control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

Similar documents
control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS

Analogue temperature controllers

Engineer s Guide. Section 9. Practical Solutions. Switches and NAMUR Sensors

MC2: Practicality for Calibration

S T T U S I N S T R U M E N T S

Portable Multi-Channel Recorder Model DAS240-BAT

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High Performance Process & Temperature Controllers

CONTA-ELECTRONICS. Converter Units

Excellent low-cost Process & Temperature Controllers

PROCESS & TEMPERATURE CONTROLLERS

Fuzzy Temperature Controllers E5AF

Programmable with Electronic Assistant Simulink

Basic module X-TIO FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10 FAIL/RUN RX/TX EVENT1 EVENT2 EVENT3 EVENT4 X10. Communications (RS-485)

Ordering Part Numbers: SAE J1939 version Controller: AX022400

Temperature Transmitters - Head Mounted

Conductivity Analyzer

PL420 PROGRAMMABLE LOGIC CONTROLLER

Industrial Modbus I/O Modules

OVEN INDUSTRIES, INC. Model 5C7-362

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Temperature Transmitters - DIN Rail Mounted

Ultrasonic level transmitter, non-contact

Analog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V

ADAM 4000/4100 Series

Process displays For standard signals, temperature, resistance measurement

SRC-110 Series Zone Controllers with Modbus RTU

CT325 Miniature DC Temperature Controller

Electronic Thermostat TE-1 Version according to EN

Preset counters, electronic

Data Acquisition Modules/ Distributed IO Modules

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

P5201 Universal Programmable Transmitters with Galvanic Isolation

DPR100 C/D PEN AND MULTIPOINT 100 mm DIGITAL RECORDERS

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Temperature Controller

LST400 Ultrasonic level / open channel flow transmitter

CI/SfB (57.7) 1st Edition

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

DP2000 ORDERING GUIDE To Order MODEL NO.

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

General Specifications

2002-ALM USER MANUAL

dtrans Az 01 µp Indicator/Controller for analytical measurement

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

Jacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)

RCMS460 and RCMS490 Series

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

General Specifications

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Digital Indicator DS 96/48 PK

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

New Signal Conditioner VJ series

MTL7700 SERIES BARRIER APPLICATIONS

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

DC1010/DC1020/DC1030/DC1040

Beamex MC2 HAND-HELD CALIBRATOR. Practicality in calibration

THM80X Series Industry degree high accuracy Temp. & humidity transmitter

STRAIN-GAUGE BRIDGES. Safe Area. Hazardous Area. MTL7755ac. MTL7764ac. MTL7755ac MTL7761ac. MTL7755ac MTL7761ac

B850 Boiler House Energy Monitor

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

FAST SAMPLING CONVERTER

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Power IT LV Active Filters PQFA - PQFL - PQFT

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

General Specifications

MEMOCAL 2000/2000S. Hand-held calibrator

ONE CALIBRATOR ONLY MAIN FEATURES:

Specification DataFile

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

General Specifications

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

with Electronic Assistant

General Specifications

DIGEM f 96 x 48 EK. Applications. Description

High-precision process calibrator Model CED7000

T R X I I TRX-II - 9/98

CALYS 75. Field documenting multifunction calibrator

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

PID Controller-Single Loop (1/16 DIN - Microcontroller Based) (Product Code 10.10)

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

K3P ENG.qxd 23/10/ Pagina 1

HART field temperature transmitter Models TIF50, TIF52, TIF62

( F L O W I Z F A M I L Y )

Rotational speed controller

Connecting Mains Electrical Power

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

CROSS Chassis from 160 A to 450 A

Economical Digital Indicators For Process and Electrical Measurement

Shaft Absolute Vibration Monitor Specifications

MICRO-CONTROLLER X (48 48 mm)

GE Fanuc IC695ALG600. Rx3i PacSystem

INFOCAL 8 Energy calculator

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

Transcription:

S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip programming of input and output functions with full information and data communications for multipoint sensor collecting networks or local control and alarm monitoring. Up to 8 analogue sensors or process signals. Up to 8 frequency or pulse inputs for counting, timing, speed sensing, etc. Up to 16 on/off or digital inputs, thermostats, limit switches, etc. Easy to use menu selection for all information: scale, offset, units and duty. Four programmable output relays with adjustable set points, time delays, hysteresis, relay phase, latching and voting. Simultaneous of all input channels. Individual input signal close-up giving signal, signal tendency, set point parameters and signal bar graph. Data communication and output ports for RS232 or isolated RS485 (Modbus). Data logging facility, for up to 12,500 input readings per channel. Application flexibility, with a choice of mounting formats: DIN rail, Front of panel or 19 rack mounting.

