UM1380/ UM2380 UM1390/ UM2390 Datasheet

Similar documents
Microscope-Spectrometer

Miniature Spectrometer Technical specifications

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

Symmetrical Czerny-Turner, 75 mm focal length nm nm, depending on configuration (see table)

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

HAMAMATSU PHOTONICS K.K.

University of Wisconsin Chemistry 524 Spectroscopic Components *

ILX pixel CCD Linear Image Sensor (B/W)

Lab Junior Educational UV-VIS Spectrometer

Company synopsis. MSU series

PGS Family Plane Grating Spectrometer from ZEISS

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

NanEye GS NanEye GS Stereo. Camera System

Spark Spectral Sensor Offers Advantages

A-CUBE-Series High Sensitivity APD Detector Modules

OPAL Optical Profiling of the Atmospheric Limb

4-Channel Optical Parallel Transceiver. Using 3-D Polymer Waveguide

AVANTES EVO SERIES THE NEXT EVOLUTIONARY STEP FOR SPECTROMETRY

Laser Speckle Reducer LSR-3000 Series

Technical Explanation for Displacement Sensors and Measurement Sensors

ILX554B pixel CCD Linear Sensor (B/W) for Single 5V Power Supply Bar-code Reader

APPLICATIONS FEATURES GENERAL DESCRIPTIONS. FPA-640x512-KM InGaAs Imager DATASHEET V /10/07. NEAR INFRARED (0.9 µm - 1.

The FTNIR Myths... Misinformation or Truth

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

FPA-320x256-K-2.2-TE2 InGaAs Imager

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

80-MHz Balanced Photoreceivers Model 18X7

Improving the Collection Efficiency of Raman Scattering

True simultaneous ICP-OES for unmatched speed and performance

DV420 SPECTROSCOPY. issue 2 rev 1 page 1 of 5m. associated with LN2

FPA-320x256-C InGaAs Imager

ONE TE C H N O L O G Y PLACE HOMER, NEW YORK TEL: FAX: /

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

MLX90255 Linear Optical Array

80-MHz Balanced Photoreceivers Model 18X7

CMOS Based Compact Spectrometer

SPECTRAL SCANNER. Recycling

BPD-003. Instruction Note

Optical Spectrometer using a Linear CCD image sensor

IT FR R TDI CCD Image Sensor

ILX526A pixel CCD Linear Image Sensor (B/W)

User-configured for Maximum Flexibility

JETI Specbos Instruments

MN39160FH. 4.5 mm (type-1/4) 680k-pixel CCD Area Image Sensor. CCD Area Image Sensor. Features. Applications

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

PB T/R Two-Channel Portable Frequency Domain Terahertz Spectrometer

Contact Image Sensor (CIS) Module

Overview Full Featured Silicon Photomultiplier Module for OEM and Research Applications The is a solid state alternative to the Photomultiplier Tube (

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

sercalo MEMS TUNABLE OPTICAL FILTER

LED Lighting Flux and Color Measurement System (LFC)

ADQ108. Datasheet. Features. Introduction. Applications. Software support. ADQ Development Kit. Ordering information

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

MDS-3 EVALUATION SYSTEM FOR METHANE DETECTION INSTRUCTION MANUAL

First Sensor Evaluation Board Data Sheet Part Description MOD Order #

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER

functional block diagram (each section pin numbers apply to section 1)

A dual-field-of-view spectrometer system for reflectance and fluorescence measurement

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Preliminary TCD2704D. Features. Pin Connections (top view) Maximum Ratings (Note 1)

Photons and solid state detection

SPECIFICATIONS. Tunable Single-Frequency Laser Box. DL-BF12-CLSwwwB-Sxxxx-yy-zz

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

TSL1406R, TSL1406RS LINEAR SENSOR ARRAY WITH HOLD

DR-DG-10-HO. 10 Gbps High Output Voltage Driver Module. Digital Driver. Features. Performance Highlights. Applications Gbps Output Response

TOSHIBA CCD Linear Image Sensor CCD (charge coupled device) TCD2561D

The Condor 1 Foveon. Benefits Less artifacts More color detail Sharper around the edges Light weight solution

Linear X-Ray Photodiode Detector Array with Signal Amplification

GPI INSTRUMENT PAGES

SPECIFICATIONS TO : DUST SENSOR MODULE P/N : DSM501 DSM501 DUST SENSOR MODULE =======================================

specification display & lighting hera spectrometer

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

AvaLight-DHc Full-range Compact Light Source

TCD1711DG TCD1711DG. Features. Pin Connection (top view) Maximum Ratings (Note 1)

Optional AR coating and wedge windows are available

Tunable Lasers. Figure 1, Photo of the Tunable Laser OEM Module, Model: TL-MC040TA101

