P1\C-CL \D PETERSEN ALUMINUM CORPORATION FL23953 METAL ROOFING CATEGORY INSTALLATION DETAIL BINDER TABLE OF CONTENTS:

Similar documents
UL Construction No. 254

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Ekoroof LiteTile Dimensions

UNA-CLAD Metal Roof Systems

Inspire Aledora Slate Application Guidelines

TABLE OF CONTENTS A-1

SLATE & SHINGLE INSTALLATION

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

Table of Contents Light Gauge Metal Roof & Wall Panels

eco-shake INSTALLATION INSTRUCTION

ICC-ES Evaluation Report Reissued September 1, 2012 This report is subject to renewal September 1, 2013.

FLORIDA PRODUCT APPROVAL 5VCRIMP FLORIDA PRODUCT APPROVAL NO R2. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

DW HORIZONTAL INSTALLATION

METRO PANELS (EXPOSED


FLORIDA PRODUCT APPROVAL GULFRIBTM FLORIDA PRODUCT APPROVAL NO R3. Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC.

Tuff-Rib Install Guide

REGAL. Installation Manual

ROOFING APPLICATION STANDARD (RAS) No. 130 INSTALLATION CRITERIA FOR WOOD SHINGLES AND SHAKES APPLICATION

ROOFING APPLICATION STANDARD (RAS) No. 130

Turada Hardwood Shingles and Shakes Installation instructions

Asphalt Shingle Installation at Roof Edges, Intersections and Valleys

WESTERN WAVE Panel. Vertical Installation and Technical Information

WESTERN WAVE Panel. Horizontal Installation and Technical Information

900 SERIES WALL PANELS

BARRELL VAULT BATTENLESS

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

MAXIMUM PANEL ATTACHMENT FASTENER SPACING IS 24" O.C. ALL FASTENERS TO PENETRATE WOOD 3/4" MIN. AND METAL FRAMING 1/2" MIN.

400 SERIES VERTICAL INSTALLATION

Metal Roof Installation Manual. Chapter 14: Fasteners

PROJECT INSTRUCTIONS Roofing

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

ATOMIC. ASM Panel Brochure ARCHITECTURAL SHEET METAL,

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

KS SERIES - VERTICAL INSTALLATION

RED DIAMOND SHINGLES Roof Installation Introduction:

CertainTeed. Shake / Slate Installation Guide

KS42 MF SERIES - HORIZONTAL INSTALLATION

GLOSSARY OF TERMS SECTION 8

SECTION SHEET METAL FLASHING AND TRIM

900 SERIES PANEL SHEET INDEX STAGGERED ENDLAP STAGGERED MALE LEG AT ENDLAP CONTINUOUS FEMALE ENDLAP INSTALLATION SEQUENCE CI-WR

TABLE OF CONTENTS A. PBR

CBUCK Engineering. for. Florida Product Approval # FL R1

METAL ROOFING INSTALLATION GUIDE

ROOFING City of Grand Rapids Building Safety Division

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

REPORT HOLDER: ISAIAH INDUSTRIES, INC. EVALUATION SUBJECT:

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

b) Symphony comes pre-packaged in color and width blends. There is no need to mix Symphony at the job site. Currently Symphony is available in the

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SHEET METAL FLASHING AND TRIM Christ on the Mountain

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Brava Old World Slate Installation Guide

Installation Instructions

ONDUVILLA. The Attractive Alternative to Shingles I N S T A L L A T I O N I N S T R U C T I O N S

Barrel Vault Counter Batten and Batten

Installation Guidelines

Metal Roof Installation Manual. Chapter 5: Panel Attributes/Profiles

4. Metal roof jacks at penetrations and attachments

INSTALLATION DETAILS

Five Star Panel Installation Instructions

Installation Instructions

installation guide Villa

EVALUATION REPORT GAF Materials Corporation 1361 Alps Road, Building 7-3 Wayne, NJ 07470

Finesse Profiles. Nailstrip

DECRA Shingle Installation Guidelines

INSTALLATION WARNING! These install details are provided to demonstrate a recommended installation method for Metro Roof panels and accessories.

