THIS DRAWING IS PROPERTY OF AND PROPRIETARY TO EMERSON. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED NOR DISCLOSED TO ANYONE EXCEPT THOSE REQUIRING ITS USE FOR EMERSON AUTHORIZED PURPOSES. THIS DOCUMENT SHALL BE DESTROYED OR RETURNED TO EMERSON WHEN NO LONGER REQUIRED FOR THOSE PURPOSES. A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters REV ECO NO. 0 Initial Release 6-Oct-07 E76 -DEC-07 Entity Parameters Connection Power In Power Out Sensor Out* Sensor In Terminals Power and Ground Bottom Plug S+ & S- / S+ & S- SIG / SIG & COM Marking Parameters Ui = 8 V Ui = 8 V Uo = 7.65 V Uo = 7.65 V Uo = 5. V Uo = 5. V Uo = 7. V Uo = 7. V Ii = 0 ma Ii = 70 ma Io = 06 ma Io = 06 ma Io = 7 ma Io = 7 ma Io = 9. ma Io = 9. ma Pi = 0.8 W Pi =.9 W Po = 8 mw Po = 8 mw Po = 0.8 W Po = 0.8 W Po = 55 mw Po = 55 mw Ci = 0 nf Ci = 0 nf Co = 9.8 µf Co = 85 µf Co = 75 nf Co = 58 nf Co =. µf Co = 00 µf Li = 80 µh Li = 80 µh Lo =. mh Lo = 7. mh Lo =. mh Lo = 5 mh Lo =. mh Lo = 9.5 mh * Entity parameters for sensor out S+ / S- & S+ / S- reflect total combined limitations for both channels. An appropriate shall be used to power the Emerson Transmitter. Conditions of Safe Use A9000Px shall be installed inside of an enclosure with a minimum IP rating of IP6. Field wiring using multiconductor cable shall either have each conductor enclosed in grounded metal shield or each conductor have a minimum of 0.5mm (0.0") insulation thickness. If an earth connection is made inside the transmitter housing, it should be made through the same enclosure entry as the external sensors. Model A9000PA: CSA-c/us 7CA7006 Class I, Div., Groups A, B, C & D, T; Class II, Div., Groups E, F & G; Class I, Zone 0, A/ SIRA/ATEX 7ATEXX 058 II G IECEx CSA 7.008X Model A9000PS: CSA-c/us 7CA7006 Class I, Div., Groups C & D, T; Class I, Div., Groups A, B, C & D T; Class I, Zone 0, A/; Class I, Zone, A/ SIRA/ATEX 7ATEXX 058 II G SIRA/ATEX 7ATEX75X II G IECEx CSA 7.008X Ta: -0 C to +85 C Emerson 85 Innovation Drive Knoxville, TN 79 USA Agency approved drawing. No changes without prior agency approval. MATERIAL: FINISH: ARTWORK FILENAME/: UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES DECIMALS:.X ±.00.XX ±.00.XXX ±.00 FRACTIONS: ± / ANGULAR: FINISH: ± 0-0' DO NOT THIS DRAWING DESIGNED BY: DRAWN BY: For Reference Only LAST REVISED BY: RESP. ENGINEER MANUFACTURING ENG. DOCUMENT CONTROL J. Clemons 0-AUG-07 J. Clemons 0-AUG-07 J. Clemons -DEC-07 J. Baldwin 0-Aug-07 TITLE FIRST USED MODEL NO. A9000X A9000Px Installation Drawing OF 5
A9000Px Power/Signal Adapter for Accel Input to the AMS 90 Low Power Accel (5 mv/g) Sensor Sensors Sensor with Temperature Terminal = Both Red Wires Terminal = Red Wire Terminal = Red Wire Terminal = White Wire Terminal = White Wire Terminal = White Wire Terminal = White Wire Terminal = White Wire Terminal = Green Wire Terminal = Both Black Wires Terminal = Both Black Wires Terminal = Black Wire = Both Cable s = Both Cable s = Cable 5 mv/g 5 mv/g Sensors are mounted to equipment being monitored. A9000PA or A9000PS-A S+ will be tied to Earth ground if Barrier is Sig Sig S- S- S+ 0 OF 5
Sensor S+ = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) A9000PS-A Power/Signal Adapter for Accel Input to the AMS 90 Powered ICP Accel (00 mv/g) Sensors S + = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) From A9000Px to AMS 90 Sig to Term Block Terminal = Gray Wire Sig to Term Block Terminal = Blue Wire to Term Block Terminal = Black Wire S+ Sig Sig S- S- S+ will be tied to Earth ground if Barrier is 00 mv/g 00 mv/g Sensors are mounted to equipment being monitored. 0 OF 5
A9000PS-V Power/Signal Adapter for Volts Input External Device with equivalent Entity Parameters Sensor S+ = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) Sensors S + = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) From A9000 to AMS 90 Sig to Term Block Terminal = Gray Wire Sig to Term Block Terminal = Blue Wire to Term Block Terminal = Black Wire S+ Sig Sig S- S- S+ Volt Input Volt Input will be tied to Earth ground if Barrier is External Device VOLTS input must maintain the entity parameters listed on Page. 0 OF 5
A9000Px Power Adapter for Emerson Transmitters Sensors are internal to the transmitter A9000PA or A9000PS-A S+ S- S- S+ Sig Sig will be tied to Earth ground if Barrier is 0 5 OF 5