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Superior ICP-OES optical design for unmatched speed and performance

PML Channel Detector Head for Time-Correlated Single Photon Counting

A dual-field-of-view spectrometer system for reflectance and fluorescence measurement

SiPM Module PRELIMINARY

Axsun OCT Swept Laser and System

HIGH BANDWIDTH DFB LASERS

Maya2000 Pro Spectrometer

operating manual iliad for Windows & Mac OS X software application rc81

Apr - 12, 05. Most recent REV DATE : page #

Mini-spectrometers. 1. Overview. 2. Configuration. Technical Information

Section 1: SPECTRAL PRODUCTS

Commissioning of Thomson Scattering on the Pegasus Toroidal Experiment

UNiiQA+ Color CL CMOS COLOR CAMERA

Pixel. Pixel 3. The LUMENOLOGY Company Texas Advanced Optoelectronic Solutions Inc. 800 Jupiter Road, Suite 205 Plano, TX (972)

VS7550 VUV/UV Mini Spectrograph Operating Manual

LI-V024M-MIPI-IPEX30 Data Sheet

TSL LINEAR SENSOR ARRAY

Transcription:

UM1380/ UM2380 UM1390/ UM2390 Datasheet Description UM1380/ UM2380/ UM1390/ UM2390 spectro-module is a new OtO optical platform with 50% footprint down size compared to UM1280/UM2280 series. Besides the smaller size, the SMA905 is designed as an optional features. The customer can design the optical detector head (like collimator or cosine-corrector) to attach to the UM1380/ UM2380/ UM1390/ UM2390 to save the SMA905 space. UM1390/ UM2390 is designed as the rightangled SMA905 type. There is one micro reflection mirror to change the incident light path. UM1390/ UM2390 provides more flexibility for OEM customer on the product design and integration. UM1380/ UM2380/ UM1390/ UM2390 is built in with the linear CCD type sensor and 8 pin external interface. The optical engine is very simple and optimized for the spectrometer. The optical bench is very rigid and stable for measurement system. The compact size is very flexible for system integration. We provide the related information and the detailed instructions of how to operate with the UM1380/ UM2380/ UM1390/ UM2390 in this guide. The optical detector used in UM1380/ UM2380/ UM1390/ UM2390 spectro-module is a high-sensitivity Toshiba TCD1254 2500-element CCD array sensor. The system integrator can control the CCD sensor directly through the 8 pin external cable. Overview 1.1 Lineup of UM1380/ UM2380/ UM1390/ UM2390 P2 1.2 Output Comparison P2 Main Features 2.1 Feature P3 2.2 Specification P4 Structure 3.1 Mechanical Diagram P6 UM1380/UM2380/UM1390/UM2390 3.2 Electrical Pinout -602 Rev 1 P9 3.3 CCD Overview P12 Internal Operation P15 1

Intensity UM Series Overview 1.1 Lineup of UM1380/ UM2380/ UM1390/ UM2390 Model UM1380- V2 UM1390- V2 UM2380- V2 UM2390- V2 Type Standard SMA905 90 deg. Standard Spectrum response range (nm) 200 300 400 500 600 700 800 900 1000 340nm 850nm Slit Size (um) Resolution (nm) 25 6 40 10 25 6 SMA905 90 deg. 40 10 CCD Type Toshiba TCD 1254 Dark Stray SNR A/D Noise Light 40 10 25 6 200 16 Toshiba 55 0.5% 40 10 TCD 1254 + 25 6 cylindri cal lens UM1380-V2 & UM2380-V2 is the standard type spectrometer module. UM1390-V2 & UM2390-V2 is with right-angled SMA905. 1.2 Output Comparison 1.2 1 0.8 0.6 0.4 0.2 UM2200 UM1200 UM2380 UM2390 UM1380 UM1390 0 380 430 480 530 580 630 680 730 780 Wavelength (nm) Halogen light intensity comparison example. The intensity curve may vary depends on the actual product adjustment. 2

Main Features 2.1 Feature Toshiba TCD1254 Detector High sensitivity detector Readout Rate: 2 MHz Optics Optical resolution: 6 ~10nm (FWHM) slit width: 25 or 40 µm Electrical Performance Integration times: from 1 ms to the time user defined 3

2.2 Specification Absolute Maximum Ratings CCD input power V CC : + 5.25 V DC Physical Specifications Physical dimensions (without SMA905 connector): UM1380/ UM2380: 23.2 mm (W) x 31 mm (D) x 10 mm (H) UM1390/ UM2390: 23.2 mm (W) x 31 mm (D) x 8.5 mm (H) Weight: 13 g Power Power requirement: 5 ma at +5 V DC Supply voltage: 4.5 5.5 V Spectro-module MEMS Optical Structure Input fiber connector: SMA 905 (Optional) Entrance slit: 25 or 40 µm Detector: Toshiba TCD1254 CCD Filters: 2nd & 3rd order rejection 4