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

PROVEN DEPENDABLE SUSTAINABLE

TIOGA Table of Contents

DETAIL MANUAL for Standing Seam / Image II

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

Storing, Handling, and Cutting Steel Panels

SECTION SHEET METAL FLASHING AND TRIM

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

PRODUCT EVALUATION Effective July 1, 2009 RC-204

DMI FR1511 PANEL (JC) - J CLOSURE DMI WALL PANEL SOFFIT TO WALL PANEL PROVEN DEPENDABLE SUSTAINABLE METAL ENVELOPE SYSTEMS SINCE 1988

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

2 ½ Corrugated Panel Installation Specifications

Metal Roof Installation Manual. Chapter 2: Metal Roofing: A Family of Products / History of Metal Roofing

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

Multi-Width Slate. Single-Width Valoré Slate Widths: 12"

Perimeter/Roof Edge Systems 800-PAC-CLAD PAC-CLAD.COM

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

Roof Attachment Overview

PRODUCT DESCRIPTION. This evaluation report includes aluminum clad wood skylights based on the following tested configurations:

FASTENERS BUILDING DEPARTMENT

Slate Shingle Specifications

Installation Manual. For Gerard Shingle Products

Table of Contents. Important Notices 3. Residential Roofing Application 4. Trims & Accessories 5. Trim Glossary 6, 7, 8. Estimating Material 9

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

Multi-Width Shake. Widths: 9", 8", 7", 6", 4" Length: 22" Thickness at butt: 5/8" Single-Width Shake. Widths: 9" Length: 22" Thickness at butt: 5/8"

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

Transcription:

p P1\C-CL \D P E T E R S E N PETERSEN ALUMINUM CORPORATION FL23953 METAL ROOFING CATEGORY INSTALLATION DETAIL BINDER TABLE OF CONTENTS: Snap-On Standing Seam Panel 24GA Steel &.032" Aluminum... 2-3 Snap-Clad Panel 16oz/sf Copper... 4-6 Tite-Loc Plus:.040" Aluminum x 12" &.040" Aluminum x 16"... 7-14 M-36 Panel (36"wide): 24GA Steel &.032" Aluminum...15-16 R-36 Panel (36" wide): 22GA, 24GA,.032" &.040" Aluminum... 17-18 7.2" Rib Panel: 24GA & 0.032" Aluminum... 19-21 2.67" x 7 /8" Corrugated Panel: 24GA &.032" Aluminum...22-24 Tite-Loc Plus: 12" x.040 Aluminum over 22GA Steel Deck.... 25-26 Tite-Loc Plus: 12" x 22GA Steel over 22GA Steel Deck.... 27-28 Tite-Loc Plus: 18" x 24GA Steel over 22GA Steel Deck.... 29-30 Tite-Loc Plus: 16" x.032" Aluminum over 15/32"Pl yw ood...31-32 Edge-Loe 1.0:.032" Aluminum... 33-37 Large Precision Tile: 14.5" x.032" Aluminum... 38-40 Large Precision Tile: 14.5" x 24GA... 38-40 Precision Diamond Tile: 7.25" x.032" Aluminum...41-43 41-43 Locke Bowden, P.E. FL Reg. #49704 Page 1 of 43

FL 23953 Snap-On Standing Seam Panel 24GA Steel &.032" Alum Page 2 of 43

(FORMERLY 6191) Page 3 of 43

FL 29353 Snap-Clad Panel 16oz/sf Copper Page 4 of 43

SNAP-CLAD - PLYWOOD DECK GABLE DETAIL (FORMERLY FL 8310) Job Name Contractor Date Notes PETERSEN ALUMINUM CORPORATION PAC-CLAD.COM SALES@PETERSENMAIL.COM Petersen Headquarters 1005 Tonne Road Elk Grove Village, IL 60007 P 800 PAC CLAD F 800 722 7150 Annapolis Junction 9060 Junction Drive Annapolis Junction, MD 20701 P 800 344 1400 F 301 953 7627 Tyler 10551 PAC Road Tyler, TX 75707 P 800 441 8661 F 903 581 8592 Acworth 102 Northpoint Pkwy Acworth, GA 30102 P 800 272 4482 F 770 420 2533 Andover 1885 Station Pkwy NW, Ste B Andover, MN 55304 P 877 571 2025 F 866 901 2935 Page 5 of 43

