DESCRIPTION 1 1 lot 10,648,751.67 Brand new, not reconditioned including its Parts & Accessories 1. Wrist Arthroscope a. HD wide angle 30-degree small joint arthroscope i. One (1) short scope (1 piece) ii. One (1) long scope (1 piece) b. Autoclavable c. 2.7mm outer diameter d. Fiber optic light transmission incorporated 2. Arthroscope Sheath a. High flow cannula for wrist scope i. 2.9mm for 2.7mm short scope (1 piece) ii. 2.9mm for 2.7mm long scope (1 piece) b. Dual port c. Rotatable d. Diameter 2.9mm e. Compatible with 30-degree scopes f. Must be supplied with blunt obturator, conical tip (2 pieces) g. Small joint probe 70-degree, 90mm (2 pieces) 3. Camera Head a. 3-chip full HD camera head (1 piece) b. Autoclavable c. Camera head with buttons for controls d. 2.5x optical zoom e. Focal length 15-31mm or better 4. Camera Console a. Camera console (1 piece) b. 1920 x 1080 minimum screen resolution c. Power supply: 100-240 VAC, 50/60Hz d. Power cord included \\cmp.19.11.2015 Page 1
DESCRIPTION 5. Light Source (1 piece) a. 150W LED or Xenon light source b. Universal fiber optic light cable c. Diameter at least 3.5mm, length at least 180cm d. With one (1) spare bulb e. Power supply: 100-240 VAC, 50/60Hz 6. Monitor (1 piece) a. Full HD flat panel medical grade LED or LCD monitor b. At least 26 inches c. Minimum resolution: 1920 x 1080p with 16:9 image format d. Power cord included e. Power supply: 100 to 240 VAC, 50/60Hz 7. Shaver Console (1 piece) a. Shaver console b. Touch screen operation c. With different soft tissue modes d. Auto-recoginition of shaver e. At least two (2) hand piece portals f. At least one (1) foot switch pedal g. Speed range: 1000-8000 RPM h. Motor cables at least 100cm long i. Compatible shaver hand piece (1 piece) i. Simultaneous control of suction and rotation of shaver blade ii. Programmable push buttons in hand piece iii. Compatible with various shaver cutters/tips/burrs of the same brand iv. Can accommodate speed range of 1000-8000 RPM v. Easy release button j. Power supply: 100-240 VAC 8. Radiofrequency Generator System (1 piece) a. Radiofrequency generator console b. Adjustable radiofrequency strength and modes (mopolar, bipolar, and temperature control) c. With audible alarm sound capability and displays error messages \\cmp.19.11.2015 Page 2
DESCRIPTION d. Foot control switch with at least two (2) pedals (1 piece) e. Compatible split electrode pads f. Bipolar ablation probe with integrated suction angled 90 degrees (1 piece) g. Compatible power cord available e. Power supply: 100-240 VAC 9. Pistol Grip Drill (1 piece) a. Compatible with power control unit b. Compatible with power cord / cable assembly (1 piece) c. Compatible with sagittal saw attachment with sterile disposable blades (1 piece) i. Sagittal saw blade, 5.8mm x 18mm x 0.4mm with straight fine teeth, etched marking and depth stop (3 boxes) ii. Sagittal saw blade, 5.8mm x 12mm x 0.4mm with straight fine teeth, no markings and depth stop (3 boxes) iii. Sagittal saw blade, 9.4mm x 25.5mm x 0.4mm with straight fine teeth, with etched markings, no depth stop (3 boxes) d. Compatible jacobs chuck with key (1 piece) e. Compatible sterilization tray for drill and attachments (1 piece) 10. Insruments a. Hand Pieces i. Tip grasper 2mm x 90mm (1 piece) ii. Grasper 2.75mm x 90mm (1 piece) iii. Mosquito tip grasper 2mm x 90mm (1 piece) iv. Mosquito tip grasper 2.75mm x 90mm (1 piece) v. 45-degree right tip biter 2mm x 90mm (1 piece) vi. 45-degree left tip biter 2mm x 90mm (1 piece) vii. Blunt probe, straight 2mm x 90mm (1 piece) viii. Oval puch straight 2mm x 90mm (1 piece) ix. Suction punch straight 2.5mm x at least 90mm (1 piece) b. Blades and Burrs i. 2.0mm cutter x 70mm (5 pieces) ii. 2.0mm full radious x 70mm (5 pieces) iii. 3.5mm full radious x 70mm (5 pieces) \\cmp.19.11.2015 Page 3