Spectroscopic Wavelength range: 340 ~ 850 nm Integration time: 1 ms ~ user defined Resolution (FWHM): 6~10 nm Environmental Conditions Temperature: -30 to +70 Storage & -10 to +50 Operation Humidity: 0% - 90% non-condensing Interfaces CCD direct control 5

Structure 3.1 Mechanical Diagram Fig. 1: UM1380/ UM2380 outer dimensions 6

Fig. 2: UM1390/ UM2390 outer dimensions 7

Fig. 3: UM1380/ UM2380/ UM1390/ UM2390 with Cable outer dimensions 8

3.2 Electrical Pinout The following listed is the pin description for the UM1380/ UM2380/ UM1390/ UM2390 External Connector. The UM1380/ UM2380/ UM1390/ UM2390 module side is 8 pin interface. (pitch 1.0mm) The corresponding connector on board side is HTHR- 08WR. Terminal P1 is assembled inside UM1380/ UM2380/ UM1390/ UM2390. Terminal P2 is linked to the main board. Red Fig. 4: 8 pin Cable Drawing 9

Fig. 5: HTHR-08WR drawing 10

Pin# Description Pin No. Direction Pin Name Function 1 Input SH CCD SH Control 2 Input GainSW CCD Gain Control, the default is low gain (GainSW=0) 3 Analog Output VOUT CCD Video Output 4 GND GND GND 5 Input ROG CCD ROG Control 6 Input CLK CCD CLK Control 7 Power +5V CCD Power +5V 8 GND GND GND Pin orientation Looking at UM1380/ UM2380/ UM1390/ UM2390 8 pin cable, red line is the pin 1 of 8 pin connector. (for main board) Fig. 6: CCD Board and Cable picture 11

3.3 CCD Overview CCD DETECTOR The TCD1254 is a rectangular reduction type CCD linear image sensor designed for optical measuring equipment use. A built-in timing generator and clock-drivers ensure single 5V power supply for easy use. Fig. 7: CCD Block Diagram 12

Fig.8: CCD operation timing waveform This Toshiba CCD only support sample & hold mode. The above timing chart is TCD1254 operation timing. UM1380/ UM2380/ UM1390/ UM2390 CCD board is built-in an inverse Op-AMP circuit to make the output voltage to be proportional to the incident light level. The CCD operation sequence is exposed-transferred-readout. We need to perform the integration time first, then, read the Vout in the next cycle. The operation is like pipeline. The Vout signal shows in the top waveform actually is the exposed result in the previous cycle. The output signal is almost proportion to the integration time. When the light energy or integration time is long enough to fully charge the pixel, the CCD output will be saturated. When the incident light is strong and cause the serious over-saturation condition, the Vout signal may not work correctly and causes some wrong spectrum. 13

CCD/SYSTEM NOISE There are three major sources impact the Vout signal reading. One is the light source stability, the second is the electronics noise, and the other is CCD detector noise. If we don t consider the light source impact, we can check the dark noise performance of this system. The dark noise we define here is the RMS of Vout signal under 1ms integration time in dark condition. So the dark noise will be only contributed by electronics readout noise and the CCD sensor. The other major parameter to define the noise performance is the SNR. The SNR we define here is the ratio of the full signal (65535 counts) to the RMS value under the full signal condition. The higher SNR performance indicates the readout signal is more stable. It will be helpful for the low signal differentiation. SIGNAL AVERAGING Generally, there are two options for the signal curve operations. The first one is the signal averaging. By the averaging method, we can reduce the noise impact on each pixel. Sure, more sampling points will bring the better averaging performance. But it will need more time to get one spectra. When we use the time-base type of signal averaging, the S:N increases by the square root of the number of samples. Thus, a S:N is readily 10x achieved by averaging 100 spectra. The other curve smoothing is boxcar filter. It can average the adjacent points to show the smoother curve. But if the target signal is peak type, the boxcar may not be suitable for this. These two methods can be enabled at the same time if the measurement target is suitable for this operation. 14

Internal Operation Pixel Definition If the system integrator uses the AFE device, you can use the command to manually adjust the baseline. (adjust the AFE OFFSET) The other baseline adjustment method is to enable the background removal. It depends on the user how to use the baseline. The following is a description of all of the pixels Pixel Description 1 16 Dummy pixels 17 29 Optical black pixels 30-32 Dummy pixels 33 2532 Optical active pixels 2533-2546 Dummy pixels 15