SNAP-CLAD - PLYWOOD DECK EAVE DETAIL 1 (FORMERLY FL 8310) Job Name Contractor Date Notes PETERSEN ALUMINUM CORPORATION PAC-CLAD.COM SALES@PETERSENMAIL.COM Petersen Headquarters 1005 Tonne Road Elk Grove Village, IL 60007 P 800 PAC CLAD F 800 722 7150 Annapolis Junction 9060 Junction Drive Annapolis Junction, MD 20701 P 800 344 1400 F 301 953 7627 Tyler 10551 PAC Road Tyler, TX 75707 P 800 441 8661 F 903 581 8592 Acworth 102 Northpoint Pkwy Acworth, GA 30102 P 800 272 4482 F 770 420 2533 Andover 1885 Station Pkwy NW, Ste B Andover, MN 55304 P 877 571 2025 F 866 901 2935 Page 6 of 43

FL 23953 Tite-Loc Plus:.040" Aluminum x 12".040" Aluminum x 16" Page 7 of 43

PETERSEN ALUMINUM CORPORATION 4175 ROYAL DRIVE; SUITE 300 KENNESAW, GA 30144 PHONE: 800-272-4482 FAX: 770-420-2533 email: wmorris@petersenmail.com PAC-CLAD STANDARD DETAILS (FORMERLY FL 10879) APPROVAL TITE-LOC PLUS EAVE CUSTOMER: GUAGE: JOB NAME: ANGLE / SLOPE: PANEL TYPE: PO#: COLOR / FINISH: DATE: Page 8 of 43

PETERSEN ALUMINUM CORPORATION 4175 ROYAL DRIVE; SUITE 300 KENNESAW, GA 30144 PHONE: 800-272-4482 FAX: 770-420-2533 email: wmorris@petersenmail.com PAC-CLAD STANDARD DETAILS (FORMERLY FL 10879) APPROVAL TITE-LOC PLUS VENTED RIDGE CUSTOMER: GUAGE: JOB NAME: ANGLE / SLOPE: PANEL TYPE: PO#: COLOR / FINISH: DATE: Page 9 of 43

PETERSEN ALUMINUM CORPORATION 4175 ROYAL DRIVE; SUITE 300 KENNESAW, GA 30144 PHONE: 800-272-4482 FAX: 770-420-2533 email: wmorris@petersenmail.com PAC-CLAD STANDARD DETAILS (FORMERLY FL 10879) APPROVAL TITE-LOC PLUS GABLE CUSTOMER: GUAGE: JOB NAME: ANGLE / SLOPE: PANEL TYPE: PO#: COLOR / FINISH: DATE: Page 10 of 43

PETERSEN ALUMINUM CORPORATION 4175 ROY AL DRIVE; SUITE 300 KENNESAW, GA 30144 PHONE: 800-272-4482 FAX: 770-420-2533 email: wrnorris@petersenmail.com PAC-CLAD STANDARD DETAILS (FORMERLY FL 10879) METAL VALLEY ITH 1-3/4' MIN, DIVERTE TITE-LDC PLUS PANEL (' HIN, TITE-LDC PLUS LO FLDA TING AR CLIPS / (2) FASTENERS PER CLIP /8' PLY DDD DECK BY OTHERS FIELD NOTCH FORM HEM AT END OF PANEL HOOK HEM ONTO CLEAT SET IN SEALANT DNTINUDUS CLEAT SET IN CONTINUOUS BEAD OF SEALANT FASTEN l!i! 3' DC MAX. TITE-LOC PLUS VALLEY TAS 100 WIND DRIVEN RAIN TEST APPROVAL CUSTOMER: JOB NAME: PANEL TYPE: COLOR/ FINISH: GUAGE: ANGLE / SLOPE: PO#: DATE: Page 11 of 43

