BXUV.V470. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

Similar documents
UOXX.S3403 Control Unit Accessories, System. Control Unit Accessories, System

GlasRoc Sheathing Type X

TECH BULLETIN SIP No Subject: Fire Resistive Assemblies Date: November 2007 (Revised May 2017) Roof/Ceiling: 1-Hour Rating

Table of Contents F Series Frames

UL 580 Construction No: ½ in Mechanical Lock w/ Clip

UL 580 Construction No: ½ in Snap Lock w/ Clip

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.

Construction No. 90. Construction No. 90

HOLLOW METAL DOOR/WINDOW SYSTEM FOR THERMALSAFE CF WALLS WINDOW ASEMBLY GUIDE PIONEERING INSULATED METAL PANEL TECHNOLOGY

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

VNIV.EX454 - Sprinklers, Automatic and Open. Sprinklers, Automatic and Open

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

UNA-CLAD Metal Roof Systems

UL Construction No. 254

Horizontal Shaft Wall

NORMAL WEIGHT CONCRETE TOTAL-LEWIS-DECK GYPSUM BOARD 2 OR 3-PLY COMPOSITE TOTALJOIST TOP CHORD CONNECTION

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

MECHANICAL BACK FASTENED SYSTEMS INSTALLATION DATA

UL Online Certifications Directory

ROHS DECLARATION OF CONFORMITY

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337

Please read these instructions thoroughly prior to beginning the Acrovyn Z-Clip Wall Panel installation!

SINGLE TRACK BYPASS (patent pending) barn door hardware

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Display Shelving Installation Instructions

1530(F) Mortise Exit Devices Installation Instructions

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

Versatrac R-System Stock Extrusions, Clips and Accessories

Versatrac R-System Stock Extrusions, Clips and Accessories

#11179 Wellington ARBOR

CBUCK Engineering. for. Florida Product Approval # FL R1

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products

Paraguard Roof Perimeter Systems ANSI/SPRI ES-1 Test Reports UL. Classified Products

Lightplane 3.5 Recessed

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

Track Rack. * Track Racks are not lockable

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Assembly Instructions

CERTIFICATE OF APPROVAL No CF 718 PILKINGTON GROUP LIMITED

WoodWORKS Channeled Plank

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

Construction details: Master-C type profiles and joints:

Installation and Assembly: Full Service Video Wall Mount

Site Preparation Information for:

12' x 8' Chicken Run Plan. Up to 15 chickens

Half Round 180 Displacement Diffuser

ESR-2648 Reissued May 1, 2012 This report is subject to renewal June 1, 2013.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

THE ENGINEERED WOOD ASSOCIATION

1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls

Exterior Wall Fastener Schedule

VPN: ISBXLR. Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

ANSI/BHMA A Revision of ANSI/BHMA A

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

ULT R A S PACE SAV E R SQ UA R E D

NX7 SERIES 5-1/2 HANDRAIL

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

SDWH TIMBER-HEX Screw

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

DETAIL LOCATOR PRODEMA EXPOSED FASTENER SYSTEMS ON STUD WALL. Page: 00 of 22

Description. Lesson Outcomes. Assumptions. Build a Floor. Carpenter

Vertical Offset Base and Safety Rail System Installation Instructions

QIJQ2.E Connectors for Use in Photovoltaic Systems - Component. Connectors for Use in Photovoltaic Systems - Component

ProBuilder Series CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

Method of Build 1. General

Fixings. Products - Fixings.

Small Flush Wood Flue Adapter Installation Instructions (SKU )

Ash Brook Golf Course Scotch Plains, New Jersey

Originally Issued: 09/26/2012 Revised: 10/15/2018 Valid Through: 09/30/2019

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

Installation and Operation Manual. Ajustable Valance Kits CAUTION: Duke Manufacturing Co.

Installation Guide. Ceiling Suspended Acoustical Panels

Windload Post 9100/9600/9900 Installation Instructions

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Method of Build 1. Fire. Sound

APA Performance Rated Rim Boards

TO O L K IT. Public Bike Repair

ProBuilder Linear CoolSmart TV (42PB - sku# )(54PB - sku# )(72PB - sku# )

Installation Manual for M4-Exterior Sheathing

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

ABET MEG PANEL - HIDDEN FASTENER PANEL SYSTEM ON STUD WALLS

Leveling Feet, Base Plates and Casters

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

METALWORKS Linear (Interior & Exterior Applications)

installation care & maintenance instructions moistureshield.com limited lifetime warranty

ECOPHON Focus Ds 4x4 Installation Manual

#11179 Wellington ARBOR

FireCase. Frameless structural steel encasement system. FireCase.

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

Desk/Wall-Mount Rack

THIS PAGE INTENTIONALLY LEFT BLANK

CertainTeed INSTALLATION GUIDE SIMTEK FENCE PRODUCTS. Fence Installation Guide 3', 4' & 6' High

Office Installation Guidelines

Transcription:

Page Bottom BXUV.V470 Fire Resistance Ratings - ANSI/UL 263 Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Listed or Classified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. V470 December 09, 2009 Nonbearing Wall Ratings 1, 2 or 3 Hr

1. Floor, Side and Ceiling Runners "J" -shaped runner, min 2-1/2 in. deep, with unequal legs of 1-1/8 in. and 2-1/8 in., fabricated from min 25 MSG galv steel. Runners positioned with short leg toward finished side of wall. Runners attached to structural supports with steel fasteners located not greater than 2 in. from ends and not greater than 24 in. OC. 2. Steel Studs

