out 3 Out 30 Out 9 Out 8 Out 7 Out Out 5 Out 4 3-BYTE MODE 3 points output data (Out Data) Byte Bit 7 Bit Bit 5 Bit 4 Bit 3 Bit Bit Bit 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 5 0 0 0 0 0 0 0 0 : 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 9 Out 7 Out Out 5 Out 4 Out 3 Out Out Out 0 30 Out 5 Out 4 Out 3 Out Out Out 0 Out 9 Out 8 3 Out 3 Out Out Out 0 Out 9 Out 8 Out 7 Out 3 Out 3 Out 30 Out 9 Out 8 Out 7 Out Out 5 Out 4 0: OFF : ON At the loss of communication, output is hold. (last data correctly received is hold) P. 8 / 8