PETERSEN ALUMINUM CORPORATION 4175 ROYAL DRIVE; SUITE 300 KENNESAW, GA 30144 PHONE: 800-272-4482 FAX: 770-420-2533 email: wmorris@petersenmail.com PAC-CLAD STANDARD DETAILS APPROVAL CUSTOMER: TITE-LOC PLUS CLIP GUAGE: JOB NAME: ANGLE / SLOPE: PANEL TYPE: PO#: COLOR / FINISH: DATE: Page 12 of 43

SEAMING INSTRUCTIONS AND PANEL INSTALLATION 1. Install panels on the roof, and with TITE LOC PLUS, ensure the panels are laid so that seamer can be used properly to run downslope. Note that the TLP seamer is one direction only, and will not run upslope on roofs with a 4:12 pitch or higher. TITE LOC seamers are bidirectional and can run up and down slope. IMPORTANT NOTE: STAND AT THE EAVE AND LOOK UPSLOPE. IF THE ROOF IS INSTALLED LEFT TO RIGHT, THE SEAMER WILL RUN DOWNSLOPE. (FORMERLY FL 10879) RIDGE EAVE Page 13 of 43

TITE-LOC PLUS (FORMERLY FL 10879) PANEL HEM PROCEDURE CUT FEMALE END BACK 1 1/4" 1. PANELS REQUIRING FIELD HEMMED ENDS SHOULD BE FABRICATED 1 1/4" LONGER THAN THE FINISHED PANEL LENGTH. VALLEY CONDITIONS MUST BE FIELD CUT TO THE APPROPRIATE ANGLE 2. CUT BACK PANEL JOINTS 1 1/4" CUT MALE END BACK 1 1/4" 3. PLACE PROTRUDING PAN INTO THE PANEL HEMMING TOOL. THE FRONT EDGE OF THE TOOL MUST REST AGAINST THE NOTCHED JOINT LEGS ON BOTH SIDES. 4. WHILE MAINTAINING PRESSURE AGAINST THE PANEL JOINTS, ROTATE THE HEMMING TOOL AS CLOSE TO 180" AS POSSIBLE. PANEL HEMMING TOOL 5. INSPECT COMPLETED HEM TO INSURE THAT THE HEM IS OPENED AND CAPABLE OF RECEIVING THE CLEAT (SEE ERECTION DETAILS). Page 14 of 43

FL 29353 M-36 Panel (36" wide) 24GA Steel &.032" Aluminum Page 15 of 43

(FORMERLY FL 10880) Page 16 of 43

FL 23953 R--36 Panel (36" wide) 22GA & 24GA Steel.032" &.040" Aluminum Page 17 of 43

(FORMERLY FL 10880) Page 18 of 43

FL 23953 7.2" Rib Panel 24GA Steel &.032" Aluminum Page 19 of 43

(FORMERLY FL 11680) Page 20 of 43

(FORMERLY FL 11680) Page 21 of 43

FL 29353 2.67" X 7/8" Corrugated Panel 24GA &.032" Aluminum Page 22 of 43

(FORMERLY FL 12311) 2.67" X 7/8" CORRUGATED APPLICATION PREVAILING WIND NOTE: 1. Panels should always be lapped against prevailing winds. 2. The above fastening patterns are typical and may not be appropriate for all applications. Consult a Professional Engineer for specific requirements. 1 3. 8" x 1 2" tape sealant shall be used at all side laps when used as a roof panel. 4. Side lap fasteners are required. Typical spacing is 18", however this spacing may not be appropriate for all applications. Consult a Professional Engineer for specific requirements. 5. When using this panel in a roofing application, it should be lapped two corrugations. Panel may be lapped one corrugation when used in a siding application. 6. DO NOT USE NAILS FOR ANY PANEL ATTACHMENT. Petersen Aluminum Corporation 4175 Royal Drive, Building 300 Kennesaw, GA 30144 tel: 800-272-4482 fax: 770-420-2533 visit us on the web @ www.pac-clad.com Page 23 of 43

