Open Type Without Enclosure

Similar documents
Open Type Without Enclosure

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

NEMA Contactor and Starter Specifications

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

1-12. Bulletin 400 Definite Purpose Contactors Approximate Dimensions. 2.1 max Typ max.

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Deploying Current Transformers in Applications Greater Than 200 A

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

Ratings for Switching AC Motors AC-2, AC-3, AC / /

PowerFlex 400 Submittal

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

Bulletin 700-RTC Solid-State Timing Relay

Supplemental Motor Protection Devices Table of Contents

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Starting Torque Controller Technical Data

Bulletin 140U Molded Case Circuit Breakers

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

NEMA Size 1 Cat. No. CN55DN3AB

Bulletin 700-R -RM Sealed Switch Relays

Kinetix 300 Drive (single-phase and three-phase) Power Specifications

Bulletin 1497 Global Control Transformers

1394 External Shunt Resistor Kit

AC Magnetic Starters (GE)

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

Solid-state Contactor Specifications

1204 Reflected Wave Reduction Device

BUCK-BOOST TRANSFORMERS

Modular equipment. Presentation, standards. Standard contactors TeSys GC

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Supplemental Motor Protection Devices Specifications

Characteristics 5 TeSys k contactors and reversing contactors

Bulletin 520 Multi-Speed

Single, dual, and multi-tap primary voltages Single phase EN finger-safe protection RoHS compliant 1497 A M1 3 N

Reduced Voltage Starters

Reduced Voltage Starters

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

AF91 Adjustable Frequency Drives Series B

Supplemental Motor Protection Devices Specifications

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

190S A N D 2 C A16 C TE

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Instruction Bulletin Reduced Voltage Starters Autotransformer Type Class 8606

Controls Contactors and Contactor Assemblies Special Applications

190S A N D 2 C A16 C TE

Series P. Applications

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Kinetix 6000 Integrated Axis Modules

Electronic Circuit Breaker ESS1 for System SVS1

High Frequency Sinewave Guardian TM Filter

(1,5 modules per pole)

ACS600, ACS800. Installation Guide

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

Electronic Circuit Breaker ESS1 for System SVS1

SELECTION GUIDE. BULLETIN 156 Solid-State Contactors

Inverter MICROMASTER 410

Type CP-S, CP-C & CP-A Switch mode

Connection Diagrams. Auxiliary 40 C 60 C 24/48V 120V 240V 400V 500V 600V 690V Contacts Contacts N.O. N.C. Contacts 43 K

PF/PFQ. High Amperage plug and receptacle. Main Advantages

KRPA, KRP, KA, KR series

PowerGard Series C 18-Pulse Enclosed Drive Controllers

DPC F - P3-24. Part Number Scheme. Dimensions

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

High Frequency SineWave Guardian TM Filter

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Bulletin 1497 Global Control Transformers

3 - Protection components Circuit-breakers

Capacitor Switching Contactors

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

US Breaker Brand 3 Pole AC Contactors (Square D Telemecanique LC1 Replacements)

Crane Control Class 7001

+ 24V 3.3K - 1.5M. figure 01

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ZOELLER ENGINEERED PRODUCTS NEMA 4X SIMPLEX & DUPLEX PANELS 1-20 BHP

Transformer Questions & Answers

BLEMO Frequenzumrichter. Siemensstraße 4 D Rodgau Dudenhofen Germany

Ampere Rating LAL MAL* NAL. 2-pole. 3-pole. Catalog No. Price $ QO300 QOU300 QO3000 QOU3000 QOU30001

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

Bulletin 505 Full Voltage Reversing

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Transformer Questions & Answers

Motor Protection Circuit Breaker Series 8146/5-V27

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

SIRIUS/SIKOSTART Soft Starters For Standard Applications

Transcription:

Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General Use Resistive Heating Ballast Lighting (Fluorescent) Discharge Lighting (Mercury Vapor High Pressure Sodium and Metal Halide) Open Type Without Enclosure Type General Purpose Enclosure Type /X Watertight, Corrosion- Resistant Enclosure Stainless Steel Power Poles V AC Maximum Hz Type R// Rainproof, Dusttight Industrial Use Enclosure Cat. No. Cat. No. Cat. No. Cat. No. L-TO L-TA L-AO L-AA L-AC L-AJ L-BO L-BA L-BC L-BJ L-CO L-CA L-CC L-CJ L-DO L-DA L-DC L-DJ L-EO L-EA L-EC L-EJ L-FO L-FA L-FC L-FJ L-GO L-GA L-GC L-GJ L-HO L-HA L-HC L-HJ L-JO L-JA L-KO L-KA General Use Resistive Heating Tungsten Lamp Loads (Max. V Line, V Load) Ballast Lighting (Fluorescent) Discharge Lighting (Mercury Vapor High Pressure Sodium and Metal Halide) Cat. No. Cat. No. Cat. No. Cat. No. Power Poles V AC Maximum Hz L-TO L-TA L-AO L-AA L-AC L-AJ L-BO L-BA L-BC L-BJ L-CO L-CA L-CC L-CJ L-DO L-DA L-DC L-DJ L-EO L-EA L-EC L-EJ L-FO L-FA L-FC L-FJ Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. L-AO becomes Cat. No. L-AOD. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. [V] - - - - - - - - - AC, Hz K S P T N KN I Q M R AC, Hz J D H A F U B C Fiberglass-reinforced polyester hubs are included with each starter. Does not include line and load lugs, see page - for kits. Feed-through wiring only. Only available on sizes. When using V coils on size or, an interposing relay may be required. See coil VA values on page -. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. This coil is optimized for V, Hz applications, but can be used at V, Hz nominal. Special Purpose Bolted Enclosures Hazardous Location Contactor Type & ; Class I, Groups C & D; Class II, Groups E, F & G Type R, & ; Class I, Groups C & D; Class II, Groups E, F & G Size Poles Divisions & Enclosure Code (E) Divisions & Enclosure Code (H) Available Available - www.ab.com/catalogs Preferred availability cat. nos. are bold. Publication A-CAA-EN-P

Bulletin Line Approximate Dimensions NEMA AC Contactors Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Open Type without Enclosure for Bulletin FL, L, and LP and for NEMA sizes, for Bulletin and F Contactors Note: Top mounting hole on Size is / in. (. mm) to the left of centerline on Open Type. Mounting screws: # for sizes, / #, or / # for sizes. NEMA Size /A /A A A A A A Bulletin F-FL Number of Switching Poles Bulletin L-LP -- A Width -/ () -/ (.) -/ () -/ () -/ () -/ () -/ () -/ (.) -/ (.) -/ (.) () -/ (.) -/ (.) () For Feed-Through Wiring this dimension is -/ in. ( mm). For Feed-Through Wiring this dimension is -/ in. ( mm). For Feed-Through Wiring this dimension is -/ in. ( mm). B Height -/ () () -/ () -/ () -/ () -/ () Dimensions in Inches (Millimeters) C Depth D E -/ (.) -/ () -/ () -/ (.) -/ (.) -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () -/ () Approximate Shipping Weight [lb (kg)] (.) (.) -/ (.) -/ (.) (.) -/ (.) -/ (.). (.) (.) () (). (.). () (.) - Publication A-CAA-EN-P

Bulletin Line Mechanical Ratings NEMA Size Mechanical Life (Millions of Operations) Maximum Number of Auxiliary Contacts Operating Time [ms] Pick-up (Average) Drop-out (Average) Construction NEMA Size Wire Size for Power Terminals Required Torque on Power Terminal Wire Clamps and Pressure Connectors or Lugs Type of Power Terminal # AWG lb in Pressure terminals # AWG lb in # AWG lb in Saddle or wire clamps # AWG lb in Pressure terminals # / AWG lb in # / AWG lb in # AWG MCM lb in Lugs sold separately. See page -. Direct bus connections only. Environmental Power Contacts Silver alloy Contact Material Auxiliary Contacts Silver Requirements for Sizing of Wire All wire rated F ( C) or higher must be sized per the local Electrical Code for F ( C) wire. NEMA Size Operating Position Operating Temperature Range Altitude Corrosion-Resistance Horizontal Starters with eutectic alloy Overload relay + F ( + C) Vertical Horizontal Vertical Starters with SMP Overload relay + F ( + C) (provided condensation is prevented) feet before derating All metal parts are treated for corrosion-resistance Publication A-CAA-EN-P -

Bulletin Line Short Circuit Rating Combination contactors and starters with disconnect switch: Bulletin,,, E, F, G, and X NEMA Size Combination Contactors and Starters with Disconnect Switch: Bulletin,,, E, F, G, and X Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] H, K Maximum Voltage [V] H, K J, R L L Combination Lighting Contactors with Disconnect Switch: Bulletin L Available Short Circuit Amperes RMS Lighting Contactor Rating [A] Fuse Type Symmetrical [A] Maximum Voltage [V] H, K H, K J, R Combination Contactors and Starters with Circuit Breaker: Bulletin,,, E, F, G, and X Available Short Circuit Amperes RMS Enclosure Type NEMA Size Symmetrical [A] Maximum Voltage [V], R, R//, /X (stainless) Unilock R,, & Bolted R,, &, R, R//, /X (stainless) Unilock R,, & Unilock R,, & Bolted R,, & R, R// Combination Lighting Contactors with Circuit Breaker: Bulletin L Available Short Circuit Amperes RMS Enclosure Type Lighting Contactor Rating [A] Symmetrical [A] Maximum Voltage [V], R, R//, /X (stainless) Unilock R,, & Bolted R,, &, R, R//, /X (stainless) Unilock R,, & Unilock R,, & Bolted R,, & For the most up-to-date SCCRs, please see the on-line Industrial Controls catalog at www.ab.com/catalogs. - Publication A-CAA-EN-P