Analogue Inputs Any of the 8 channels can be configured to accept a variety of analogue signal formats and will interface directly with TROLEX sensors and most recognised sensor and process inputs. CURRENT SIGNALS 2 wire or 3 wire process signals. Fully floating differential input allows several units to be connected in series on the same loop with high noise immunity. 0...20mA 4...20mA 0...100mA 5...1000mA VOLTAGE SIGNALS Differential input enables long signal lines with minimal signal loss. 0...2V 0.4...2V 0...10V 8 Input channels for any choice of analogue sensor, process signal or digital input. Each channel function is determined by an interchangeable input module which can be selected for any desired functional combination. Once in place, the module communicates directly with the central microprocessor to automatically format the operating characteristics of each channel. THERMOCOUPLE INPUT Fully linearised input for type K or J thermocouples with cold junction compensation. BS EN 60584 Type J 50 C...200 C 50 C...750 C Type K 50 C...800 C 50 C...1250 C PT100 INPUT Input standard for platinum resistance temperature sensors. DIN43760. BS1904. 50 C...200 C SEMICONDUCTOR INPUT Fully linearised input standard for semiconductor temperature sensors. KTY21-6 50 C...150 C KTY84 0 C...300 C ac INPUT ac input signals from load cells, ac generators, accelerometers and velocity sensors* or power measurement systems. ac Peak: 10Hz...10KHz, 10V pk/pk ac RMS: 10Hz...10KHz, 10V pk/pk *Trolex TX5630 Vibration Sensors BRIDGE INPUT Balanced four arm bridge input. Bridge measuring circuits. Pressure sensors and strain gauges. 0.1...100mV/V. CHANNEL 1 CHANNEL 2 1----- 5----- 2----- 6----- 3----- 7----- 4----- 8----- CHANNEL 3 CHANNEL 4 MICROPROCESSOR 12,500 POINT DATALOG CHANNEL 5 CHANNEL 6 DATA COMMS CHANNEL 7 CHANNEL 8 ALARM STATUS THE DATA MEMORY IS PERMANENT AND ALL SETTINGS ARE RETAINED UNDER POWER FAILURE.

Digital Inputs Any of the 8 channels can be configured to accept pulsing or frequency inputs from NAMUR proximity sensors or switches and each can be individually programmed by the user for seven different pulse processing functions. Input pulses can be prescaled by a selectable factor and the input threshold pulse acceptance level can be programmed to suit a particular application. INPUT SIGNALS VOLTAGE FREE CONTACTS OR PHOTOSENSORS NAMUR SENSORS DIN 19234 FREQUENCY RANGE: 0...10KHz PULSE COUNT INPUT PULSE COUNTING; SINGLE OR CONTINUOUS CYCLING, SEQUENCE COUNTING, UP COUNTING, DOWN COUNTING, BI DIRECTIONAL COUNTING. Batch Counting. Totalising. Rotational Direction Sensing. Rotation Counting. Machine Positioning. Length Measurement. PULSE INTERVAL COMPARES THE INTERVAL BETWEEN TWO CONSECUTIVE PULSES WITH A PROGRAMMED TIME PERIOD: Low Speed Pulse Monitoring. Chain Conveyor Monitoring. Interval Timer when used with a pushbutton or switch. Time Elapsed Indicator. ; ; PULSE FREQUENCY THE RATE OF PULSES OR FREQUENCY IS MEASURED AND COMPARED AS AN ABSOLUTE VALUE: SLIP FREQUENCY THE RATE OF PULSES OR FREQUENCY IS MEASURED AND COMPARED AS A PERCENTAGE SLIP VALUE: Under/Over Speed Monitoring. Frequency Measurement. DIFFERENTIAL FREQUENCY TWO SEPARATE PULSE SOURCES ARE COMPARED AS ABSOLUTE VALUES: DIFFERENTIAL SLIP FREQUENCY TWO SEPARATE PULSE SOURCES ARE COMPARED AS A PERCENTAGE SLIP VALUE: Comparative Speed Sensing. Differential Feed Rate Control. Slip Speed Monitoring. DIGITAL INPUTS Conveyor Monitoring. Flow Rate Monitoring. Differential Frequency Monitoring. SIMPLE ON/OFF INPUTS (DUAL INPUT ON EACH CHANNEL): Switches. Limit Switches. Thermostats. Photocells. Namur Proximity Sensors. Functions as two independent alarm control inputs or as two independent programmable timers. DIGITAL LEVEL INPUT WITH FAILSAFE SIMPLE ON/OFF INPUTS WITH OPEN CIRCUIT/SHORT CIRCUIT SENSOR CONNECTION PROTECTION DUAL INPUT ON EACH CHANNEL: Switches. Limit Switches. Thermostats. Pressure Switches.