A-POINT SCREWS STANDARD PAC-CLAD SCREWS SELF DRILLING SCREWS A thread forming screw used for light gage metal. Use A-point screws to attach panels to wood. Pre-drilling holes in the panels may be required depending on the metal thickness. Use non-corrosive stainless steel A-point screws to attach aluminum panels to cold-formed steel structural members. Stainless steel, self-drilling screws are not recommended because they must be made from a stainless steel which may corrode. A-point screws may be used to attach panels to light gage metal framing, however pre-drilling may be required. ALL FASTENERS MUST BE ZINC PLATED OR NON-CORROSIVE STAINLESS STEEL. MILL POINT SCREWS A sharp pointed screw with a small drill tip designed to cut through thin sheet metal. Use Mill point screws for panel to panel and panel to flashing attachments. Total drilling thickness is 3 32" A Thread cutting screw designed to cut & thread light gage metal framing without pre-drilling. Maximum drill thickness is 16". 3 Use Self Drilling Screws to attach panels to light gage steel framing. ALL FASTENERS MUST BE ZINC PLATED OR NON-CORROSIVE STAINLESS STEEL. B-POINT SCREWS A thread forming screw used for heavy gage metal. Use to attach panels to structural steel members. Pre-drilling holes will be required. Also use B-point screws rather than self drilling stainless steel screws to attach aluminum panels to light gage steel. Stainless steel used in self drilling screws may cause corrosion in aluminum panels. ALL FASTENERS MUST BE ZINC PLATED OR NON-CORROSIVE STAINLESS STEEL. FASTENER TYPES FASTENER TYPE FASTENER DESCRIPTION LENGTH HEAD SIZE A #12 MAXX SELF DRILL W/ WASHER 1-1/4" 5 16 " B #9 OR 10 PANEL TITE SELF DRILL W/ WASHER 1"TO 3" (BY 1 2") C #12-14 PANEL TITE STITCH LAP W/ WASHER 7 8 " 1 4" 1 4" D 1 4 "-14 PANEL SCREWS W/ WASHER VARIES 3 8 " * FASTENER LENGTHS DO NOT INCLUDE ANY INSULATION THICKNESS BENEATH METAL PANEL APPLICATION TABLE PAC PANEL DECK FASTENER FROM ABOVE ALUMINUM WOOD B - IN STAINLESS STEEL STEEL WOOD B - IN ZINC PLATED ALUMINUM STEEL DECK, LIGHT GAGE FRAMING A - IN STAINLESS STEEL STEEL STEEL DECK, LIGHT GAGE FRAMING A - IN ZINC PLATED ALUMINUM STRUCTURAL STEEL D - STAINLESS STEEL STEEL STRUCTURAL STEEL D - IN ZINC PLATED ALUMINUM PANEL TO ALUMINUM PANEL & FLASHINGS C - IN STAINLESS STEEL STEEL PANEL TO STEEL PANEL & FLASHINGS C - IN ZINC PLATED NOTES: 1. For 1 2" and 7 8" Corrugated panels, place a screw no more than one corrugation away from the side-lap. This may result in an odd screw spacing adjacent to the side-lap. Between side-laps, use the fastening schedules shown. 2. Side-laps should be fastened at 18" O.C. except for R-36 panels which should be fastened 12" O.C. 3. Painted screws are available to color-match painted panels. (1000 piece minimum order) 4. The use of nails for fastening these panels is not permitted. 5. All exposed screws should have a combination metal and neoprene washer. Petersen Aluminum Corporation 4175 Royal Drive, Building 300 Kennesaw, GA 30144 tel: 800-272-4482 fax: 770-420-2533 visit us on the web @ www.pac-clad.com Page 24 of 43