DESCRIPTION 11. Accessories a. Mobile Trolley / Cart (1 piece) i. At least four (4) level multi-cart for arthroscope consoles ii. Single-lockable drawer iii. Four (4) heavy duty caster wheels, lockable iv. At least 835 x 1580 x 750mm dimensions v. Weight without load: at least 75kg vi. Load capacity of cart: at least 210kg vii. With built-in cable ducts viii. With four (4) hook IV stand with adjustable height b. Digital Computer Recording / Image Management System (1 piece) i. Dual channel up to full HD resolution 2D/3D ii. Compatible at least 19" monitor preferably touchscreen for controls, 1920 x 1080 resolution iii. Able to record in USB, CD-R and DVD-R iv. Video format: NTSC and PAL v. At least with 200GB internal hard drive vi. Compatible connecting cables at least 200cm vii. Compatible power cord viii. Power supply: 100-240 VAC, 50/60 Hz c. Instrument Sterilization Tray (2 pieces) i. Stainless steel ii. Autoclavable TOTAL CONTRACT PHP10,648,751.67 TERMS & CONDITIONS: 1. Indicate brand, model and country of origin. 2. Notarized certificate that the product is brand new, not reconditioned including parts and accessories. 3. Certificate of authorized distributorship for the item being offered. 4. Notarized certificate accompanied by proof that the bidder must be in the business of supplying the above item / equipment for the last for the last five (5) years. 5. Notarized certficate that the bidder and its principal must have been in business relationship for at least five (5) years. 6. Notarized certificates of good track records within three (3) years from at least two (2) government and/or private hospitals within Metro Manila. \\cmp.19.11.2015 Page 4
cont TERMS & CONDITIONS: 7. Delivery should be done within sixty (60) calendar days commencing on the 3rd working day of notification through confirmed fax that the approved Purchase Order / Contract is already available for pick-up. 8. Two (2) years comprehensive warranty. This include at least four (4) preventive maintenance per year and unlimited corrective maintenance per year and unlimited corrective maintenance and parts. 9. Warranty period shall commence from the date of acceptance by the end-user. 10. Automatic provision of a functioning service unit during the warranty period (same model) in case of repair of the purchased unit within seventy two (72) hours of notification. 11. Must guarantee than any new software updates will be installed and included during the scope of warranty. 12. Availability of service neigneers (Certified factory trained on service and repair). One service engineer must be available locally to provide quick 24/7 on-site support with guaranteed uptime 48 hours. Certification must be provided. 13. List of factory-trained local engieners with certificate of training in handling the specific machine from the manufacturer must be submitted. 14. Guarantee letter from the manufacturer and local distributor to ensure availability of supplies, parts and accessories in the Philippines for the next ten (10) years. 15. Must provide a separate quotation fo the maintenance, repair and replacement of parts after the warranty. 16. Must provide at least three (3) installations within Metro Manila including contact persons and contact number/s. Include service centers. 17. Must include on-site technical training for two (2) biomedical staff from the Office of the Engineering and Technical Services (OETS) and at least two (2) operating room nurses. Duration of training will depend on the recommendation of the winning bidder. 18. Must also include on-site training for use to at least four (4) end-users. 19. Provide certificate of performance evaluation from other hospitals in the Philippines. 20. Certificate of the unit that it conforms to the International Electrotechnical Commission (IEC) Standards or its equivalent 21. Certificate of demonstration including the brand and model being offered must be submitted. 22. Include technical specifications (brochure / catalogue). 23. The winning bidder must provide original and hard copy of operators and service manuals upon delivery. 24. The bidder guarantees that the bid offer is the lowest price in the market. 25. All certifications (#4, #5 and #6) required in the Terms & Conditions shall be placed in the Envelope 1 (Technical Component). 26. The bidder is required to submit single bid for the item. Two or more bids offer is automatically disqualified. 27. Compliance with the provisions of Republic Act No. 9184 and other applicable laws. \\cmp.19.11.2015 Page 5