JUST FOUR KEYS FOR PROGRAMMING THE SENSOR CONTROLLER NO SPECIAL SOFTWARE, NO COMPUTER KNOWLEDGE, NO DATA ENTRY TERMINALS. Information Display All eight input signals are ed simultaneously on the LCD panel showing the channel number and the signal level in each case. All channels are scanned continuously and the update period of each channel can be varied independently. The TX9044 is packed with an amazingly versatile selection of operating functions all fully programmable. TWO SET POINTS PER CHANNEL. LATCHING, AUTO RESET, PULSE OR BI STABLE RELAY OPERATION. HYSTERESIS OR RELAY DEADBAND SELECTION. Any individual channel can be selected to show close-up data about its input signal. Channel CLOSE-UP LEVEL 1 will show the channel number, the signal value with true engineering units, and the status of the two channel setpoints. Analogue signals will have a bar graph to enable magnitude comparison and will show the periodic rising or falling tendency of the signal. Unique text about the channel can also be entered in the relating to duty or information about the sensor. RELAY PHASE SELECTION- RISING ALARM OR FALLING ALARM. POWER ON DELAY TO OVERRIDE MACHINE RUN UP PERIODS. OUTPUT RELAY TIME DELAY ADJUSTMENT. SELECTABLE INPUT SIGNAL SAMPLING RATE OR UPDATE TIME. INPUT SIGNAL PRE-SCALING. SIGNAL SPAN AND OFFSET ADJUSTMENT. ENGINEERING UNITS MENU FOR TRUE VALUE INDICATION. Channel CLOSE-UP LEVEL 2 will stored information about the previous PEAK and MINIMUM signal values together with the setpoint levels and a time clock/calender. RISING OR FALLING SIGNAL TENDENCY INDICATION. BAR GRAPH SIGNAL DISPLAY. LAST SIGNAL PEAK OR LOW VALUE DATA STORAGE. DISPLAY SPACE TO ENTER SPECIFIC INPUT CHANNEL TEXT.

Data Logging Data logging is also included for recording historical information for up to 12,500 readings. Input Signal Fault Alarm An input signal failure or cable fault will drive the OVERSCALE or UNDERSCALE dependent upon the nature of the fault. This will result in FAULT SIGNAL OUTPUT and a SIGNAL ERROR on the appropriate channel. The operating integrity is also under constant surveillance by a self checking WATCHDOG system which gives a fault signal if a failure should occur. The data shows the channel reference, with its value at the date and time recorded. The data log interval is user selectable. Rapid logging is possible to closely capture critical shutdown routines or a catastrophic plant failure. The information can be periodically reviewed or transferred on demand over the data communication link. Control Functions Each channel has two independent set point signals with an additional common output for system fault indication. Information Security All essential information can be protected by a user security code. This prevents the data from being corrupted by an unauthorised user but still permits selective access to day-to-day functions. There are four independent set point output relays with LED status indicators and any of the channels or the fault signal can be assigned or networked to any of the output relays. This enables alarm status groupings, selective shutdown routines and elementary logic functions to be easily programmed.