Systems A, B, E, G and I "I" -shaped studs fabricated from min 25 MSG galv steel, min 2-1/2 in. deep, 1-1/2 in. wide. Studs contain 3/4 in. wide by 2-1/4 in. high holding tabs spaced 2-3/4 in. OC. Cut to lengths 5/8 in. less than floor-to-ceiling height and spaced 24 in. Systems C, D, F, H and J "C-T" -shaped studs, min 2-1/2 in. deep, 1-1/2 in. wide, fabricated from min 25 MSG galv steel. Cut to lengths 5/8 in. less than floor-to-ceiling height and spaced 24 in. 3. Gypsum Board* Gypsum liner panels, nom 1 in. thick, 24 in. wide. Panels cut max 1 in. less in length than floor to ceiling height. Vertical edges inserted in "T" -shaped section of "C-T" studs or tabs holding tabs of "I" studs. Free edge of end panels attached to long leg of "J" -runners with 1-5/8 in. long Type S self-drilling, self-tapping bugle head steel screws spaced not greater than 12 in. OC. CERTAINTEED GYPSUM INC Type EGRG Shaftliner, GlasRoc Shaftliner. 4. Gypsum Board* Systems A and C For use with Type EGRG Shaftliner liner panels - Gypsum panels, nom 1/2 or 5/8 in. thick, 48 in. wide, applied in one of the following methods. Method 1 Base layer installed horizontally to steel studs with 1 in. long Type S self-drilling, self-tapping bugle head steel screws spaced 24 in. OC. with the 1st screws installed 12 in. from the board edge. Face layer installed vertically to steel studs with 1-5/8 in. long Type S self-drilling, self-tapping bugle head steel screws spaced 12 in. OC. with the 1st and 2nd screws spaced 3/4 in. and 6-3/4 in. from the board edge, staggered 12 in. from base layer screws. Method 2 Base layer installed vertically to steel studs with 1 in. long Type S self-drilling, self-tapping bugle head steel screws spaced 24 in. OC. with the 1st screws installed 12 in. from the board edge. Face layer installed horizontally to steel studs with 1-5/8 in. long Type S self-drilling, self-tapping bugle head steel screws spaced 24 in. OC., with the 1st and 2nd screws installed 3/4 in. and 6-3/4 in. from the board edge, staggered 12 in. from base layer screws. Additionally, Type G screws to be installed at the center of each stud cavity, spaced 12 in. OC., 1-1/2 in. from both sides of the horizontal joint. For the 1/2 in. thick and 5/8 in. thick boards, the Type G screw length shall be 1-1/4 in. and 1-1/2 in. long, respectively. CERTAINTEED GYPSUM INC 1/2 in. thick ProRoc Type C, 5/8 in. thick ProRoc Type C or 5/8 in. thick ProRoc Type X Systems B and D Gypsum panels, nom 1/2 or 5/8 in. thick, 48 in. wide, applied vertically to steel studs with 1 in. long Type S self-drilling, selftapping bugle head steel screws spaced 12 in. OC. Vertical joints on opposite sides of wall staggered a min of 24 in. CERTAINTEED GYPSUM INC 1/2 in. thick ProRoc Type C, 5/8 in. thick ProRoc Type C or 5/8 in. thick ProRoc Type X Systems E and F Gypsum panels, nom 5/8 in. thick, 48 in. wide, applied vertically with edges centered over studs, with 1 in. long Type S selfdrilling, self-tapping bugle head steel screws spaced 12 in. OC. CERTAINTEED GYPSUM INC ProRoc Type X or ProRoc Type C Systems G and H Gypsum panels, nom 5/8 in. thick, 48 in. wide applied in three layers to one side of the assembly. Base layer applied vertically, remaining layers applied vertically or horizontally. Base layer attached to studs with 1 in. long Type S steel screws spaced 24 in. OC. Middle layer attached to studs with 1-5/8 in. long Type S steel screws spaced 24 in. OC when installed vertically or 16 in. OC when installed horizontally. Face layer attached to studs with 2-1/4 in. long Type S steel screws spaced 16 in. OC when installed vertically or 12 in. OC when installed horizontally. Screws offset 6 in. from layer below. Horizontal joints on adjacent layers staggered a min of 12 in. When applied horizontally, 1-1/2 in. long Type G screws to be installed at the center of each stud cavity, 1-1/2 in. from both sides of the horizontal joint. Vertical joints centered over studs and staggered 24 in. on adjacent layers.

CERTAINTEED GYPSUM INC ProRoc Type C Systems I and J Gypsum panels, nom 5/8 in. thick, 48 in. wide applied in two layers to one side of the assembly and one layer to the other side. On the two layer side, base layer applied vertically, face layer applied vertically or horizontally. Base layer attached to studs with 1 in. long Type S steel screws space 24 in. OC. Face layer attached to studs with 1-5/8 in. long Type S steel screws spaced 24 in. OC when installed vertically or 16 in. OC when installed horizontally. Screws offset 6 in. from layer below. When applied horizontally, 1-1/2 in. long Type G screws to be installed at the center of each stud cavity, 1-1/2 in. from both sides of the horizontal joint. Vertical joints centered over studs and staggered 24 in. on adjacent layers. On the one layer side, panels applied vertically and attached to studs with 1 in. long Type S steel screws spaced 12 in. OC. Vertical joints on opposite sides of wall staggered min 24 in. OC. CERTAINTEED GYPSUM INC ProRoc Type C 5. Joint Tape and Compound (Not shown) Joints covered with joint compound and paper or mesh tape. Screw heads covered with joint compound. *Bearing the UL Classification Mark Last Updated on 2009-12-09 Questions? Print this page Notice of Disclaimer Page Top Copyright 2010 Underwriters Laboratories Inc. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright 2010 Underwriters Laboratories Inc. "