FL 23953 Tite-Loc Plus 12" x.040" Aluminum over 22GA Steel Deck Page 25 of 43

(FORMERLY FL 13487) Page 26 of 43

FL 23953 Tite-Loc Plus 12" x 22GA Steel over 22GA Steel Deck Page 27 of 43

(FORMERLY FL 13487) ROOF PANEL (REF. NOTES & PANEL DETAIL) SELF ADHERED MEMBRANE CLIP SPACING AS PER ALLOWABLE PRESSURE TABLE BEARING PLATE ------- 12" -------, / -..._ SEE DETAIL 1 / y. _,,,- THIS SHEET DRAWN BY: e.s. PLOT: DECK SUPPORTS NOT SHOWN CLIP FASTENER (2 PER CLIP) DECK MIN 22 GA. TYPICAL PANEL INSTALLATION X-SECTION <D 0 CLIP PANEL CLIP BEARING PLATE PANEL SELF ADHERED MEMBRANE BEARING PLATE,----- ----7 J L I r, r, I I \; \; I I I SELF ADHERED MEMBRANE RIGID INSULATION \_DECK MAX 4" THICK MIN 22 GA. RIGID INSULATION MAX 4" THICK CLIP FASTENER (2 PER CLIP) CLIP SECTION VIEW DETAIL 1 CLIP SIDE VIEW CLIP FASTENER (2 PER CLIP) DECK MIN 22 GA. -f 0.675" 0.30 ::/!4 " f [ L] 11.975" PANEL SECTION (MIN. 22 GA.) GENERAL NOTES 1. ARCHITECTURAL STANDING SEAM ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN 22 GA. (0.028"). MAXIMUM COVERING WIDTH OF PANEL = 12". 3. THE ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. CLIPS AND FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. DECK AND SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. Page 28 of 43

FL 23953 Tite-Loc Plus 18" x 24GA Steel over 22GA Steel Deck Page 29 of 43

(FORMERLY FL 13487) ROOF PANEL (REF. NOTES & PANEL DETAIL) SELF ADHERED MEMBRANE CLIP SPACING AS PER ALLOWABLE PRESSURE TABLE BEARING PLATE f----------- MAX. 1 8" --------- / -..._ SEE DETAIL 1 / y. _,,,- THIS SHEET DRAWN BY: e.s. PLOT: DECK SUPPORTS NOT SHOWN CLIP FASTENER (2 PER CLIP) DECK MIN 22 GA. TYPICAL PANEL INSTALLATION X-SECTION <D 0 CLIP PANEL CLIP BEARING PLATE PANEL SELF ADHERED MEMBRANE BEARING PLATE,----- ----7 J L I r, r, I I \; \; I I I SELF ADHERED MEMBRANE RIGID INSULATION MAX 4" THICK \_DECK MIN 22 GA. RIGID INSULATION MAX 4" THICK CLIP FASTENER (2 PER CLIP) CLIP SECTION VIEW CLIP SIDE VIEW CLIP FASTENER (2 PER CLIP) DECK MIN 22 GA. DETAIL 1 f [_..,l MAX. 17.975", MIN. 11.975",l PANEL SECTION (MIN 24 GA.) o. 0r GENERAL NOTES 1. ARCHITECTURAL STANDING SEAM ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN 24 GA. (0.021 "). MAXIMUM COVERING WIDTH OF PANEL = 18", MINIMUM 12". 3. THE ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. CLIPS AND FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. DECK AND SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. Page 30 of 43