Technical Details Dimensions Display Accuracy: Set Point Accuracy: ±0.5%. Ambient Temperature Limits: Electrical Connections: Housing Material: Nett Weight: Environmental Protection: Information Display: Mounting: Microprocessor: ±0.2% (Analogue Channels). 5 C...50 C. 4mm barrier/clamp terminals. ABS. 800gms. IP55 (housing). IP20 (terminals). IP66 (front of panel mounting). LCD. 20 characters x 4 lines 6mm high characters. Din Rail, Front of Panel or 19 Rack. Microprocessor controlled menu operation, with non-volatile data retention. 10 bit A D conversion (Analogue channels) Set Points: 2 per channel plus FAULT signal. Output Relays: 4 (Each with 1 changeover contact). Contact Rating: 8A. 230V ac. Set Point Adjustment: 0...99%. Hysteresis Adjustment: 0...99%. Power on Delay Adjustment: 0...255 seconds for each channel. Output Delay Adjustment: 0...18hrs for each setpoint. Input Update Period 0...60 seconds for each channel. Adjustment: Engineering Units Menu: mv, V, ma, C, F, g, kg, mbar, bar, Pa, kpa, PSI, %, ppm, %RH, mm, m, m/s, mm/s, m 3 /s, ft, ins, ft/sec, rpm, pps, Hz, khz, g/m 3 (SPECIFIC). Fault Signal: Open or Short Circuit signal line or microprocessor WATCHDOG alarm will generate a FAULT signal. The fault will be identified on the. Data Communications: RS232 or RS485. Data Logging: Up to 12,500 readings with on demand down loading. Supply Voltage: 24V dc ±20% @ 125mA. 62 Connections DIN RAIL MOUNTING The output contacts are shown with the relays de-energised in the alarm condition. CHANNEL 5 203 FRONT OF PANEL MOUNTING 74 11 213 ( 1/2 rack) 205 Panel cut-out details All dimensions in mm CHANNEL 6 CHANNEL 7 CHANNEL 8 POWER ON DELAY 0V RESET 0V out 0V out 0V out 0V out A19 A20 A21 A22 A23 A24 A25 A26 A27 A28 A29 A30 A31 A32 A33 A34 A35 A36 RS485 B1 B2 B3 B4 B5 B6 R1 R2 R3 R4 RS232 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 GND RXD TXD 110 128 3U CTS RTS DSR 112 GND RX+ RX TX+ TX +5V A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18-0V out -0V out -0V out -0V out +24V 0V CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 Supply

Plant Wide Monitoring RS232 and RS485 MODBUS data protocol is an available option for integrating multi-point sensor collecting systems. Our systems engineers can design and supply fully integrated data collection networks, including the configuration of PC terminal graphic packages. Housings for Programmable Sensor Controllers Environmentally protected housings for the DIN rail mounting version of the TX9044 Programmable Sensor Controller. X 20.0 100.0 Robust welded sheet steel enclosure. 20.0 Tough corrosion proof coating. 300.0 Sheet steel front cover with polycarbonate viewing window. Environmentally protected to IP66. Ample M20 cable entries. Entry holes Ø22.0 for M20 cable glands Housing X Entry holes TX9204 400mm 10 Mounting rail for TX9044 modules.

S E N S O R S CUSTOMER ORDER/ENQ. REF. CONTACT DATE Order Reference TX9044 PROGRAMMABLE SENSOR CONTROLLER INPUT CHANNEL CONFIGURATION PLEASE YOUR REQUIREMENTS SEMI- CURRENT VOLTAGE TC Type J TC Type K PT100 CONDUCTOR ac DIGITAL DIGITAL LEVEL 0...20mA 4...20mA 0...100mA 5...00mA 0...2V 0.4...2V 0...10V 50 C...200 C 50 C...750 C 50 C...800 C 50 C...1250 C 50 C...200 C 50 C...150 C 0 C...300 C PEAK rms CONTAINS SEVEN FUNCTIONS SELECTABLE DUAL DIGITAL LEVEL WITH FAILSAFE CHANNEL 1 CHANNEL 2 CHANNEL 3 CHANNEL 4 CHANNEL 5 CHANNEL 6 CHANNEL 7 CHANNEL 8 Please specify any specific engineering units required that are not already available in the standard menu list. Please specify additional information: MOUNTING OPTIONS: DIN Rail Mounting (41) 19 Rack Mounting (42) Front of Panel Mounting (43) COMMUNICATION OPTIONS: RS232 Data Communication (51) RS485 Data Communication (52) Accessories TX6611 230V/110V POWER SUPPLY, 1A Output: Capable of powering up to 6 TX9044 Sensor Controllers (not including sensors). DIN Rail or 19 rack mounting. TX9204 HOUSING. Accommodates 1 TX9044 plus 1 TX6611 mains power supply.