Bulletin Line AC Coil Data NEMA Size Operating Volt Amperes Burden [VA] Inrush Hz Coils Sealed Heat Dissipation [W].. & P. ( poles). ( poles). ( poles) ( poles) ( poles). ( poles). (Series L).. (Interposing relay).. Economized DC Coil (Interposing relay).. Economized DC Coil (Interposing relay).. Economized DC Coil (Interposing relay). Coil Operating Limits % This rating is for the size contactor coil only. All starters are shipped with an interposing relay as standard. Size starters are shipped with a VA control circuit transformer and an interposing relay with a V coil. Voltage is then rectified to DC for the contactor coil. Size starters are shipped with a VA control circuit transformer and an interposing relay with a V coil. Voltage is then rectified to DC for the contactor coil. Size starters are shipped with a VA control circuit transformer and an interposing relay with a V coil. Voltage is then rectified to DC for the contactor coil. Auxiliary Contacts (NEMA A and P) Bulletin, AC Rating Designation A Maximum AC Contact Rating Per Pole [A] Continuous [VA] Maximum Voltage Carrying Current or Hz Make Break [A] Make Break.. Maximum DC Contact Rating Per Pole for, Auxiliary Contacts (Maximum Continuous Carrying Current is A) DC Rating Designation V DC V DC V DC P. A. A (Requires Contacts in Series). A (Requires Contacts in Series) Publication A-CAA-EN-P -

Bulletin Line Load-Life Curves Bulletin Line contactors and starters are designed to provide superior performance in a variety of applications. These load-life curves are based on Rockwell Automation tests according to the requirements defined in IEC -. Actual contact life may vary based on the application, duty cycle, and environmental conditions from that indicated by the curves. To find the contactor s estimated electrical life, follow these guidelines: Choose the appropriate graph that most closely approximates the utilization category of the application. Locate the intersection of the life-load curve of the appropriate contactor with the application s operational current (I e ) found on the horizontal axis. Read the estimated contact life in millions of operations along the vertical axis. Contact Life for Mixed Utilization Categories AC and AC In many applications, the utilization category cannot be defined as either purely AC or AC. In those applications, the electrical life of the contactor can be estimated from the following equation: L = mixed L AC L AC AC + P ( ) L AC Where: L mixed = Approximate contact life for a mixed AC/AC utilization category application L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) L AC = Approximate contact life in operations for AC utilization category (from AC life-load curves below) P AC = Percentage of AC operations Utilization Categories CategoryTypical Duty ACStarting of squirrel cage motors and switching off only after the motor is up to speed. ACStarting of squirrel cage motors with inching and plugging duty. Bulletin Load/ Life Curves AC and AC M M M M M NEMA SIZE AC NEMA SIZE M M M M M AC M OPERATING CYCLES M K K K K OPERATING CYCLES K K K K K K K K K K K K K K K K OPERATIONAL CURRENT le (APMERES) OPERATIONAL CURRENT le (APMERES) - Publication A-CAA-EN-P

Bulletin Line Group Motor Ratings for NEMA Contactors/Starters Manual Starters FLA Range (Amps) Group Rating (V) Contactors w/o Limiter with Limiter Size Size Size Size Size -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -BO -CO -MN+- P -MN+- P.. ka -CO -DO.. ka -CO -DO Group Rating (V) Starters FLA Range Manual Starters (Amps) w/o Limiter with Limiter Size Size Size Size Size -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -TO -AO -BO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -AO -BO -CO -MN-.. ka ka -BO -CO -MN+- P.. ka -CO -DO -MN+- P.. ka -CO -DO Cat. No. is incomplete. Refer to page -. Cat. No. is incomplete. Refer to page -. Publication A-CAA-EN-P -

Bulletin Line Full Load Currents of -Phase, Hertz AC Induction Motors The full load currents listed below are average values for horsepower rated motors of several manufacturers at the more common rated voltages and speeds. These average values, along with the similar values listed in the U. S. National Electrical Code (NEC), should be used only as a guide for selecting suitable components for the Motor Branch Circuit. The rated full load current, shown on the motor nameplate, may vary considerably from the listed value depending on the specific motor design. ATTENTION: The motor nameplate full load current should always be used in determining the rating of the devices used for Motor Running Overcurrent Protection. HP / / / / -/ -/ RPM Full Load Current [A] V V V V V V........................................................................................................................................................................................... Synchronous speed nameplate is usually less due to slip..................................... HP RPM Full Load Current [A] V V V V V V..................................................................................................................... - Publication A-CAA-EN-P