FL 23953 Tite-Loc Plus 16" x.032" Aluminum over 15/32" Plywood Page 31 of 43

(FORMERLY FL 13487) ROOF PANEL (REF. NOTES & PANEL DETAIL) CLIP SPACING AS PER ALLOWABLE PRESSURE TABLE f--------- MAX. 16" -------..- I,... SEE DETAIL 1 / 'v THIS SHEET DRAWN BY: e.s. PLOT: MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S GUIDELINES MINIMUM ATTACHMENT: 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS SPACED @ 6" O.C. IN FIELD & EDGES PLYWOOD 19/32" THICK (MIN.) TYPICAL PANEL INSTALLATION X-SECTION <D 0 CLIP PANEL CLIP,----- ----7 J L I r, r, I I \; '; I I I CLIP FASTENER (2 PER CLIP) CLIP SECTION VIEW PLYWOOD 19/32" THICK (MIN.) CLIP FASTENER (2 PER CLIP) CLIP SIDE VIEW PLYWOOD 19/32" THICK (MIN.). N l'l 0 ci w 0 DETAIL 1.<O r c --- J MAX. 15.975", MIN. 11.975",l PANEL SECTION (NOM. 0.032" THICK ALUMINUM) GENERAL NOTES 1. ARCHITECTURAL STANDING SEAM ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE NOM. 0.032" THICK ALUMINUM. MAXIMUM COVERING WIDTH OF PANEL = 16", MINIMUM 12". 3. THE ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. CLIPS AND FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. DECK AND SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. Page 32 of 43

FL 23953 Edge-Loc 1.0.032" Aluminum Page 33 of 43

(FORMERLY FL 17810) Page 34 of 43

(FORMER FL 17810) Page 35 of 43

0.032" ALUMINUM PANELS 20" COIL WIDTH 16" COVERAGE ON 1 /2" PLYWOOD 120" (FORMER FL 17810) #10 x 1-1/2" PANCAKE HEAD SCREWS 12" FROM ENDS AND 16" ON CENTER I FIELD / / SPECIMEN TYP. 0.032" ALUMINUM PANEL PANEL SEAM \l ':_':_: ':_':_':_':_ ':':_':_ s,;d.-..._ VERSASHIELD HT PRO QUIK-STICK 30# FELT PAPER /;; E iii r') Iii., I! :i; l I ;::.- Q "', 5a o.==. /? - 0 o z o <> Q &: g 0.. e; 0 I, own " "'-,. 0 - "' Cl ::,W a ::,zw.;! z...j w w < > 6 Vlc 0 f,: NO w.,, 1J?tiC!'.o co.. 0.- / / 1/2" PLYWOOD SHEATHING Q i j PERIMETER PANEL FASTENERS #10 X 1-1/2" PANCAKE HEAD SCREWS AT 3" O.C. PANEL ELEVATION FIELD SPECIMEN N.T.S. I I I / / PAN - / / END DETAIL \ /I TYP. N.T.S. #10 X 1-1/2" PANCAKE HEAD SCREW 3" FROM EACH PANEL END ONLY 0.032" ALUMINUM PANEL VERSASHIELD HT PRO QUIK-SllCK 30# FELT PAPER 1 /2" PLYWOOD SHEATHING i@mii.,:, ITmmi E, "" 1,oBetterTogether. Tcsl.;ample.:ompl1es,,nth 1hess: (kt7itl O.:vml1011:, me noted Reporl /1 El977.0l-450-18 Date 03/10/2015 V cnfictl Alan Rule Cl - u z 0 0...J D:'. w (!) 0 C, 0.. w 0 :::; u :::i :::; :ii z :::i...j :ii :::i...j ' <( N "' z 0 w IJ I ti i D:'. w! g q I" I" Ol w Page 36 of 43

(FORMER FL 17810) 0.032" ALUMINUM PANELS 20" COIL WIDTH 16" COVERAGE ON 1 /2" PLYWOOD 120" 1/10 >< 1-1/2" PANCAKE HEAD SCREWS 6" FROM ENDS AND 6" ON CENTER PANEL SEAM CORNER / I / SPFCIMEN VERSASH1ELD HT PRO QUIK-STICK 301/ FELT PAPER :,; Iii ; "1' "1' z ii! u "' 1 1 w,! z Q Qoo.:o ls 8! 1\ a. uwc-; "'' Bs 8 -- 3zw <t :it, z3.;! w <!s: <.,(/) 0 ii "' "' I u CLO _J w z / / TYP. CORNER INSTALLATION 1 /2" PL YWOOO SHEATHING N.T.S. z r i <( _J _J PERIMETER PANEL FASTENERS #10 X 1-1/2" PANCAKE HEAD SCREWS AT 3" O.C. COVERAGE PANEL ELEVATION CORNER SPECIMEN N.T.S. I I / / / \ /i TYP. / PANEL END DETAIL N.T.S. #10 X 1-1/2" PANCAKE HEAD SCREW 3" FROM EACH PANEL END ONLY 0.032" ALUMINUM PANEL VERSASHIELD HT PRO QUIK-STlCK 301/ FELT PAPER 1 /2" PLYWOOD SHEATHING i@mii M:,n.n,01, 1 i:: :.c'c_1bettertogether. Test sample i.:omrtlh:s v,1th th,.;se Jdails Di.:vrnt1ons m c noted Rcrort 11 E1977.01-450-18 Date 03/10/2015 Ven lied flv Alan Rule q 0 z 0 9 I w 0:: 0 CL w ::i. 0 :::, ::i. z :::, _J :i _J. z 0 w CL " g 0 rs-. rs-. n. er, w Page 37 of 43

FL 23953 Large Precision Tile 14.5" x.032" Aluminum 14.5" x 24GA Steel Page 38 of 43

(FORMERLY FL 22548) GA. AVAILABLE: 24 GA. STEEL.032 ALUMINUM MATERIALS: STEEL ALUMINUM SIZES AVAILABLE: 8 3/8" x 14 1/2" FINISH: PAC-CLAD PVDF WEBSITE: WWW.PAC-CLAD.COM HQ: 1005 Tonne Road Elk Grove Village, IL 60007 P: 800-PAC-CLAD F: 800-722-7150 9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627 10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592 102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533 SALES OFFICE 1885 Station Parkway NW Suite B P: Page 877-571-2025 39 of 43 F: 866-901-2935 PG. 1

(FORMERLY FL 22548) GA. AVAILABLE: 24 GA. STEEL.032 ALUMINUM MATERIALS: STEEL ALUMINUM SIZES AVAILABLE: 8 3/8" x 14 1/2" FINISH: PAC-CLAD PVDF WEBSITE: WWW.PAC-CLAD.COM HQ: 1005 Tonne Road Elk Grove Village, IL 60007 P: 800-PAC-CLAD F: 800-722-7150 9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627 10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592 102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533 SALES OFFICE 1885 Station Parkway NW Suite B P: Page 877-571-2025 40 of 43 F: 866-901-2935 PG. 2

FL 23953 Precision Diamond Tile 7.25" x.032" Aluminum 7.25" x 24GA Steel Page 41 of 43

(FORMERLY FL 22548) GA. AVAILABLE: 24 GA. STEEL.032 ALUMINUM MATERIALS: STEEL ALUMINUM SIZES AVAILABLE: 8 3/8" x 14 1/2" FINISH: PAC-CLAD PVDF WEBSITE: WWW.PAC-CLAD.COM HQ: 1005 Tonne Road Elk Grove Village, IL 60007 P: 800-PAC-CLAD F: 800-722-7150 9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627 10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592 102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533 SALES OFFICE 1885 Station Parkway NW Suite B P: Page 877-571-2025 42 of 43 F: 866-901-2935 PG. 1

(FORMERLY FL 22548) GA. AVAILABLE: 24 GA. STEEL.032 ALUMINUM MATERIALS: STEEL ALUMINUM SIZES AVAILABLE: 8 3/8" x 14 1/2" FINISH: PAC-CLAD PVDF WEBSITE: WWW.PAC-CLAD.COM HQ: 1005 Tonne Road Elk Grove Village, IL 60007 P: 800-PAC-CLAD F: 800-722-7150 9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627 10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592 102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533 SALES OFFICE 1885 Station Parkway NW Suite B P: Page 877-571-2025 43 of 43 F: 866-901-2935 PG. 2